spad-502 - daumcfs7.blog.daum.net/upload_control/download.blog?fhandle=... · 2015-01-21 · the...

2
SPAD-502 Compact and lightweight for portability The SPAD-502 is small enough to fit in a pocket and is extremely lightweight (only 225g) so it can be easily taken anywhere. Quick, easy measurements Measurements are taken by simply inserting a leaf and closing the measuring head. It is not necessary to cut the leaf, so the same leaf can be measured throughout the growing process. Water-resistant The SPAD-502 is water-resistant, so it can be used outside even in the rain. *It is not immersible, and should not be cleaned with water. Low power consumption The SPAD-502 uses LED light sources, resulting in extremely low power consumption. One set of two AA-size alkaline-manganese batteries can provide approximately 20,000 measurements. Small measuring area The measuring area is only 2 × 3mm, allowing measurements of even small leaves. A sliding depth stop is included for accurate positioning of sample leaves. High accuracy High measuring accuracy (± 1.0 SPAD unit for rice-plant leaves) allows close examination of growing conditions. Data memory The SPAD-502 has memory space for 30 measurements. Data in memory can be recalled or deleted at a later time, and the average value of all data in memory can be automatically calculated. Reading checker A reading checker enables users to check that the SPAD- 502 is functioning correctly and providing accurate readings. A lightweight handheld meter for measuring the chlorophyll content of leaves without causing damage to plants. The SPAD-502 is a compact meter designed to help users improve crop quality and increase crop yield by providing an indication of the amount of chlorophyll present in plant leaves. The chlorophyll content of plant leaves is related to the condition of the plant, and thus can be used to determine when additional fertilizer is necessary. By optimizing nutrient conditions, healthier plants can be grown, resulting in a larger crop yield of higher quality. Features CHLOROPHYLL METER

Upload: others

Post on 24-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SPAD-502 - Daumcfs7.blog.daum.net/upload_control/download.blog?fhandle=... · 2015-01-21 · The SPAD-502 uses LED light sources, resulting in extremely low power consumption. One

SPAD-502

Mac OS 9.2J Adobe Illustrator 10JCF-1440_Efront.ai2003.9.5

Compact and lightweight for portabilityThe SPAD-502 is small enough to fit in a pocket and is extremely lightweight (only 225g) so it can be easily taken anywhere.

Quick, easy measurementsMeasurements are taken by simply inserting a leaf and closing the measuring head. It is not necessary to cut the leaf, so the same leaf can be measured throughout the growing process.

Water-resistantThe SPAD-502 is water-resistant, so it can be used outside even in the rain.*It is not immersible, and should not be cleaned with water.

Low power consumptionThe SPAD-502 uses LED light sources, resulting in extremely low power consumption. One set of two AA-size alkaline-manganese batteries can provide approximately 20,000 measurements.

Small measuring areaThe measuring area is only 2 × 3mm, allowing measurements of even small leaves. A sliding depth stop is included for accurate positioning of sample leaves.

High accuracyHigh measuring accuracy (± 1.0 SPAD unit for rice-plant leaves) allows close examination of growing conditions.

Data memoryThe SPAD-502 has memory space for 30 measurements. Data in memory can be recalled or deleted at a later time, and the average value of all data in memory can be automatically calculated.

Reading checkerA reading checker enables users to check that the SPAD-502 is functioning correctly and providing accurate readings.

A lightweight handheld meter for measuring the chlorophyll content of leaves without causing damage to plants.The SPAD-502 is a compact meter designed to help users improve crop quality and increase crop yield by providing an indication of the amount of chlorophyll present in plant leaves. The chlorophyll content of plant leaves is related to the

condition of the plant, and thus can be used to determine when additional fertilizer is necessary. By optimizing nutrient conditions, healthier plants can be grown, resulting in a larger crop yield of higher quality.

Features

CHLOROPHYLL METER

Page 2: SPAD-502 - Daumcfs7.blog.daum.net/upload_control/download.blog?fhandle=... · 2015-01-21 · The SPAD-502 uses LED light sources, resulting in extremely low power consumption. One

