personas m series - money handling · pdf filencr personas m series 5887 drive-up site...

222
Personas M Series 5887 Drive-Up Site Preparation And Installation B006-6356-C000 1204

Upload: vocong

Post on 05-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Personas M Series5887 Drive-Up Site Preparation And Installation

B006-6356-C0001204

Page 2: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NOTICE

This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws.

The product described in this book is a licensed product of NCR Corporation.

APTRA and Personas are trademarks of NCR Corporation.

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.

To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value of this book.

Address correspondence to:

NCR Financial Solutions Group LtdInformation SolutionsKingsway WestDundee,ScotlandDD2 3XX

© 2003, 2004By NCR CorporationDayton, Ohio U.S.A.All Rights Reserved

Page 3: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

iii

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Federal Communications Commission (FCC) Radio Frequency Interference Statement

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Canadian Class A Device Declaration

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

Information to UserThis equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.

Caution NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.

Page 4: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

iv NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 5: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

v

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Revision Record

Revision Record

Date Page Description of Change

May 03 All Revision A: New publication

May 04 All Revision B: Update for cash acceptor, coin dispenser and cheque acceptor.

Dec 04 Chapter 1 Revision C: Update to “Installation And Service Clearances” section and “Hole In The Wall” illustrations.

Page 6: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Revision Record

vi NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 7: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Contents

Table of Contents

vii

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Preface .....................................................................................................xiiiSite Preparation ...............................................................................xiiiInstallation .......................................................................................xivOverview...........................................................................................xvCustomer Responsibilities .............................................................xviProduct Identification....................................................................xvii

Chapter 1Physical Requirements

Package Dimensions .............................................................................1-1Manoeuvring The ATM Into Position..........................................1-2

ATM Dimensions ..................................................................................1-3Before Collar Has Been Fitted .......................................................1-3Standard Collar ...............................................................................1-4Standard Collar With Advert Light .............................................1-4Severe Environment .......................................................................1-5Cheque Acceptor.............................................................................1-5Height And Depth To Main Facia Items .....................................1-6Ambient Lighting............................................................................1-7

Installation And Service Clearances ...................................................1-8Recommended Clearances.............................................................1-8Minimum Clearances ...................................................................1-10Exterior Wall..................................................................................1-12

Service Access Panels..........................................................................1-13Hole In The Wall..................................................................................1-14

Installation Categories..................................................................1-14Installing Through A Glass Wall ................................................1-14

Replacing 5088 With Modifications To Hole In Wall.....................1-15Plinth Requirements .....................................................................1-15

Replacing 5688 With No Modifications To Hole In Wall ..............1-16Plinth Requirements .....................................................................1-16

Installing Through A New Hole .......................................................1-17Plinth Requirements .....................................................................1-17

Sealing The Hole In The Wall Against Cold And Water ...............1-18

Page 8: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Requirements For The Floor ..............................................................1-19Support Plinth ...............................................................................1-19

Mandatory Modifications To Plinth Or Floor .................................1-21Concrete Plinth ..............................................................................1-21Adjustable Plinth...........................................................................1-21ATM Installed Directly On To The Floor ..................................1-21Floor Loading ................................................................................1-22Security Bolts .................................................................................1-23Floor Covering...............................................................................1-23

Infill Panel Dimensions.......................................................................1-24Infill Panel (5088) ..........................................................................1-24Infill Panel (5688) ..........................................................................1-24

Internal Space Constraint For Fitting A Third Party Video Camera....................................................................................1-25

Chapter 2Electrical Requirements

Power Quality Distribution And Grounding Requirements ..........2-1AC Power Requirements ...............................................................2-1Input Voltage Setting......................................................................2-1Power Consumption.......................................................................2-1Power Cable .....................................................................................2-2Grounding Requirements ..............................................................2-2EMI Susceptibility ...........................................................................2-3EMI Emission...................................................................................2-3

Communications Requirements ..........................................................2-4High Order Communications Cable ............................................2-4Remote Device Cables ....................................................................2-6Internal Cables...............................................................................2-15

Chapter 3Environmental Requirements

Environmental Requirements ..............................................................3-1Temperature And Humidity .........................................................3-1Barometric Pressure........................................................................3-2Electromagnetic Compatibility (EMC) And Safety....................3-3Acoustics ..........................................................................................3-3Heat Dissipation..............................................................................3-3Air Flow............................................................................................3-3Temperature Rise ............................................................................3-3

viii NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 9: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Chapter 4Decal Requirements

