Page 1: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

A8032G

04/16

Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

PASSPORT 1000Mortise LockInstallation Instructions

P1

Page 2: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock
Page 3: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Warning 1

1

2

3

4

5

6

7

Table of ContentsWarning ...................................................................................3General Description .................................................................4Hardware Specifications .........................................................4Electronic Specifications .........................................................4Installation Wiring ...................................................................5Parts Breakdown .....................................................................9Installation Instructions ........................................................10Operational Check ................................................................218

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

!

Industry Canada: This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain ap-proved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélec-trique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manu-facturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:

• Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches and mounting plates especially when mounting electronic components such as readers and controllers onto the door

• Leave components (reader and controller) protected in their respective anti-static bags until ready for installation.

• Do not touch pins, leads or solder connections on the circuit boards.

Page 4: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

4 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

General Description2

Hardware Specifications3• ANSI/BHMA A156.25 Listed Grade 1 Compliant

• Outside lever is unlocked through access control credentials only

• Outside lever controlled by any combination of keypad, magnetic swipe, contactless reader or mechanical cylinder

• May be used for indoor and outdoor applications

• Complete locksets with controller

• ADA Compliant

• Easily retrofits existing Passport 1000 door preps (mortise locks)

• Latch 1/2" standard 3/4" throw fire-rated double doors (optional) (41- prefix)

• Deadlocking latch

• Inside lever retracts latch

Electronic Specifications4• 2,400 users per lock; 10,000 event audit trail

• Multiple time zone and holiday access scheduling

• First-In unlock configuration, based on specified time schedule

• Uses existing Magstripe keycards (track 2)

• Magnetic Stripe Card Coercivity: HiCo (4000 Oersted) or LoCo (300 Oersted)

• HID® multiCLASS SE® technology offers support for the following credentials:• 2.4 GHz credential compatibility:

• Secure Identity Object™ (SIO) on Mobile IDs (Bluetooth Smart)

• 125 kHz credential compatibilty:

• HID Prox®

• 13.56 MHz credential compatibility:

• iCLASS®

• iCLASS SE® (SIO-enabled)

• iCLASS Seos®

• SIO on MIFARE® Classic

• SIO on MIFARE® DESfire® EV1

• MIFARE® Classic

• DESfire® EV1• NFC-enabled mobile phones

• Magnetic Stripe

*UL testing was conducted on product powered by UL Listed model 9001GR/AC injector; manufactured by Microsemi Corp.

Destructive Attack Level 1

Line Security Level 1

Endurance Level 4

Standby Power Level 1

• UL Listed* - UL 294 Indoor Use

• CUL Listed - S319: Class 1

• UL 294 Access Control Ratings:

• Power Requirements: 55VDC, 90mA

• PoE Class 1 Device, as defined by IEEE 802.3af, requires less than 3.84 watts over structured cabling

An ANSI/BHMA Grade 1 lock utilizing Power over Ethernet (PoE) technology, the Passport 1000 P1 provides a cost-effective, future-proof solution for campuses. Featuring multiCLASS SE® Technology from HID Global®, it provides simultaneous support for multiple credentials and offers an easy migration path to higher security credentials and mobile access. Recognized for its contribution to sustainable buildings, the P1 re-uses existing IEEE 802.3af PoE infrastructure, streamlines the installation process, reduces costs and components, and minimizes power consumption.

NOTE: A weather-protective gasket is required for outdoor applications.

Page 5: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 5

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

Installation Wiring5

SARGENT Passport Series PoE P1 Typical Application

LMT: Lock Management Tool

A. PoE frame harness assemblyB. PoE data hinge from McKinney (patent pending)C. PoE door harness* from McKinneyD. Passport Series v.P1 PoE Lock

* Door width determines length

Network Cable

Network Switch (802.3af)Surface Mount RJ45

A

B C

D

Supplied by Others

Overview

Page 6: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

6 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

Molex-F Molex-F Molex-M

Cable: CAT 5e,26 AWG stranded,

100ohm

RJ45-M

Molex-M

Cabl

e: C

AT 5

e or

hig

her

24 A

WG

100

ohm

B-Splice Crimp Connector

PoE Lock

Ceiling

Supplied by CI

GroundRing Terminal

Secured to Lock Mounting Plate

Frame-SideHarness

Assembly(15' length)

Patch PanelCable: CAT 5e or higher24 AWG

RJ45-F Jack

Approved Software

Certified Integrator (CI) supplies and terminates the B-Splice connector and the

male RJ45 connector from harness to end user provided facility cable

Supplied by End User

PoE Switch

PoE Switch isTerminated toEarth Ground

Patch Cable Patch Panel to

PoE Switch

Wiring to TIA/568-B Standard

A

Notes:

• Connectors go on only one way. They cannot be placed in an incorrect position.

