portfolio ld8art commercial recessed led retrofit · ld8art commercial recessed led retrofit ld8art...

28
IMPORTANT: Read carefully before installing fixture. Retain for future reference. WARNING Risk of Electrical Shock! Disconnect power at fuse or circuit breaker before installing or servicing. WARNING Risk of Fire! Do not install insulation within 76 mm (3 in) of any part of the luminaire or in a way that may entrap heat. WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING Installation and servicing to be performed only by qualified personnel, If not qualified, consult an electrician. WARNING Do not energize the LED Engine until the protective covering has been removed and the lower trim properly installed. Do not touch the yellow surface of the LED as it may damage the light engine. ADP140604 Installation Instructions – LD8ART Commercial Recessed LED Retrofit Instructions d’installation – Retrofit à DEL commercial encastré LD8ART Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART ote N This fixture should be supported by main runners or other structure that is capable of supporting fixture weight of 10 Ibs. SAFETY: When using electrical equipment, basic safety precautions should always be followed, including the following: 1. This unit is for recessed mounting only. Do not use in hazardous locations nor near gas or electric heaters. 2. Do not use this equipment for other than the intended use. 3. Install only in accordance with National Electrical Code and local regulatory agencies’ requirements. 4. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings. 5. Installation of this retrofit assembly requires a person familiar with the construction and operation of the luminaire’s electrical system and the hazard involved. If not qualified, do not attempt installation. Contact a qualified electrician. 6. Do not alter, relocate, or remove wiring, lampholders, power supply, or any other electrical component unless specifically mentioned in these instructions or shown in the included photographs and/or drawings. 7. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. TM

Upload: others

Post on 05-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

INS #

Brand Logo reversed out of black

INS #697916

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

WARNINGRisk of Electrical Shock! Disconnect power at fuse or circuit breaker before installing or servicing.

WARNINGRisk of Fire! Do not install insulation within 76 mm (3 in) of any part of the luminaire or in a way that may entrap heat.

WARNINGTo prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

WARNINGInstallation and servicing to be performed only by qualified personnel, If not qualified, consult an electrician.

WARNINGDo not energize the LED Engine until the protective covering has been removed and the lower trim properly installed. Do not touch the yellow surface of the LED as it may damage the light engine.

INS #ADP140604

Installation Instructions – LD8ART Commercial Recessed LED Retrofit Instructions d’installation – Retrofit à DEL commercial encastré LD8ART Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

otee:N This fixture should be supported by main runners or other structure that is capable of supporting fixture weight of 10 Ibs.

SAFETY: When using electrical equipment, basic safety precautions should always be followed, including the following:

1. This unit is for recessed mounting only. Do not use in hazardous locations nor near gas or electric heaters.

2. Do not use this equipment for other than the intended use.

3. Install only in accordance with National Electrical Code and local regulatory agencies’ requirements.

4. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings.

5. Installation of this retrofit assembly requires a person familiar with the construction and operation of the luminaire’s electrical system and the hazard involved. If not qualified, do not attempt installation. Contact a qualified electrician.

6. Do not alter, relocate, or remove wiring, lampholders, power supply, or any other electrical component unless specifically mentioned in these instructions or shown in the included photographs and/or drawings.

7. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components.

TM

Page 2: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

2

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

INSTALLATION

Retrofit Driver Assembly

For Horizontal Compact Fluorescent Housingse:

Installing this assembly in the ceiling1. Remove existing reflector/trim and lamp (Figure 1.).

2. Remove reflector mounting hardware from mounting bracket (Figure.2).

3. Locate junction box, remove ballast/junction box cover and disconnect supply wires (120 or 277). Disconnect connections to insulation detector if any. Disconnect all wires from the socket to the ballast (wire colors may vary) (Figure 3.).

4. Remove one 7/8” diameter (1/2” trade size conduit)knockout from junction box, on top if possible.

5. Place retrofit driver assembly through ceiling/housing opening (Figure 4.).

6. Lay retrofit driver assembly away from ceiling/housing opening with driver side up (Figure 5.).

7. Leave flexible conduits from retrofit driver assembly hanging down out of ceiling/housing opening.

8. Feed supply wires from retrofit driver assembly through knock-out that was removed in junction box and insert snap-in connector into junction box (Figure 6.).

9. Reconnect supply wires in junction box to leads from retrofit driver assembly: black wire to line, white wire to neutral, green wire to ground and any dimming leads as necessary (see Wiring Diagrams).

10. Replace ballast/junction box cover to completely close junction box.

Retro-fit Kit Contents:• Retrofit Ring Assembly

• Retrofit Driver Assembly

• ABR10 Ten-inch Adaptor Ring (optional)

• Screw Parts Bag

• Portfolio 8” LED Module (Sold Separately)

• Portfolio 8” LED Reflector (Sold Separately)

Tools Required (optional):• Philips screwdriver (from others)

• Flathead screwdriver (from others)

Figure 1. Figure 2.

Figure 3. Figure 4.

Figure 5. Figure 6.

Retrofit Ring Assembly

Screw Parts Bag

Retrofit Driver Assembly

Portfolio 8" LED Module (Sold Separately)

Portfolio 8” LED Reflector (Sold Separately)

Adapter Ring (Optional)

Page 3: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

3

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

For Vertical Compact Fluorescent Housingse:1. Remove existing reflector/trim and lamp ( Figure 7.).

2. Adjust socket bracket to highest position (Figure 8.).

3. Locate junction box, remove ballast/junction box cover and disconnect supply wires (120 or 277). Disconnect connections to insulation detector if any. Disconnect all wires from the socket to the ballast (wire colors may vary) (Figure 9.).

4. Remove one 7/8” diameter (1/2” trade size conduit) knockout from junction box, on top if possible.

5. Place retrofit driver assembly through ceiling/housing opening (Figure 10.).

6. Lay retrofit driver assembly away from ceiling/housing opening with driver side up (Figure 11.).

7. Leave flexible conduits from retrofit driver assembly hanging down out of ceiling/housing opening.

8. Feed supply wires from retrofit driver assembly through knock-out that was removed in junction box and insert snap-in connector into junction box (Figure 12.).

9. Reconnect supply wires in junction box to leads from retrofit driver assembly: black wire to line, white wire to neutral, green wire to ground and any dimming leads as necessary (see Wiring Diagrams).

10. Replace ballast/junction box cover to completely close junction box.

For HID Housingse:1. Remove existing reflector/trim and lamp (Figure 13.).

2. Adjust socket bracket to highest position (Figure 14.).

3. Locate junction box, remove ballast/junction box cover and disconnect supply wires (120 or 277). Disconnect connections to insulation detector if any. Disconnect all wires from the socket to the ballast (wire colors may vary) (Figure 15.).

4. Remove one 7/8” diameter (1/2” trade size conduit)knockout from junction box, on top if possible.

5. Place retrofit driver assembly through ceiling/housing opening (Figure 16.).

6. Lay retrofit driver assembly away from ceiling/housing opening with driver side up (Figure 17.).

7. Leave flexible conduits from retrofit driver assembly hanging down out of ceiling/housing opening.

8. Feed supply wires from retrofit driver assembly through knock-out that was removed in junction box and insert snap-in connector into junction box (Figure 18.).

9. Reconnect supply wires in junction box to leads from retrofit driver assembly: black wire to line, white wire to neutral, green wire to ground and any dimming leads as necessary (see Wiring Diagrams).

10. Replace ballast/junction box cover to completely close junction box.

Figure 7. Figure 8.

Figure 9. Figure 10.

Figure 11. Figure 12.

Figure 13. Figure 14.

Figure 15. Figure 16.

Figure 17. Figure 18.

3

2

1

Page 4: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

4

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

For Incandescent Housingse:1. Remove existing reflector/trim and lamp (Figure 19.).

2. Adjust socket bracket to highest position.

3. Locate junction box, remove cover and disconnect supply wires (120 or 277). Disconnect connections to insulation detector if any (Figure 20.).

4. Remove one 7/8” diameter (1/2” trade size conduit)knockout from junction box, on top if possible.

5. Place retrofit driver assembly through ceiling/housing opening (Figure 21.).

6. Lay retrofit driver assembly away from ceiling/housing opening with driver side up (Figure 22.).

7. Leave flexible conduits from retrofit driver assembly hanging down out of ceiling/housing opening.

8. Feed supply wires from retrofit driver assembly through knock-out that was removed in junction box and insert snap-in connector into junction box (Figure 23.).

9. Reconnect supply wires in junction box to leads from retrofit driver assembly: black wire to line,white wire to neutral, green wire to ground (see Wiring Diagrams).

10. Replace ballast/junction box cover to completely close junction box.

Retrofit Ring Assembly Installation1. Slide Adapter Band Ring (optional) over Retrofit Ring

Assembly while holding mounting springs vertical (Figure 25.).

2. Hold 2 mounting springs vertical on same side of Retrofit Ring Assembly then insert into ceiling/housing opening (Figure 26.).

3. Use ceiling/housing opening to keep mounting springs from Step 2 vertical and push other 2 mounting springs vertical then insert into ceiling (Figure 27.).

4. Align torsion spring receivers with housing stilts (if present) and ensure that mounting springs do not contact any part of housing so mounting feet or Adapter Band Ring (if present) rest flush on ceiling. Retrofit Ring Assembly may need to be rotated to avoid interference (Figure 28.).

5. Retrofit ring can be adapted to various ceiling thicknesses and plaster frame/housing heights by using different slot locations for mounting springs. LD8ART ships with springs in upper position for a combined ceiling and housing thickness greater than 1” and no more than 2”. For ceiling/housing thicknesses between 0.5” and 1” mounting springs should be moved to lower position (Figure 29.).

Figure 19. Figure 20.

Figure 21. Figure 22.

Figure 23. Figure 24.

Figure 25. Figure 26.

Figure 27.

Figure 29.

Figure 28.

Lower Position

Upper Position

Page 5: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

5

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

Figure 37.

Figure 38.

6. To prevent movement in the housing/ceiling opening use a flat head screw driver to pry out 4 centering tabs on Retrofit Ring Assembly (Figure 30.).

Trim Installation1. Remove reflector and LED engine from protective

packaging.

2. Insert lens onto white reflector (Figure 31.).

3. Place LED Engine into Lower trim. Align trim slots with engine screw holes (Figure 32.).

4. Using provided thumb screws, securely attach lower trim to LED Engine (Figure 33.).

5. Connect LED module plug (male) with retrofit driver assembly socket (female) then latch securely (Figure 34.).

6. Install the LED Engine and trim assembly by inserting the torsion springs into the spring receivers located inside retrofit ring (Figure 35.).

7. Press LED module and reflector assembly into retrofit ring assembly until flush with ceiling (Figure 36.).

8. Restore power after installation of fixture is completed.

9. See illustration (wall wash option only) (Figure 37.).

Housing CompatibilityMinimum installation height required is 8 inch. Ensure wiring, conduit and socket cup are moved to the side if possible.

LD8ART fits opening/aperture 8.7 inch minimum to 10 inch maximum (with optional adaptor band)• Cooper Lighting: C8X, PD8X, C9X.

Clean Trims1. Gently wipe with soft, clean,dry lint-free cloth to

remove dust.

2. Wipe with mild detergent solution on a soft, clean cloth to remove fingerprints and stains.

3. Rinse with clean water and dry with soft, clean,dry lint-free cloth.

Driver Replacement

CAUTIONTo avoid possible electrical shock, be sure that the power is turned off before installing or servicing this fixture.

• The driver should be replaced by a qualified electrician.

• The driver may be replaced either from below or above the ceiling.

1. Remove trim and LED module assembly from the housing (Figure 38.).

Figure 30. Figure 31.

Figure 32. Figure 33.

Figure 34.

