resilient bridge columns with copper-based shape memory...

17
Resilient Bridge Columns with Copper-Based Shape Memory Alloy Reinforcement M. ‘Saiid’ Saiidi, PhD, P.E., Professor, Director, CATBI [email protected] Sebastian Varela, PhD student [email protected] CEE Dept. - University of Nevada, Reno

Upload: vodiep

Post on 21-Aug-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Resilient Bridge Columns with Copper-Based Shape Memory Alloy Reinforcement

M. ‘Saiid’ Saiidi, PhD, P.E., Professor, Director, CATBI

[email protected]

Sebastian Varela, PhD student

[email protected]

CEE Dept. - University of Nevada, Reno

Overall Objective: Develop resilient bridge columns to allow bridge functionality after strong earthquakes

4 span bridge tested in 2008 • 110 ft. (33 m) long, 7.5 ft. (2.30 m) wide

• 266,000 lbs (120 Ton) total weight

Figures: Cruz-Noguez & Saiidi (2011)

Advanced materials: ECC Engineered Cementitious Composite: superior tensile ductility; reduces damage

Steel-RC SMA-RC SMA-ECC

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

0 0.01 0.02 0.03

Str

ess

(ksi

)

Strain

DfD ECC 56d tests - Target: 6 ksi

Sp. 1Sp. 2Sp. 3Sp. 4Sp. 5Sp. 6

Advanced materials: SMA NiTi (Nickel-Titanium) Superelastic Shape Memory Alloy (SMA).

0 1 2 3 4 5 6 70

20

40

60

80

Str

ess

(ksi

)

Strain (%)

NiTi sample test to fracture

Advanced materials: SMA CuAlMn (Copper-Aluminum-Manganese) SMA: cheaper and easier to machine than NiTi

0 5 10 150

10

20

30

40

50

60S

tres

s (k

si)

Strain (%)

CuAlMn sample test to fracture

NiTi vs. CuAlMn SMA

•Both exhibit good superelastic properties.

•NiTi is more expensive.

•CuAlMn has lower yield strength and elastic modulus.

•No studies on seismic performance of CuAlMn-reinforced members.

Cu-CIP column model • ¼ Scale.

• Detailed according to AASHTO 2011 LRFD seismic.

• ECC and SMA only in the plastic hinge.

• Footing, column body and head were RC.

Other details • 7.7 ksi (54 MPa) ECC on test day.

• Footing concrete = 5.5 ksi (38.5 MPa)

• Column and head conc. = 6.5 ksi (45.5 MPa)

• Round CuAlMn SMA rods provided by Furukawa Techno Material, Co. Ltd. (Japan) and machined in the U.S.

Varela, S., and M. Saiidi (2015), "Dynamic performance of novel

bridge columns with superelastic CuAlMn shape memory alloy and

ECC." International Journal of Bridge Engineering, Vol.2 No. 3.

Test setup and procedure

Shake table

Rigid link

Spreader beam

Mass-rig

Motion

Hydraulic rams

N S W

E

Input ground motions

0 5 10 15-1

0

1

Accele

rati

on

(g) RRS 228 (Rinaldi Receiving Sta.)

0 5 10 15-40-20

0204060

Velo

cit

y(f

t/s)

Unscaled time (s)

0 0.5 1 1.5 20

0.5

1

1.5

2

2.5

3

Period, T (s)

Sp

ectr

al

accele

rati

on

, S a (

g)

Target versus achieved spectra

Target

AchievedRun 7

Run 6

Run 5

Run 4

Run 3

Run 2

Run 1

Run 7: 1.57x Rinaldi =290% x DE

Observed damage after Run 7

Run 7 - N Run 7 - S

Figure 16. Broken SMA bars on the north side after cover removal.

A

B

A

B

Hysteretic behavior and parameters

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Lateral displacement (in.)

Lat

eral

fo

rce

(kip

s)

Run 1

Run 2

Run 3

Run 4

Run 5

Run 6

Run 7

Envelope

Bilin-idealized

-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12

-40

-30

-20

-10

0

10

20

30

40

50

Drift (%)

Lat

eral

fo

rce

(kN

)

Run

#

Max.

Drift +

Max.

Drift -

Res.

Drift

+ II+

1 0.48% -0.49% 0.01% 0.5 <0

2 1.06% -1.33% 0.03% 1.0 <0

3 2.39% -2.66% 0.02% 2.2 0.16

4 4.03% -3.07% 0.04% 3.7 0.36

5 5.80% -2.82% 0.08% 5.4 0.58

6 9.53% -2.23% 0.22% 8.9 >1

7 11.80% -2.71% 0.39% 11.0 >1

Analytical studies: OpenSees

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Lat

eral

fo

rce

(kip

s)

Run 1

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Run 2

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Run 3

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Run 4

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Run 5

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Run 6

-4 -2 0 2 4 6 8

-10

-5

0

5

10

Run 7

Lateral displacement (in.)

Analytical

Experimental

Conclusions Minimal damage and minor loss of capacity.

Nonlinear behavior took place in the plastic hinge region, no yielding or damage elsewhere.

Simple 2-D fiber model was able to match key test results with reasonable accuracy. Refinement of modeling method is warranted.

Using superelastic CuAlMn and ECC in the plastic hinge regions of bridge columns could allow bridges to stay functional after strong earthquakes.

Design guidelines under development.