• Do not force and do not offset connectors

• Be sure they are completely seated (flush)

• PoE power source cannot be connected to a receptacle controlled by a switch

B

C

D

Installation Wiring (Continued)

To building or electrical ground

RJ45-M

Page 7: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 7

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

Installation Wiring (Continued)

Components and wire harness supplied by McKinney. Suggested installation:

RJ45-M

Molex-M

Cab

le: C

AT 5

e or

hig

her

24 A

WG

100

ohm

B-Splice Crimp Connector

Ceiling

Supplied by CI

Cut end / ceiling-side PoE harness:

TIA/EIA 568-B Standard Wiring

1 2 3 4 5 6 7 8

Do not confuse pair numbers with pin numbers. A pair number is used for reference only (eg: 10BaseT Ethernet uses pairs 2 & 3). The pin numbers indicate actual physical locations on the plug and jack.

Frame-SideHarness

Assembly(15' length)

24AWG Stranded

Drain Wire for

Earth Ground in 15' Frame

Harness

Cable drain wire

concealed in shrink tubing

Frame Harness Installation

Hinge side of PoE harness:

A

1. Feed cut end of harness into hole on hinge-side through single access hole.

2. Push one connector back through the hole and feed into the other access hole.Each of the hinge-side harness connectors should end up threaded through a different access hole and matched to the same size pin connector from the door harness:

• 4-pin male molex connector

• 6-pin male molex connector with ground wire

PIN Wire Pair Number

1 White/Orange 2

2 Orange 2

3 White/Green 3

4 Blue 1

5 White/Blue 1

6 Green 3

7 White/Brown 4

8 Brown 4

1 8pin 8 1pin

4-pin M

6-pin M

FramePoE Hinge

PoE Data Hinge

Hinge-side harness connectors:

• 4-pin female molex connector

• 6-pin female molex connector with ground wire

Lock-side harness connectors:

• 4-pin female molex connector

• 6-pin female molex connector with ground wire

B

4-pin F

6-pin F

4-pin F

6-pin F

Page 8: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

8 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

Order of installation may vary. Refer to appropriate sections for instructions.

1. Prop door open.

2. Using the ring terminal, carefully route the assembly through the door channel to the lock.

PoE Door Harness

PoE Lock

4-pin F 4-pin M4-pin F

6-pin F 6-pin F 6-pin M

Cable: CAT 5e,26 AWG stranded,

100ohm

PoE Lock

C

Inside of Door

RJ45-M

D

PoE Harness (Cat 5e)

Order of installation may vary. Refer to appropriate sections for instructions.

Hinge-side harness connectors:

• 4-pin male Molex connector

• 6-pin male Molex connector with ground wire

Lock-side harness connectors:

• Ring terminal

• Male RJ45 connector (crimped after cable is fed through door)

Notes:

• Connectors go on only one way. They cannot be plugged to incorrect position.

• Do not force and do not offset connectors.

• Be sure they are completely seated (flush).

Page 9: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 9

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

Parts Breakdown6

P1 PoE Lock with Magnetic Card Swipe With or Without Keypad

4

5

ITEM No. PART No. DESCRIPTION

1 52-3583-[finish] Outside Escutcheon Assembly, mag stripe

52-3582-[finish] Outside Escutcheon Assembly, mag stripe and Keypad (shown)

52-4244-[finish] Outside Escutcheon Assembly, Mag Swipe, Keypad, and HID 125 kHz Prox

52-4759-[finish] Outside Escutcheon Assembly, iCLASS, keypad, mag stripe, Prox, smart card (MIFARE, DESFIRE)

52-4777-[finish] Outside Escutcheon Assembly, iCLASS, mag stripe, Prox, smart card (MIFARE, DESFIRE)

