herald floor standing condensing boilers

7
Herald Floor Standing Condensing Boilers Outputs from 41 to 228kW at 50/30°C system design • Stainless Steel Heat Exchanger High Working Pressure – up to 11 bar • Low NO x emissions ≤40mg/kWh Integral SMART System controls compatible with MODBUS or BACNET • Con-X-us, app-based control ancillary Con-X-us™

Upload: others

Post on 11-Jan-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Herald Floor Standing Condensing Boilers

HeraldFloor StandingCondensing Boilers

• Outputs from 41 to 228kW at 50/30°C system design

• Stainless Steel Heat Exchanger

• High Working Pressure – up to 11 bar

• Low NOx emissions ≤40mg/kWh

• Integral SMART System controls compatible with MODBUS or BACNET

• Con-X-us, app-based control ancillary

Con-X-us™

Page 2: Herald Floor Standing Condensing Boilers

HeraldFloor StandingCondensing Boilers

Herald Gas Fired Condensing BoilersThe Herald range of floor standing Condensing Boilers comprises 8 models with heat outputs ranging from 41 to 228kW at a system design of 50/30°C. All models have low NOx emissions and seasonal efficiencies of up to 96.7% (Part L, Gross CV).

Herald is particularly suitable as a replacement product for old atmospheric boilers, and can offer significant savings on energy usage and carbon emissions.

Fully modulating pre-mix burner with 5:1 turndownAll 8 Herald condensing boilers feature advanced gas/air ratio controlled combustion

technology. This technology automatically adjusts fan speed according to heat demand and

providing the optimum proportions of gas and air to enter the burner. The 5:1 turndown

feature ensures that fuel consumption is matched to heat load from 20% to full load. Herald

boilers can therefore achieve the following efficiency levels :• Net Efficiency (full load) – up to 97.1%• Net Efficiency (part load) – up to 110.0%• Seasonal Efficiency (Part L2 Gross CV) – up to 96.6%• Seasonal Efficiency (ErP / Ecodesign) – up to 95.0%

Models HCB46CE and HCB61CE have outputs of 41 and 59kW respectively and under the ErP

Directive require Energy labels. Both models have Energy label A, and when installed with class

VI or VIII controls package, will qualify for Energy label A+.

Stainless Steel Heat ExchangerAt the heart of the Herald Boiler is a robust, grade

316l stainless steel heat exchanger which provides

superior resistance to corrosion and is supported by

a 10-year warranty.

Herald Boilers8 models available

Low NOx EmissionsHerald Boilers have Low NOx emissions, ranging

from 32 to 40mg/kWh depending upon model, and

therefore comply with the latest ErP Regulations

dated September 2018.

A++

A+

A B C D E F G

dB

2015 811/2013

kW

A

Lochinvar Limited HCB61CE

5260

A++

A+

A B C D E F G

dB

2015 811/2013

kW

A

Lochinvar Limited HCB46CE

3858

Page 3: Herald Floor Standing Condensing Boilers

Concentric Twin-Pipe* Conventional

Model Flue Dia mm

Max. equivalent

flue run

Flue Dia mm

Max. equivalent

flue run

Flue Dia mm

Max. equivalent

flue run

HCB46CE 80/125 30m 80-80 60m** 80 60mHCB61CE 80/125 30m 80-80 60m** 80 60mHCB86CE 100/150 30m 100-100 60m** 100 60m

HCB116CE 100/150 30m 100-100 60m** 100 60mHCB146CE N/A N/A 150-150 60m** 150 60mHCB176CE N/A N/A 150-150 60m** 150 60mHCB206CE N/A N/A 150-150 60m** 150 60mHCB236CE N/A N/A 150-150 60m** 150 60m

* Twinpipeflueassembliescanbesuppliedwithsingleorseparateterminals**Combinedlengthofairinletandexhaustoutlet

Maximum Flue lengths

SMART System ControlsMost condensing boilers on the market operate at similar levels of efficiency, with good system design and control being crucially important factors in ensuring that boiler operating efficiency matches expectations. A key feature of the Herald range is its integral Smart system controls, which include:

• Multi-coloured graphic display• Modulating pump control• Cascade management for up to 8 Herald boilers• Fault signal output to BMS with open protocol• Ability to programme Service company details into display – this information is displayed when a service becomes due• Indirect Hot Water Pasteurisation programme

