1
AC DC Xanbus Battery OR Inverter Out - AC 120/240V or 230V AC Sub Panel **Conext SW Main AC Panel Grid - AC 120/240V or 230V Grid FIT Meter Residential Meter Conext RL Residential load *Conext XW with XW Power Distribution Panel with SW Power Distribution Panel Conext Battery Monitor Conext SCP Conext ComBox © 2014 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies | AD20140507_Retrofit-grid tie PV with backup_XW Residential grid-tie solar with backup (Retrofit FIT meter installations) www.SEsolar.com XW+ Single-phase or split-phase (120/240VAC or 230 VAC) solution (7.0kW – 25.5 kW) *Up to two slave units are optional to increase power Conext inverter charger is added behind PV inverter to provide backup, no change to PV inverter FIT wiring is required. However backup power is limited to the capacity of the battery bank and the solar system cannot be used to charge the batteries while the grid is down. SW Single-phase or split-phase (120/240VAC or 230 VAC) solution (2.5 kW – 8.0 kW) Note: Confirm AC coupling compatibility with PV inverter manufacturer prior to installation PV modules **Additional slave unit is optional to increase power

Upload: hacong

Post on 23-Apr-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Residential grid-tie solar with backup (Retrofit FIT meter …cdn.solar.schneider-electric.com/wp-content/uploads/20… ·  · 2016-10-17Residential grid-tie solar with backup (Retrofit

ACDCXanbus

Battery

ORInverter Out - AC

120/240V or 230VAC Sub Panel

**Conext SW

Main AC Panel

Grid - AC 120/240V or 230V

Grid

FITMeter Residential

Meter

Conext RL

Residentialload

*Conext XWwith

XW Power Distribution Panelwith

SW Power Distribution Panel

ConextBatteryMonitor

Conext SCP Conext ComBox

© 2014 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its a�liated companies | AD20140507_Retro�t-grid tie PV with backup_XW

Residential grid-tie solar with backup (Retrofit FIT meter installations)

www.SEsolar.com

XW+ Single-phase or split-phase (120/240VAC or 230 VAC) solution (7.0kW – 25.5 kW)*Up to two slave units are optional to increase power

Conext inverter charger is added behind PV inverter to provide backup, no change to PV inverter FIT wiring is required. However backup power islimited to the capacity of the battery bank and the solar system cannot be used to charge the batteries while the grid is down.

SW Single-phase or split-phase (120/240VAC or 230 VAC) solution (2.5 kW – 8.0 kW)

Note: Con�rm AC coupling compatibility with PV inverter manufacturer prior to installation

PV modules

**Additional slave unit is optional to increase power