Powerplug® Luminaire Disconnect

Locking Lever

Locking Feature

Hook

Figure 35. Figure 36.

Align

Driver Cover

Kicker

Junction Box Cover

Wall

Page 6: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

6

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

Electrical Wiring DiagramsD010TE (See website for availability)

D010 D010TR (See website for availability)

DE010 (See website for availability) (option 1)

DE010 (See website for availability) (option 2)

D5LT (See website for availability)

DMX (See website for availability)

RED FOR 277V BLACK FOR 120V

BLK

P-NUT

P-NUT

P-NUT

P-NUT

P-NUT

P-N

UT

P-N

UT

P-N

UT P-

NU

T

P-N

UT

P-NUT

P-N

UT

P-NUT

BLK

/W

BLK

/W

RE

D/W

RED/W

WHTBLK

BLK BLK

BLK

BLK

BLK BLK

CONDUIT

CONNECTOR

4 4

22

5 5

1 1

DR

V 1

DR

V 2

RED

RED

RE

D

RE

DR

ED

RED

BLK

BLK

BLK BROWN

WHT WHT

WHT BLUE

WHITE

GRAY

GRAY GRAY

GRAY GRAY

VIOLET

VIOLETVIO

VIOLET VIOLET

BLACK FOR 277V BLUE FOR 120V

+

+

-

-

LED

1LE

D 2

RED FOR 277V BLACK FOR 120V

P-NUT

P-NUT

P-N

UT P-

NU

T

P-N

UT

P-N

UT P-

NU

T BLK

/W

RE

D/W

RE

D/W

P-N

UT

P-N

UT

P-N

UT

CONDUIT

WHT P-NUT

P-NUT

P-NUT

BLK BLK

BLK BLK

BLK

CONNECTOR

BLK

BLK

BLK

BLK

RED RE

D RE

D

1 1

4 4

22

55

DR

V 1

DR

V 2

RED

RED

RED

BLK

BLK

BLK BLK

WHT WHT

WHT WHT

WHITE

GRAY

GRAY GRAY

GRAY GRAY

VIOLET

VIOLET VIOLET

VIOLET VIOLET

BLACK FOR 277V BLUE FOR 120V

+

+

-

-

LED 2

LED 1

RED FOR 277V BLACK FOR 120V

BLACK FOR 277V BLUE FOR 120V

BLK

P-NUT

P-NUT

P-N

UT

P-NUT

P-NUT

P-N

UT P-

NU

T

P-N

UT P-

NU

T P-N

UT

BLK

/W

BLK

/W

RED/W

RED/W

WHT

BLK

BLK BROWN

BLK

BLK

BLK

CONDUIT

CONNECTOR

4 4

22

5 5

1 1

DR

V 1

DR

V 2

RED

RE

D

RED

RE

D

RED

BLK

BLK

BLK BROWN

WHT BLUE

WHT BLUE

WHITE

GRAY

GRAY

GRAY

GRN

GRN

GRN

GRN

AIN-(0-10V)

AIN-(0-10V)

VIOLET

GRN/BARE

VIOLET

VIOLET AIN+(0-10V)

AIN+(0-10V)

+

+

-

-

LED 1

LED 2

RED FOR 277V BLACK FOR 120V

BLACK FOR 277V BLUE FOR 120V

P-NUT

P-NUT P-NUT

P-N

UT P-

NU

T

P-N

UT

P-N

UT

P-N

UT

P-N

UT

BLK

BLK

/W

BLK

/W

RED/W

RED/W

P-N

UT

P-N

UTWHT

P-NUTP-NUT

P-NUT

BLK BLK

BLK BLK

BLUECONDUIT

CONNECTOR

BLUE BLK

REDRED

RED

RE

D

1 1

4 4

22

5 5

DR

V 1

DR

V 2

RED RED

BLK

BLK

BLK

BLK BLK

WHT WHT

WHTWHT

GRN

GRN

WHITE

GRAY

GRAY GRAY

GRAYGRAY

VIOLET

VIOLET VIOLET

VIOLET VIOLET

TO GROUND

LED 2

LED 1

RED FOR 277V BLACK FOR 120V BLACK FOR

277V BLUE FOR 120V

BLK

P-NUT

P-NUT

P-NUT

P-NUT

P-NUT

P-N

UT

P-N

UT P-

NU

T P-N

UT

P-N

UT

BLK

/W

BLK

/W

RED/W

RED/W

WHTBLK

BLK

BLK B

LK

CONDUIT

CONNECTOR

4 4

22

5 5

1 1

DR

V 1

DR

V 2

RE

D

RED

RE

D

RE

D

RED

BLK

BLK

BLK

BLK

BROWN

BROWN

WHT

WHT

BLUE

BLUE

WHITE

GRN/BARE

GRN

GRN

GRN

GRN

DA-

DA-

VIOLET

VIOLET/WH

VIOLET/WHT

VIOLET/WHT

VIOLET

VIOLETDA+

DA+

LED 1

LED 2

RED FOR 277V BLACK FOR 120V

BLACK FOR 277V BLUE FOR 120V

P-NUT

P-N

UT

P-N

UT

P-N

UT

P-N

UT P-

NU

TP-

NU

T

BLK

/W

RED/W

BLK

/W RED/W

WHT P-NUT

P-NUT

+

+

+

+

+

+

-

-

-

-

-

-

P-NUT

BLK BLK

CONDUIT

CONNECTOR

BLK

RED

11

4 4

22

5 5

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

RE

D

RED

BLK

BLK

BLK

BLK

BLK

BROWN

BROWN

DMX IN +

DMX IN +

DMX IN -

DMX IN -

DMX IN SHIELD

DMX IN SHIELD

WHT

WHT

BLUE

BLUE

WHITE

BROWN

ORG/WHT

OR

G/W

HT

GRN

GRN

GRN

GRN

ORANGE

ORANGE/WHITE

GRN/BARE

ORG

ORG

BRO/W

BR

O/W

2. Remove the driver and junction box cover assembly.

3. Disconnect the wiring to the driver by undoing the wire nuts.

4. Discard the old driver and junction box cover assembly.

5. Connect the new driver leads with the wire nuts.

6. Reattach the new driver and junction box cover assembly.

Page 7: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

7

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

RED FOR 277V BLACK FOR 120V

BLACK FOR 277V BLUE FOR 120V

DL3 (See website for availability)

BLK

P-NUT

P-NUT

P-NUT

P-NUT

P-NUT

P-N

UT P-

NU

TP-

NU

T P-N

UT P-

NU

TP-

NU

T

BLK

/W

RED/W

WHT

+

+

-

-

BLK

BLK BLK

BLK

BLK

BLK

CONDUIT

CONNECTOR

4 4

22

5 5

1 1

DR

V 1

LED 1

LED 2

DR

V 2

RED/W

RED

RE

D

RE

D

RED

BLK

BLK

BLK

ORA

ORA

ORANGE

ORANGE

WHITE

GRN

GRN

GRN

GRNVIOLET

VIOLET/WHT

GRN/BARE

ORANGE

WHT

WHT

WHT

WHT

VIO/WHT

VIO/WHT

VIOLET

VIOLET

VIOLET

VIOLET

VIOLET

VIOLET

D010TEEMBOD (See website for availability)

RED FOR 277V BLACK FOR 120V

BLACK-120V ORG-277V

1T5

UNSWITCHED HOT

UNSWITCHED HOT

P-NUT

P-N

UT

P-N

UTP-

NU

T

P-NUT BLK

/W

BLK

/W

RED/W

RED/WRE

D/W

P-NUTP-NUT

P-N

UT

WHT

P-NUT

+

+

+

+

-

-

-

-

ALL

ALL

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTOR

BLK

BLK

RED

11

4 4

2 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

BLK

BLK

BLKBLK

WHT

WHT

WHITE

SW HOT

GRAY

GRAY

GRAY GRAY

GRAY

VIOLET

VIOLET

VIOLET VIOLET

VIOLET

BROWN

BR

OW

NV

IOLE

T

WH

ITE

WH

ITE

WH

T/R

ED

RE

D

WH

T/B

LK

ORG/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LK

BLU

E

WHITE

BLUE

BLACK FOR 277V BLUE FOR 120V

BLACK-120V ORG-277V

1T5

P-N

UT

P-N

UTP-

NU

T

P-NUT

BLK

/WBLK

/W RED/W

RED/WP-NUT

P-NUT

P-NUTP-NUT

P-NUT

+

+

+

+

-

-

-

-

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTOR

BLK

RED

11

4 4

2 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

BLK

BLKBLK

BLK

BLKBLK

RE

D

WHTWHT

WHT

WHT

GRAYGRAY

GRAY GRAY

VIOLETVIO

VIOLET VIOLET

BR

OW

NV

IOLE

T

WH

ITE

WH

ITE

WH

T/R

ED

RE

D

WH

T/B

LK

ORG/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LK

BLU

E

WHITEBLACK FOR 277V BLUE FOR 120V

RED FOR 277V BLACK FOR 120V

D010TREMBOD (See website for availability)

RED FOR 277V BLACK FOR 120V

BLACK-120V ORG-277V 1T5

UNSWITCHED HOT

P-NUT

P-N

UT

P-N

UT

P-N

UTP-

NU

TP-NUT BLK

/WBLK

/WR

ED

/W

RED/WP-NUT

P-NUT

P-NUT

WHT

P-NUT

P-NUT

+

+

+

+

-

-

-

-

ALL

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTOR

BLK

RE

D

11

4 42 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

BLK

BLK

BLK

WHT

WHITEGREEN

SW HOT

GRAY

GRAY

GRAY

VIOLET

VIO

VIOLET

BR

OW

NV

IOLE

T

WH

ITE

WH

ITE

WH

T/R

ED

RE

D

WHT/BLK

ORG/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LKBLUE

WHITEBLACK FOR 277V BLUE FOR 120V

DE010EMBOD (See website for availability) (option 1)

GRN

GRN GRN

GRN

0-10-

0-10-

0-10+

0-10+

BROWN

BROWN

BLUE

BLUE

RED FOR 277V BLACK FOR 120V

BLACK-120V ORG-277V

1T5

UNSWITCHED HOT

P-NUTP-

NU

TP-N

UT

P-N

UT

P-N

UT

P-NUT

BLK

/W

BLK/W

RED/W

RE

D/W

P-NUTP-NUT

P-NU

T

WHT

P-NUT

P-NUT

+

+

+

+

-

-

-

-

ALL

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTOR

BLKBLK

RE

D

RED

RE

D

BLU

E

11

4 4

2 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

BLK

BLK

BLK

BLK

WHT WHT

WHITE

SW HOT

GRAY

GRAY GRAY

GRAY GRAY

VIOLET

VIO VIO

VIO VIO

BR

OW

NV

IOLE

T

WH

ITE

WH

ITE

WH

T/R

ED

RE

D

WHT/BLK

ORG/BLK

ORG/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LKBLUE

WHITE WHT

BLACK FOR 277V BLUE FOR 120V

GRN

GRN

BLUE

DE010EMBOD (See website for availability) (option 2)

TO GROUND

RED FOR 277V BLACK FOR 120V

BLACK-120V ORG-277V 1T5

UNSWITCHED HOT

P-NUT

P-N

UT

P-N

UT

P-N

UTP-

NU

T

P-NUT

BLK

/WBLK

/W

RE

D/W

RED/WRE

D/W

P-NUTP-NUT

P-N

UT

WHT

P-NUT

P-NUT

+

+

+

+

-

-

-

-

ALL

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTOR

BLK

RED

11

4 4

2 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

BLK

BLK

BLK BROWN

WHT BLUE

WHITE

GREEN

SW HOT

DA-

DA-

VIOLET/WHTVIOLET

VIOLET

VIO/WHT DA+

DA+VIOLET/WHT

VIOLET

BR

OW

N

VIO

LET

WH

ITE

WH

ITE

WH

T/R

ED

RE

D

WHT/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LK

BLU

E

WHITE BLUE

BLACK FOR 277V BLUE FOR 120V

GREEN GRN

GRN GRN

BROWN

D05LTEMBOD (See website for availability)

