floor standing series · 2019. 3. 11. · rhr-1214-b r22 r410a non inverter floor standing series...
TRANSCRIPT
-
RHR-1214-B
R22
R410ANon Inverter
FloorStanding
Series
R410A
FVGN-0319-F
-
Indoor ModelType Outdoor Model CapacityRange (Btu/hr)
Floor Standing Product Line Up
TYPE
OF
REF
RIG
ERA
NT
• FVN30/40/50/60AV1L
• FVGR08/10NV1
• FVPGR10/13/15/18/20NY1
RN28/30CV1
28,000-29,000
36,000-55,000
80,000-100,000
100,000-200,000
RN35/40/50/61DY1
RUR08/10NY1
RUR13/15/18/20NY1
R41
0A
DIR
ECT
AIR
BLO
WD
UC
T C
ON
NEC
TIO
N
RUR10NY1
-
● Prominent temperature display● Real-time clock display● Easily accessible buttons
White display lights up to indicate modes and temperature settings when activated
KEY LOCK icon is displayed when activated to prevent children or others from tampering with the control buttons on the units
Activation and deactivation of keylock by pressing ‘SWING’ and ‘TURBO’ simultaneously for 5 seconds
Modern And Stylish DesignDaikin floor standing series is designed with stylish profile and classy control panel which could blend in any interior environment.
Aesthetic Black Control Panel The control panel comes with large button for ease operation. It provides a white LED light for clear display when activated.
Wireless Remote ControllerDaikin floor standing unit is incorporated with IR sensor for usage with wireles controller.
DGS01wireless controller
OFF State ON State
Space saving with style and functionality* Applicable to model FVN30AV1L-60AV1L only
Prod
uct F
eatu
res
Far Air ThrowThe floor standing is able to achieve air throw distance up to 25m*.* Note: Based on model FVN60AV1L
-
Removable Washable Saranet FilterRemoval of airborne dust particles through saranet filter ensures cleaner air supply.
Turbo ModeThis function is available in COOL and DRY modes. Upon activation, the unit will run at full power with the indoor fan running at high speed for 20 minutes. This will provide a fast cooling for immediate comfort.
Advanced Ion Plasma Technology For Air PurificationIon plasma generator remove airborne contaminates from the air we breathe, and thus create a refreshing environment .
Generator
Safety cache for prevention of access to electrical and mechanical parts during removal of filter.
Auto Random RestartIn the event of sudden power failure during operation, the system will automatically restart-ed from the last setting condition. This eliminates the need to restart manually after each power failure.
-
Easy OperationDigital Remote Control Comes Standard With Indoor UnitTemperature setting is possible by button operation. The set temperature is conveniently displayed on the LED.
50m maximum length and 30m maximum level difference to cover medium and large-scale building needs.
Note 1 : It cannot be used for FVGR08-10NV1, FVPGR10-20NY1Note 2 : It cannot be used for FVPGR10-20NY1
Prod
uct F
eatu
res
Design FlexibilityDesigned For Long Refrigerant Piping
Enhanced Varieties Of Factory ModificationAnd Optional Accessories
1
2
3
4
5
6
7
8
9
Note 1
Note 1 Note 2
3
1
2
4
89
6
7
5
On/Off button LED display
Compressor operation lamp.
Fan operation lamp.
Cool operation lamp.
Fan button
Temp. setting up
Temp. setting down
Mode button
Outdoor unit roof installation possible for plenty of leeway.
Max. length
Max. level difference
DirectAir Blow
Auto restartModify for central control adapter kit (DAT107A55)Change fan motor and pulleyDischarge grill plenum chamberSide discharge grillon discharge plenum chamberLower drain panFront suction high efficiency filter chamber
Fresh air inletRear suctionDrain pumpRemote sensor (Thermistor for suction air)All fresh air application
LCD remote controller2Intelligent touch controller2Central remote controller2Unified ON/OFF controller2Schedule timer3Remote sensor (thermostor for suction air)3Remote controller
Central control adaptor kit(external terminal for ON/OFF, abnormal)1
Standard modelFactory modificationContact sales formore information
DTA107A55
BRC1C62DCS601C51
DCS302CA61DCS301B61DST301BA61
KRCS01-1-
Low outdoor temp. 15˚C application and long pipe70m application
Front suction base flange for front suction highefficiency filter chamberSuction grill for front suction high efficiencyfilter chamber
DuctConnection
Type
Floor Standing Type
Fact
ory
Mod
ifica
tion
Opt
ion
-
--
-
-
Note: 1Wiring modification is needed on floor stand model to connect with central control ADP kit. 2Need to use central control adapter kit for option connection. 3Central control adapter kit and LCD remote controller is necessary for option connection.