Mac OS 9.2J Adobe Illustrator 10JCF-1440_Eback.ai 2004.11.25

3-91, Daisennishimachi, Sakai.Osaka 590-8551, Japan

Konica Minolta Photo Imaging U.S.A., Inc. 725 Darlington Avenue, Mahwah, NJ 07430, U.S.A. Phone: 888-473-2656 (in USA), 201-574-4000 (outside USA) FAX: 201-574-4201Konica Minolta Photo Imaging Canada, Inc. 1329 Meyerside Drive, Mississauga, Ontario L5T 1C9, Canada Phone: 905-670-7722 FAX: 905-795-8234Konica Minolta Photo Imaging Europe GmbH Europaallee 17, 30855 Langenhagen, Germany Phone: +49 (0)511-7404-895 FAX: +49 (0)511-7404-809Konica Minolta Photo Imaging France S.A.S. Paris Nord II, 385, rue de la Belle-Etoile, B.P. 50077, F - 95948 Roissy C.D.G. Cedex, France Phone: +33 (0)1-49 38 25 19 FAX: +33 (0)1-49 38 47 71Konica Minolta Photo Imaging UK Ltd. 7-9 Tanners Drive, Blakelands North, Milton Keynes, MK14 5BU, United Kingdom Phone: +44 (0) 1908 283 939 FAX: +44 (0) 1908 618 662Konica Minolta Photo Imaging Austria GmbH Amalienstrasse 59-61, 1131 Vienna, Austria Phone: +43 (0)1-87882-430 FAX: +43 (0)1-87882-431Konica Minolta Photo Imaging Benelux B.V. Postbus 6000, 3600 HA Maarssen, The Netherlands Phone: +33 (0)30-2470860 FAX: +33 (0)30-2470861Konica Minolta Photo Imaging (Schweiz)AG Riedstrasse 6, 8953 Dietikon, Switzerland Phone: +41 43 322 97 40 FAX: +41 43 322 97 49Konica Minolta Business Solutions Italia S.p.A. Via Stephenson 37, 20157, Milano, Italy Phone: +39 02-39011-1 FAX: +39 02-39011-219Konica Minolta Photo Imaging Svenska AB Solna strandväg 3, P.O.Box 9058 S-17109, Solna, Sweden Phone: +46 (0)8-627-7650 FAX: +46 (0)8-627-7685Konica Minolta Photo Imaging (HK)Ltd. Room 1818, Sun Hung Kai Centre, 30 Harbour Road, Wanchai, Hong Kong Phone: 852-34137508 FAX: 852-34137509 Shanghai Office Rm 1211, Ruijin Building No.205 Maoming Road (S) Shanghai 20020, China Phone: 021-64720496 FAX: 021-64720214 Konica Minolta Photo Imaging Asia HQ Pte Ltd. 10, Teban Gardens Crescent, Singapore 608923 Phone: +65 6563-5533 FAX: +65 6560-9721KONICA MINOLTA SENSING, INC. Seoul Office 801, Chung-Jin Bldg., 475-22, BangBae-Dong, Seocho-ku, Seoul, Korea Phone: 02-523-9726 FAX: 02-523-9729

AEMDPK Printed in Japan9242-4817-412003 KONICA MINOLTA SENSING, INC. 9

The SPAD-502 determines the relative amount of chlorophyll present by measuring the absorbance of the leaf in two wavelength regions. The graph at right shows the spectral absorbance of chlorophyll extracted from two leaf samples using 80% acetone.From the diagram, it can be seen that chlorophyll has absorbance peaks in the blue (400-500nm) and red (600-700nm) regions, with no transmittance in the near-infrared region. To take advantage of this characteristic of chlorophyll, the SPAD-502 measures the absorbances of the leaf in the red and near-infrared regions. Using these two transmittances, the meter calculates a numerical SPAD value which is proportional to the amount of chlorophyll present in the leaf.

Determining when additional fertilizer is necessary A decrease in the SPAD value indicates a decrease in the chlorophyll content and nitrogen concentration. This decrease may be due to a lack of nitrogen available in the soil. This problem can be solved by adding fertilizer to the soil. For example, it was determined from past experience that for Sasanishiki rice plants a SPAD value of 35 or above was desirable to produce a target yield of 600kg/10a. During the differentiation and formation of ears, a period of rapid plant development, the SPAD value fell to between 29 and 32, indicating that additional fertilizer was necessary.

Type: Handheld meter for measuring chlorophyll using optical density difference at two wavelengthsMeasurement sample: Crop leavesMeasurement system: Optical density difference at two wavelengthsMeasurement area: 2 × 3mmLight source: 2 LEDs (light-emitting diodes)Receptor: 1 SPD (silicon photodiode)Display: Measurement data: 3-digit LCD with decimal point Data number: 2-digit LCDData memory: Space for 30 data setsControls: Power switch, AVERAGE key, ALL DATA DELETE key, ONE DATA DELETE key, and DATA RECALL keyPower source: 2 AA-size alkaline-manganese (1.5V) batteries

Battery line: More than 20,000 measurementsMinimum interval between measurements: Less than 2 secondsAccuracy: Within ± 1.0 SPAD unit (at room conditions, SPAD value between 0 and 50)Repeatability: Within ± 0.3 SPAD units (SPAD value between 0 and 50)Reproducibility: Within ± 0.5 SPAD units (SPAD value between 0 and 50)Temperature drift: Less than ± 0.4 SPAD units/°CTemperature range: Operation: 0 to 50°C; Storage: - 20 to +55°CDimensions: 164 ×78 × 49mm (6-7/16 × 3-1/16 × 1-15/16 in.)Weight: 225g (7-15/16 oz.) (not including batteries)Other: Warning buzzer; User calibration function

Specification subject to change without notice

Checking the nutritional condition of plants The chlorophyll present in the plant leaves is closely related to the nutritional condition of the plant. As can be seen from the graph below, the chlorophyll content (represented by the measured SPAD value) will increase in proportion to the amountof nitrogen (an important plant nutrient) present in the leaf. For a particular plant species, a higher SPAD value indicates a healthier plant.

Theory

Applications3.5

3.3

3.1

2.9

2.7

2.5

2.3

2.1

1.9

1.7

24 26 28 30 32 34 36 38 40 42

Leaf

-bla

de

nitr

ogen

con

cent

ratio

n

y =0.079 x - 0.154r =0.908*** n =68

Measured SPAD value

19841985

9.1 9.5 10.3 10.8 12.5 13.0

35

7.1 7.10 7.20 7.30 8.14

30 25 20 15 10 5 0

40

35

30

25

Mea

sure

d S

PAD

val

ue

Young earformation period

Young eargrowth line

Fully formedears appear

Ear differentlationperiod

Ear fertility

(1mm)

(3mm)

(8cm)

(16 -18cm)

Sasanishiki rice plant development

Burstingperiod

Days before fullyformed ears appear

Date(month.day)

400 500

Ultra-violet

Wavelength Infrared

600 700(nm)

Tran

cem

ittan

ce

A

B

SPECIFICATIONS