WHITE

SW HOT

GRAYVIOLET

Page 8: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

8

LD8ART Commercial Recessed LED Retrofit

LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 www.eaton.com

DimmingThe Portfolio LD8*DO1OTE/D010TR Series can be dimmed with many standard 120V incandescent and electronic low voltage dimmers. The Portfolio LD8*DL3 Series can be dimmed with Lutron 3 wire fluorescent dimming controls. The Portfolio LD8*D010 / DE010 / D010TE / D010TR Series can be dimmed with 0-10V DC dimming controls. The Portfolio LD4*D010/LD6*D010 Series are NOT to be dimmed using line voltage dimmers. To be assured of the latest information regarding luminaire and dimmer compatibility, please reference the Portfolio LED website: www.portfolio-lighting.com

RED FOR 277V BLACK FOR 120V

BLACK-120V ORG-277V 1T5

UNSWITCHED HOT

P-NUT

P-N

UT

P-N

UT

P-N

UT

P-N

UT

P-N

UT

P-N

UT B

LK/W

BLK

/WR

ED

/W

RE

D/W

RED/W

P-NUT

P-NUTP-NUT

P-NUT

+

+

+

+

-

-

-

-

ALL

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTOR

BLK

RE

D

11

4 4

2 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

BLK

BLK

BLK BROWN

WHT BLUE

WHITEGREEN

SW HOT

ORANGE/WHITE

ORANGEBROWN/WHT

BR

OW

NV

IOLE

T

WH

ITE

WH

ITE

WH

T/R

ED

RE

D

WHT/BLK

ORG/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LKBLUE

WHITE BLUEBLACK FOR 277V BLUE FOR 120V

GREEN GRN

GRN GRN

BROWN

DMXEMBOD (See website for availability)

BROWN/WHT

BRN/WHT

DMX IN SHIELD

DMX IN SHIELD

DMX IN+

DMX IN+

DMX IN-

DMX IN-

ORG/WHT

ORG/WHT

ORANGE

ORANGE

RED FOR 277V BLACK FOR 120V

BLACK-120V ORG-277V

1T5

UNSWITCHED HOT

P-NUT

P-N

UT

P-N

UT

P-NUT

P-N

UT

P-N

UTP-

NU

T

BLK

/W

BLK

/W

RED/W

RE

D/W

RED/WP-NUTP-NUT

P-N

UT

WHT

P-N

UT

P-NU

T

+

+

+

+

-

-

-

-

ALL

FLEX CONDUIT

FLEX CONDUIT 1

FLEX CONDUIT 2

EMERGENCY LED DRIVER

CONNECTORRE

D

11

4 4

2 2

55

DR

V 1

LED 1

LED 2

DR

V 2

RE

D

WHITE

GREEN

SW HOT

VIOLET/WHT

ORANGE

VIOLET

BR

OW

NV

IOLE

T

WH

ITE

WHITE

WH

T/R

ED

RE

D

WHT/BLKORG/BLK

ORG/BLK

YE

LLO

W

YE

L/B

LK

BLUE

BLACK FOR 277V BLUE FOR 120V

DL3EMBOD (See website for availability)

BLK

BLK

BLK BLK

BLK

BLK

ORANGE

ORANGE

WHT

WHT

WHT

WHT

GRN

GRN

GRN

GRN

VIOLET

VIOLET

VI0

VI0VI0

VI0

VIO/WHT

VIO/WHT

Page 9: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

9

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

IMPORTANT: Lisez attentivement avant d'installer le luminaire. Conservez pour une référence future.

AVERTISSEMENTRisque de décharge électrique! Mettez l’alimentation électrique hors tension en enlevant le fusible ou en déclenchant le disjoncteur avant l'installation ou l'entretien.

AVERTISSEMENTRisque d'incendie! N’installez aucune isolation à moins de 3 po (76 mm) de toute partie du luminaire ou de manière à ce que soit emprisonnée la chaleur.

AVERTISSEMENTAfin d’éviter l’endommagement ou l’usure du câblage, évitez que les câblages soient en contact avec les bords des feuilles de métal ou tout autre objet tranchant.

AVERTISSEMENTL'installation ou l'entretien ne doit être effectué que par du personnel qualifié. Si vous n'avez pas les compétences nécessaires, faites appel à un électricien.

AVERTISSEMENTN'alimentez pas la DEL avant que le revêtement protecteur ait été retiré et que la garniture inférieure ait été installée. Ne touchez pas à la surface jaune de la DEL puisque cela pourrait endommager le moteur lumineux.

otee:N Le luminaire devrait être soutenu par des rails porteurs ou toute autre structure en mesure de supporter un poids de 4,5 kg (10 lb).

SÉCURITÉ: Lorsque vous utilisez un appareil électrique, vous devez toujours respecter les mesures de sécurité de base, y compris les suivantes:

1. Ce modèle est destiné à un montage encastré seulement. Ne l'utilisez pas dans des endroits dangereux ou à proximité d'éléments chauffants électriques ou à gaz.

2. N'utilisez pas cet équipement à d'autres fins que celles prévues.

3. Installez l'appareil conformément aux exigences du Code national de l'électricité et des organismes de réglementation locaux.

4. N’installez cet ensemble que dans les luminaires dotés des dimensions et des caractéristiques de construction présentées sur les photos ou les schémas.

5. Ce produit doit être installé par une personne qui connaît bien la construction et le mode de fonctionnement du système électrique du luminaire et qui est consciente des dangers qui y sont rattachés. Si vous n'avez pas les compétences nécessaires, n’en tentez pas l'installation. Contactez un électricien qualifié.

6. Ne modifiez pas, ne changez de place ou ne retirez pas le câblage, les douilles de lampe, la source d’alimentation ou toute autre composante électrique, à moins que les présentes instructions ne le mentionnent ou que la marche à suivre soit expliquée dans les photos ou les schémas.

7. Seuls les trous indiqués dans les photos ou les schémas peuvent être faits ou modifiés pendant l’installation de l'ensemble. Ne laissez aucun autre trou à découvert dans un boîtier de câblage ou dans des composantes électriques.

Ensemble d'anneaux RetrofitSac de vis

Ensemble de pilote Retrofit

Module DEL Portfolio de 20,3 cm (8 po) (Vendu séparément)

Réflecteur DEL Portfolio de 20,3 cm (8 po) (Vendu séparément)

L’ensemble Retrofit comprend:• Ensemble d'anneaux Retrofit

• Ensemble de pilote Retrofit

• Anneau d'adaptation 25,4 cm (10 po) ABR10 (en option)

• Sac de vis

• Module DEL Portfolio de 20,3 cm (8 po) (Vendu séparément)

• Réflecteur DEL Portfolio de 20,3 cm (8 po) (Vendu séparément)

Outils nécessaires (facultatif):• Tournevis étoile (entre autres)

• Tournevis à tête plate (entre autres)

Anneau Adaptateur (En Option)

Page 10: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

10

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

INSTALLATION

Ensemble de pilote Retrofit

Pour les boîtiers de fluorescents compacts horizontauxe:

Installez cet assemblage au plafond1. Retirez le réflecteur ou la garniture et l’ampoule

(Figure 1.).

2. Retirez le matériel de montage du réflecteur du crochet de montage (Figure 2.).

3. Identifiez la boîte de jonction, retirez le ballast et le couvercle de la boîte de jonction et débranchez les câbles d’alimentation (120 ou 277). Débranchez les fils du détecteur d’isolation, s’il y a lieu. Débranchez tous les câbles qui relient la douille au ballast (la couleur des câbles peut varier) (Figure 3.).

4. Retirez une entrée défonçable d'un diamètre de 7/8 po (conduit d'une taille de 1/2 po) dans la boîte de jonction, si possible sur le dessus de cette dernière.

5. Installez le circuit de sortie de manière à ce qu’il passe à travers le plafond et par l’ouverture du boîtier (Figure 4.).

6. Éloignez le circuit de sortie de l’ouverture du plafond ou du boîtier en le laissant tourné vers le haut (Figure 5.).

7. Laissez pendre les conduits flexibles du circuit de sortie par l'ouverture du plafond ou du boîtier.

8. Alimentez les câbles d’alimentation à partir du circuit de sortie en passant par l'entrée défonçable qui a été retirée dans la boîte de jonction, et insérez le connecteur à pression à l’intérieur de la boîte de jonction (Figure 6.).

9. Rebranchez les câbles d'alimentation aux conducteurs de l'assemblage pilote retrofit dans la boîte de jonction : le câble noir à la ligne, le câble blanc au neutre, le câble vert à la terre et tout autre conducteur de gradation, si nécessaire (voir le schéma de câblage).

10. Replacez le ballast ou le couvercle de la boîte de jonction afin de refermer complètement la boîte de jonction.

Pour les boîtiers de fluorescents compacts verticauxe:1. Retirez le réflecteur ou la garniture et l’ampoule

(Figure 7.).

2. Réglez le support à douille à la position la plus haute (Figure 8.).

3. Identifiez la boîte de jonction, retirez le ballast et le couvercle de la boîte de jonction et débranchez les câbles d’alimentation (120 ou 277). Débranchez les fils du détecteur d’isolation, s’il y a lieu. Débranchez tous les câbles qui relient la douille au ballast (la couleur des câbles peut varier) (Figure 9.).

Figure 1. Figure 2.

Figure 3. Figure 4.

Figure 5. Figure 6.

Figure 7. Figure 8.

4. Retirez une entrée défonçable d’un diamètre de 7/8 po (conduit d’une taille de 1/2 po) dans la boîte de jonction, si possible sur le dessus de cette dernière.

5. Installez le circuit de sortie pour qu’il passe à travers le plafond et par l’ouverture du boîtier (Figure 10).

Figure 9. Figure 10.

3

2

1

Page 11: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

11

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

6. Éloignez le circuit de sortie de l'ouverture du plafond ou du boîtier en le laissant tourné vers le haut (Figure 11.).

7. Laissez pendre les conduits flexibles du circuit de sortie par l'ouverture du plafond ou du boîtier.

8. Alimentez les câbles d’alimentation à partir du circuit de sortie en passant par l’entrée défonçable qui a été retirée dans la boîte de jonction, et insérez le connecteur à pression à l’intérieur de la boîte de jonction (Figure 12.).

9. Rebranchez les câbles d'alimentation aux conducteurs de l'assemblage pilote retrofit dans la boîte de jonction : le câble noir à la ligne, le câble blanc au neutre, le câble vert à la terre et tout autre conducteur de gradation, si nécessaire (voir le schéma de câblage).

10. Replacez le ballast ou le couvercle de la boîte de jonction afin de refermer complètement la boîte de jonction.

Pour les boîtiers HIDe:1. Retirez le réflecteur, la garniture et l'ampoule

(Figure 13.).

2. Réglez le support à douille à la position la plus haute (Figure 14.).

3. Identifiez la boîte de jonction, retirez le ballast et le couvercle de la boîte de jonction et débranchez les câbles d’alimentation (120 ou 277). Débranchez les fils du détecteur d’isolation, s’il y a lieu. Débranchez tous les câbles qui relient la douille au ballast (la couleur des câbles peut varier) (Figure 15.).

4. Retirez une entrée défonçable d'un diamètre de 7/8 po (conduit d'une taille de 1/2 po) dans la boîte de jonction, si possible sur le dessus de cette dernière.

5. Installez le circuit de sortie pour qu’il passe à travers le plafond et par l’ouverture du boîtier (Figure 16.).

6. Éloignez le circuit de sortie de l’ouverture du plafond ou du boîtier en le laissant tourné vers le haut (Figure 17.).