52-4787-[finish] Outside Escutcheon Assembly, FeliCa, keypad, mag stripe, Prox

52-4788-[finish] Outside Escutcheon Assembly, FeliCa, mag stripe, Prox

52-4894-[finish]* Outside Escutcheon Assembly, Standard Reader and Keypad

52-4895-[finish]* Outside Escutcheon Assembly, Standard Reader

52-4896-[finish]* Outside Escutcheon Assembly, Felica Reader and Keypad

52-4897-[finish]* Outside Escutcheon Assembly, Felica Reader

2 52-4779 Mounting Plate Assembly

3 52-4940 PoE Controller Assembly

4 52-4776-[finish] Inside Escutcheon Assembly with Privacy Button

5 52-5373 Door Position Switch Kit

*Bluetooth® Smart option

1 2

3

Page 10: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

10 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

ITEM PART No. DESCRIPTION

1 See catalog #41 Cylinder (1-1/8" Minimum Length)

2 Consult Factory Cylinder Rosette

3 P1-82276-[finish]* Lock body with deadbolt & with cylinder

P1-82277-[finish]* Lock body with deadbolt without cylinder

P1-82278-[finish]* Lock body without deadbolt with cylinder

P1-82279-[finish]* Lock body without deadbolt without cylinder

4 77-2592 130 KB Thumb turn for Deadbolt Functions Only

5 See catalog Inside Lever Handle

6 See catalog Outside Lever Assembly

7 82-3211 Trim Pack - 8200 Standard Levers (shown)

82-5357 Trim Pack - 8200 Deco Levers & 7900 all lever styles

8 See catalog Mortise Rose

9 82-0347 Spindle Spring

10 Consult factory Mortise screw pack - specify finish (includes: wood and metal lock body screws, faceplate screws, and strike screws)

11 82-0578 Outside Front Plate (Electrical, Latchbolt & Guardbolt)

82-0579 Outside Front Plate (Electrical, Deadbolt, Latchbolt and Guardbolt)

4

5

6

77

78

89

1010 11 10

Parts Breakdown (Continued)

3*

Tools Required:• #2 Phillips screwdriver

• Flat head

• T20 Torx® driver

• Security allen wrench

*Bluetooth® Smart option

Page 11: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 11

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

1 Door Preparation

Installation Instructions7

Left HandHinges Left.

Open Inward.“LH”

Left HandReverse BevelHinges Left.

Open Outward“LHRB”

Right HandHinges Right.Open Inward.

“RH”

Right HandReverse BevelHinges Right.

Open Outward.“RHRB”

A. Verify Hand and Bevel of Door

C. Door Preparation

• Field prep template: A8064 for wood and metal doors

• Door manufacturers template: 4651

Outside of Door Inside of Door

Through Bolt Holes

Inside Mounting Plate Mounting Holes

Controller Cutout

Thumb Turn Location(Deadbolt Functions Only)

Lever Handle Holes

Through Bolt Holes

Controller Cutout

Cylinder Hole

Lever Handle Holes

Mortise Pocket

Raceway for PoE Raceway for PoE

B. Verify Product Label

Page 12: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

12 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

2 Prepare Lock Body

Red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A):

a. Position lock body with red surface of locking piece visible.

b. Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body.

c. Rotate the locking piece 180° until RED surface is on opposite side.

Note: Red indicates locked side (outside).

Beveled surface of latch must face strike (Fig. 2B).

The deadlatch is self adjusting.

To change hand of latchbolt:

a. Insert screwdriver into spade (triangular)- shaped slot.

b. Rotate screwdriver 90º to push latch out until back of latch clears lock front; then rotate latch 180º.

Latch will then re-enter lock body.

Note: Latch cannot be unscrewed.

Fig. 2A

Locking Guide Slot:Red color indicates

locked side.

Push In

Right HandLock Shown

1. Reverse Lock Hand

2. Reverse Latch Hand

Triangular Slot

Latchbolt

Fig. 2B

Page 13: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 13

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

3 Install Lock Body

1. Feed the wire harness into the mortise pocket and through inside preparation hole as depicted in Figure 3.

2. Carefully push the lock body into the pocket while lightly applying tension to the wire harness.

Fig. 3

(2) #12-24 screws

Inside of Door

Wire Harness

Note: Do not pull the lock into the pocket using the harness alone.

Ensure that the wire harness is not pinched between the lock and the mortise pocket.

3. Insert (2) #12-24 screws into the lock body (Fig.4) and partially tighten* with a screw driver.

*Do not fully tighten until cylinder and levers are installed and properly aligned.

