substation interface unit n-8400rs...substation interface unit n-8400rs thank you for purchasing...

16
INSTALLATION MANUAL SUBSTATION INTERFACE UNIT N-8400RS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

Upload: others

Post on 05-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

INSTALLATION MANUAL

SUbSTATION INTerfAce UNIT N-8400rS

Thank you for purchasing TOA’s Substation Interface Unit.Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

Page 2: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

2

TAbLe Of cONTeNTS

1. SAfeTY PrecAUTIONS ............................................................................. 3

2. GeNerAL DeScrIPTION .......................................................................... 5

3. feATUreS ............................................................................................................ 5

4. NOMeNcLATUre AND fUNcTIONS ................................................. 6Front ............................................................................................................................. 6Rear ............................................................................................................................. 6

5. INSTALLATION .................................................................................................. 75.1. Equipment Rack Mounting .................................................................................... 7

5.1.1. Setting space ............................................................................................... 85.1.2. Caution when installing the unit .................................................................. 85.1.3. Mounting on the rack ................................................................................... 9

5.2. Desk-Top Installation ............................................................................................. 95.3. Wall Mounting ..................................................................................................... 10

6. WIrING .................................................................................................................. 116.1. Connection Diagram ............................................................................................ 116.2. Type of Cable ...................................................................................................... 136.3. Relations Between Core Diameter of Cable and Maximum Cable Length ......... 136.4. Removable Terminal Plug Connection ............................................................... 136.5. E-7000TB Terminal Board Wiring ....................................................................... 14

7. AcceSSOrIeS ................................................................................................. 15

8. OPTIONAL PrODUcT ................................................................................ 15

Page 3: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

3

1. SAfeTY PrecAUTIONS• Before installationoruse,besure tocarefully readall the instructions in thissection forcorrectandsafe

operation.• Besuretofollowalltheprecautionaryinstructionsinthissection,whichcontainimportantwarningsand/or

cautions regarding safety.• Afterreading,keepthismanualhandyforfuturereference.

Safety Symbol and Message conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first andunderstand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.

Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

WArNING

When Installing the Unit• Do not expose the unit to rain or an environment

where it may be splashed by water or other liquids, asdoingsomayresultinfireorelectricshock.

• Use the unit only with the voltage specified onthe unit. Using a voltage higher than that which is specifiedmayresultinfireorelectricshock.

• Do not cut, kink, otherwise damage nor modifythe power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing somay result in fire orelectric shock.

• Avoid installing or mounting the unit in unstablelocations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling downandcausingpersonal injuryand/orpropertydamage.

• Installtheunitonlyinalocationthatcanstructurallysupport the weight of the unit and the mounting bracket. Doing otherwise may result in the unit falling down and causing personal injury and/orproperty damage.

When the Unit is in Use• Should the following irregularity be found during

use, immediately disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer. Make no further attempt to operate the unit in thisconditionas thismaycausefireorelectricshock.· If you detect smoke or a strange smell coming

from the unit· If water or any metallic object gets into the unit · If the power supply cord is damaged (exposure of

the core, disconnection, etc.)· If it is malfunctioning (no tone sounds.)

• Topreventafireorelectricshock,neveropennorremove the unit case as there are high voltage components inside the unit. Refer all servicing to qualifiedservicepersonnel.

• Donotinsertnordropmetallicobjectsorflammablematerials in the ventilation slots of the unit's cover, asthismayresultinfireorelectricshock.

• Donottouchaplugduringthunderandlightning,asthis may result in electric shock.

Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personalinjury,and/orpropertydamage.

cAUTION

When Installing the Unit• Never plug in nor remove the power supply plug

with wet hands, as doing so may cause electric shock.

• Whenunpluggingthepowersupplycord,besuretograsp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supplycordmaycauseafireorelectricshock.

• Donotblocktheventilationslotsintheunit'scover.Doing so may cause heat to build up inside the unit and result in fire.Also, periodically clean theventilation slots of dust.

• Besuretofollowtheinstructionsbelowwhenrack-mountingtheunit.Failuretodosomaycauseafireor personal injury.· Installtheequipmentrackonastable,hardfloor.