7. Laissez pendre les conduits flexibles du circuit de sortie par l'ouverture du plafond ou du boîtier.

8. Alimentez les câbles d’alimentation à partir du circuit de sortie en passant par l’entrée défonçable qui a été retirée dans la boîte de jonction, et insérez le connecteur à pression à l’intérieur de la boîte de jonction (Figure 18.).

9. Rebranchez les câbles d’alimentation aux conducteurs de l’assemblage pilote retrofit dans la boîte de jonction : le câble noir à la ligne, le câble blanc au neutre, le câble vert à la terre et tout autre conducteur de gradation, si nécessaire (voir le schéma de câblage).

10. Replacez le ballast ou le couvercle de la boîte de jonction afin de refermer complètement la boîte de.

Figure 11. Figure 12.

Figure 13. Figure 14.

Figure 15. Figure 16.

Figure 17. Figure 18.

Pour les boîtiers incandescentse:1. Retirez le réflecteur, la garniture et l'ampoule

(Figure 19.).

2. Réglez le support à douille à la position la plus haute.

3. Identifiez la boîte de jonction, retirez le ballast et le couvercle de la boîte de jonction et débranchez les fils d’alimentation (120 ou 277). Débranchez les fils du détecteur d’isolation, s’il y a lieu (Figure 20.).

Figure 19. Figure 20.

Page 12: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

12

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

Figure 21. Figure 22.

Figure 23. Figure 24.

Figure 25. Figure 26.

Figure 27. Figure 28.

Figure 29.

Orientation vers le bas

Orientation vers le haut

4. Retirez une entrée défonçable d'un diamètre de 7/8 po (conduit d'une taille de 1/2 po) dans la boîte de jonction, si possible sur le dessus de cette dernière.

5. Installez le circuit de sortie de manière à ce qu'il passe à travers le plafond et par l'ouverture du boîtier (Figure 21.).

6. Éloignez le circuit de sortie de l'ouverture du plafond ou du boîtier en le laissant tourné vers le haut (Figure 22.).

7. Laissez pendre les conduits flexibles du circuit de sortie par l'ouverture du plafond ou du boîtier.

8. Alimentez les câbles d'alimentation à partir de l'assemblage pilote retrofit en passant par l'entrée défonçable qui a été retirée dans la boîte de jonction, et insérez le connecteur à pression à l'intérieur de la boîte de jonction (Figure 23.).

9. Rebranchez les câbles d'alimentation aux conducteurs de l'assemblage pilote retrofit dans la boîte de jonction : le câble noir à la ligne, le câble blanc au neutre, le câble vert à terre (voir le schéma de câblage).

10. Replacez le ballast ou le couvercle de la boîte de jonction afin de refermer complètement la boîte de jonction.

Installation de l'assemblage d'anneaux Retrofit1. Faites glisser la bague à bande d'adaptation (en option)

sur l'assemblage d'anneaux Retrofit tout en maintenant les ressorts de fixation à la verticale (Figure 25.).

2. Maintenez les 2 ressorts de fixation à la verticale du même côté de l'assemblage d'anneaux Retrofit, puis insérez-les dans l'ouverture du plafond/boîtier (Figure 26.).

3. Utilisez l'ouverture du plafond/boîtier pour maintenir les ressorts de fixation à l'étape 2 à la verticale. Poussez les 2 autres ressorts de fixation à la verticale, puis insérez-les dans le plafond (Figure 27.).

4. Alignez les receveurs de ressorts de torsion avec les glissières du boîtier (s'il y en a) et assurez-vous que les ressorts de fixation ne touchent aucune partie du boîtier pour que les pattes de montage ou la bague à bande d'adaptation (s'il y en a) reposent à plat sur le plafond. Les anneaux Retrofit auront peut-être besoin d'être tournés pour éviter des interférences (Figure 28.).

5. L'anneau Retrofit peut être adapté à différentes épaisseurs de plafond et à des hauteurs de cadre de plâtre ou de boîtier en utilisant différentes fentes pour les ressorts de fixation. Le dispositif LD8ART est expédié avec des ressorts orientés vers le haut pour une épaisseur de plafond et de boîtier supérieure à 2,5 cm (1 po) et de 5 cm (2 po) maximum. Pour des épaisseurs de plafond et de boîtier comprises entre 12,7 mm (0,5 po) et 2,5 cm (1 po), les ressorts de fixation doivent être orientés vers le bas (Figure 29.).

Page 13: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

13

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

6. Pour éviter un déplacement dans l'ouverture du boîtier/plafond, utilisez un tournevis à tête plate pour dégager les 4 languettes de centrage sur l'assemblage d'anneaux Retrofit (Figure 30.).

Installation de la garniture1. Retirez le réflecteur et le moteur lumineux à DEL de

leur emballage de protection.

2. Insérez la lentille dans le réflecteur blanc (Figure 31.).

3. Insérez le moteur lumineux à DEL dans la garniture inférieure. Alignez les fentes de la garniture aux trous de vis du moteur (Figure 32.).

4. À l'aide des vis à oreilles fournies, attachez solidement la garniture inférieure au moteur lumineux à DEL (Figure 33.).

5. Connectez la prise (mâle) du module à DEL à la douille (femelle) de l'assemblage du pilote Retrofit, puis verrouillez (Figure 34.).

6. Installez le moteur lumineux à DEL et l'assemblage de la garniture en insérant les ressorts de torsion dans les receveurs de ressorts qui se trouvent à l'intérieur de l'anneau Retrofit (Figure 35.).

7. Enfoncez le module à DEL et l'assemblage du réflecteur dans l'assemblage de l'anneau Retrofit jusqu'à ce qu'ils soient au même niveau que le plafond (Figure 36.).

8. Rétablir l'électricité dès que l'installation du luminaire est terminée.

9. Consultez l'illustration (option de lèche-mur uniquement) (Figure 37.).

Compatibilité de boîtierHauteur minimale de 20,3 cm (8 po) requise pour l'installation. Assurez-vous que le câblage, le conduit et le boîtier de douille soient si possible déplacés vers le côté.

LD8ART s’adapte ouverture / ouverture de 8,7 cm minimum à 10 cm au maximum (avec bande adaptateur en option)• Cooper Lighting: C8X, PD8X, C9X.

Nettoyage des garnitures1. Essuyez doucement avec un chiffon non pelucheux

doux, propre et sec pour enlever la poussière.

2. Frottez avec un chiffon doux et propre imbibé de détergent doux pour enlever les empreintes de doigts et les taches.

3. Rincez à l'eau propre puis séchez avec un chiffon doux, propre, sec et non pelucheux.

Figure 30. Figure 31.

Figure 32. Figure 33.

Figure 34.

Figure 35.

Prise de débranchement rapide de luminaire Powerplug®

Levier de blocage

Caractéristique de blocage

Crochet

Figure 36.

Figure 37.

Alignement

Projecteur de décollement

Mur

Page 14: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

14

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

Remplacement du pilote

MISE EN GARDEPour éviter toute décharge électrique, assurez-vous que l'alimentation est hors tension avant de procéder à l'installation ou à l'entretien de ce luminaire.

• Le pilote doit être remplacé par un électricien qualifié.

• Le pilote peut être remplacé à partir du dessus ou du dessous du plafond.

1. Retirez l’assemblage de la garniture et du module à DEL du boîtier (Figure 38.).

2. Retirez l’assemblage du pilote et du couvercle de la boîte de jonction.

3. Déconnectez le câblage du pilote en enlevant les serre fils. Figure 38.

Couvercle du pilote

Couvercle de la boîte de jonction

4. Jetez l’assemblage de l’ancien pilote et du couvercle de la boîte de jonction.

5. Connectez les fils du nouveau pilote aux serre-fils.

6. Rattachez le nouvel assemblage du pilote et du couvercle de la boîte de jonction.

Schémas de câblage électriqueD010TE (consultez le site Web pour connaître la disponibilité)

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR

ÉCROU P

ÉCROU P

ÉCROU P

ÉC

RO

U P

ÉCROU P

ÉC

RO

U P ÉC

RO

U P

ÉC

RO

U P ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉCROU P

ÉCROU P

NO

IR A

VE

C

NO

IR A

VE

CROUGE AVEC

ROUGE AVEC

BLANC

+

+

-

-

NOIR

NOIR NOIR

NOIR

NO

IR

NOIR

NO

IR

CONDUIT

CONNECTEURS

4 4

22

5 5

1 1

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

ROUGE

RO

UG

ER

OU

GE

RO

UG

E

RO

UG

E

ROUGE

NOIR

NO

IR

NOIR MARRON

BLANCBLANC

BLANC BLEU

BLANC

GRIS

GRIS GRIS

GRIS GRIS

VIOLET

VIO

LET

VIOLET

VIOLET VIOLET

NOIR POUR BLEU DE 277 V POUR 120 V

D010 D010TR (consultez le site Web pour connaître la disponibilité)

ROUGE POUR NOIR DE 277 V POUR 120 V

ÉCROU P

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉCROU P

NO

IR A

VE

C

RO

UG

E A

VE

C

ÉC

RO

U P

ÉCROU P

ÉCROU P

BLANC ÉCROU P

ÉCROU P

+

+

-

-

ÉCROU P

NOIRNOIR

NOIR NOIR

NOIR

CONDUIT

CONNECTEURS

NOIR NOIRN

OIR

ROUGE RO

UG

ER

OU

GE

1 1

4 4

22

55

GU

LATE

UR

1

DEL 1

DEL 2

GU

LATE

UR

2

ROUGE

RO

UG

E

ROUGE

NOIR

NO

IR

NOIR NOIR

BLANC BLANC

BLANC BLANC

BLANC

GRIS

GRIS GRIS

GRIS GRIS

VIOLET

VIOLET VIOLET

VIOLET VIOLET

NOIR POUR BLEU DE 277 V POUR 120 V

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR POUR BLEU DE 277 V POUR 120 V

DE010 (consultez le site Web pour connaître la disponibilité) (option 1)

NOIR

ÉCROU P

ÉCROU P

ÉCROU P

ÉCROU P

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

C

RO

UG

E A

VE

C

ROUGE AVEC

BLANC

+

+

-

-

NOIR

NOIR MARRON

NOIR

NO

IR

NO

IR

CONDUIT

CONNECTEURS

4 4

22

5 5

1 1

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

ER

OU

GE

RO

UG

E

RO

UG

E

ROUGE

NOIR

NO

IR

NOIR MARRON

BLANC BLEU

BLANC BLEU

BLANC

GRIS

GRIS

GRIS

VERT

VERT

VERT

VERT

AIN-(0-10 V)

AIN-(0-10 V)

VIOLET

VERT/NU

VIOLET

VIOLET AIN+(0-10 V)

AIN+(0-10 V)

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR POUR BLEU DE 277 V POUR 120 V

DE010 (consultez le site Web pour connaître la disponibilité) (option 2)

ÉCROU P

ÉCROU P ÉCROU P

ÉC

RO

U P ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉCROU P

ÉC

RO

U P

NO

IR

NO

IR A

VE

C

NO

IR A

VE

C

RO

UG

E A

VE

C

RO

UG

E A

VE

C

ÉC

RO

U P

ÉCROU PBLANC

ÉC

RO

U P

ÉCROU P

+

+

-

-

ÉCROU P

NOIR NOIR

NOIR NOIR

BLEUCONDUIT

CONNECTEURS

NOIR NOIR

ROUGE RO

UG

E

RO

UG

ER

OU

GE

1 1

4 4

22

5 5

GU

LATE

UR

1

DEL 1

DEL 2

GU

LATE

UR

2

ROUGE

RO

UG

E

ROUGE

NOIR

NO

IR

NO

IR

NOIR NOIR

BLANC BLANC

BLANC BLANC

VERT

VERT

BLANC

GRIS

GRIS GRIS

GRIS GRIS

VIOLET

VIOLET VIOLET

VIOLET VIOLET

VERS MISE À LA TERRE

Page 15: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

15

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR POUR BLEU DE 277 V POUR 120 V

