  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30MDate: 05-02-2012

    Designer: Syaiful Fikri

    CalcuLuX Road 7.6.1.0

    The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixedrelationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminairepositioning, reflection properties and electrical supply.

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    1. Project Description

    1.1 3-D Project Overview

    B BRP372 LED126NW 138W 22

    B

    B

    B

    BBBBBB

    B

    B

    B

    BBBBBB

    X

    YZ

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 2/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    1.2 Top Project Overview

    B BRP372 LED126NW 138W 22

    -22 -17 -12 -7 -2 3 8 13 18

    X(m)

    -6-1

    49

    1419

    2429

    3439

    44Y

    (m)

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 3/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    2. Summary

    2.1 Main Road

    Luminaire Type : BRP372 LED126NW 138W 220-240V DM2ELamp Type : 1 * Luxeon R x64LEDs Ra75.1Lamp Flux : 12623 lumenTilt90 (T) : 5.0 degGrid Method : CEN LuminanceProject Maintenance Factor : 0.90

    T

    O

    H

    WW C

    S

    Carriageway : Dual CarriagewayCentral Reserve (C) : 3.00 mRoad Width (W) : 7.00 mNumber of Lanes : 3Reflection Table : CIE C1Q0 of Table : 0.100Maintenance Factor : 0.90Installation : Twin CentralHeight (H) : 13.00 mSpacing (S) : 40.00 mOverhang (O) : 1.50 m

    Overall quality figures for the above road scheme.

    LuminanceAverage = 1.70 cd/m2Minimum = 1.18 cd/m2Maximum = 2.58 cd/m2Minimum/Maximum = 0.45Minimum/Average = 0.69Ul = 0.60

    GlareTI = 5.5 %

    Horizontal IlluminanceAverage = 16.8 luxMinimum = 10.5 luxMaximum = 29.3 luxMinimum/Maximum = 0.36

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 4/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3. Calculation Results

    3.1 Main L (O1): Graphical Table

    TI ( 1.17,-31.63, 1.50) = 5.5%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.17,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.70 0.69 0.45 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    B

    B

    B

    B

    1.8

    1.7

    1.5

    1.4

    1.3

    1.2

    1.2

    1.2

    1.2

    1.4

    1.5

    1.6

    1.7

    1.8

    1.9

    1.7

    1.6

    1.4

    1.4

    1.2

    1.2

    1.2

    1.3

    1.4

    1.5

    1.7

    1.8

    1.9

    2.0

    1.8

    1.6

    1.5

    1.4

    1.3

    1.2

    1.3

    1.3

    1.5

    1.5

    1.7

    1.9

    2.0

    2.1

    1.9

    1.7

    1.5

    1.4

    1.3

    1.3

    1.3

    1.4

    1.5

    1.6

    1.8

    2.0

    2.1

    2.2

    2.0

    1.7

    1.5

    1.5

    1.4

    1.3

    1.4

    1.4

    1.6

    1.7

    1.9

    2.1

    2.2

    2.3

    2.1

    1.8

    1.6

    1.5

    1.4

    1.4

    1.4

    1.5

    1.6

    1.7

    1.9

    2.2

    2.3

    2.3

    2.1

    1.9

    1.7

    1.5

    1.4

    1.4

    1.5

    1.5

    1.7

    1.8

    2.0

    2.2

    2.4

    2.4

    2.2

    1.9

    1.7

    1.6

    1.5

    1.5

    1.5

    1.6

    1.7

    1.9

    2.1

    2.3

    2.5

    2.6

    2.4

    2.1

    1.9

    1.7

    1.6

    1.5

    1.6

    1.6

    1.8

    2.0

    2.2

    2.5

    2.6

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 5/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.2 Main L (O1): Iso Contour

    TI ( 1.17,-31.63, 1.50) = 5.5%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.17,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.70 0.69 0.45 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    ) 1.2

    51.

    5

    1.5

    1.75

    1.75

    2

    22.

    252.252.

