see detail a - commscope · 2019. 12. 30. · drawing number rev a mco dwn date a 20326396 jfm...
TRANSCRIPT
-
4
3
2
11
2
3
4
DCBA
CBA
1 4
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
DATEDWNMCOREVA
04-JUN-12JFM20326396A
31-JAN-17NERI8000019371B
SHT. OFDWN: J. SANTANA LOPEZ
DO NOT SCALE DRAWINGENGR: DAN HERZOG
BREV300001755411
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
CABLE ROUTINGSTEP 1
SEE DETAIL A
FOR RIBBONFIBER
FOR STRANDEDFIBER
DETAIL A
TIE SUBUNITS WITH LACING
(REF)
CLAMP LOCATION SHOWNON ASSEMBLY DRAWING(CLAMP CABLE BEFORE ROUTING)
ROUTE FIBER AS SHOWN
-
DRAWING NUMBER
4
3
2
11
2
3
4
DCBA
CBA
2 4
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
COMMSCOPE, INC.SHT. OF
DWN: J. SANTANA LOPEZDO NOT SCALE DRAWING ENGR: DAN HERZOG
BREV300001755411
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
CABLE ROUTINGSTEP 2
NOTES: 1.START WITH ROW 1 SEE CONNECTION TABLE (F/N 986) FOR CORRECT FIBERS. ROUTE FIBERS AS SHOWN TO ROW 1
ROW 12
ROW 11
ROW 10
ROW 9
ROW 8
ROW 7
ROW 6
ROW 5
ROW 4
ROW 3
ROW 2
ROW 1
-
DRAWING NUMBER
4
3
2
11
2
3
4
DCBA
CBA
3 4
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
COMMSCOPE, INC.SHT. OF
DWN: J. SANTANA LOPEZDO NOT SCALE DRAWING ENGR: DAN HERZOG
BREV300001755411
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
CABLE ROUTINGSTEP 3
ROW 12
ROW 11
ROW 10
ROW 9
ROW 8
ROW 7
ROW 6
ROW 5
ROW 4
ROW 3
ROW 2
ROW 1
NOTES: 2. ROUTE ROW 2 AS SHOWN. CONTINUE WITH ROWS 3, THROUGH 12. SEE CONNECTION TABLE FOR CORRECT FIBERS.
-
DRAWING NUMBER
4
3
2
11
2
3
4
DCBA
CBA
4 4
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
COMMSCOPE, INC.SHT. OF
DWN: J. SANTANA LOPEZDO NOT SCALE DRAWING ENGR: DAN HERZOG
BREV300001755411
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
FINISHED CABLE ROUTING
NOTES: 3. AFTER INSTALLING CABLE, EXTEND ALL ADAPTER PACKS. 4. PUSH ADAPTER PACKS BACK IN, CHECK FIBER FOR BENDS. REDRESS FIBERS IF NECESSARY.
ROW 12
ROW 11
ROW 10
ROW 9
ROW 8
ROW 7
ROW 6
ROW 5
ROW 4
ROW 3
ROW 2
ROW 1
Sheet 1Viewsnew_view_3new_view_14new_view_17
Sheet 2Viewsnew_view_5
Sheet 3Viewsnew_view_7
Sheet 4Viewsnew_view_9