Ground Wire

Cat 5e cable from hinge

Page 14: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

14 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

Fig. 4B Fig. 4C

Outside of Door

4 Outside Cylinder Installation

Rosette

Spring

Cylinder

IMPORTANT: Position cylinder so that the SARGENT logo is positioned correctly.

Correct Incorrect

Fig. 4A

1. Slide the spring and the rosette onto the cylinder.

2. Rotate the cylinder into cylinder hole with fingers.

3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole. Note: Do not attempt to tighten all the way.

4. Verify that orientation of cylinder has the SARGENT logo as depicted in Fig. 4A.

5. Hand tighten the cylinder clamp screw with Phillips screwdriver to prevent unscrewing of the cylinder (Fig 4C).

6. Test cylinder function:

• Key retracts latchbolt and deadbolt (7976 function)

• Key retracts latchbolt (7978 function)

• Cylinder not present for 7977 and 7979 functions

Cylinder Clamp Screw

Phillips Screwdriver

Page 15: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 15

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

Inside of DoorOutside of Door

Fig. 5BFig. 5A

5 Assemble Outside Trim

1. With outside lever horizontal, insert the mounting posts through outside of door and lock body.

Make certain the lever spindle is properly engaged inside the lock body (Fig 5A).

2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 5B).

3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8" Phillips oval head and lock washer machine screws.

Note: Ensure that position of set screw hole on inside adapter is oriented to match location of hole in inside lever handle.

Wire Harness(From Lock Body)

Spindle

Outside Trim

Spindle

Fig. 5A Detail

Outside Trim

Set Screw Hole

Ground Wire

Page 16: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

16 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

1. Place inside rose flush against door surface and rotate first counter-clockwise to seat the threads, then clockwise to securely tighten.

2. Slide lever onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of the door. Push lever onto spindle so minimum gap is visible.

3. Tighten the set screw securely with a T20 Torx® driver.

4. Finish securely tightening (2) #12-24 lock body screws.

5. Before closing the door, test that the lever is functional and ensure smooth operation of the latchbolt.

6 Install Inside Rose and Inside Lever Assembly

Fig. 6Set Screw

Inside Lever

SpindleRose

Inside of Door

#12-24 screws

7 Install Thumb Turn

1. Insert thumb turn into preparation hole and engage slot in lock body.

2. Orient mounting plate so screw hole is vertical (aligned with preparation holes).

3. Secure plate with Phillips screw provided (Fig. 7).

4. Test thumb turn for function by retracting and projecting the deadbolt (7976 and 7977 functions only).

Thumb Turn Assembly

Inside of Door

Phillips screw

Fig. 7

Page 17: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 17

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

8 Install Gasket (Optional) and Outside Escutcheon

Note: Gasket is optional, for non-fire rated doors only.

For non-fire rated door applications, a gasket (Part number 52-0782) may be used as a weather seal between the escutcheon and the outside door surface.

1. Peel off adhesive backing and attach to outside escutcheon.

2. Insert the mounting posts through holes as shown.

3. Feed reader cable through side opening (Fig. 8).

Fig. 8

EscutcheonGasket

Outside of Door

9 Mounting Plate Assembly

Fig. 9

Ground Lugs

1. On the inside of the door, position the mount-ing plate over the indicated holes.

2. Feed reader cable and ground ring terminal through central opening on mounting plate (Fig. 9).

3. Route PoE Harness through alternate open-ing (to the right of the central opening).

4. Route ground ring terminal from lock body through bottom of mounting plate and attach to bottom right corner using (1) #8-32 x 1-7/8” flat head machine screw.

5. Insert other three #8-32 x 1-7/8” flat head machine screws and tighten, fastening the outside escutcheon to the door (Fig. 9).IMPORTANT: If the following step is skipped, the product will not be UL-compliant:

6. Attach two (2) #8 x 3/8” flat head wood screws for wood doors or (2) #8-32 x 3/8” flat head machine screws for metal doors (Fig. 9).

PoE Harness

Page 18: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

18 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

1. Tuck excess cable into wire hole on inside of door.

2. Secure the mounting assembly while ensuring proper alignment of outside reader and fully tighten the (2) through- bolts on the inside of the door to secure the reader and plate to the door.

Secure the following connectors to their respective terminals (Fig. 10A):

A. Secure the 10-pin lock body assembly connector.

CAUTION - Do not touch or allow debris to enter connector contacts.