Fix it with anchor bolts or take other arrangements to prevent it from falling down.

· When connecting the unit’s power cord to an AC outlet, use the AC outlet with current capacity allowable to the unit.

· The supplied rack-mounting screws can be used for the TOA equipment rack only. Do not use them for other racks.

When the Unit is in Use• Donotplaceheavyobjectsontheunitasthismay

cause it to fall or break which may result in personal injury and/or property damage. In addition, theobject itself may fall off and cause injury and/ordamage.

• Donotstandorsiton,norhangdownfromtheunitas this may cause it to fall down or drop, resulting in personalinjuryand/orpropertydamage.

Page 4: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

4

cONSeILS De SÉcUrITÉ• Avant l’installation ou l’utilisation, lire attentivement l’ensemble des instructions de cette section pour un

fonctionnement correct et sûr.• Veilleràrespecterlesprécautionsrecommandéesdanscettesection,laquellecontientdesmisesengardeet/ouprécautionsimportantesenmatièredesécurité.

• Aprèslecture,conservercemanuelàportéedemainpourconsultationultérieure.

Symboles de sécurité et conventionsLessymbolesetmessagesdesécuritédécritsci-dessoussontutilisésdanscettenoticepourprévenir toutdommagecorporeloumatérielpouvantrésulterd’unemauvaiseutilisation.Lireattentivementcettenoticepourcomprendreparfaitementlessymbolesetmessagesdesécuritéafindeprévenirtoutrisqueéventuel.

Indique une situation risquant d’entraîner des blessures graves, voire la mort, en cas de mauvaise manipulation.

Lors de l’installation de l’appareil

• Nepasexposerl’appareilàlapluieetleprotégerdetoutcontactavecdel’eauoud’autresliquidesafind’éviterunincendieouuneélectrocution.

• Utilisez l’appareil uniquement avec la tensionspécifiéesurlechargeur.L’utilisationd’unetensionsupérieure à celle spécifiée peut être à l’origined’unincendieoud’uneélectrocution.

• Nepascouper,entortiller,modifierouendommagerlecordond’alimentation.Enoutre,éviterd’utiliserlecordond’alimentationàproximitéd’unradiateuretne jamais placer d’objets lourds (y compris l’appareil lui-même) sur le cordon d’alimentation, car ceciprésenteunrisqued’incendieoud’électrocution.

• Évitezd’installeroudemonterl’unitédansunendroitinstable, tel qu’une table bancale ou une surface inclinée pour prévenir toute chute susceptiblede provoquer une blessure corporelle et/ou unedégradationmatérielle.

• Installer l’unité dans un endroit structurellementcapable de soutenir le poids de l’appareil et de la patte de montage.

L’appareil pourrait tomber et provoquer des blessures corporelleset/oudesdommagesmatériels.

Pendant l’utilisation de l’appareil

• En cas de survenue des irrégularités suivantespendant l’utilisation,débrancher immédiatement lafiche du cordon d’alimentation de la prise secteur et contacter le représentant TOA le plus proche.Ne pas essayer pas d’utiliser l’appareil dans cesconditions sous peine de provoquer un incendie ou uneélectrocution.

·Détection de fumée ou d’une odeur inhabituelleémanantdel’appareil.

· Pénétration d’eau ou d’un objetmétallique dansl’appareil

· Dégradation du cordon d’alimentation (âme ducâbledénudée,déconnexionetc.).

· Dysfonctionnement(absencedetonalité).

• Pourempêcherun incendieouuneélectrocution,ne jamais ouvrir ni ne retirer le boîtier de l’appareil, enraisondelaprésencedepiècesàhautetension.Lamaintenancedel’appareildoitêtreconfiéeàuntechnicienaprès-ventequalifié.

• Nepasinsérernilaissertomberd’objetsmétalliquesoudematériaux inflammablesdans leséventsdeventilation du capot de l’appareil sous peine de provoquerunincendieouuneélectrocution.

• Ne pas toucher la fiche du cordon d’alimentationpendantunorage-Risqued’électrocution.

