PLXSMT1724
Floor Standing FVRN-A Series
FVQ-C Series (Super Inverter)
COOLING ONLY [50Hz] 220V-240V
1
FLOOR STANDING TYPE
FVRN71/100/125/140AXV1
Wired controller:BRC51A62
Wireless controller:BRC52A62
tinu htiw deilppus *lanoitpo *
Far air flowThe Daikin floor standing is able to achieve air flow distanceas far as 25m (size 140) which is about the size of a basketball court.
2.44
1.22
0.00
V_r (m/s)Global
25m
SERUTAEF LORTNOCGNICIVRES & KROWSSENILNAELCTROFMOC
Aut
o sw
ing
Sw
itcha
ble
fan
spee
d
Pro
gram
me
“Dry
”
Two
sele
ctab
le te
mpe
ratu
rese
nsor
Tim
er s
elec
tor
Wee
kly
sche
dule
d tim
er
Was
habl
e sa
rane
t filte
r
Pre
-cha
rged
for u
p to
7.5
m
Sel
f dia
gnos
is
Aut
o ra
ndom
rest
art
Exte
rnal
com
man
d co
ntro
lus
ing
BA
G
Gro
up c
ontro
l by
Net
wor
k In
terfa
ce M
odul
e (N
IM)
*1 *1
*1 Applicable when wired controller is used.*2 The condenser comes with bare/blue fin. Gold fin condenser are optional.
OTHERS
Ant
i cor
rosi
on tr
eate
dhe
at e
xcha
nger
s
*2
Space saving with style andfunctionality
1
Auto-swing modeThis unit uses its automatic horizontal swing louver to spread comfortable air flow to cool every corner of the room. Its vertical louvers are adjusted manually to match different interior spaces and partition as well as to avoid direct airflow.
User-friendly controlsThe unit comes with a stylish black control panel with white LED light for clear display. It comes with a keylock function to prevent setting change from unauthorised personnel.
Safety clipThe safety clip feature allows users to remove the washable saranet filter with ease during maintenance. At the same time, it also acts as a safety feature to prevent the users from reaching into the electrical and mechanical components.
Two selectable temperature sensors
Both indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians.* Temperature-sensor on indoor unit must be used when the air
conditioner is controlled from another room.** Wireless remote controller does not have a temperature-sensor
Piping
Floor standing unit
Manual setting ofvertical airflow louversAuto horizontal swing
Off state On state
Keylock function:Activation / deactivation of keylock by pressing “SWING” and “TURBO” together for 5 seconds
Keylock icon displayed when activated
White display lights up to indicate modes and temperature settings when switched on
Additionally, this unit is incorporated with infrared sensor for usage with wireless controller which is supplied with the unit. Thus, it can be controlled using wireless controller for greater flexibility.
Switchable fan speedHigh/Medium/LowHigh setting provides maximum reach while low setting minimizes drafts.
Timer selectorOperation starts when the preset time of the ‘on’ timer elapses and stops when the preset time of the ‘off’ timer elapses.
Powerful operationNew powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings.
Indoor unit on/off switchThe unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged.
Easy maintenance
Safety clip
Space for water drain pumpThere is a space in the unit below the fan that allows users to install an external condensate water pump.* The condensate water drain pump is separately purchased and field installed.
Condensatewater
drain pump(Optional)
2
Benefits of Inverter
Inverter control responds to load changes and causes minor temperature adjustments. Non-inverter control frequently turns ON and OFF in response to load fluctuations or load mismatch and causes large temperature swings.
Inverter system consumes less electricity, and soon recovers the difference in initial cost. This results in lower total cost.
Inverters operate without repeated On/Off operation.
Why is inverter technology economical?
Why is inverter technology more comfortable?
When temperature does not fluctuate much, the set temperature is maintained.
Tota
l cos
t =un
it pr
ice
+ co
st o
f ele
ctric
ity
Time
InverterNon inverter
Roomtemperature
Time
Too hot
Set temperature
Smalltemperaturefluctuation
Too coldToo cold
Largetemperaturefluctuation
Comfortable
Inverter
Non inverter
Non inverter
Inverter
Non inverter
Inverter air conditioner can adjust its cooling capacity according to the cooling load. This results in less power consumption.
repeatedly perform On (full-power)/Off (zero-power) operation. Inverter
to the cooling load. Since inverter air conditioners provide required
Cap
acity
rat
ioLo
ad r
atio
0
1.0
Non inverter cooling capacity
Inverter cooling capacity
On/Off operation
Worse efficiency
Partial load area
Rated condition
35
Cooling load
Continuous driving without stopping and starting is more fuel efficient.
Highway drivingInverter
Constantly stopping and starting consumes energy and is less fuel efficient.
City drivingNon inverter
Stop, go, stop ...
Recovery point
Inverters save more energy over time
3
4
1VXA041NRVF1VXA521NRVF1VXA001NRVF1VXA17NRVF
1YXD041RR1YXD521RR1YXD001RR1VXC17RR
00055000540000400082h/utB
kW
W/W
21.6191.3127.1112.8
49.228.298.298.2
05/1/042-02205/1/042-02205/1/042-02205/1/042-022zH/hP/VylppuS rewoP
589/5801/0711538/539/5301548/549/5301035/526/576mfcwolF riA
15/35/4564/84/0544/74/9493/24/44ABdleveL erusserP dnuoS
0581058105810581mm thgieH
006006006006mm htdiW
053053053072mm htpeD
15845424gk thgieW teN
05/3/514-08305/3/514-08305/3/514-08305/1/042-022zH/hP/VylppuS rewoP
56068585ABdleveL erusserP dnuoS
258258258357mmthgieH
030103010301558mmhtdiW
004004004823mmhtpeD
501895975gkthgieW teN
Pipe Connec 25.925.925.925.9mmdiuqiL -no
Pipe Connec 50.9188.5188.5188.51mmsaG -no
Ind
oo
rO
utd
oo
r
Indoor Model Name
Outdoor Model Name
Nominal Cooling Capacity
Nominal EER
Max. Allowable Length m 45
Max. Allowable Eleva on m 25
45
25
45
25
45
25
Specifica on for Floor Standing, Cooling only (R410A)
FLOOR STANDING A SERIES
RR100/125/140DXY1RR71CXV1/RR71CXY1
FVRN71AXV1
RR71CXY1
28000
8.21
2.89
220-240/1/50
675/625/530
44/42/39
1850
600
270
42
380-415/3/50
58
753
855
328
57
9.52
15.88
45
25
FVRN71/100/125/140AXV1F
Note : 1. Rated cooling capacities are based on the following conditions: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB.2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m.
5
New airflow control for more comfort
Accessory required for indoor unit.
Option
BRC1E62 can be
incorporated into the
indoor unit.
(Wired Remote Controller)
Navigation Remote Controller
Note: Remote controller cable is not included and must be procured locally.
BRC1E62
FVQ50/60/71/100/125/140C
FLOOR STANDING TYPE
6
Quiet operation
Quick and easy installation and maintenance
Lightweight indoor unitEnables smooth transport and installation of the indoor unit.
The grill will not open even upon impact.
Energy savingDC fan motor improves efficiency
Employs a safety lock function of suction grille
100C 125C 140C
High
Indoor unitSound pressure level
50/60/71C
50 51 5343
Middle 47 48 5141
Low 44 46 4838
dB(A)
39 47
100C 125C 140C
Weight
Indoor unit 50/60/71C
(kg)
Comfortable fan speed control
increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller.)
High fan speed mode
and uncomfortable changes in air temperature.
Programme "Dry"
(applicable for FVQ50-100)
difference between room temperature and set temperature.
Auto airflow rate is selectable
Example applications
When cooling
Turning louvers and upward and leaving and horizontal will reduce uneven room temperature.