Decal Dimensions ..................................................................................4-1Card Orientation Window.............................................................4-2Card Acceptance Decal ..................................................................4-2Clear Window .................................................................................4-3Advert Light ....................................................................................4-3Entry/Exit Slot Decals....................................................................4-4

Chapter 5Installation Accessories And Planning Check List

Installation Accessories ........................................................................5-1Planning Check List ..............................................................................5-2

Chapter 6Installation Procedure

Introduction............................................................................................6-1Installation Steps .............................................................................6-1Site Preparation ...............................................................................6-1Tools Required For ATM Installation ..........................................6-1Moving The ATM ...........................................................................6-2

Chapter 7Preparing The ATM For Installation

Removing The External Packaging From The ATM ........................7-1Inspecting The ATM For Damage ................................................7-1Installation Report Form................................................................7-2

Opening The ATM ................................................................................7-3How To Open The ATM ................................................................7-4How To Open The Cheque Acceptor Side-Box ..........................7-5

How To Unlock And Lock A Standard Security Enclosure ............7-6Keylocks ...........................................................................................7-7Combination Locks.........................................................................7-7Combination Lock And Separate Keylock ..................................7-9

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation ix

Page 10: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

How To Unlock And Lock An Electronic Lock...............................7-13Unlocking .......................................................................................7-13Locking ...........................................................................................7-14Emergency Opening Procedure..................................................7-15

How To Unlock And Lock A Controlled Access Electronic Lock 7-16Unlocking the Master Lock..........................................................7-17Locking the Master Lock..............................................................7-19Unlocking the Sub-Lock...............................................................7-19Locking the Sub-Lock...................................................................7-20

Removing The ATM From Its Pallet .................................................7-22

Chapter 8Installing The ATM – Physical Installation

Introduction............................................................................................8-1Installation Categories....................................................................8-1Connecting Cables ..........................................................................8-1

Fitting The Severe Environment Parts................................................8-2Dismantling The Severe Environment Parts...............................8-2Relocating The Position Of The EOP ...........................................8-4Removing The 80-Column Printer And Slide.............................8-5Fitting The Severe Environment Parts .......................................8-12

Positioning The ATM..........................................................................8-24Fitting An Infill Panel..........................................................................8-25

Infill Panel (5088) ..........................................................................8-25Infill Panel (5688) ..........................................................................8-26

Fitting The Collar.................................................................................8-28Fitting The Standard Collar With Facia Light...........................8-28Fitting The Standard Collar With Advert Light .......................8-33

Sealing The Collar And Bolting The ATM To The Plinth..............8-40

Chapter 9Installing The ATM – Internal Packaging And Cables

Removing The Internal Packaging......................................................9-1Module Locations...........................................................................9-1Operator Panel.................................................................................9-2Security Enclosure...........................................................................9-2Currency Dispenser ........................................................................9-3Cash Acceptor..................................................................................9-5Cheque Acceptor.............................................................................9-6PC Core.............................................................................................9-7

x NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 11: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Receipt And Journal Printers ........................................................9-8Magnetic Card Reader/Writer......................................................9-9Statement Printer ..........................................................................9-10

Connecting Cables To The ATM .......................................................9-12Internal Cables...............................................................................9-13Power Cable...................................................................................9-15Connecting External Cables ........................................................9-17

Chapter 10Configuring the ATM

Introduction..........................................................................................10-1Currency Cassette Configuration......................................................10-2Device Configuration..........................................................................10-3Communications Configuration .......................................................10-4

APTRA Self-Service Support .......................................................10-4S4I ....................................................................................................10-4

40-Column Printer Configuration .....................................................10-5Thermal Receipt And Journal Printers ......................................10-5Basic Configuration ......................................................................10-6Advanced Configuration And Calibration ...............................10-6Dot-Matrix Journal Printer ..........................................................10-9

80-Column Printer Configuration ...................................................10-11Letter Quality Document (LQD) Printers................................10-11Adjusting DIP Switch Settings ..................................................10-12Adjusting The LQD Printer Paper Hopper .............................10-14Adjusting The Contrast ..............................................................10-18

Chapter 11Fitting Decals To The ATM

Fitting The Decals................................................................................11-1Advert Light ..................................................................................11-1Card Orientation Window And Clear Window .......................11-1Entry/Exit Decals .........................................................................11-2Card Acceptance Decal ................................................................11-2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation xi

Page 12: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Appendix ATransient And Power Protection

AC Power Line Transient Protection .................................................A-1Data Line Transient Protection...........................................................A-3NCR Power Protection and Cabling Products .................................A-4

AC Power Line Transient Protection ..........................................A-4Data Line Transient Protection ....................................................A-5Uninterruptible Power Supplies ..................................................A-5Contact Information ......................................................................A-7

IndexIndex................................................................................................Index-1

User Feedback Form

xii NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 13: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

iii

xNCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Preface

Preface

Site PreparationChapter 1 to Chapter 5 of this document contain the information necessary for the preparation of a site conforming to NCR specifications. It is very important that the site complies with the requirements specified in these chapters because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct. Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customer’s business.

In addition to the need to comply with the requirements specified, electrical wiring and mechanical systems must also comply with all relevant codes, laws and regulations.

It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer.

For information and guidance only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation.

NCR staff will be available to answer questions relating to the contents of the chapters but, except where:

a the customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and

b the customer shall have entered into a formal contract with NCR for provision of the same.

No comment, suggestion or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or of its preparation and NCR will not be liable in respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.

Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason it is the customer’s responsibility to ascertain the extent of any such possible damage to his existing or planned business, and to effect full insurance in respect of it.

Page 14: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

InstallationChapter 6 to Chapter 11 are intended for NCR personnel or NCR customer personnel who are required to install an NCR Drive-Up Automated Teller Machine (ATM).

The chapters describe how to move the ATM from its point of delivery and install it in the required location.

The procedures are presented in six chapters with the following contents:

● Chapter 6 lists the steps and tools required to install an ATM, and details how to move the ATM to the installation site.

● Chapter 7 describes how to unpack the ATM and remove it from its pallet.

● Chapter 8 describes the installation of the ATM through the hole in the wall.

● Chapter 9 describes how to remove the internal packaging and how to connect cables.

● Chapter 10 describes the configuration procedure.● Chapter 11 describes how to fit decals to the front of the ATM.

The procedures, from Chapter 6 to Chapter 10, must be followed in sequence. The procedures in Chapter 11 can be carried out at any time, before or after the installation of the ATM.

xiv NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 15: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

Overview The NCR Personas M Series 5887 Drive-Up ATM is a self-service terminal which may be installed through any suitable exterior wall or kiosk.

The main functions of the 5887 are listed below:

● Dispensing notes● Cash Security● Depositing notes● Receipt printing● Journal printing● Statement printing● Mini-statement printing● Coupon printing● Account transactions:

● Transfers● Order cheque book

● Account enquiries:● Account balance● Next loan payment● Credit card limit● Interest rates

● Screen advertising and marketing.

Your ATM may not have all the functions in the list, as some are provided by optional features and some are dependent on the application that the ATM runs.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation xv

Page 16: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

Customer ResponsibilitiesThe customer must do or provide the following:

● When required by NCR, provide the NCR customer service representative with appropriate drawings that indicate: ● Location of the equipment● Site wiring (power and signal, paths and lengths) ● Location of other equipment capable of generating electrical

noise, electromagnetic interference, heat, etc.● Make building alterations necessary to meet wiring and other

site requirements.● Provide and install all communications cables, wall jacks,

special connectors, and associated hardware.● Provide and install necessary power distribution boxes,

conduits, grounds, lightning protection, and associated hardware.

● Make sure all applicable codes, regulations and laws (including, but not limited to, electrical, building, safety, and health) are met.

● Provide and install auxiliary power or other equipment as required.

● Provide storage or service areas as required.● Make sure the environmental requirements of the system/unit

are met.● Provide floor coverings and environmental systems that limit or

control static electricity build-up and discharge.● Install the product at a height which meets the accessibility

regulations of the relevant country.

xvi NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 17: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

Product IdentificationThe product is identified by a class type number, 5887, and a 4 digit model number which is printed on a label fixed inside the top cabinet of the ATM and above the receipt printer. The first two digits of the model number identify the major model (normally 01), the next two digits identify the minor model (normally 01). The serial number is unique to each ATM. The tracer number is used to identify where the ATM was built. Please quote all of the serial and tracer numbers, including the prefix, when making reference to the ATM.

Model: XXXX

Hz: 50/60 A:X.X

Serial: XX-XXXXXXXX

Tracer: XX-XXXXX

Vac: XXX

NCR Global Solutions Ltd.

Made in UK

Electromagnetic Compatibility

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.