ATTeNTIONIndique une situation risquant d’entraîner des blessuresmoyennementgravesoumineures,et/oudesdommagesmatériels.

Lors de l’installation de l’appareil

• Ne jamais brancher, ni débrancher la fiche ducordon d’alimentation avec les mains mouillées.Risqued’électrocution.

• Pour débrancher le cordon d’alimentation, veilleràletenirparsafiche;nejamaistirerdirectementle cordon. Utiliser l’appareil avec un cordon d’alimentation endommagé peut présenter unrisqued’incendieoud’électrocution.

• Nepasobstruerlesfentesdeventilationsurlecapotdel’unitésouspeinedeprovoqueruneaccumulationdechaleuràl’intérieurdel’appareil,pouvantaboutiràunincendie.Nettoyerrégulièrementlesencochesde ventilation.

AVerTISSeMeNT

Page 5: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

5

• Respecterlesinstructionsci-dessouspourmonterl’appareilenbâti.Risqued’incendieoudeblessurecorporelle.

· Installerlebâtisurunsolstable.Lefixeràl’aidede boulons d’ancrage ou prendre des mesures pourempêcherqu’ilnechute.

· Pourbrancherlecordond’alimentationàunepriseCA,vérifierl’intensitémaximaledel’appareil.

· Les vis de montage en bâti fournies peuventseulementêtreutiliséespourlebâtidel’équipementTOA.Nepaslesutiliserpourd’autresbâtis.

Pendant l’utilisation de l’appareil

• Ne pas placer d’objets lourds sur l’appareil souspeine de le faire tomber ou de le rompre, ce qui présenteunrisquedeblessurescorporelleset/oude dommages matériels. Par ailleurs, l’objet lui-mêmepeuttomberetprovoquerdesblessureset/oudégâts.

• Ne pas placer d’objets lourds sur l’appareil souspeinedelefairetomber,cequiprésenteunrisquede blessures corporelles et/ou de dommagesmatériels.

2. GeNerAL DeScrIPTIONTOA'sN-8400RSisSubstationinterfaceunitusedfortheN-8000SeriesPacketIntercomSystem(IPnetworkcompatible intercom) employing packet audio technology*.Up to 16 substations can be connected using two pairs of twisted pair cables.ThemaximumnumberofLAN-connectableN-8000systemcomponentssuchasexchanges,IPstations,andvarious kinds of interface units is 192 in total.ConnectingtheunittotheLANpermitsthesubstationtoreceivepagingcallsandmakecallstoboththemasterstation connected to the IP intercom exchange and the IP master station.

* Technology related to audio transmission over a networkWarningThis is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

DeScrIPTION GÉNÉrALeL’unitéN-8400RSdeTOAestl’interfacedesous-stationutiliséepourlesystèmedepaquetintercomdessériesN-8000 (intercom compatible avec un réseau IP) utilisant une technologie de paquets audio*. Elle permetdebrancher jusqu'à16sous-stationsà l'aidededeuxpairesdecâblesàpaire torsadée. Ilestpossibledeconnecter jusqu'à192composantsdusystèmeN-8000compatibleLAN:centraux,stationsIPetdifférentstypesd'interfaces.Lebranchementdel'unitéauréseaulocalpermetàlasous-stationderecevoirdesappelsdenotificationetd'émettredesappelsverslastationprincipaleconnectéeaucentral intercomIPetverslastation principale IP.

*TechnologiedetransmissionaudiosurunréseauAvertissement CetéquipementestunproduitdeclasseA.Enenvironnementdomestique,ceproduitpeutprovoquerdesinterférencesradio.