New comfortable airflow control1) Left and right directions
2) Up and down directions Independent up-and-down airflow directions facilitate even room temperature and help save energy.
New unit
(by remote controller)
(by hand)
Freely select both up and down airflow direction with 8-louver (horizontal blade) setting.
Upper louver (1)
Upper interlocking louvers (4)
Lower interlocking louvers (2)
Lower louver (1)
Each set of louvers to can be independently adjusted. (Manual adjustment)
Auto swing direction is selectable from 3 patterns to suit the layout of the room.
Pattern 1 Swing wide across the front
When installed in the center of a wall. When installed in the corner of a room.
Pattern 2 Swing across left side Pattern 3 Swing across right side
Switchable fan speed: High/Middle/Low and Auto("Auto" is applicable when BRC1E62 is used.)
(Applicable when BRC1E62 is used.)
* For dust concentration of 0.15 mg/m3
Long-life filter (standard) requires no maintenance for about 1 year*
-Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).
-The periodical cleaning time for the filter can be shortened depending on the usage environment.
DIII-NET communication standardConnection to a centralised control system is available without option.
FLOOR STANDING TYPE
Power supply 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
ModelName
Indoor unit
Outdoor unit
Outdoor unit
kW
Btu/h
°CDB
°CWB
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressorCoil
Indoorunit
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R-410A)Sound pressure level3
Sound pressure level3 (H/M/L)
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate (H/M/L)Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
Fresh white
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCooling1Power consumption
cfm
Night quiet mode dB(A)
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50 (Equivalent length 70)
VP20 (I.D 20XO.D 26)
9.515.9
26.0 (Hole)
1,850X600X27039
595X845X30043
Hermetically sealed swing typeType Cross fin coil Micro channel
1.6 (Charged for 30 m)
635/565/49418/16/14
43/41/38
48
71
FVQ71CVEB
RZR71MVM
60
FVQ60CVE
RZR60MVM
50
FVQ50CVE
RZR50MVM
7.1 (3.2-8.0)
1.761.351.12
2.58
1.92
140
FVQ140CVEB
RZR140MVM
14.0(6.2-15.4)
5.89
4544
100
FVQ100CVEB
RZR100MVM
990X940X320
10.0 (5.0-11.2)
65
2.031.9 (Charged for 30 m)
988/883/77728/25/22
988/918/84728/26/24
1,059/988/91830/28/26
3.28
50/47/44
49
125
FVQ125CVEB
RZR125MVM
140
FVQ140CVEB
RZR140MYM
100
FVQ100CVEB
RZR100MYM
125
FVQ125CVEB
RZR125MYM
12.5 (5.7-14.0)
1,850X600X35047
4.62
53/51/4851/48/46988/883/777
28/25/22988/918/847
28/26/241,059/988/918
30/28/26
50/47/44 53/51/4851/48/46
52 54
73
49 52 54
W/WCOP 2.75
6.0 (2.6-6.3)
1.843.26
5.0 (2.3-5,6)
1.273.94 2.383.05 2.71
14.0(6.2-15.4)
5.89
10.0 (5.0-11.2)
3.28
12.5 (5.7-14.0)
24,200(10,900-27,300)
47,800(21,200-52,600)
34,100(17,100-38,200)
42,700(19,500-47,800)
20,500(8,900-21,500)
17,100(7,900-19,100)
47,800(21,200-52,600)
34,100(17,100-38,200)
42,700(19,500-47,800)
4.622.383.05 2.71
Wh/WhCSPF 4.334.765.91 4.104.07 4.58 4.104.07 4.58
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
7
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan.
Lot 60334, Persiaran Bukit Rahman Putra 3,Taman Perindustrian Bukit Rahman Putra,47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.http://www.daikinmalaysia.com/
Dealer
© All rights reserved.
●with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and
is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify
the application of any local legislation.
●
●parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can
● Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and
warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need
to install the outdoor unit close to the sea shore, contact your local distributor.
Warning
Caution
October 2017