This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio InterferenceRegulations of Canada.

‘’Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J’‘

Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescritesdans le Reglement sur le brouillage radioelectrique du Canada.

Class: 5887

LR 32207

LISTED649Automated Teller Machine24 Hour Service Level 1

UL

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation xvii

Page 18: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

xviii NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 19: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPhysical Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 1

Physical Requirements

Package Dimensions 1-1Manoeuvring The ATM Into Position 1-2

ATM Dimensions 1-3Before Collar Has Been Fitted 1-3Standard Collar 1-4Standard Collar With Advert Light 1-4Severe Environment 1-5Cheque Acceptor 1-5Height And Depth To Main Facia Items 1-6

Topmost Viewable Facia Item 1-7Ambient Lighting 1-7

Installation And Service Clearances 1-8Recommended Clearances 1-8

Important Notice To Users 1-8Minimum Clearances 1-10

Important Notice To Users 1-10Minimum Clearances 1-10

Exterior Wall 1-12Standard Collar 1-12Standard Collar With Advert Light 1-12

Service Access Panels 1-13

Hole In The Wall 1-14Installation Categories 1-14Installing Through A Glass Wall 1-14

Replacing 5088 With Modifications To Hole In Wall 1-15Plinth Requirements 1-15

Page 20: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPhysical Requirements

Replacing 5688 With No Modifications To Hole In Wall 1-16Plinth Requirements 1-16

Installing Through A New Hole 1-17Plinth Requirements 1-17

Sealing The Hole In The Wall Against Cold And Water 1-18

Requirements For The Floor 1-19Support Plinth 1-19

Mandatory Modifications To Plinth Or Floor 1-21Concrete Plinth 1-21Adjustable Plinth 1-21ATM Installed Directly On To The Floor 1-21Floor Loading 1-22Security Bolts 1-23Floor Covering 1-23

Infill Panel Dimensions 1-24Infill Panel (5088) 1-24Infill Panel (5688) 1-24

Internal Space Constraint For Fitting A Third Party Video Camera 1-25

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 21: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1

-1

Package DimensionsPhysical Requirements1

Package Dimensions 1

The dimensions of a packaged 5887 ATM are shown below.

1676 mm(65.98 in.)

1410 mm(55.51 in.)

900 mm(35.43 in.)

Page 22: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsPackage Dimensions

Manoeuvring The ATM Into Position 1

Ensure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM in an area with sufficient access and then move it to the installation site. Also ensure that any corridors can support the weight of the ATM.

The following table shows the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate an ATM on its axis.

Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the base of the ATM or packaging.

Note 2: A surrounding clearance of 6 mm (0.25 in.) has been allowed in the figures.

Unpackaged ATM Packaged ATM

without cheque acceptor

with cheque acceptor

All variants

A Doorway or straight corridor

667 mm (26.3 in.)

702 mm (27.64 in.)

912 mm (35.9 in.)

B Corridor with corner

868 mm (34.2 in.)

893 mm (35.16 in.)

1147 mm (45.2 in.)

C Rotation about centre

1302 mm (51.3 in.)

1320 mm (51.97 in.)

1685 mm (66.3 in.)

A B

B

C

1-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 23: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

ATM Dimensions 1

The following illustrations show dimensions for ATMs configured with CEN Grade III, CEN Grade IV LGAI and UL enclosures.

Note: Cables enter the ATM through the hole in the base of the ATM security enclosure. The location of the hole is shown in the illustration “Support Plinth” (see page 1-19).

Before Collar Has Been Fitted 1

The dimensions in the illustration below show the ATM before a collar has been fitted.

Note: For UL security enclosures, this dimension is 835.0 mm (32.87 in.). For CEN security enclosures, this dimension is 868.0 mm (34.17 in.).

805.5 mm(31.71 in.)

55.0 mm(2.17 in.)

4.8 mm(0.19 in.)

1357.0 mm(53.43 in.)

511.0 mm(20.12 in.)

640.0 mm(25.20 in.)

640.0 mm(25.20 in.)

600.0 mm(23.62 in.)

15.0 mm(0.59 in.)

800.0 mm(31.50 in.)

1105.0 mm(43.50 in.)

237.4 mm(9.35 in.)

515.6 mm(20.30 in.) 30.0 mm

(1.18 in.)

70.0 mm(2.76 in.)

See Note

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-3

Page 24: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Standard Collar 1

The dimensions in the illustration below show the ATM with a standard collar fitted.