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
DurabilityHeat Exchange Fins Provided With Anti-Corrosion Treatment
Flexible design and great liability for factory and offices* Applicable to model FVGR08NV1-10NV1, FVPGR10NY1-20NY1 only
-
SpecificationFVN30AV1L FVN40AV1L FVN50AV1L FVN60AV1L
RN30CV1
FVN40AV1L
RN35DV1 RN40DY1 RN50DY1 RN61DY1
Btu/hr 29,000 42,000 45,000 55,000
W 8,500 12,309 13,189 16,120
W 2,900 4,100 4,900 5,490
A 13.40 [6.58] [8.42] [9.35]
Btu/hr / W 10.00
FVN30AV1L
RN28CV1
28,000
8,208
2,840
13.0
9.86
36,000
10,550
3,860
17.10
9.33
71
10.24 9.18 10.02
V/Ph / Hz 220-240 / 1 / 50
l/s / CFM
Pa/in.wg
319 / 675 489 / 1,035 489 / 1,035 552 / 1,170
dBA 44 49 50 54
UNIT DIMENSION INDOOR UNIT 1,850 x 600 x 270
(H x W x D) OUTDOOR UNIT 753 x 855 x 328
INDOOR UNIT 42 45 48 51
OUTDOOR UNIT 57 95 84 105
LIQUID mm/in
GAS mm/in 19.05 / 3/4
RUNNING CURRENT, 1ø[3ø]
MODELINDOOR UNIT
OUTDOOR UNIT
TOTAL COOLING CAPACITY
INPUT POWER
COPPER PIPE SIZE
EER
POWER SOURCE
REFRIGERANT TYPE R410A
-
AIR FLOW
EXTERNAL STATIC PRESSURE
SOUND PRESSURE LEVEL(MEASURED IN SOUND ROOM)
mm
UNIT WEIGHT kg
DIRECT BLOW (AUTOMATIC LOUVER LEFT & RIGHT)AIR DISCHARGE
380-415 / 3 / 50
1,850 x 600 x 350
HEAT INSULATION BOTH LIQUID AND GAS PIPING
852 x 1,030 x 400
9.52 / 3/8
15.88 / 5/8
1. DUE TO PRODUCT INNOVATION, ALL SPPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO 5151 3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4. SOUND PRESSURE LEVELS ARE MEASURED IN ANECHOIC CHAMBER. DURING ACTUAL OPERATION, SOUND PRESSURE LEVEL WILL HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.5. THE RUNNING CURRENT MEASURED AT SITE MAY VARY FROM THE SPECIFICATIONS STATED
FVN30AV1L-60AV1L
1. DUE TO PRODUCT INNOVATION, ALL SPPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO 5151 3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4. SOUND PRESSURE LEVELS ARE MEASURED IN ANECHOIC CHAMBER. DURING ACTUAL OPERATION, SOUND PRESSURE LEVEL WILL HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.5. THE RUNNING CURRENT MEASURED AT SITE MAY VARY FROM THE SPECIFICATIONS STATED
FVGR08NV1-10NV1 , FVPGR10NY1-20NY1FVGR08NV1 FVGR10NV1 FVPGR13NY1 FVPGR15NY1 FVPGR18NY1 FVPGR20NY1
RUR08NY1 RUR10NY1
FVPGR10NY1
RUR10NY1 RUR13NY1 RUR15NY1 RUR18NY1 RUR20NY1
Btu/hr 80,000 100,000 120,000 160,000 180,000 200,000
W 23,447 29,308 35,170 46,893 52,755 58,617
W 10,000 11,200 14,900 17,800 21,200 24,800
A [16.8] [18.9] [24.3] [29.0] [34.6] [40.4]
Btu/hr / W 8.00 8.93
100,000
29,308
11,400
[19.2]
8.77 8.05 8.99 8.49 8.06
V/Ph / Hz
l/s / CFM 902 / 1,910 1,336 / 2,830
-
dBA 60 61
UNIT DIMENSION INDOOR UNIT 1,870 x 950 x 510 1,870 x 1,170 x 510 1,740 x 1,170 x 510
(H x W x D) OUTDOOR UNIT
INDOOR UNIT 107 143
OUTDOOR UNIT 203 206
150
206 243 319 322 329
LIQUID mm/in
GAS mm/in 22.23 / 7/8
MODELINDOOR UNIT
OUTDOOR UNIT
TOTAL COOLING CAPACITY
INPUT POWER
SOUND PRESSURE LEVEL(MEASURED IN SOUND ROOM)
mm
UNIT WEIGHT kg
RUNNING CURRENT, 1ø[3ø]
EER
POWER SOURCE
REFRIGERANT TYPE
COPPER PIPE SIZE
AIR DISCHARGE
380-415 / 3 / 50
R410A
DIRECT BLOW DUCT CONNECTION
2,001 / 4,240
147 / 0.59
1,336 / 2,830 2,700 / 5,720
62 63
1,870 x 1,470 x 720
AIR FLOW
12.7 / 1/2 15.88 / 5/8
28.58 / 1-1/8 34.93 / 1-3/8
1,870 x 1,170 x 720
1,680 x 930 x 765 1,680 x 1,240 x 765
180 240
Pa/in.wgEXTERNAL STATIC PRESSURE
BOTH LIQUID AND GAS PIPINGHEAT INSULATION
Head Office: Tel: 03-7953 8388 Fax: 03-7956 4371Email: [email protected], [email protected]
Branches: • Kedah Tel: 04-730 5670 • Penang Tel: 04-331 1670 • Perak Tel: 05-548 2307 • Negeri Sembilan Tel: 06-768 8969 • Melaka Tel: 06-288 1133
• Johor Tel: 07-557 7788• Pahang Tel: 09-567 6778• Kelantan Tel: 09-747 4578• Sabah Tel: 088-722 194• Sarawak Tel: 082-333 299
Authorized dealer:
www.daikin.com.my
123456