D5LT (consultez le site Web pour connaître la disponibilité)

NOIR

ÉCROU P

ÉCROU P

ÉCROU P

ÉCROU P ÉCROU P

ÉC

RO

U P

ÉC

RO

U P ÉC

RO

U P ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

C

ROUGE AVEC

ROUGE AVEC

BLANC

+

+

-

-

NOIR

NOIR

NO

IR

NO

IR

CONDUIT

CONNECTEURS

4 4

22

5 5

1 1

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

ER

OU

GE

RO

UG

ER

OU

GE

ROUGE

NOIR

NO

IR

NOIR

NOIR

MARRON

MARRON

BLANC

BLANC

BLEU

BLEU

BLANC

VERT/NU

VERT

VERT

VERT

VERT

DA-

DA-

VIOLET

VIOLET/BLANC

VIOLET/BLANC

VIOLET/BLANC

VIOLET

VIOLET

DA+

DA+

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR POUR BLEU DE 277 V POUR 120 V

DMX (consultez le site Web pour connaître la disponibilité)

ÉCROU P

ÉCROU P

ÉC

RO

U P É

CR

OU

P ÉC

RO

U P É

CR

OU

P

ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

RO

UG

E A

VE

C

NO

IR A

VE

C

ROUGE AVEC

BLANC ÉCROU P

ÉCROU P

+

+

-

-

ÉCROU P

NOIR NOIR

CONDUIT

CONNECTEURS

NOIR

RO

UG

E

11

4 4

2 2

5 5

GU

LATE

UR

1

DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

ROUGE

NOIR

NO

IR

NOIR

NOIR

MARRON

MARRON

DMX IN +

DMX IN +

DMX IN -

DMX IN -

DMX DANS L'ÉCRAN

DMX DANS L'ÉCRAN

BLANC

BLANC

BLEU

BLEU

BLANC

MARRON

ORANGE/BLANC

OR

G/B

LAN

C

VERT

VERT

VERT

VERT

ORANGE

ORANGE/BLANC

VERT/NU

ORANGE

ORG

MARRON/BLANC

MA

RR

ON

/B

LAN

C

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR POUR BLEU DE 277 V POUR 120 V

DL3 (consultez le site Web pour connaître la disponibilité)

NOIR

ÉCROU P

ÉCROU P

ÉCROU P

ÉCROU P

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P ÉC

RO

U P ÉC

RO

U P É

CR

OU

P ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

C

ROUGE AVEC

BLANC

+

+

-

-

NOIR

NOIR NOIR

NOIR

NOIR NO

IR

CONDUIT

CONNECTEURS

4 4

22

5 5

1 1

GU

LATE

UR

1

DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E A

VE

C

RO

UG

E

RO

UG

E

RO

UG

E

ROUGE

NOIR

NO

IR

NOIR

ORG

ORANGE

ORANGE

ORANGE

BLANC

VERT

VERT

VERT

VERTVIOLET

VIOLET/BLANC

VERT/NU

ORANGE

BLANC

BLANC

BLANC

BLANC

VIOLET/BLANC

VIOLET/BLANC

VIOLET

VIOLET

VIOLET

VIOLET

VIOLET

VIOLET

D010TEEMBOD (consultez le site Web pour connaître la disponibilité)

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V

1T5

SOUS TENSION DÉBRANCHÉ

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

C ROUGE AVEC

ROUGE AVEC

ÉCROU P

ÉC

RO

U P

BLANC

ÉCROU P

ÉC

RO

U P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

NOIR

RO

UG

E

11

4 4

2 2

55

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

NOIR

NOIR

NO

IR

BLANC

BLANC

BLANC

SOUS TENSION BRANCHÉ

GRIS

GRIS

GRIS GRIS

GRIS

VIOLET

VIOLET

VIOLET VIOLET

VIOLET

MARRON

MARRON

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

RO

UG

E

BLANC/NOIR

ORANGE/NOIR

ORANGE/NOIR

JAU

NE

JAU

NE

/NO

IRBLEU

BLANC

BLEU

NOIR POUR BLEU DE 277 V POUR 120 V

Page 16: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

16

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V

1T5

SOUS TENSION DÉBRANCHÉ

ÉCROU P

ÉC

RO

U P ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

CR

OU

GE

AV

EC

RO

UG

E A

VE

C

ÉCROU P

ÉCROU P

ÉCROU P

BLANC

ÉCROU P

ÉC

RO

U P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

NOIR

NO

IRR

OU

GE

RO

UG

E

11

4 4

2 2

55

GU

LATE

UR

1

DEL 1

DEL 2R

ÉG

ULA

TEU

R 2

RO

UG

ENOIR

NOIR NOIR

NO

IR

NOIR

BLANC BLANC

BLANC

BLANC

SOUS TENSION BRANCHÉ

GRIS

GRIS

GRIS GRIS

GRIS

VIOLET

VIOLET

VIOLET VIOLET

VIOLET

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

BLA

NC

/NO

IR

OR

AN

GE

/NO

IRORANGE/NOIR

JAU

NE

JAU

NE

/NO

IR

BLE

U

BLANCNOIR POUR BLEU DE 277 V POUR 120 V

D010TREMBOD (consultez le site Web pour connaître la disponibilité)

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V 1T5

SOUS TENSION DÉBRANCHÉ

ÉCROU P

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

CR

OU

GE

AV

EC

RO

UG

E A

VE

C

ÉCROU P

ÉCROU P

ÉC

RO

U P

BLANC

ÉC

RO

U P

ÉCROU P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

NOIR

RO

UG

E

11

4 4

2 2

55

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

NOIR

NOIR

NOIR

BLANC

BLANC

VERT

SOUS TENSION BRANCHÉ

GRIS

GRIS

GRIS

VIOLET

VIOLET

VIOLET

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

BLANC/NOIR

ORANGE/NOIR

ORANGE/NOIR

JAU

NE

JAU

NE

/NO

IR

BLE

U

BLANC

NOIR POUR BLEU DE 277 V POUR 120 V

DE010EMBOD (consultez le site Web pour connaître la disponibilité) (option 1)

VERT

VERT VERT

VERT

0-10-

0-10-

0-10+

0-10+

MARRON

MARRON

BLEU

BLEU

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V

1T5

SOUS TENSION DÉBRANCHÉ

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉCROU P

NO

IR A

VE

C

NO

IR A

VE

C

ROUGE AVEC

RO

UG

E A

VE

C

RO

UG

E A

VE

C

ÉC

RO

U P

ÉCROU P

ÉCROU P

BLANC

ÉCROU P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

BLEU

BLEU

NOIR

RO

UG

E

ROUGE

ROUGE

11

4 4

2 2

55

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

NOIR

NOIR

NO

IR

NOIR

BLANC BLANC

BLANC

SOUS TENSION BRANCHÉ

GRIS

GRIS GRIS

GRIS GRIS

VIOLET

VIOLET VIOLET

VIOLET VIOLET

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

BLANC/NOIR

ORANGE/NOIR

ORANGE/NOIR

JAU

NE

JAU

NE

/NO

IRBLEU

BLANC BLANC

NOIR POUR BLEU DE 277 V POUR 120 V

VERT

VERT

BLEU

DE010EMBOD (consultez le site Web pour connaître la disponibilité) (option 2)

VERS MISE À LA TERRE

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V

1T5

SOUS TENSION DÉBRANCHÉ

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

NOIR AVECN

OIR

AV

EC

RO

UG

E A

VE

C

ROUGE AVEC

RO

UG

E A

VE

CÉC

RO

U P

ÉC

RO

U P

BLANC

ÉCROU P

ÉCROU P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

NOIR

RO

UG

E

11

4 4

2 2

55

GU

LATE

UR

1 DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

NOIR

NOIR

NOIR MARRON

BLANC BLEU

BLANC

VERT

SOUS TENSION BRANCHÉ

GRIS DA-

DA-

VIOLET/BLANC

VIOLET

VIOLET DA+

DA+VIOLET/BLANC

VIOLET

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

BLANC/NOIR

ORANGE/NOIR

ORANGE/NOIR

JAU

NE

JAU

NE

/NO

IRBLEU

BLANC BLEU

NOIR POUR BLEU DE 277 V POUR 120 V

VERT VERT

VERT VERT

MARRON

D05LTEMBOD (consultez le site Web pour connaître la disponibilité)

Page 17: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

17

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART 706240INS ADP140604 www.eaton.com

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V

1T5

SOUS TENSION DÉBRANCHÉ

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

C

ROUGE AVEC

RO

UG

E A

VE

C

RO

UG

E A

VE

CÉCROU P

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉCROU P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

NOIR

RO

UG

E

11

4 4

2 2

55

GU

LATE

UR

1

DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

NOIR

NOIR

NOIRMARRON

BLANCBLEU

BLANC

VERT

SOUS TENSION BRANCHÉ

ORANGE/BLANC

ORANGE

MARRON/BLANC

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

BLA

NC

/NO

IR

OR

AN

GE

/NO

IR

ORANGE/NOIR

JAU

NE

JAU

NE

/NO

IR

BLE

U

BLANCBLEU

NOIR POUR BLEU DE 277 V POUR 120 V

VERTVERT

VERTVERT

MARRON

DMXEMBOD (consultez le site Web pour connaître la disponibilité)

MARRON/BLANC

MARRON/BLANC

DMX DANS L'ÉCRAN

DMX DANS L'ÉCRAN

DMX IN+

DMX IN+

DMX IN-

DMX IN-

ORANGE/BLANC

ORANGE/BLANC

ORANGE

ORANGE

ROUGE POUR NOIR DE 277 V POUR 120 V

NOIR-120 V ORANGE-277 V

1T5

SOUS TENSION DÉBRANCHÉ

ÉCROU P

ÉCROU P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

ÉC

RO

U P

NO

IR A

VE

C

NO

IR A

VE

CR

OU

GE

A

VE

C

ROUGE AVEC

ROUGE AVEC

ÉCROU P

ÉCROU P

ÉCROU P

BLANC

ÉCROU P

ÉC

RO

U P

+

+

+

+

-

-

-

-

TOUT

CONDUIT FLEXIBLE

CONDUIT FLEXIBLE 1

CONDUIT FLEXIBLE 2

PILOTE À DEL DE SECOURS

CONNECTEURS

NOIR

RO

UG

E

11

4 4

2 2

55

GU

LATE

UR

1

DEL 1

DEL 2

GU

LATE

UR

2

RO

UG

E

NOIR

BLANC

VERT

SOUS TENSION BRANCHÉ

VIOLET/BLANC

ORANGE

VIOLET

MA

RR

ON

VIO

LET

BLA

NC

BLA

NC

BLA

NC

/RO

UG

E

RO

UG

E

BLA

NC

/NO

IR

OR

AN

GE

/NO

IR

ORANGE/NOIR

JAU

NE

JAU

NE

/NO

IR

BLE

U

NOIR POUR BLEU DE 277 V POUR 120 V

DL3EMBOD (consultez le site Web pour connaître la disponibilité)

NOIR

NOIR

NOIR

NOIR

ORANGE

ORANGE

BLANC

BLANC

BLANC

BLANC

VERT

VERT

VERT

VERT

VIOLET

VIOLET

VI0LET

VI0LET

VI0LET

VI0LET

VIOLET/BLANC

VIOLET/BLANC

Page 18: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

18

Instructions d’installation – Retrofit à DEL commercial encastré LD8ART

GradateurLa série LD8*DO1OTE/D010TR du portfolio peut être atténuée avec plusieurs gradateurs à incandescence standard de 120 V et des gradateurs électroniques à basse tension. La série LD8*DL3 du portfolio peut être atténuée avec les commandes de gradation Lutron fluorescentes à trois fils. La série LD8D010/DE010/D010TE/D010TR du portfolio peut être atténuée avec des commandes de gradation de 0-10 V CC.* La série LD4*D010/LD6*D010 du portfolio NE PEUT être atténuée avec des gradateurs de tension d'alimentation composée. Pour vous assurer de posséder les informations les plus récentes à propos de la compatibilité du gradateur et du luminaire, veuillez consulter le site Web du Portfolio de la DEL: www.portfolio-lighting.com

Page 19: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

19

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

IMPORTANTE: Lea atentamente antes de instalar la luminaria. Conserve estas instrucciones para tenerlas como referencia futura.