Secure Mounting Plate

B. Secure the 24-pin card reader connector (Fig. 10A).

C. Crimp* RJ45 to Cat 5e cable from hinge (Fig. 10B).

*For more detail, refer to section (5) ‘Installation Wiring’, “A - Frame Harness Installation”.

TIA/EIA 568-B Standard Wiring

1 2 3 4 5 6 7 8

Do not confuse pair numbers with pin numbers. A pair number is used for reference only (e.g.: 10BaseT Ethernet uses pairs 2 & 3). The pin numbers indicate actual physical locations on the plug and jack.

PIN Wire Pair Number

1 White/Orange 2

2 Orange 2

3 White/Green 3

4 Blue 1

5 White/Blue 1

6 Green 3

7 White/Brown 4

8 Brown 4

Fig. 10B

1 8pin 8 1pin

10 Installation of Connectors

Crimp* to RJ45-M Connector

Cat 5e cable from hinge

RJ45-M

C

Ground Lugs

Lock Body (10-pin)

Reader (24-pin)

Board-to-Board Connector

Fig. 10A

B

A

IMPORTANT: Do not run wires through bottom hole in plate (Fig. 10A) - it will damage wires and controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 10A).

Page 19: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 19

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

11 Install Inside Module Component Assembly

Fig. 11A

1. Insert top tabs of controller into slots on mounting plate (Fig. 11A).

2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate.

CAUTION: To avoid possible damage to board-to-board connec-tors, care should be taken when securing controller to mounting plate. If there is resistance when securing, detach controller to de-termine cause before re-attaching controller.

Fig. 11B

Fig. 11C

3. Connect RJ45 male Connector to female RJ45 on controller board (Fig. 11B, C).

4. Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab (Fig. 11B, C).

Coin Cell Pull Tab

Page 20: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

20 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

12 Install Inside Escutcheon

1. Position inside escutcheon as shown (Fig. 12).

Verify that all wires are positioned within the es-cutcheon to avoid pinching.

2. Attach escutcheon with (2) #8-32 x 1/2” T-20 Torx pan head screws.

3. Straighten escutcheon and tighten securely.

DO NOT OVERTIGHTEN.

Fig. 12

Attach front plate with (2) #8-32 X 1/4” flat head screws (Fig. 13).

13 Attach Outside Front Plate

Inside of Door

Inside of Door

(2) #8-32 x 1/2” Torx Screws

(2) #8-32 x 1/4” Flat Head Screws

Fig. 13

Page 21: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

04/3

0/16

1-800-810-WIRE • www.sargentlock.com • A8032G 21

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

Passport 1000 P1 PoE Mortise Lock

Operational Check8IMPORTANT: Be sure to test functions prior to closing door.In all cases, perform the following checks:1. Ensure that inside lever retracts latch.

• For units with cylinders, the following checks apply:Insert key into cylinder and rotate:a. There should be no friction against lock case or any other

obstructions. If friction or binding occurs, re-adjust cylinder to eliminate issues.

b. The key should retract the latch and the key should rotate freely.c. The key should extend and retract the deadbolt.

• For units without a keypad, add card using LCT software* and test. • For units with a keypad, add pin and card using LCT software* and test.

2. LED signaling:• After using a valid credential, a green flash followed by three fast

amber flashes indicates a low power condition. • Check the input voltage. • If the input voltage is low, disconnect the lock from the power source

and check the power source voltage. If the power source voltage is correct, inspect the lock wiring for a possible short.

If the lock loses power, it will flash rapid blue for approximately one minute. Lock will default to programmed fail safe or fail secure.

After that, the lock will no longer be functional.3. When you have completed the tests, close the door, ensuring latchbolt fully

extends into strike plate without binding.

*Refer to Network and Lock Configuration Tool user manual (WFMN1) for information on how to configure and program locks.

Page 22: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

22 1-800-810-WIRE • www.sargentlock.com • A8032G

Cop

yrig

ht ©

201

6, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

04/3

0/16

Passport 1000 P1 PoE Mortise Lock

Notes

Page 23: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock
Page 24: Mortise Lock - intelligentopenings.com · ... or specifying and installing a new fire-rated opening, ... pursuant to Part 15 of the FCC Rules. ... Passport 1000 P1 PoE Mortise Lock

A8032G -04/16

SARGENT Manufacturing100 Sargent DriveNew Haven, CT 06511 USA800-810-WIRE (9473) • www.sargentlock.com

HID and iCLASS are registered trademarks of HID Global Corporation.

Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.

Copyright © 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience.