Transcript
  • 4

    3

    2

    11

    2

    3

    4

    DCBA

    CBA

    1 4

    DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION

    DRAWING NUMBER

    COMMSCOPE, INC.

    DATEDWNMCOREVA

    04-JUN-12JFM20326396A

    31-JAN-17NERI8000019371B

    SHT. OFDWN: J. SANTANA LOPEZ

    DO NOT SCALE DRAWINGENGR: DAN HERZOG

    BREV300001755411

    CSIZE

    ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A

    DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN

    TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.

    CABLE ROUTINGSTEP 1

    SEE DETAIL A

    FOR RIBBONFIBER

    FOR STRANDEDFIBER

    DETAIL A

    TIE SUBUNITS WITH LACING

    (REF)

    CLAMP LOCATION SHOWNON ASSEMBLY DRAWING(CLAMP CABLE BEFORE ROUTING)

    ROUTE FIBER AS SHOWN

  • DRAWING NUMBER

    4

    3

    2

    11

    2

    3

    4

    DCBA

    CBA

    2 4

    DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION

    COMMSCOPE, INC.SHT. OF

    DWN: J. SANTANA LOPEZDO NOT SCALE DRAWING ENGR: DAN HERZOG

    BREV300001755411

    CSIZE

    ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A

    DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN

    TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.

    CABLE ROUTINGSTEP 2

    NOTES: 1.START WITH ROW 1 SEE CONNECTION TABLE (F/N 986) FOR CORRECT FIBERS. ROUTE FIBERS AS SHOWN TO ROW 1

    ROW 12

    ROW 11

    ROW 10

    ROW 9

    ROW 8

    ROW 7

    ROW 6

    ROW 5

    ROW 4

    ROW 3

    ROW 2

    ROW 1

  • DRAWING NUMBER

    4

    3

    2

    11

    2

    3

    4

    DCBA

    CBA

    3 4

    DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION

    COMMSCOPE, INC.SHT. OF

    DWN: J. SANTANA LOPEZDO NOT SCALE DRAWING ENGR: DAN HERZOG

    BREV300001755411

    CSIZE

    ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A

    DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN

    TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.

    CABLE ROUTINGSTEP 3

    ROW 12

    ROW 11

    ROW 10

    ROW 9

    ROW 8

    ROW 7

    ROW 6

    ROW 5

    ROW 4

    ROW 3

    ROW 2

    ROW 1

    NOTES: 2. ROUTE ROW 2 AS SHOWN. CONTINUE WITH ROWS 3, THROUGH 12. SEE CONNECTION TABLE FOR CORRECT FIBERS.

  • DRAWING NUMBER

    4

    3

    2

    11

    2

    3

    4

    DCBA

    CBA

    4 4

    DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION

    COMMSCOPE, INC.SHT. OF

    DWN: J. SANTANA LOPEZDO NOT SCALE DRAWING ENGR: DAN HERZOG

    BREV300001755411

    CSIZE

    ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A

    DRAWING REF,CABLE ROUTING, LEFT,CABLE EXIT DOWN

    TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIETARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.

    FINISHED CABLE ROUTING

    NOTES: 3. AFTER INSTALLING CABLE, EXTEND ALL ADAPTER PACKS. 4. PUSH ADAPTER PACKS BACK IN, CHECK FIBER FOR BENDS. REDRESS FIBERS IF NECESSARY.

    ROW 12

    ROW 11

    ROW 10

    ROW 9

    ROW 8

    ROW 7

    ROW 6

    ROW 5

    ROW 4

    ROW 3

    ROW 2

    ROW 1

    Sheet 1Viewsnew_view_3new_view_14new_view_17

    Sheet 2Viewsnew_view_5

    Sheet 3Viewsnew_view_7

    Sheet 4Viewsnew_view_9


Top Related