3. feATUreS• Exchanges,IPstationsandvariouskindsofinterfaceunitscanbeconnectedoveradatacommunications

network.• Canbeconnectedtoanexistinglocalareanetwork(LAN)orwide-areanetwork(WAN).• Thededicatedsoftwareprogramenablescentralizedcontrolwithapersonalcomputer.• Systemmaintenance(verifyingoperationlogandLinesupervision)canalsobeperformedwithapersonal

computer and Internet browser.

cArAcTÉrISTIQUeS • Unréseaudecommunicationdedonnéespermetlaconnexiondecentraux,destationsIPetdedifférents

types d’interfaces. • Peutêtreconnectéàunréseaulocal(LAN)ouétendu(WAN)existant.• Logicieldédiépermettantuncontrôlecentraliséàpartird’unPC.• La maintenance du système (vérification du journal d’opérations et supervision des lignes) peut aussi

intervenir via un ordinateur personnel et un navigateur Internet.

Page 6: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

6

4. NOMeNcLATUre AND fUNcTIONS[front]

1 2 3 4 5

1. reset key [reSeT]Pressing this key reactivates the unit.

2. LNK/AcT indicator [LNK/AcT] (Green)Lightswhenconnectedtoanetwork,andflasheswhile transmitting or receiving data.

3. Status indicator [STATUS] (red)Continuously lights while data is written to an internal storage medium (FlashMemory), and flashes to indicate such unit malfunctions asinternal cooling fan failure.

4. Power indicator [POWer] (Green)Lights when power is supplied to the unit.

5. MAc addressThis is the MAC address* for the unit. Since the relationship of each unit location to its MAC address is established when setting the network attributes, keep track of this relationship for later use.

* The inherent address assigned to each network component, expressed in 12-digit hexadecimal notation.

[rear]6 7 8

10

9

6. Ac inletConnect the supplied power cord.NoteIf there is a danger of lightning strikes, insert an appropriate surge arrester into the power line.

7. cord clampPass the power cord through this clamp to ensure that the plug does not pull out when the unit is mounted to a wall. (Refer to p. 10.)

8. Substation connection terminals [LINe 1 – 16]Connect substations to these terminals using two pairs of twisted pair cables.Use the supplied removable terminal plug for connection.Refer to p. 13 "Removable Terminal Plug Connection."

9. Network connection terminal [LAN]Connects a 10BASE-T- or 100BASE-TX-compatible network. (Ethernet RJ-45 jack)

10. functional earth terminal [SIGNAL GND]Ground this terminal.Note: This terminal is not for protective earth.

Page 7: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

7

5. INSTALLATIONTheN-8400RScanbeinstalledinanyofthreeways:Equipment rack mounting, Desk-top installation, and Wall mounting.

INSTALLATION L’unitéN-8400RSpeutêtre installéedetroismanières :Montageenbâti,Montagesurbureau,etMontagemural.

5.1. equipment rack Mounting

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma)specifiedbythemanufacturer.

B)ReducedAirFlow-Installationoftheequipmentinarackshouldbesuchthattheamountofairflowrequiredfor safe operation of the equipment is not compromised.

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."

TheN-8400RScanbemountedontheCR-273,CR-413,orstandardEIA19"Equipmentrack.For the CR-273 and CR-413 Equipment rack assembly or BU-412 Blower unit installation, read the installation manual supplied with the rack.

NoteWheninstallingtheBlowerunitandN-8400RS,laytheequipmentrackdownface-uptodoinstallationworksafely.SincetheBlowerunitisinstalledfromtheinsideoftherack,besuretoinstallitfirst,beforemountingthe other components.

Montage en bâti

A) Température ambiante élevée - si l’appareil est installé dans un bâti fermé ou en même temps qued’autresappareils,latempératureàl’intérieurrisquededevenirsupérieureàlatempératureambiante.Parconséquent,veilleràinstallerl’équipementdansunenvironnementcompatibleàlatempératureambiantemaximumspécifiéeparlefabricant.

B) Débitd’airréduit-L’installationdel’équipementenbâtinedoitpascompromettreledébitd’airnécessaireàuneutilisationsûredel’équipement.

C) Chargemécanique-Lemontagedel’équipementenbâtinedoitpasentraînerdedangerdûàunesurchargemécaniqueinégale.

D) Surcharge du circuit - rester vigilant lors de la connexion de l’équipement au circuit d’alimentation etaux conséquences d’une surcharge des circuits sur la protection contre les surintensités et les câblesd’alimentation. Tenir compte des indications de la plaque nominale de l’appareil.