ADVERTENCIA¡Riesgo de descarga eléctrica! Desconecte la alimentación en el disyuntor o fusible antes de instalar o realizar tareas de mantenimiento.

ADVERTENCIA¡Riesgo de incendio! No instale el aislamiento a menos de 3 pulgadas (76 mm) de cualquier parte de la luminaria o de manera tal que pueda retener calor.

ADVERTENCIAPara evitar abrasiones o daños en el cableado, no exponga los cables a bordes de chapa u otros objetos filosos.

ADVERTENCIASolo personal cualificado debe realizar la instalación y el servicio de mantenimiento. Si no está cualificado, consulte con un electricista.

ADVERTENCIANo encienda el motor de la luminaria LED hasta haber quitado la funda de protección e instalado la moldura inferior correctamente. No toque la superficie amarilla del LED ya que ello puede dañar el motor de la luz.

otee:N Esta luminaria debería estar sostenida por guías u otra estructura con capacidad de sostener el peso de la luminaria de 10 libras.

SEGURIDAD: Cuando utilice equipos eléctricos, siempre debe seguir precauciones de seguridad básicas, incluidas las siguientes:

1. Esta unidad es para montaje empotrado solamente. No la utilice en ubicaciones peligrosas ni cerca de estufas de gas o eléctricas.

2. No utilice este equipo para otro fin diferente al indicado.

3. Instale únicamente de conformidad con el Código Eléctrico Nacional y los requerimientos de las agencias regulatorias locales.

4. Instale este kit solo en las luminarias que tengan las dimensiones y características estructurales que se muestran en las fotografías o los diagramas.

5. Una persona con conocimientos sobre la construcción y el funcionamiento del sistema eléctrico de la luminaria y los riesgos implicados debe instalar esta unidad adaptadora (retrofit). Si usted no está calificado para hacerlo, no intente realizar la instalación. Contacte a un electricista cualificado.

6. No modifique, reubique ni extraiga los cables, los portalámparas, la fuente de alimentación o todo otro componente eléctrico, a menos que así se haya mencionado específicamente en estas instrucciones o que aparezca en las fotografías o diagramas incluidos.

7. Por la instalación del kit, solo se podrán hacer o modificar aquellos orificios abiertos que están indicados en las fotografías o los diagramas. No deje ningún otro orificio abierto en un alojamiento de componentes eléctricos o de cables.

Contenidos del kit adaptador:• Unidad del anillo adaptador

• Unidad del controlador adaptador

• Anillo adaptador de diez pulgadas (254 mm) ABR10 (opcional)

• Bolsa con tornillos de repuesto

• Módulo LED de 8" (203,20 mm) Portfolio (se vende por separado)

• Reflector LED de 8" (203,20 mm) Portfolio (se vende por separado)

Herramientas necesarias (opcionales):• Destornillador Phillips (de otras marcas)

• Destornillador de cabeza plana (de otras marcas)

Unidad del anillo adaptador

Anillo adaptador (opcional)

Bolsa con tornillos de repuesto

Unidad del controlador adaptador

Módulo LED de 8" (203,20 mm) Portfolio (se vende por separado)

Reflector LED de 8" (203,20 mm) Portfolio (se vende por separado)

Page 20: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

20

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

INSTALACIÓN

Unidad del controlador adaptador

Para alojamientos de luminarias fluorescentes compactas horizontalese:

Instalación de esta unidad en el techo1. Extraiga el reflector/la moldura y la lámpara existentes

(Figura 1.).

2. Extraiga los accesorios de montaje del reflector del soporte de montaje (Figura 2.).

3. Ubique la caja de derivación, extraiga la cubierta del balasto/la caja de derivación y desconecte los cables de alimentación (120 o 277). Desconecte las conexiones en el detector de aislamiento, si lo hubiere. Desconecte todos los cables que van desde el portacasquillo hasta el balasto (los colores de los cables pueden variar) (Figura 3.).

4. Extraiga un expulsor de 7/8" de diámetro (conducto de tamaño comercial de 1/2") de la caja de derivación, en la parte superior de ser posible.

5. Coloque la unidad del controlador adaptador a través de la abertura del techo/alojamiento (Figura 4.).

6. Coloque la unidad del controlador adaptador lejos de la abertura del techo/alojamiento y ponga el controlador hacia arriba (Figura 5.).

7. Deje los conductos flexibles de la unidad del controlador adaptador en suspensión hacia afuera de la abertura del techo/alojamiento.

8. Pase los cables de alimentación desde la unidad del controlador adaptador a través del expulsor que se extrajo en la caja de derivación e inserte el conector de colocación a presión en la caja de derivación (Figura 6.).

9. Vuelva a conectar los cables de alimentación en la caja de derivación con los terminales de la unidad del controlador adaptador: el cable negro con el de línea, el blanco con el neutro, el verde con el de conexión a tierra y todo otro cable del regulador, según sea necesario (ver los diagramas de cableado).

10. Vuelva a colocar la cubierta del balasto/la caja de derivación para cerrar por completo la caja de derivación.

Figura 1. Figura 2.

Figura 3. Figura 4.

Figura 5. Figura 6.

Para alojamientos de luminarias fluorescentes compactas verticalese:1. Extraiga el reflector/la moldura y la lámpara existentes

(Figura 7.).

2. Ajuste el soporte del portacasquillo en su posición máxima (Figura 8.).

3. Ubique la caja de derivación, extraiga la cubierta del balasto/la caja de derivación y desconecte los cables de alimentación (120 o 277). Desconecte las conexiones en el detector de aislamiento, si lo hubiere. Desconecte todos los cables que van desde el portacasquillo hasta el balasto (los colores de los cables pueden variar) (Figura 9.).

4. Extraiga un expulsor de 7/8" de diámetro (conducto de tamaño comercial de 1/2") de la caja de derivación, en la parte superior de ser posible.

5. Coloque la unidad del controlador adaptador a través de la abertura del techo/alojamiento (Figura 10.).

Figura 7. Figura 8.

Figura 9. Figura 10.

3

2

1

Page 21: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

21

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

6. Coloque la unidad del controlador adaptador lejos de la abertura del techo/alojamiento y ponga el controlador hacia arriba (Figura 11.).

7. Deje los conductos flexibles de la unidad del controlador adaptador en suspensión hacia afuera de la abertura del techo/alojamiento.

8. Pase los cables de alimentación desde la unidad del controlador adaptador a través del expulsor que se extrajo en la caja de derivación e inserte el conector de colocación a presión en la caja de derivación (Figura 12.).

9. Vuelva a conectar los cables de alimentación en la caja de derivación con los terminales de la unidad del controlador adaptador: el cable negro con el de línea, el blanco con el neutro, el verde con el de conexión a tierra y todo otro cable del regulador, según sea necesario (ver los diagramas de cableado).

10. Vuelva a colocar la cubierta del balasto/la caja de derivación para cerrar por completo la caja de derivación.

Para los alojamientos HIDe:1. Extraiga el reflector/la moldura y la lámpara existentes

(Figura 13.).

2. Ajuste el soporte del portacasquillo en su posición máxima (Figura 14.).

3. Ubique la caja de derivación, extraiga la cubierta del balasto/la caja de derivación y desconecte los cables de alimentación (120 o 277). Desconecte las conexiones en el detector de aislamiento, si lo hubiere. Desconecte todos los cables que van desde el portacasquillo hasta el balasto (los colores de los cables pueden variar) (Figura 15.).

4. Extraiga un expulsor de 7/8" de diámetro (conducto de tamaño comercial de 1/2") de la caja de derivación, en la parte superior de ser posible.

5. Coloque la unidad del controlador adaptador a través de la abertura del techo/alojamiento (Figura 16.).

6. Coloque la unidad del controlador adaptador lejos de la abertura del techo/alojamiento y ponga el controlador hacia arriba (Figura 17.).

7. Deje los conductos flexibles de la unidad del controlador adaptador en suspensión hacia afuera de la abertura del techo/alojamiento.

8. Pase los cables de alimentación desde la unidad del controlador adaptador a través del expulsor que se extrajo en la caja de derivación e inserte el conector de colocación a presión en la caja de derivación (Figura 18.).

9. Vuelva a conectar los cables de alimentación en la caja de derivación con los terminales de la unidad del controlador adaptador: el cable negro con el de línea, el blanco con el neutro, el verde con el de conexión a tierra y todo otro cable del regulador, según sea necesario (ver los diagramas de cableado).

Figura 11. Figura 12.

Figura 13. Figura 14.

Figura 15. Figura 16.

Figura 17. Figura 18.

10. Vuelva a colocar la cubierta del balasto/la caja de derivación para cerrar por completo la caja de derivación.

Para los alojamientos de luminarias incandescentese: 1. Extraiga el reflector/la moldura y la lámpara existentes

(Figura 19.).

2. Ajuste el soporte del portacasquillo en su posición máxima.

3. Ubique la caja de derivación, extraiga la cubierta y desconecte los cables de alimentación (120 o 277). Desconecte las conexiones en el detector de aislamiento, si lo hubiere (Figura 20.).

Figura 19. Figura 20.

Page 22: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

22

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

4. Extraiga un expulsor de 7/8" de diámetro (conducto de tamaño comercial de 1/2") de la caja de derivación, en la parte superior de ser posible.

5. Coloque la unidad del controlador adaptador a través de la abertura del techo/alojamiento (Figura 21.).

6. Coloque la unidad del controlador adaptador lejos de la abertura del techo/alojamiento y ponga el controlador hacia arriba (Figura 22.).

7. Deje los conductos flexibles de la unidad del controlador adaptador en suspensión hacia afuera de la abertura del techo/alojamiento.

8. Pase los cables de alimentación desde la unidad del controlador adaptador a través del expulsor que se extrajo en la caja de derivación e inserte el conector de colocación a presión en la caja de derivación (Figura 23.).

9. Vuelva a conectar los cables de alimentación en la caja de derivación con los terminales de la unidad del controlador adaptador: el cable negro con el de línea, el blanco con el neutro, el verde con el de conexión a tierra (ver los diagramas de cableado).

10. Vuelva a colocar la cubierta del balasto/la caja de derivación para cerrar por completo la caja de derivación.

Instalación de la unidad del anillo adaptador1. Deslice el anillo de banda adaptadora (opcional) por

encima de la unidad del anillo adaptador, mientras sostiene los muelles de montaje en forma vertical (Figura 25.).

2. Sostenga los 2 muelles de montaje en forma vertical, en el mismo lado que la unidad del anillo adaptador; luego, insértelo en la abertura del techo o alojamiento (Figura 26.).

3. Utilice la abertura del techo o alojamiento para mantener los muelles de montaje del Paso 2 en forma vertical y empuje los otros 2 muelles de montaje en posición vertical; luego, inserte el anillo en el techo (Figura 27.).

