TETRAIndoor Coverage

Kimmo MarkkanenHead of Support

Länsi-Uusimaa Department for Rescue Services

Page 2: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

VIRVE Network– 1.400 base stations and 32.000 subscribers– Nationwide coverage in operation since 2002– Operated by State Security Networks ltd.

4 ,5 Million SDS messages/day it is growing100 000 group calls/day

2

Page 3: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Tetra (VIRVE) and Rescue Services• Fire and Rescue Services is one of many users• Tetra (VIRVE) is part of Command and Control

24th May 2011 Kimmo Markkanen TWC2011 3

Page 4: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

24th May 2011 Kimmo Markkanen TWC2011 4

Organisation at Rescue OperationsOrganisation at Rescue Operations

RescueUnit

Rescue UnitRescue Unit(1+3 = 4)(1+3 = 4)

P3

RescueUnit

RescueUnit

Rescue PlatoonRescue Platoon(1+3+10 = 14)(1+3+10 = 14)

Government levelGovernment level Ministry of the Interior

Section 2 chief

RescueUnit

RescueUnit

RescueUnit

Section 3 chief

RescueUnit

RescueUnit

RescueUnit

Länsi-Uusimaa P2

Command Post(P3 +__ )

Section 4L4 (med. supervisor)

Ambulance

Ambulance

Ambulance

Rescue CompanyRescue Company(7+9+33) = 49)(7+9+33) = 49)

(Section 1 chief)

Municipality’s board

Command Center(Other Accident Areas ->)(Other Accident Areas ->)

Rescue Service RegionRescue Service Region

Page 5: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Demands for Radio Network

• The network has to be operational all the time 24/7/365

• Te coverage should be adequate all the working area (including indoors)

24th May 2011 Kimmo Markkanen TWC2011 5

Page 6: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Indoor Coverage

• First the coverage should be assured without active extra installations

• Secondarily there may be need for active repeaters– big building complexes (i.e. malls)– underground spaces

24th May 2011 Kimmo Markkanen TWC2011 6

Page 7: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Why Active Repeaters?• Traditionally fire fighters

communicated from terminal to terminal without connection to base station– TETRA DMO

• But if we want to have full advantage from TETRA network, the terminal needs the base station connection– Fixed repeaters– DMO Gateway terminals

24th May 2011 Kimmo Markkanen TWC2011 7

Page 8: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Rule for VIRVE Indoor Coverage at New Buildings

• Common rule at Capital area of Finland (four Fire & Rescue Departments)

• With collaboration of the network operator State Security Networks ltd (VIRVE)

24th May 2011 Kimmo Markkanen TWC2011 8

Page 9: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Rule for Securing the VIRVE-services in Buildings

• The State Security Networks rule for planners and contractors

• Technology and process, when there is need for built-in active solutions (repeaters)

• http://www.erillisverkot.fi/?lang=en – http://www.erillisverkot.fi/public/files/Ohje%20-%20VI

RVE-kuuluvuuden%20toteuttaminen.pdf (only in Finnish)

24th May 2011 Kimmo Markkanen TWC2011 9

Page 10: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Repeater Solution

24th May 2011 Kimmo Markkanen TWC2011 10

repeater repeater

aerial

leaky cable

cable

power splitter

cable

power splitter

Page 11: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Active Repeater

24th May 2011 Kimmo Markkanen TWC2011 11Active repeater needs external power (electricity)!

outdoor antenna

base station

rf-signalrepeater

Page 12: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Passive Repeater

24th May 2011 Kimmo Markkanen TWC2011 12

Passive repeater does not need external power. The covered area is quite small, like small basement or shelter.

outdoor antenna base station

rf-signal rf-signal

indoor antenna

Low-loss cable

Page 13: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Three Ways for Indoor Coverage solution:

1. Authority specification for building license (new building)

2. Authority specification afterwards (existing building), Rescue Act

3. Owner specification (user demand, security level of building)

24th May 2011 Kimmo Markkanen TWC2011 13

Page 14: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Valid Rescue Act 30 § about special safety arrangements

“If there is special reason, Rescue Authorities may order to have extinguishing equipments and other installations to help rescue operations”– So we have some power to improve indoor coverage, if we read

the “other installation” widely. – Same rule is also at the new Rescue Act

• The new Rescue Act will give more power (valid from 1st of July 2011)

24th May 2011 Kimmo Markkanen TWC2011 14

Page 15: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

The New Rescue Act 109 § about the availability of PSS-network

“If there is major risk for human losses and the availability of PSS-network is not good enough for rescue operations, the Rescue Authorities may order the owner of the building to buy and maintain equipments that are necessary for securing the PSS-network coverage in building.”– Restriction for human losses and rescue operations– Emergency Medical and Police operations?– Preparedness and alerting (i.e Malls and other public places)?

24th May 2011 Kimmo Markkanen TWC2011 15

Page 16: Tetra Indoor Coverage

The Process

Page 17: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

The Evaluation for Needs

• Planner fills special form with Rescue Authority (similar as used with Fire Alarm Systems)

• The form will be attached to building license documents

• The evaluation is needed for– Major gathering- and business premises– Underground spaces (not for ordinary basements)– When there is need for Automatic Fire Extinguishing

or Alarm system

24th May 2011 Kimmo Markkanen TWC2011 17

Page 18: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

The Evaluation for Needs

• The form is attached to Rescue Services Rule– Like the documentation of Fire Alarm System

• Probably there is no need for special repeater solution• If the repeater solution is needed

– National Emergency Supply Agency covers the cost of the repeater– Owner covers the cost of wiring and other installations (i.e. power

supply)– The State Security Networks owns and maintains the repeater

• The State Security Networks ltd trains and maintain the valid list of planners and contractors trained by them– actually there is no validation method for the planners and

contractors24th May 2011 Kimmo Markkanen TWC2011 18

Page 19: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Procurement of the Repeater

• The State Security Networks ltd. defines the specifications for the repeater

• The State Security Networks ltd. runs the public tender process for the repeaters (app. every 3rd year) and makes general agreement with distributors

• Other active repeater installations are not allowed in the VIRVE-network

24th May 2011 Kimmo Markkanen TWC2011 19

Page 20: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Indoor Coverage

• Entire building (field strength ≥-86 dBm at 90 % probability)– Especially covered

• Escape and rescue routes• Technical rooms for safety and security (i.e. control rooms,

sprinkler centrals)

• Specially defined areas (marked to attached blueprints)– User needs i.e. hospitals and security premises– Underground spaces

24th May 2011 Kimmo Markkanen TWC2011 20

Page 21: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

24th May 2011 Kimmo Markkanen TWC2011 21

Kiinteistönomistaja/rakennuttaja

ERVE Oy toimittaaFICORAlle

Rakennuslupa-hakemus

Riskianalyysi

PÄÄTÖS

Merkintä raken-nuslupaan

Täytetään lomake L1

Yhteys RV-suunnittelijaan ja/tai asennusyritykseen.Työn tilaus.

SUUNNITELMA

Oma päätös

Täytetään asennuskansion suunnitelma- ja taajuus-lupahakemusosa ja tilataanlopputarkastus. Dokumentit toimitetaan ERVE Oy:lle

Taajuuslupa-hakemus

Sisäverkon asennussuunnitelman mukaisesti

KÄYTTÖÖNOTTO-mittaukset-kuuluvuuden todentaminen

Loput tiedotasennuskansioon,joka toimitetaan ERVE Oy:lle

Peittovaatimukset merkitään kiinteistön pohjapiirustuk-seen

Kiinteistönomistajanlopputarkastus ja

hyväksyntä

Lopputarkastusja hyväksyntä

Kiinteistönomistaja/rakennuttaja

Viranomainen

ViranomainenEI

KYLLÄ

Rakennuslupa-viranomainen

Viranomainen jakiinteistönomistaja/rakennuttaja

KYLLÄ

Kiinteistönomistaja/rakennuttaja

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Kiinteistönomistaja/rakennuttaja

Hyväksytty ja valmis

Ilmoitus viranomaiselle, mikäli näin vaadittu

ERVE Oy

Kiinteistönomistaja/rakennuttaja

KYLLÄKYLLÄ

EI

EIEI

Suoritetaan korjaavat toimenpiteet

Ei toteuteta

Kiinteistönomistaja/rakennuttaja

ERVE Oy toimittaaFICORAlle

Rakennuslupa-hakemus

Riskianalyysi

PÄÄTÖS

Merkintä raken-nuslupaan

Täytetään lomake L1

Yhteys RV-suunnittelijaan ja/tai asennusyritykseen.Työn tilaus.

SUUNNITELMA

Oma päätös

Täytetään asennuskansion suunnitelma- ja taajuus-lupahakemusosa ja tilataanlopputarkastus. Dokumentit toimitetaan ERVE Oy:lle

Taajuuslupa-hakemus

Sisäverkon asennussuunnitelman mukaisesti

KÄYTTÖÖNOTTO-mittaukset-kuuluvuuden todentaminen

Loput tiedotasennuskansioon,joka toimitetaan ERVE Oy:lle

Peittovaatimukset merkitään kiinteistön pohjapiirustuk-seen

Kiinteistönomistajanlopputarkastus ja

hyväksyntä

Lopputarkastusja hyväksyntä

Kiinteistönomistaja/rakennuttaja

Viranomainen

ViranomainenEI

KYLLÄ

Rakennuslupa-viranomainen

Viranomainen jakiinteistönomistaja/rakennuttaja

KYLLÄ

Kiinteistönomistaja/rakennuttaja

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Suunnittelija ja/taiasennusyritys

Kiinteistönomistaja/rakennuttaja

Hyväksytty ja valmis

Ilmoitus viranomaiselle, mikäli näin vaadittu

ERVE Oy

Kiinteistönomistaja/rakennuttaja

KYLLÄKYLLÄ

EI

EIEI

Suoritetaan korjaavat toimenpiteet

Ei toteuteta

Page 22: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Approval

• The contractor send the installation folder to the State Security Networks

• The subscriber makes the visual inspection that all of the installation are correct

• The contractor or the planner shows for the owner of the building (subscriber) that the need for indoor coverage is correctly secured

• After the installations and the needs of coverage seems to be correct, the subscriber accepts installation and informs the State Security Networks ltd that the indoor solution is ready for final inspection

24th May 2011 Kimmo Markkanen TWC2011 22

Page 23: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Final Inspection• Is done by the State Security Networks ltd

– The inspection and frequency license are subscribed from the State Security Networks

– The State Security Networks inspects the installations, rf-details, network service availability and that the indoor solution does not make any interference to outside of building or to other installations

• The contractor shows all the installation documents• In the form is given mark of approval

– The contractor confirms that all the installation has done as planned and documented

– The State Security Networks ltd has approved the repeater to be connected to VIRVE-network

24th May 2011 Kimmo Markkanen TWC2011 23

Page 24: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Initialization

• After the final inspection the State Security Networks gives the permit to use the repeater

• During the initialization process the repeater is connected to the monitoring system of the State Security Networks and the repeater is officially in use– For the stability of the network and frequency utilization it is

necessary, that the operator controls the active repeaters!

• The State Security Networks informs the subscriber (owner of building) that the repeater is in use

24th May 2011 Kimmo Markkanen TWC2011 24

Page 25: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

Finally

• The TETRA-technology is not the problem• What about the conditions that the system should

tolerate – Fire and flooding (how to protect the installations?)– Lack of electricity (how long the indoor coverage is

available without external power?)– Building Collapse– Criminal acts– Exceptional circumstances– How does the rescue units know that there is built-in

solution?24th May 2011 Kimmo Markkanen TWC2011 25

Page 26: Tetra Indoor Coverage

Länsi-Uudenmaan pelastuslaitosVästra Nylands räddningsverk

Länsi-Uusimaa Department for Rescue Services

24th May 2011 Kimmo Markkanen TWC2011 26

The Sello Mall Shooting The Sello Mall Shooting 31.12.200931.12.2009

Picture: Ilta-Sanomat

Page 27: Tetra Indoor Coverage