E) Veiller à toujours garantir l’intégrité de la prise demise à la terre. Faire particulièrement attention auxconnexionsd’alimentationendehorsdesbranchementsdirectsaucircuitdedérivation(parexempleàl’aidede multiprises).

L’unitéN-8400RSpeutêtremontéeenbâtiCR-273,CR-414ouEIA19”standard.Pourinstallerl’équipementenbâtiCR-273etCR-413,ouinstallerleventilateurBU-412,reportez-vousaumanueld’installationfourniaveclebâti.

remarquePourinstallerleventilateuretl’unitéN-8400RS,posezlebâtiàplatpoureffectuerl’installationentoutesécurité.Leventilateurétantinstallédepuisl’intérieurdubâti,soninstallationdoitinterveniravantcelledetouslesautrescomposants.

Page 8: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

8

5.1.1. Setting space

For maintenance works, allow much space between the wall and Equipment rack.

espace à prévoir

Prévoyez un espace suffisant entre lemur et le bâti enprévisiondestravauxdemaintenance.

N-8400RS

50 cm 50 cm

1 m

50 cm

Perforated panels

Equipment rack

N-8400RS

Bâti

Panneau perforé

5.1.2. caution when installing the unitAvertissement lors de l’installation de l’appareil

Do not stack up 3 Substation interface units or more. If 2 or more units are mounted in the Equipment rack, be sure to mount the perforated panel of 1-unit size (PF-013B) or more above and below every 2 units.

N’empilezpasplusde3unitésd’interfaceavec les sous-stations. Si vous montez au moins 2 unités enbâti, n’oubliez pas d’installer aumoins unpanneau perforé correspondant à la tailled’uneunité(PF-013B)entrechaqueunité.

Do not block the ventilation slots in the unit’s cover. Doing so maycauseheattobuildupinsidetheunitandresultinfire.cAUTIONNe pas obstruer les fentes de ventilation sur le capot del’appareil, sous peine de provoquer une accumulation de chaleur àl’intérieurdel’appareil,pouvantaboutiràunincendie.

ATTeNTION

Page 9: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

9

5.1.3. Mounting on the rackMontage en bâti

Step 1. Installtherack-mountingbrackettotheN-8400RS.

Step 2. MounttheN-8400RSontheEquipmentrack.

Étape 1. Installezlapattedemontageenbâtisurl’unitéN-8400RS.

Étape 2. Montezl’unitéN-8400RSenbâti.

5.2. Desk-Top Installation

WheninstallingtheN-8400RSonadesk,securethesuppliedplasticfeettothebottomsurfaceoftheN-8400RSusing the supplied machine screws.

Installation sur un bureau

Pourinstallerl’unitésurunbureau,installezlespiedsenplastiquefournissurlefonddel’appareilàl’aidedesvis fournies.

N-8400RS

Rack mounting screw 5 x 12 with plain washer (accessory)

Rack mounting bracket (accessory)

Tapping screw 3 x 8 (accessory)

Patte de montage (accessoire)

Vis-taraud 3 x 8(accessoire)

12

(accessoire) Vis de montage en bâti 5 x 12 avec rondelle simple

Plastic foot (accessory)

Machine screw M3 x 8 (accessory)

Vis de mécanique M3 x 8(accessoire)

Pied en plastique(accessoire)

N-8400RS

Page 10: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

10

5.3. Wall Mounting

Step 1. Install the optional YC-850 Wall-mounting brackettotheN-8400RS.

Step 2. MounttheN-8400RSonthewall.Notes• Useappropriatescrewsfortheconstruction

of wall.• Woodscrews3.5x20aresuppliedwiththe

YC-850.• The socket-outlet shall be installed near

the equipment and the plug (disconnecting device) shall be easily accessible.

Montage mural

Étape 1. InstallezlapattedemontageenbâtiYC-850fournie.