4. Alinee los receptores del muelle de torsión con los pilotes del alojamiento (si estuvieran colocados) y asegúrese de que los muelles de montaje no toquen ninguna parte del alojamiento para que, de esta forma, las patas de montaje o el anillo de banda adaptadora (si estuviera incluido) queden a ras del techo. Puede ser necesario girar la unidad del anillo adaptador para evitar su obstaculización (Figura 28.).

5. El anillo adaptador puede adaptarse a distintos grosores de techo y alturas del marco de yeso o el alojamiento por medio de las diferentes ubicaciones de las ranuras para los muelles de montaje. La luminaria LD8ART viene con los muelles en la posición superior para obtener un grosor total mayor del techo y el alojamiento en conjunto de 1" (25,40 mm) y no más de 2" (50,80 mm). Para los grosores de techo o alojamiento de entre 0,5" (12,70 mm) y 1" (25,40 mm), los muelles de montaje deben moverse a la posición inferior (Figura 29.).

Figura 21. Figura 22.

Figura 23. Figura 24.

Figura 25. Figura 26.

Figura 27. Figura 28.

Figura 29.

Posición inferior

Posición superior

Page 23: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

23

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

Figura 30.

6. Para evitar que el anillo se mueva en la abertura del alojamiento o techo, utilice un destornillador de cabeza plana para levantar las 4 lengüetas centrantes en la unidad del anillo adaptador (Figura 30.).

Instalación de la moldura1. Extraiga el reflector y el motor de la luminaria LED de

su embalaje protector.

2. Inserte la lente en el reflector blanco (Figura 31.).

3. Inserte el motor de la luminaria LED en la moldura inferior. Alinee las ranuras de la moldura con los orificios para los tornillos del motor (Figura 32.).

4. Usando los tornillos de ajuste manual incluidos, asegure con firmeza la moldura inferior al motor de la luminaria LED (Figura 33.).

5. Conecte el conector (macho) del módulo LED con el conector (hembra) del controlador adaptador; luego, ajuste con firmeza (Figura 34.).

6. Instale el motor de la luminaria LED y la unidad de la moldura, insertando los muelles de torsión en los receptores del muelle ubicados dentro del anillo adaptador (Figura 35.).

7. Presione el módulo LED y la unidad del reflector en la unidad del anillo adaptador hasta que queden a ras del techo (Figura 36.).

8. Vuelva a conectar la alimentación después de finalizar la instalación.

9. Ver ilustración (opción de bañador solamente) (Figura 37.).

Compatibilidad del alojamientoLa altura de instalación mínima requerida es de 8 pulgadas (203,20 mm). Asegúrese de que los cables, el conducto y la copa del portacasquillo queden a un costado, de ser posible.

LD8ART encaja apertura / diafragma mínimo 8,7 po (87 mm) a 10 po (100 mm) máximo (con banda adaptador opcional)• Cooper Lighting: C8X, PD8X, C9X.

Limpieza de las molduras1. Frote suavemente con un trapo suave, limpio, seco y

sin pelusas para quitar el polvo.

2. Frote con una solución de detergente suave en un trapo suave y limpio para quitar las huellas digitales y las manchas.

3. Enjuague con agua limpia y seque con un trapo suave, limpio, seco y sin pelusas.

Figura 31.

Figura 32. Figura 33.

Figura 34.

Figura 35.

Desconexión Powerplug® de la luminaria

Palanca de bloqueo

Gancho

de bloqueo

Figura 36.

Figura 37.

Alinear

RebordePared

Page 24: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

24

Reemplazo del controlador

PRECAUCIÓNPara evitar posibles descargas eléctricas, asegúrese de que la fuente de alimentación se encuentre desconectada antes de instalar esta luminaria o antes de realizarle un servicio de mantenimiento.

• Un electricista cualificado debe reemplazar el controlador.

• El controlador puede reemplazarse desde abajo o por arriba del techo.

1. Extraiga la unidad del módulo de la luminaria LED y la moldura del alojamiento (Figura 38.).

2. Extraiga el controlador y la unidad de la cubierta de la caja de derivación.

3. Desconecte los cables del controlador desenroscando las tuercas para cables.

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

Figura 38.

Cubierta del controlador

Cubierta de la caja de derivación

4. Extraiga el controlador viejo y la unidad de la cubierta de la caja de derivación.

5. Conecte los cables del nuevo controlador con las tuercas para cables.

6. Reajuste el nuevo controlador y la unidad de la cubierta de la caja de derivación.

Diagramas de cableado eléctricoD010TE (consultar disponibilidad en sitio web)

ROJO PARA 277 V NEGRO PARA 120 V

NEGR

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A

TIP

O P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUERCA TIPO P

TUE

RC

A T

IPO

P

NE

GR

C/

NE

GR

C/

RO

JO C

/

RO

JO C

/

BLANC

+

+

-

-

NEGR

NEGR NEGR

NEGR

NEGR

NE

GR

NE

GR

CONDUCTO

CONECTORES

4 4

22

5 5

1 1

CO

NT.

1

LED

1LE

D 2

CO

NT.

2

ROJO

RO

JO

RO

JO

RO

JOR

OJO

ROJO

NEGR

NE

GR

NEGR MARRÓN

BLANC BLANC

BLANC AZUL

BLANCO

GRIS

GRIS GRIS

GRIS GRIS

VIOLETA

VIO

LETA

VIOLETA

VIOLETA VIOLETA

NEGRO PARA 277 V AZUL PARA 120 V

D010 D010TR (consultar disponibilidad en sitio web)

ROJO PARA 277 V NEGRO PARA 120 V

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P TUE

RC

A T

IPO

PTUERCA TIPO P

TUERCA TIPO P

NE

GR

C/

RO

JO C

/

RO

JO C

/

TUE

RC

A

TIP

O P

TUERCA TIPO P

TUE

RC

A TIP

O P

BLANC TUERCA TIPO P

TUERCA TIPO P

+

+

-

-

TUERCA TIPO P

NEGR NEGR

NEGR NEGR

NEGR

CONDUCTO

CONECTORES

NEGR NEGRN

EG

R

ROJO RO

JO

RO

JO

1 1

4 4

22

55

CO

NT.

1

LED

1LE

D 2

CO

NT.

2

ROJO

RO

JO

ROJO

NEGR

NE

GR

NEGR NEGR

BLANC BLANC

BLANC BLANC

BLANCO

GRIS

GRIS GRIS

GRIS GRIS

VIOLETA

VIO

LETA

VIOLETA

VIOLETA VIOLETA

NEGRO PARA 277 V AZUL PARA 120 V

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

DE010 (consultar disponibilidad en sitio web) (opción 1)

NEGR

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A

TIP

O P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

NE

GR

C/

NE

GR

C/

ROJO C/

ROJO C/

BLANC

+

+

-

-

NEGR

NEGR MARRÓN

NEGR

NE

GR NE

GR

CONDUCTO

CONECTORES

4 4

22

5 5

1 1

CO

NT.

1

LED

1LE

D 2

CO

NT.

2

RO

JO

RO

JO RO

JO

RO

JO

ROJO

NEGR

NEGR

NEGR MARRÓN

BLANC AZUL

BLANC AZUL

BLANCO

GRIS

GRIS

GRIS

VERD

VERD

VERD

VERD

AIN-(0-10V)

AIN- (0-10 V)

VIOLETA

CONEX A TIERRA/PELADO

VIOLETA

VIOLETA AIN+(0-10V)

AIN+(0-10V)

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

DE010 (consultar disponibilidad en sitio web) (opción 2)

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUE

RC

A

TIP

O P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P

TUE

RC

A

TIP

O P

NE

GR

NE

GR

C/

NE

GR

C/

ROJO C/

RO

JO C

/

TUE

RC

A

TIP

O P

TUE

RC

A

TIP

O P

BLANCTUERCA TIPO P

TUERCA TIPO P

+

+

-

-

TUERCA TIPO P

NEGR NEGR

NEGR NEGR

AZULCONDUCTO

CONECTORES

NEGR NEGR

ROJO

RO

JO

RO

JO

RO

JO

1 1

4 4

22

5 5

CO

NT.

1

LED

1LE

D 2

CO

NT.

2

ROJOR

OJO

ROJO

NEGR

NE

GR

NE

GR

NEGR NEGR

BLANC BLANC

BLANC BLANC

VERD

VERD

BLANCO

GRIS

GRIS GRIS

GRIS GRIS

VIOLETA

VIOLETA VIOLETA

VIOLETA VIOLETA

A TIERRA

Page 25: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

25

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

D5LT (consultar disponibilidad en el sitio web)

NEGR

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

NE

GR

C/

NE

GR

C/

ROJO C/

RO

JO C

/

BLANC

+

+

-

-

NEGR

NEGR

NE

GR

NE

GR

CONDUCTO

CONECTORES

4 4

22

5 5

1 1

CO

NT.

1

LED 1

LED 2

CO

NT.

2

RO

JO

RO

JO

RO

JO

RO

JO

ROJO

NEGR

NE

GR

NEGR

NEGR

MARRÓN

MARRÓN

BLANC

BLANC

AZUL

AZUL

BLANCO

CONEX A TIERRA/PELADO

VERD

VERD

VERD

VERD

DA-

DA-

VIOLETA

VIOLETA/BLANC

VIOLETA/BLANC

VIOLETA/BLANC

VIOLETA

VIOLETA

DA+

DA+

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

DMX (consultar disponibilidad en sitio web)

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

P TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

P

NE

GR

C/

ROJO C/

NE

GR

C/

RO

JO C

/

BLANCTUERCA TIPO P

TUERCA TIPO P

+

+

-

-

TUERCA TIPO P

NEGR NEGR

CONDUCTO

CONECTORES

NEGR

RO

JO

11

4 4

22

5 5

CO

NT.

1

LED

1LE

D 2

CO

NT.

2

RO

JO

ROJO

NEGR

NE

GR

NEGR

NEGR

MARRÓN

MARRÓN

DMX EN +

DMX EN +

DMX EN -

DMX EN -

DMX EN PANTALLA CONDUCTORA

DMX EN PANTALLA CONDUCTORA

BLANC

BLANC

AZUL

AZUL

BLANCO

MARRÓN

NARANJA/BLANCO

NA

RA

NJA

/B

LAN

CO

VERD

VERD

VERD

VERD

NARANJA

NARANJA/BLANCO

CONEX A TIERRA/PELADO

NARAN

NARAN

MARR/C

MA

RR

/C

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

DL3 (consultar disponibilidad en sitio web)

NEGR

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

NE

GR

C/

RO

JO C

/

BLANC

+

+

-

-

NEGR

NEGR NEGR

NEGR

NEGR

NE

GR

NE

GR

CONDUCTO

CONECTORES

4 4

22

5 5

1 1

CO

NT.

1

LED

1LE

D 2

CO

NT.

2

ROJO C/

ROJO

RO

JO

RO

JOROJO

NEGR

NE

GR

NEGR

NARAN

NARAN

NARANJA

NARANJA

BLANCO

VERD

VERD

VERD

VERDVIOLETA

VIOLETA/BLANC

CONEX A TIERRA/PELADO

NARANJA

BLANC

BLANC

BLANC

BLANC

VIO/BLANC

VIO/BLANC

VIO

VIOLETA

VIOLETA

VIOLETA

VIOLETA

VIOLETA

D010TEEMBOD (consultar disponibilidad en el sitio web)

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO 120 V NARAN-277 V

1T5

VIVO NO CONMUTADO

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

NE

GR

C/

NEGR C/

ROJO C/

ROJO C/TUERCA TIPO P

TUE

RC

A

TIPO

P

TUE

RC

A

TIPO

P

BLANC

TUE

RC

A

TIP

O PTU

ER

CA

TIP

O P

+

+

+

+

-

-

-

-

TODOS

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 2

CONTROLADOR LED DE EMERGENCIA

CONECTORES

NEGR

NE

GR

RO

JO

RO

JO

11

4 4

2 2

55

CO

NT.