New Build or Replacement projects• High Temperature Operation - Herald Boilers can operate at tempera-

tures of up to 88°C which makes them suitable for installation as replacements for traditional atmospheric boilers – consideration should be given to hydraulic separation where water quality cannot be guaranteed – we can provide Hydraulic Plate Separators as Ancillary items

• High Working Pressure – suitable for systems with up to 11 bar working pressure

• Compact Design / Small footprint – at just 394mm wide, Herald boilers will fit through a standard doorway and the low height (845 or 1080mm depending on model), provides installation flexibility where plant room height is restricted

Flue OptionsA range of flue options are available including traditional conventional flue or room sealed concentric or twin pipe and with flue runs of up to 60m.

Herald SMART system control

Con-X-us™

Con-X-us App-based Control This ancillary option allows the user to have full control of the Herald Boiler(s) using hand-held devices such as smart phones or tablets. Please see Con-X-us product literature and YouTube video for more information

Page 4: Herald Floor Standing Condensing Boilers

Pipework Header Assemblies for Herald BoilersMultiple Boiler installations have become popular in recent years with cascade control enabling the Boiler installation to maintain high efficiency levels across a wide range of heat demand periods. Built-in redundancy is also a further benefit, and ensures that heat and hot water is still provided in the event of component failure on a single boiler.

Pipework header assemblies’ are currently available for Herald boiler models HCB86, 116 and 146 and for any combi-nation from 1 to 4 boilers. They can also be provided for installations of greater than 4 boilers. For example, two 3-boiler assemblies can be provided for a 6-boiler installation.

Herald Boiler Pipework Header Assemblies are supplied in ‘kit form’ for final onsite installation and include the following components:• Flow and return pipework headers• Boiler inlet and outlet pipework• Gas manifold• Bolt sets• Gaskets• Gas pipe cap end• Flange blanking plates

Matched primary circulation pumps and Boiler expansion kits are also available as optional ancillaries

1 Boiler 2 Boilers 3 Boilers 4 Boilers

HCB8

6CE

A mm 695.5 1391 2086.5 2782B mm 309.2 309.2 618.4 927.6C mm 578.2 578.2 1156.4 1734.6D mm 502 502 502 502E mm 1080 1080 1080 1080

HCB1

16CE

A mm 695.5 1391 2086.5 2782B mm 292.7 292.7 585.4 878.1C mm 571.5 571.5 1143 1714.5D mm 686 686 686 686E mm 1080 1080 1080 1080

HCB1

46CE

A mm 695.5 1391 2086.5 2782B mm 292.5 292.5 585 877.5C mm 576 576 1152 1728D mm 800 800 800 800E mm 1080 1080 1080 1080

1 x Herald Header side view 2 x Herald Header rear view

Page 5: Herald Floor Standing Condensing Boilers

Typical Schematic Drawings

Herald boiler installation providing heating zone and also domestic hot water via an Indirect Hot Water vessel

Two-boiler Herald installation with low velocity header on Cascade Management system, providing system turndown ratio of 10:1

Indirect Water Heaters/CalorifiersWe can provide a range of Stainless steel and lined steel Indirect Water Heaters / Calorifiers with storage capacities ranging from 300 to 2850 litres.

SquireIndirect Water Heaters

• Peak draw-off capacities up to 5456 litres in first hour

at a 50˚C temperature rise

• Clean out access for easy maintenance and inspection

• Up to 10.0 bar working pressure

• 3 year vessel warranty

Page 6: Herald Floor Standing Condensing Boilers

Herald Boilers – dimensions

Model

Description HCB46CE

HCB61CE

HCB86CE

HCB116CE

HCB146CE

HCB176CE

HCB206CE

HCB236CE

A Height mm 840 840 1080 1080 1080 1080 1080 1080B Depth mm 459 567 503 688 798 925 1024 1153C DepthincFlueOutlet mm 599 707 715 828 938 1065 1164 1293D Width mm 395 395 395 395 395 395 395 395E GasConnection mm 582 582 788 860 887 833 833 834F Air Inlet mm 540 540 860 860 887 915 915 915G WaterConnections mm 390 390 477 477 477 477 477 477H FlueOutlet mm 286 286 350 350 350 350 350 350I CondenseOutlet mm 167 167 230 230 230 230 230 230