Étape 2. Montezl’unitéN-8400RSaumur.remarques • Utilisezdesvisadaptéesàlastructuredumur.• L’unitéYC-850estlivréeavecdesvisàbois3,5x20.• Laprisedoitêtreinstalléeàproximitédel’équipementetlafiche(dispositifdedéconnexion)doitêtrefacilementaccessible.

N-8400RS

Machine screw M3 x 6(supplied with the YC-850)Vis de mécanique M3 x 6(fournie avec l'unité YC-850)

Wall surface

Wood screw 3.5 x 20 (supplied with the YC-850)

Protect against disconnection (Power supply plug)

Power supply cordCordon d'alimentation

Vis à bois 3,5 x 20 (fournie avec l'unité YC-850)

Surface murale

Cord clampCollier du cordon

Unlock cord clamp and run the power supply cord through it.NoteKeep the cable length between a power supply plug and cord clamp as short as possible.

Protection contre les ruptures d'alimentation (prise d'alimentation) Déverrouillez le collier à cordon et glissez-y le cordon d'alimentation.RemarqueLe câble entre la prise d'alimentation et le collier doit être aussi court que possible.

Page 11: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

11

6. WIrING6.1. connection Diagram

4P removable terminal plug (supplied with the N-8400RS)

N-8400RS Substation interface unit

To AC mains or a UPS (Uninterruptible power supply system)*

Note

RS-450, RS-460, RS-470, or RS-480

RJ-45 connector

To network

16 lines

To line 3 (orange)

Two pairs of twisted pair cable

To line 4 (yellow)

To line 1 (brown)

To line 2 (red)

Be sure to ground.

1 2 3

If there is a danger of lightning strikes, insert an appropriate surge arrester into the power line.

Tips

For more information on the RS-450, RS-460, RS-470, and RS-480, please refer to their respectiveinstallation manuals.

• • This figure represents the RS-450.

[General description of connection]For cables, refer to p. 13.

1. Power supply connectionConnect the supplied power supply cord to AC Mains or a UPS (Uninterruptible power supply).

About power supply cord handlingThe supplied power supply cord is designed for exclusiveusewiththeN-8400RS.Neveruseitwithotherequipment.

2. Substation connections(Refer to p. 13 "Removable Terminal Plug Connection.")

3. Network connectionCan be connected to a network of 10BASE-T/100BASE-TXinauto-sensing.Use a straight through cable of UTP category 5 or more for this connection.

* Select an appropriate UPS taking into consideration the total power consumption of all system components and the required backup time. On-line uninterruptible power supply (UPS) is recommended.

referenceSubstationinterfaceunitN-8400RS:35W(rated)forCEversion,31W(rated)forCUversion8-Port10M/100MSwitchingHub:Approx.10W(Differsdependingonproducts.)

Page 12: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

12

cÂbLAGeSSchéma de branchements

Prise 4P amovible(fournie avec l'unité N-8400RS)

Unité d'interface de sous-station N-8400RS

RS-450, RS-460, RS-470, ou RS-480

Connecteur RJ45

16 lignes1 2 3

Ne pas oublier la mise à la terre.

Vers le réseauVers prise secteur CA (ou système d'alimentation sans interruption)*

RemarqueInstallez un parafoudre sur la ligne électrique pour protéger votre installation.

Vers ligne 1 (marron)

Vers ligne 2 (rouge)Vers ligne 3 (orange)

Vers ligne 4 (jaune)

Conseils• Cette figure représente l'unité RS-450.• Pour de plus amples informations sur les unités RS-450, RS-460, RS-470 et RS-480, reportez-vous aux manuels d'installation correspondants.

Deux paires de câbles à paire torsadée

[Description générale des branchements]

Pourlescâbles,reportez-vousàlapage13.

1. branchement à l'alimentationBranchez le cordon d'alimentation fourni sur la prise secteur CA (ou un système d'alimentationsans interruption).

À propos du maniement du cordon d'alimentationLe cordon d'alimentation fourni est exclusivement destinéàuneutilisationavecl'unitéN-8400RS.Nejamaisl'utiliseravecunautreéquipement.

2. branchement des sous-stations(Reportez-vous à la page 13, "RemovableTerminalPlugConnection.”)