1

LED 1

LED 2

CO

NT.

2

RO

JO

NEGR

NEGR

NE

GR

BLANC

BLANC

BLANCO

INTERR VIVO

GRIS

GRIS

GRIS GRIS

GRIS

VIOLETA

VIOLETA

VIOLETA VIOLETA

VIOLETA

MARRÓN

MARRÓN

MA

RR

ÓN

VIO

LETA

BLA

NC

O

BLANCO

BLA

NC

/RO

JO

RO

JO

BLANC/NEGR

NARAN/NEGR

NARAN/NEGR

AM

AR

ILLO

AM

AR

/NE

GRAZUL

BLANCO

AZUL

NEGRO PARA 277 V AZUL PARA 120 V

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO 120 V NARAN-277 V

1T5

VIVO NO CONMUTADO

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

PTUERCA TIPO P NE

GR

C/

NE

GR

C/

ROJO C/

ROJO C/TUERCA TIPO P

TUERCA TIPO P

BLANC

TUE

RC

A TIP

O P

TUE

RC

A

TIPO

P

+

+

+

+

-

-

-

-

TODOS

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 2

CONTROLADOR LED DE EMERGENCIA

CONECTORES

NEGR

NE

GR

RO

JOR

OJO

11

4 4

2 2

55

CO

NT.

1

LED 1

LED 2

CO

NT.

2

RO

JO

NEGR

NEGR NEGR

NE

GR

NEGR

BLANC BLANC

BLANC

BLANCO

INTERR VIVO

GRIS

GRIS

GRIS GRIS

GRIS

VIOLETA

VIOLETA

VIOLETA VIOLETA

VIOLETA

MA

RR

ÓN

VIO

LETA

BLA

NC

O

BLA

NC

O

BLA

NC

/RO

JO

RO

JO

BLANC/NEGR

NARAN/NEGR

NARAN/NEGR

AM

AR

ILLO

AM

AR

/NE

GR

AZU

L

BLANCONEGRO PARA 277 V AZUL PARA 120 V

D010TREMBOD (consultar disponibilidad en sitio web)

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO 120 V NARAN-277 V

1T5

VIVO NO CONMUTADO

TUERCA TIPO P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUERCA TIPO P

NE

GR

C/

NE

GR

C/

RO

JO C

/

ROJO C/

ROJO C/

TUE

RC

A T

IPO

P

TUERCA TIPO P

BLANC

TUE

RC

A

TIP

O P

TUERCA TIPO P

+

+

+

+

-

-

-

-

TODOS

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 2

CONTROLADOR LED DE EMERGENCIA

CONECTORES

NEGR

RO

JO

11

4 4

2 2

55

CO

NT.

1

LED 1

LED 2

CO

NT.

2

RO

JO

NEGR

NEGR

NEGR

BLANC

BLANCO

VERDE

INTERR VIVO

GRIS

GRIS

GRIS

VIOLETA

VIOLETA

VIOLETA

MA

RR

ÓN

VIO

LETA

BLA

NC

O

BLA

NC

O

BLA

NC

/RO

JO

RO

JO

BLANC/NEGR

NARAN/NEGR

NARAN/NEGR

AM

AR

ILLO

AM

AR

/NE

GRAZUL

BLANCO

NEGRO PARA 277 V AZUL PARA 120 V

DE010EMBOD (consultar disponibilidad en el sitio web) (opción 1)

VERD

VERD VERD

VERD

0-10-

0-10-

0-10+

0-10+

MA

RR

ÓN

MARRÓN

AZUL

AZUL

Page 26: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

26

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

ROJO PARA 277 V NEGRO PARA 120 V

ROJO PARA 277 V NEGRO PARA 120 V

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO 120 V NARAN-277 V

NEGRO 120 V NARAN-277 V

NEGRO 120 V NARAN-277 V

1T51T5

1T5

VIVO NO CONMUTADO

VIVO NO CONMUTADO

VIVO NO CONMUTADO

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUERCA TIPO P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUERCA TIPO P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

P

NE

GR

C/

NE

GR

C/

NE

GR

C/

NE

GR

C/

NE

GR

C/

NE

GR

C/

RO

JO C

/

RO

JO C

/

RO

JO C

/

ROJO C/

ROJO C/

ROJO C/

TUE

RC

A TIP

O P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

BLANC

BLANC

BLANC

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

TUERCA TIPO P

+

+

+

+

+

+

+

+

+

+

+

+

-

-

-

-

-

-

-

-

-

-

-

-

TODOS

TODOS

TODOS

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 2

CONDUCTO FLEXIBLE 2

CONDUCTO FLEXIBLE 2

CONTROLADOR LED DE EMERGENCIA

CONTROLADOR LED DE EMERGENCIA

CONTROLADOR LED DE EMERGENCIA

CONECTORES

CONECTORES

CONECTORES

NEGR

NEGR

NEGR

NEGR

RO

JO

RO

JO

RO

JO

ROJO

1

1

1

1

1

1

4

4

4

4

4

4

2

2

2

2

2

2

5

5

5

5

5

5

CO

NT.

1

CO

NT.

1

CO

NT.

1

LED 1

LED 1

LED 1

LED 2

LED 2

LED 2

CO

NT.

2

CO

NT.

2

CO

NT.

2

RO

JO

RO

JO

RO

JO

NEGR

NEGR

NEGR

NEGR

NEGR

NEGR

NE

GR

NEGR

NEGR

NEGR

MARRÓN

MARRÓN

BLANC

BLANC

BLANC

BLANC

AZUL

AZUL

BLANCO

BLANCO

BLANCO

VERDE

VERDE

INTERR VIVO

INTERR VIVO

INTERR VIVO

GRIS

GRIS

GRIS

GRIS

DA-

DA-

GRIS GRIS

VIOLETA

VIOLETA/BLANC

NARANJA/BLANCO

NARANJA

VIOLETA

MARRÓN/BLANC

VIOLETA

VIOLETA

VIOLETA

DA+

DA+

VIOLETA

VIOLETA/BLANC

VIOLETA

VIOLETA

MA

RR

ÓN

MA

RR

ÓN

MA

RR

ÓN

VIO

LETA VIO

LETA

VIO

LETA

BLA

NC

O

BLA

NC

O

BLA

NC

O

BLA

NC

O

BLA

NC

O

BLA

NC

O

BLA

NC

/RO

JO

BLA

NC

/RO

JO

BLA

NC

/RO

JOR

OJO

RO

JO

RO

JO

BLANC/NEGR

BLANC/NEGR

BLANC/NEGR

NA

RA

N/N

EG

R

NARAN/NEGR

NARAN/NEGR

NARAN/NEGR

NARAN/NEGR

NARAN/NEGR

AM

AR

ILLO

AM

AR

ILLO

AM

AR

ILLO

AM

AR

/NE

GR AM

AR

/NE

GR

AM

AR

/NE

GR

AZUL

AZUL

AZU

L

BLANCO

BLANCO

BLANCO

BLANCO

AZUL

AZUL

NEGRO PARA 277 V AZUL PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

NEGRO PARA 277 V AZUL PARA 120 V

VERD

VERDE

VERDE

VERD

VERD

VERD

VERD

VERD

VERD

VERD

AZUL

MARRÓN

MARRÓN

DE010EMBOD (consultar disponibilidad en el sitio web) (opción 2)

A TIERRA

D05LTEMBOD (Consultar su disponibilidad en el sitio web)

DMXEMBOD (consultar disponibilidad en el sitio web)

MARRÓN/BLANC

MARRÓN/BLANC

DMX EN PANTALLA CONDUCTORA

DMX EN PANTALLA CONDUCTORA

DMX IN+

DMX IN+

DMX IN-

DMX IN-

NARANJA/BLANCO

NARANJA/BLANCO

NARANJA

NARANJA

Page 27: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

27

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART

Instrucciones de instalación del adaptador para luminarias LED empotradas y de uso comercial LD8ART 706240INS ADP140604 www.eaton.com

ROJO PARA 277 V NEGRO PARA 120 V

NEGRO 120 V NARAN-277 V

1T5

VIVO NO CONMUTADO

TUERCA TIPO P

TUERCA TIPO P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

PTU

ER

CA

TIP

O P

TUE

RC

A T

IPO

P

TUE

RC

A T

IPO

P

NE

GR

C/N

EG

R C

/ ROJO C/

ROJO C/

TUERCA TIPO P

TUE

RC

A

TIPO

P

BLANC

TUERCA TIPO P

TUERCA TIPO P

+

+

+

+

-

-

-

-

TODOS

CONDUCTO FLEXIBLE

CONDUCTO FLEXIBLE 1

CONDUCTO FLEXIBLE 2

CONTROLADOR LED DE EMERGENCIA

CONECTORES

NEGR

RO

JO

11

4 4

2 2

55

CO

NT.

1

LED 1

LED 2

CO

NT.

2

RO

JO

NEGR

BLANCO

VERDE

INTERR VIVO

VIOLETA/BLANC

NARANJA

VIOLETA

MA

RR

ÓN

VIO

LETA

BLA

NC

O

BLA

NC

O

BLA

NC

/RO

JO

RO

JO

BLANC/NEGR

NARAN/NEGR

NARAN/NEGR

AM

AR

ILLO

AM

AR

/NE

GR

AZU

L

NEGRO PARA 277 V AZUL PARA 120 V

DL3EMBOD (consultar disponibilidad en el sitio web)

NEGR

NEGR

NEGR

NEGR

NARANJA

NARANJA

BLANC

BLANC

BLANC

BLANC

VERD

VERD

VERD

VERD

VIOLETA

VIOLETA

VI0

VI0

VI0

VI0

VIOLETA/BLANC

VIOLETA/BLANC

RegulaciónLas luminarias de la serie Portfolio LD8*DO1OTE/D010TR pueden regularse con muchos controladores electrónicos de voltaje bajo, estándares e incandescentes, de 120 V. Las luminarias de la serie Portfolio LD8*DL3 pueden regularse con controles de regulación fluorescentes Lutron de 3 hilos. Las luminarias de la serie Portfolio LD8*D010/DE010/D010TE/D010TR pueden regularse con controles de regulación de 0-10 VCC. Las luminarias de la serie Portfolio LD4*D010/LD6*D010 NO pueden regularse con reguladores de voltaje de línea. Para asegurarse de que cuenta con información actualizada sobre la compatibilidad entre luminarias y reguladores, remítase al sitio web de las luminarias LED Portfolio: www.portfolio-lighting.com

Page 28: Portfolio LD8ART Commercial Recessed LED Retrofit · LD8ART Commercial Recessed LED Retrofit LD8ART Commercial Recessed LED Retrofit 706240INS ADP140604 INSTALLATION Retrofit Driver

Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com

Eaton’s Cooper Lighting Business1121 Highway 74 SouthPeachtree City, GA 30269Cooperlighting.com

© 2014 EatonAll Rights ReservedPrinted in USAImprimé aux États-UnisImpreso en los EE. UU.Publication No. ADP140604

Eaton is a registered trademark.All trademarks are property of their respective owners.

Eaton est une marque de commercedéposée. Toutes les autres marques de commerce sont la propriété de leur propriétaire respectif.

Eaton es una marca comercialregistrada. Todas las marcas comerciales son propiedad de sus respectivos propietarios.

Warranties and Limitation of LiabilityPlease refer to www.cooperlighting.com/WarrantyTerms for our terms and conditions.

Garanties et limitation de responsabilitéVeuillez consulter le site www.cooperlighting.com/WarrantyTerms pour obtenir les conditions générales.

Garantías y Limitación de ResponsabilidadVisite www.cooperlighting.com/WarrantyTerms para conocer nuestros términos y condiciones.