For models HCB46CE and HCB61CE

For models HCB86CE, HCB116CE, HCB146CE, HCB176CE, HCB206CE and HCB236CE

Page 7: Herald Floor Standing Condensing Boilers

Lochinvar Ltd reserve the right to change specifications without prior notice LOC_11_0003 | ECH | December 20137 Lombard Way, The MXL Centre, Banbury, Oxon, OX16 4TJTel: +44(0) 1295 269 981, Fax: +44(0) 1295 271 640, Email: [email protected]

Lochinvar Ltd reserves the right to change specifications without prior notice

HERALD I 19_0004 I HCB I November 2019

For further information on the

Herald Floor Standing Condensing Boilers,

including ICM & User Instructions and

our full Warranty Terms and Conditions,

please visit our website: www.lochinvar.ltd.uk

ICOMEnergy Association

Technical Specification

Boiler model HCB46CE

HCB61CE

HCB86CE

HCB116CE

HCB146CE

HCB176CE

HCB206CE

HCB236CE

NominalInput(nett) kW 44.0 61.5 83.5 116.9 146.5 175.8 205.2 244.2NominalInput(gross) kW 39.6 55.4 75.2 105.3 132.0 158.4 184.9 220.0GasFlowRate(naturalgas) m3/hr 4.2 5.9 8.0 11.1 14.0 16.8 19.6 22.3Output@50/30°C kW 41.2 58.7 79.7 110.6 141.2 162.1 187.4 227.2Output@80/60°C kW 38.5 52.0 74.0 105.0 131.3 154.0 180.0 205.0Efficiency Data - Building RegulationsSeasonalEfficiency(GrossCV) % 95 94 94 93 94 95 95 95Efficiency Data - ErP and Energy Label EcodesignEnergyLabelrating A A n/a n/a n/a n/a n/a n/aSeasonalspaceheatingenergyefficiency % 95 94 94 93 94 95 95 95NOx Emmissions

NOxEmissions(AccordingtoEN15502)@0%O2 mg/kWh 38.1 32.0 34.4 40.0 40.0 36.0 36.2 35.0

NOxclassaccordingtoEN15502 6General DataDimensions(Height) mm 840 840 1080 1080 1080 1080 1080 1080Dimensions(Width) mm 395 395 395 395 395 395 395 395Dimensions(Depth) mm 459 567 503 688 798 925 1024 1153Water Content litres 4.9 6.4 9.1 12.9 15.9 15.9 18.9 21.6Weight(Empty) kg 75 79 102 129 138 154 168 184Weight(Full) kg 80 85 111 142 154 170 187 206FlowConnection(Inches) BSP 1¼" 1¼" 2" 2" 2" 2" 2" 2"ReturnConnection(Inches) BSP 1¼" 1¼" 2" 2" 2" 2" 2" 2"GasConnection(Inches) BSP ½" ½" ¾" 1" 1" 1" 1" 1"Flueconnection(Concentric) mm 80/125 80/125 100/150 100/150 N/A N/A N/A N/AFlueconnection(Twin-pipe) mm 80/80 80/80 100/100 100/100 150/150 150/150 150/150 150/150ElectricalRequirements 230V/1ph/50HᴢMaximumPowerConsumption W 120 144 180 180 204 322 322 322SoundPowerLevel LWA(db) 58 60 62 64 66 69 69 69MaximumFlueGasTemperature °C 120 120 120 120 120 120 120 120MaxFlowTemperature °C 88 88 88 88 88 88 88 88WorkingPressureMinimum bar 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5WorkingPressureMaximum bar 11 11 11 11 11 11 11 11

Energy Label, Product Fiche and ErP Data Table are available at www.lochinvar.ltd.uk

Ancillary Options • Matched primary circulation pump• Low velocity headers• Hydraulic Plate Separators• Boiler Expansion kits• Condensate neutralisation kit• Pressurisation units• Range of flue options (see page 3)

Ancillary Control Options• BACnet interface module• MODBUS interface module• Con-X-us app-based remote control• Outside air sensor for weather compensation control• DHW vessel sensor

Complementary Products for the generation of Domestic hot water• Indirect Water Heaters / Calorifiers• Packaged Plate Heat Exchangers• Direct gas-fired Water Heaters