3. connexion réseauPeutêtreconnectéàunréseau10BASET/100BASE-TXenauto-détection.UtiliseruncâbledroitUTPdecatégorie5oupluspour ce branchement.

*Choisissezlesystèmed'alimentationsanscoupureadaptéenprenantencomptelaconsommationélectriquetotale de l'ensemble des composants du système ainsi que la durée de récupération nécessaire. Nousrecommandonsunsystèmed'alimentationsanscoupureenfonctionnementcontinu.

référence Interfacepoursous-stationN-8400RS:35W(nominal)pourlaversionCE,31W(nominal)pourlaversionCU.8port10M/100Mconcentrateurdecommutation:Environ10W(enfonctiondesproduits.)

Page 13: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

13

6.4. removable Terminal Plug connection

Step 1. Strip a cable jacket of approx. 7 mm to expose inner cable.

Step 2. Loosen the terminal screws and insert the cables.

Step 3. Tighten the terminal screws securely.Notes• Tuglightlyonthecabletobesurethatitdoesnotpullfree.Ifthecablepullsfree,loosentheterminal

screw again and reconnect from Step 2. • Usethescrewdriverappropriatetothescrewstightenedintotheterminalplug.

7 mm For cables, refer to above "Type of Cable."

NoteDo not solder on exposed inner cables when using a stranded wire.

6.2. Type of cable

The types of cables are to be determined according to the following conditions.

• UTPCategory5straightthroughcablewithRJ45connectorsistobeusedforconnectingtoIPnetwork.• Thenumberofcablespairslaidshouldbedeterminedconsideringthepossibilityoffutureexpansionofthe

system.• Outdoorwiresshouldbeusedwherewiringpassesthroughinaccessibleareassuchasatticsorunderfloors

where the maintenance is not performed. Indoor wires may also be used, however, in case where there is no risk of deterioration due to exposure to heat, etc.

• Makesurethatthetwopairsoftwistedpaircablesareusedforwiringfromthesubstationinterfaceunittothesubstation (RS-450, RS-460, RS-470, and RS-480).

NoteSpecificationsrelatedtoconnectionsareasfollows.

Removableterminalplug(N-8400RSlineterminal) Conductordiameter: ø0.5–2mm(AWG12–24),Solidwire/Strandedwire

Clip terminal (E-7000TB) Conductordiameter: ø0.4–0.8mm(AWG20–26),Solidwire Outsidediameter: ø0.5mmorbelow

6.3. relations between core Diameter of cable and Maximum cable Length

For the maximum (two pairs of twisted pair) cable length between the substation interface unit and the substation (RS-450, RS-460, RS-470, and RS-480), refer to the following table.

Conductor diameter (mm)

Maximum cable length(km)

ø0.5 1.0ø0.65 1.5ø0.9 2.0

Page 14: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

14

Step 4. InsertthewiredterminalplugintotheterminalblockoftheN-8400RS.

3

2

4

Tighten

Removable terminal plug (accessory) Removable terminal block

N-8400RS rear panel

6.5. e-7000Tb Terminal board Wiring

For cable connection to the E-7000TB Terminal Board, use the optional YC-105 Clipping tool.Hooktheendofthecableontotheterminaland,withthecableendinhand,presstheYC-105downontotheterminal from above. Pressing down the YC-105 tool cuts off the excess cable end, securing the connection.

For cables, refer to p. 13, "Type of Cable."

Terminal board E-7000TBCable

Hook the cable onto the terminal without stripping the cablesheath.

Yellow Gray

Clipping tool YC-105 (Optional)

Bind the cables using the cord clamps supplied with the E-7000TB.