    5

    2.5

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 6/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.3 Main L (O1): Filled Iso Contour

    TI ( 1.17,-31.63, 1.50) = 5.5%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O1) (1.17,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.70 0.69 0.45 0.90

    B BRP372 LED126NW 138W 22

    2.5

    2.25

    2

    1.75

    1.5

    1.25

    -12 -7 -2 3 8 13 18

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 7/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.4 Main L (O2): Graphical Table

    TI ( 3.50,-31.63, 1.50) = 5.3%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (3.50,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.73 0.70 0.46 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    B

    B

    B

    B

    1.8

    1.7

    1.5

    1.4

    1.4

    1.2

    1.2

    1.2

    1.3

    1.4

    1.5

    1.6

    1.7

    1.8

    1.9

    1.8

    1.6

    1.4

    1.4

    1.3

    1.2

    1.2

    1.3

    1.5

    1.5

    1.7

    1.8

    1.9

    2.0

    1.8

    1.7

    1.5

    1.4

    1.3

    1.3

    1.3

    1.3

    1.5

    1.6

    1.8

    1.9

    2.1

    2.1

    1.9

    1.7

    1.5

    1.5

    1.3

    1.3

    1.3

    1.4

    1.5

    1.6

    1.8

    2.0

    2.2

    2.2

    2.0

    1.8

    1.6

    1.5

    1.4

    1.4

    1.4

    1.4

    1.6

    1.7

    1.9

    2.1

    2.2

    2.3

    2.1

    1.8

    1.6

    1.5

    1.4

    1.4

    1.4

    1.5

    1.6

    1.7

    2.0

    2.2

    2.3

    2.3

    2.1

    1.9

    1.7

    1.6

    1.5

    1.4

    1.5

    1.5

    1.7

    1.8

    2.0

    2.3

    2.4

    2.4

    2.2

    1.9

    1.7

    1.6

    1.5

    1.5

    1.5

    1.6

    1.7

    1.9

    2.1

    2.3

    2.4

    2.6

    2.3

    2.1

    1.8

    1.7

    1.6

    1.5

    1.6

    1.6

    1.8

    2.0

    2.2

    2.5

    2.6

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 8/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.5 Main L (O2): Iso Contour

    TI ( 3.50,-31.63, 1.50) = 5.3%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (3.50,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.73 0.70 0.46 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    ) 1.25

    1.5

    1.5

    1.75

    1.75

    2

    2

    2

    2.252.252.

    5

    2.5

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 9/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.6 Main L (O2): Filled Iso Contour

    TI ( 3.50,-31.63, 1.50) = 5.3%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O2) (3.50,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.73 0.70 0.46 0.90

    B BRP372 LED126NW 138W 22

    2.5

    2.25

    2

    1.75

    1.5

    1.25

    -12 -7 -2 3 8 13 18

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 10/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.7 Main L (O3): Graphical Table

    TI ( 5.83,-31.63, 1.50) = 5.0%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (5.83,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.74 0.71 0.48 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    B

    B

    B

    B

    1.8

    1.7

    1.6

    1.4

    1.4

    1.3

    1.2

    1.3

    1.3

    1.5

    1.5

    1.7

    1.8

    1.9

    1.9

    1.8

    1.6

    1.5

    1.4

    1.3

    1.3

    1.3

    1.3

    1.5

    1.6

    1.7

    1.9

    2.0

    2.1

    1.9

    1.7

    1.5

    1.5

    1.3

    1.3

    1.3

    1.4

    1.5

    1.6

    1.8

    2.0

    2.1

    2.2

    2.0

    1.7

    1.6

    1.5

    1.4

    1.3

    1.4

    1.4

    1.6

    1.7

    1.9

    2.1

    2.2

    2.2

    2.0

    1.8

    1.6

    1.5

    1.4

    1.4

    1.4

    1.5

    1.6

    1.7

    1.9

    2.2

    2.3

    2.3

    2.1

    1.8

    1.6

    1.5

    1.4

    1.4

    1.4

    1.5

    1.7

    1.8

    2.0

    2.2

    2.3

    2.3

    2.1

    1.8

    1.7

    1.6

    1.5

    1.4

    1.5

    1.5

    1.7

    1.8

    2.0

    2.2

    2.3

    2.4

    2.2

    1.9

    1.7

    1.6

    1.5

    1.5

    1.5

    1.6

    1.7

    1.9

    2.1

    2.3

    2.4

    2.5

    2.3

    2.0

    1.8

    1.7

    1.6

    1.5

    1.6

    1.6

    1.8

    2.0

    2.2

    2.4

    2.6

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 11/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.8 Main L (O3): Iso Contour

