floor standing - daikin...specifica on for floor standing, cooling only (r410a) floor standing a...

9
PLXSMT1724 Floor Standing FVRN-A Series FVQ-C Series (Super Inverter) COOLING ONLY [50Hz] 220V-240V

Upload: others

Post on 12-May-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

PLXSMT1724

Floor Standing FVRN-A Series

FVQ-C Series (Super Inverter)

COOLING ONLY [50Hz] 220V-240V

Page 2: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

1

FLOOR STANDING TYPE

FVRN71/100/125/140AXV1

Wired controller:BRC51A62

Wireless controller:BRC52A62

tinu htiw deilppus *lanoitpo *

Far air flowThe Daikin floor standing is able to achieve air flow distanceas far as 25m (size 140) which is about the size of a basketball court.

2.44

1.22

0.00

V_r (m/s)Global

25m

SERUTAEF LORTNOCGNICIVRES & KROWSSENILNAELCTROFMOC

Aut

o sw

ing

Sw

itcha

ble

fan

spee

d

Pro

gram

me

“Dry

Two

sele

ctab

le te

mpe

ratu

rese

nsor

Tim

er s

elec

tor

Wee

kly

sche

dule

d tim

er

Was

habl

e sa

rane

t filte

r

Pre

-cha

rged

for u

p to

7.5

m

Sel

f dia

gnos

is

Aut

o ra

ndom

rest

art

Exte

rnal

com

man

d co

ntro

lus

ing

BA

G

Gro

up c

ontro

l by

Net

wor

k In

terfa

ce M

odul

e (N

IM)

*1 *1

*1 Applicable when wired controller is used.*2 The condenser comes with bare/blue fin. Gold fin condenser are optional.

OTHERS

Ant

i cor

rosi

on tr

eate

dhe

at e

xcha

nger

s

*2

Space saving with style andfunctionality

1

Page 3: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

Auto-swing modeThis unit uses its automatic horizontal swing louver to spread comfortable air flow to cool every corner of the room. Its vertical louvers are adjusted manually to match different interior spaces and partition as well as to avoid direct airflow.

User-friendly controlsThe unit comes with a stylish black control panel with white LED light for clear display. It comes with a keylock function to prevent setting change from unauthorised personnel.

Safety clipThe safety clip feature allows users to remove the washable saranet filter with ease during maintenance. At the same time, it also acts as a safety feature to prevent the users from reaching into the electrical and mechanical components.

Two selectable temperature sensors

Both indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air

conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor

Piping

Floor standing unit

Manual setting ofvertical airflow louversAuto horizontal swing

Off state On state

Keylock function:Activation / deactivation of keylock by pressing “SWING” and “TURBO” together for 5 seconds

Keylock icon displayed when activated

White display lights up to indicate modes and temperature settings when switched on

Additionally, this unit is incorporated with infrared sensor for usage with wireless controller which is supplied with the unit. Thus, it can be controlled using wireless controller for greater flexibility.

Switchable fan speedHigh/Medium/LowHigh setting provides maximum reach while low setting minimizes drafts.

Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.

Powerful operationNew powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings.

Indoor unit on/off switchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.

Easy maintenance

Safety clip

Space for water drain pumpThere is a space in the unit below the fan that allows users to install an external condensate water pump.* The condensate water drain pump is separately purchased and field installed.

Condensatewater

drain pump(Optional)

2

Page 4: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

Benefits of Inverter

Inverter control responds to load changes and causes minor temperature adjustments. Non-inverter control frequently turns ON and OFF in response to load fluctuations or load mismatch and causes large temperature swings.

Inverter system consumes less electricity, and soon recovers the difference in initial cost. This results in lower total cost.

Inverters operate without repeated On/Off operation.

Why is inverter technology economical?

Why is inverter technology more comfortable?

When temperature does not fluctuate much, the set temperature is maintained.