Cut end

Terminal

Page 15: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

15

7. AcceSSOrIeS

*ContainstheN-8000SettingsoftwareprogramandtheN-8000seriesinstructionmanual.TheSetupLauncheris automatically started when the supplied CD-ROM is inserted into the PC's drive.NoteIf your PC's CD drive is not compatible with the AutoRun function, the setup guide is not automatically started evenwhentheCDisinserted.Useeither"Explorer"or"MyComputer"toexecutethefollowingfiles,oruse[Start Run] in the Task Bar and enter the following command.<Drive where CD is placed> \index.htmlFor example, when placing the CD in the "d" drive, d:\index.html

AC power cord (2 m) .............................................. 1CD* (for PC setting, maintenance use) ................. 1Removable terminal plug (4 pins) ........................ 16Plastic foot ............................................................. 4

Machine screw M3 x 8 ........................................... 4Rack mounting bracket .......................................... 2Tapping screw 3 x 8 .............................................. 8Rack mounting screw 5 x 12 with plain washer ............. 4

Cordon d’alimentation CA (2 m) ............................ 1CD*(pourleparamétrageduPC,destinéauservicedemaintenance) ........... 1Prise amovible (4 broches) .................................. 16Pied en plastique ................................................... 4

VisdemécaniqueM3x8 ...................................... 4Pattes de montage ................................................ 2Vis-taraud3x8 ..................................................... 8Visdemontageenbâti5x12 avec rondelle simple .................................... 4

* Contient le logicieldeparamétragedel’unitéN-8000ainsiquelanoticederéférencedelasérieN-8000.Leprogrammedelancementdelaconfigurationdémarreautomatiquementlorsdel’insertionduCD-ROMfourni dans le lecteur.

remarqueSi le lecteurdeCDdevotrePCn’estpascompatibleaveclafonctiond’exécutionautomatique, l’assistantdeconfigurationnes’ouvrepasautomatiquementlorsdel’insertionduCD.Recherchezlesfichierssuivantsdans l’ExplorateurWindows,Poste de travail ou saisissez la commande ci-dessous après avoir lancé lafonction [Lancer L’exécution]delaBarredestâches.<LecteurdanslequelleCDaétéinséré>\index.html.Par exemple, pour l'insertion du CD dans le lecteur D d:\index.html

8. OPTIONAL PrODUcTWallmountingbracket: YC-850

PrODUIT eN OPTIONPattesdemontagemural: YC-850

AcceSSOIreS

Page 16: SUbSTATION INTerfAce UNIT N-8400rS...SUbSTATION INTerfAce UNIT N-8400rS Thank you for purchasing TOA’s Substation Interface Unit. Please carefully follow the instructions in this

Traceability Information for europeRenseignementsrelatifsàlatraçabilitéenEurope

Manufacturer:Fabricant:

TOA Corporation7-2-1,Minatojima-Nakamachi,Chuo-ku,Kobe,Hyogo,Japan

Authorizedrepresentative:Représentantagréé:TOAElectronicsEuropeGmbHSuederstrasse282,20537Hamburg,Germany

URL:http://www.toa.jp/133-06-00011-00

• DownloadourTOAProductsData,website(http://www.toa-products.com/international/) togettheup-to-dateversionforN-8000software,firmware,andInstructionmanuals.

• Thecurrentfirmwareversioncanbeconfirmedonthesystemmanagementscreendisplayedwhenthe browser establishes the connection to the Substation interface unit.

• ThesoftwareversionnumbercanbeconfirmedusingtheHelpmenu.• Theinstructionmanualversionnumbercanbeconfirmedbycheckingthepreparationdate(month

and year) shown at the lower right corner of the last page. Example:PreparedinSeptember2009:200909

Version update information

• Les fiches techniques des produits TOA sont disponibles au téléchargement sur le site web àl’adressehttp://www.toa-products.com/international/ où vous trouverezégalement les versions lesplusrécentesdulogiciel,dumicroprogrammeetdesnoticesderéférencedel’unitéN-8000.

• Pourvérifierlaversiondumicroprogramme,consultezl’écrand’administrationdusystèmequis’affichelorsquelenavigateurseconnecteàl’interfacedelasous-station.

• LaversiondulogicielestindiquéedanslemenuAide.• Lenumérodeversiondelanoticederéférenceestindiquédanslecoinintérieurdroitdeladernièrepageetcorrespondàladatedesapublication(moisetannée).

Exemple:Publiéenseptembre2009:200909.

Informations sur les versions de mise à jour