    TI ( 5.83,-31.63, 1.50) = 5.0%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (5.83,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.74 0.71 0.48 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    1.25

    1.5

    1.5

    1.75

    1.75

    2

    2

    22.2

    5

    2.25

    2.5

    2.5

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 12/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.9 Main L (O3): Filled Iso Contour

    TI ( 5.83,-31.63, 1.50) = 5.0%Grid : Main at Z = -0.00 mCalculation : Luminance towards CEN Observer (O3) (5.83,

    -60.00, 1.50) (cd/m2)Road Surface : CIE C1 with Q0 = 0.100

    Average Min/Ave Min/Max Project maintenance factor 1.74 0.71 0.48 0.90

    B BRP372 LED126NW 138W 22

    2.5

    2.25

    2

    1.75

    1.5

    1.25

    -12 -7 -2 3 8 13 18

    X(m)

    -41

    611

    1621

    2631

    3641

    Y(m

    )

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 13/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.10 Main Eh: Graphical Table

    Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)

    Average Min/Ave Min/Max Project maintenance factor 16.8 0.63 0.36 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -6-1

    49

    1419

    2429

    3439

    44Y

    (m)

    B

    B

    B

    B

    21

    19

    17

    15

    13

    11

    11

    11

    11

    13

    15

    17

    19

    21

    22

    20

    17

    15

    13

    11

    11

    11

    11

    13

    15

    17

    20

    22

    23

    21

    18

    15

    13

    11

    11

    11

    11

    13

    15

    18

    21

    23

    24

    21

    18

    15

    13

    11

    11

    11

    11

    13

    15

    18

    21

    24

    24

    22

    18

    15

    13

    11

    11

    11

    11

    13

    15

    18

    22

    24

    25

    22

    19

    15

    14

    12

    11

    11

    12

    14

    15

    19

    22

    25

    26

    23

    19

    16

    14

    12

    11

    11

    12

    14

    16

    19

    23

    26

    27

    24

    20

    17

    14

    12

    12

    12

    12

    14

    17

    20

    24

    27

    29

    26

    22

    18

    15

    13

    12

    12

    13

    15

    18

    22

    26

    29

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 14/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.11 Main Eh: Iso Contour

    Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)

    Average Min/Ave Min/Max Project maintenance factor 16.8 0.63 0.36 0.90

    B BRP372 LED126NW 138W 22

    -18 -13 -8 -3 2 7 12 17 22

    X(m)

    -6-1

    49

    1419

    2429

    3439

    44Y

    (m)

    15

    15

    20

    20

    25

    25

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 15/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    3.12 Main Eh: Filled Iso Contour

    Grid : Main at Z = -0.00 mCalculation : Horizontal Illuminance (lux)

    Average Min/Ave Min/Max Project maintenance factor 16.8 0.63 0.36 0.90

    B BRP372 LED126NW 138W 22

    25

    20

    15

    -12 -7 -2 3 8 13 18

    X(m)

    -6-1

    49

    1419

    2429

    3439

    44Y

    (m)

    B

    B

    B

    B

    Scale1:250

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 16/17

  • ROAD LIGHTING PELINDO III (GRESIK)SECTION TYPICAL ROW 30M Date: 05-02-2012

    4. Luminaire Details

    4.1 Project Luminaires

    Xceed Medium FOT Sample(64LED700)BRP372 LED126NW 138W 220-240V 1xLuxeon R x64LEDs Ra75.1/3934

    Light output ratios DLOR : 1.00 ULOR : 0.00 TLOR : 1.00Ballast : 700mA Global DriverLamp flux : 12623 lmLuminaire wattage : 138.0 WMeasurement code : LVC1121498

    Note: Luminaire data not from database.

    750

    750

    0o 30o30o

    60o 60o

    90o 90o

    120o 120o150o 150o180o

    C = 180o C = 0o C = 270o C = 90o C = 195o Imax C = 15o

    Luminous Intensity Diagram (candela/1000 lumen)

    Philips Lighting B.V. - CalcuLuX Road 7.6.1.0 Page: 17/17