Tota

l cos

t =un

it pr

ice

+ co

st o

f ele

ctric

ity

Time

InverterNon inverter

Roomtemperature

Time

Too hot

Set temperature

Smalltemperaturefluctuation

Too coldToo cold

Largetemperaturefluctuation

Comfortable

Inverter

Non inverter

Non inverter

Inverter

Non inverter

Inverter air conditioner can adjust its cooling capacity according to the cooling load. This results in less power consumption.

repeatedly perform On (full-power)/Off (zero-power) operation. Inverter

to the cooling load. Since inverter air conditioners provide required

Cap

acity

rat

ioLo

ad r

atio

0

1.0

Non inverter cooling capacity

Inverter cooling capacity

On/Off operation

Worse efficiency

Partial load area

Rated condition

35

Cooling load

Continuous driving without stopping and starting is more fuel efficient.

Highway drivingInverter

Constantly stopping and starting consumes energy and is less fuel efficient.

City drivingNon inverter

Stop, go, stop ...

Recovery point

Inverters save more energy over time

3

Page 5: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

4

1VXA041NRVF1VXA521NRVF1VXA001NRVF1VXA17NRVF

1YXD041RR1YXD521RR1YXD001RR1VXC17RR

00055000540000400082h/utB

kW

W/W

21.6191.3127.1112.8

49.228.298.298.2

05/1/042-02205/1/042-02205/1/042-02205/1/042-022zH/hP/VylppuS rewoP

589/5801/0711538/539/5301548/549/5301035/526/576mfcwolF riA

15/35/4564/84/0544/74/9493/24/44ABdleveL erusserP dnuoS

0581058105810581mm thgieH

006006006006mm htdiW

053053053072mm htpeD

15845424gk thgieW teN

05/3/514-08305/3/514-08305/3/514-08305/1/042-022zH/hP/VylppuS rewoP

56068585ABdleveL erusserP dnuoS

258258258357mmthgieH

030103010301558mmhtdiW

004004004823mmhtpeD

501895975gkthgieW teN

Pipe Connec 25.925.925.925.9mmdiuqiL -no

Pipe Connec 50.9188.5188.5188.51mmsaG -no

Ind

oo

rO

utd

oo

r

Indoor Model Name

Outdoor Model Name

Nominal Cooling Capacity

Nominal EER

Max. Allowable Length m 45

Max. Allowable Eleva on m 25

45

25

45

25

45

25

Specifica on for Floor Standing, Cooling only (R410A)

FLOOR STANDING A SERIES

RR100/125/140DXY1RR71CXV1/RR71CXY1

FVRN71AXV1

RR71CXY1

28000

8.21

2.89

220-240/1/50

675/625/530

44/42/39

1850

600

270

42

380-415/3/50

58

753

855

328

57

9.52

15.88

45

25

FVRN71/100/125/140AXV1F

Note : 1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB.2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m.

Page 6: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

5

New airflow control for more comfort

Accessory required for indoor unit.

Option

BRC1E62 can be

incorporated into the

indoor unit.

(Wired Remote Controller)

Navigation Remote Controller

Note: Remote controller cable is not included and must be procured locally.

BRC1E62

FVQ50/60/71/100/125/140C

FLOOR STANDING TYPE

Page 7: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

6

Quiet operation

Quick and easy installation and maintenance

Lightweight indoor unitEnables smooth transport and installation of the indoor unit.

The grill will not open even upon impact.

Energy savingDC fan motor improves efficiency

Employs a safety lock function of suction grille

100C 125C 140C

High

Indoor unitSound pressure level

50/60/71C

50 51 5343

Middle 47 48 5141

Low 44 46 4838

dB(A)

39 47

100C 125C 140C

Weight

Indoor unit 50/60/71C

(kg)

Comfortable fan speed control

increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller.)

High fan speed mode

and uncomfortable changes in air temperature.

Programme "Dry"

(applicable for FVQ50-100)

difference between room temperature and set temperature.

Auto airflow rate is selectable

Example applications

When cooling

Turning louvers and upward and leaving and horizontal will reduce uneven room temperature.

New comfortable airflow control1) Left and right directions

2) Up and down directions Independent up-and-down airflow directions facilitate even room temperature and help save energy.

New unit

(by remote controller)

(by hand)

Freely select both up and down airflow direction with 8-louver (horizontal blade) setting.

Upper louver (1)

Upper interlocking louvers (4)

Lower interlocking louvers (2)

Lower louver (1)

Each set of louvers to can be independently adjusted. (Manual adjustment)

Auto swing direction is selectable from 3 patterns to suit the layout of the room.

Pattern 1 Swing wide across the front

When installed in the center of a wall. When installed in the corner of a room.

Pattern 2 Swing across left side Pattern 3 Swing across right side

Switchable fan speed: High/Middle/Low and Auto("Auto" is applicable when BRC1E62 is used.)

(Applicable when BRC1E62 is used.)

* For dust concentration of 0.15 mg/m3

Long-life filter (standard) requires no maintenance for about 1 year*

-Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).

-The periodical cleaning time for the filter can be shortened depending on the usage environment.

DIII-NET communication standardConnection to a centralised control system is available without option.

Page 8: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

FLOOR STANDING TYPE

Power supply 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz

ModelName

Indoor unit

Outdoor unit

Outdoor unit

kW

Btu/h

°CDB

°CWB

Cooling

Certified Operation range

Certified Operation range

Motor outputCompressorCoil

Indoorunit

Dimensions (HXWXD)

Colour

mmdB(A)

kWRefrigerant charge (R-410A)Sound pressure level3

Sound pressure level3 (H/M/L)

dB(A)

Dimensions (HXWXD) mmMachine weight kg

Piping connections

mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit

Machine weight kg

kg

Airflow rate (H/M/L)Fan

Outdoorunit

Colour

Heat insulation

Max. interunit piping length mmMax. installation level difference

Type

Fresh white

Both liquid and gas piping

mmOutdoor unit

Ivory white

kWCooling1Power consumption

cfm

Night quiet mode dB(A)

Cooling capacity1,2

Rated (Min. - Max.)

30

21 to 46

14 to 25

m3/min

50 (Equivalent length 70)

VP20 (I.D 20XO.D 26)

9.515.9

26.0 (Hole)

1,850X600X27039

595X845X30043

Hermetically sealed swing typeType Cross fin coil Micro channel

1.6 (Charged for 30 m)

635/565/49418/16/14

43/41/38

48

71

FVQ71CVEB

RZR71MVM

60

FVQ60CVE

RZR60MVM

50

FVQ50CVE

RZR50MVM

7.1 (3.2-8.0)

1.761.351.12

2.58

1.92

140

FVQ140CVEB

RZR140MVM

14.0(6.2-15.4)

5.89

4544

100

FVQ100CVEB

RZR100MVM

990X940X320

10.0 (5.0-11.2)

65

2.031.9 (Charged for 30 m)

988/883/77728/25/22

988/918/84728/26/24

1,059/988/91830/28/26

3.28

50/47/44

49

125

FVQ125CVEB

RZR125MVM

140

FVQ140CVEB

RZR140MYM

100

FVQ100CVEB

RZR100MYM

125

FVQ125CVEB

RZR125MYM

12.5 (5.7-14.0)

1,850X600X35047

4.62

53/51/4851/48/46988/883/777

28/25/22988/918/847

28/26/241,059/988/918

30/28/26

50/47/44 53/51/4851/48/46

52 54

73

49 52 54

W/WCOP 2.75

6.0 (2.6-6.3)

1.843.26

5.0 (2.3-5,6)

1.273.94 2.383.05 2.71

14.0(6.2-15.4)

5.89

10.0 (5.0-11.2)

3.28

12.5 (5.7-14.0)

24,200(10,900-27,300)

47,800(21,200-52,600)

34,100(17,100-38,200)

42,700(19,500-47,800)

20,500(8,900-21,500)

17,100(7,900-19,100)

47,800(21,200-52,600)

34,100(17,100-38,200)

42,700(19,500-47,800)

4.622.383.05 2.71

Wh/WhCSPF 4.334.765.91 4.104.07 4.58 4.104.07 4.58

Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

7

Page 9: Floor Standing - Daikin...Specifica on for Floor Standing, Cooling only (R410A) FLOOR STANDING A SERIES RR71CXV1/RR71CXY1 RR100/125/140DXY1 FVRN71AXV1 RR71CXY1 28000 8.21 2.89 220-240/1/50

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan.

Lot 60334, Persiaran Bukit Rahman Putra 3,Taman Perindustrian Bukit Rahman Putra,47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.http://www.daikinmalaysia.com/

Dealer

© All rights reserved.

●with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and

is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify

the application of any local legislation.

●parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can

● Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and

warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.

2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need

to install the outdoor unit close to the sea shore, contact your local distributor.

Warning

Caution

October 2017