Standard Collar With Advert Light 1

The dimensions in the illustration below show the ATM with a standard collar with advert light fitted.

37.5 mm(1.48 in.)

1175.3 mm(46.27 in.)

715.0 mm(28.15 in.)

464.9 mm(18.30 in.)

209.4 mm(8.24 in.)

37.5 mm(1.48 in.)

1338.3 mm(52.69 in.)

715.0 mm(28.15 in.)

209.4 mm(8.24 in.)

464.9 mm(18.30 in.)

1-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 25: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Severe Environment 1

The dimensions in the illustration below show the ATM with the severe environment option fitted.

Cheque Acceptor 1

The dimensions in the illustration below show the ATM with a cheque acceptor fitted.

314.0 mm(12.36 in.)

82.2 mm(3.24 in.)

248.0 mm(9.76 in.)

188.1 mm(7.41 in.)

228.0 mm(17.80 in.)

50.0 mm(1.97 in.)

800.0 mm(31.50 in.)

690.0 mm(27.17 in.)

35.5 mm(1.40 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-5

Page 26: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Height And Depth To Main Facia Items 1

The following illustration shows the height and depth to the main facia items located on the 5887 Drive-Up facia. The height dimensions from road level are based on the ATM being installed at the optimum height, given in the “Hole In The Wall” section later in this chapter.

SS

ReceiptAudioJack Plug

Speaker

MI K LJHE

1207.8 mm(47.55 in.)

882.8 mm(34.76 in.)

1207.0 mm(47.52 in.)

882.0 mm(34.72 in.)

1211.0 mm(47.68 in.)

886.0 mm(34.88 in.)

1023.6 mm(40.30 in.)

698.6 mm(27.50 in.)

1294.5 mm(50.96 in.)

969.5 mm(38.17 in.)

1108.4 mm(43.64 in.)

783.4 mm(30.84 in.)

1363.5 mm(53.68 in.)

1038.5 mm(40.89 in.)

Height (from Road Level)

Road Level

Plinth

Height (from Base of Terminal)

Depth (from front of Collar)

157.0 mm(6.18 in.)

105.0 mm(4.13 in.)

178.0 mm(7.01 in.)

138.0 mm(5.43 in.)

87.0 mm(3.43 in.)

130.0 mm(5.12 in.)

116.0 mm(4.57 in.)

CardReader

Motorised

CardReader

Dip

CameraWindow

Cash Exitor

Entry

A B E F IJ

HG LK M

15.0 mm(0.59 in.)

No. 5 Key

F

930.0 mm(36.61 in.)

605.0 mm(23.82 in.)

A

Statement

1317.7 mm(51.88 in.)

992.7 mm(39.08 in.)

151.0 mm(5.94 in.)

B

1171.7 mm(46.13 in.)

846.7 mm(33.33 in.)

Display

150.5 mm(5.93 in.)

5JKL

C

1123.0 mm(44.21 in.)

798.0 mm(31.42 in.)

1090.0 mm(42.91 in.)

765.0 mm(30.12 in.)

2ndFDK

1stFDK

D

120.0 mm(4.72 in.)

115.0 mm(4.53 in.)

C D

G

ChequeEntry

694.1 mm(27.33 in.)

106.8 mm(4.20 in.)

1019.1 mm(40.12 in.)

1-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 27: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Topmost Viewable Facia Item 1

The following illustration shows the projected angle from the front of the standard collar to the topmost viewable facia item.

Ambient Lighting 1

If the ATM is fitted with a video camera it is strongly recommended that there is a minimum of 200 LUX lighting at floor level within the area illustrated below. This lighting level conforms to:

● Australian Standard for Automatic Teller Machines (1990) ● Lighting for Automated Teller Machines as prepared by

Illuminating Engineering Society of North America (1997).

Note: A minimum of 200 LUX is recommended for task lighting.

Statement45

1000 mm(39.4 in.)

1500 mm(59.1 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-7

Page 28: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation And Service Clearances

Installation And Service Clearances 1

Recommended Clearances 1

The following illustration shows the recommended areas required for installing and servicing the ATM.

Note: If the ATM is replacing a 5088 installation, the building or kiosk may need rework or replacement, as the clearance area of the new ATM is predominantly to the rear.

Important Notice To Users 1

If it is likely that the terminal might be fitted with new modules as they become available, for example, upgrading the terminal with a cheque acceptor kit, you must use the recommended clearances.

1-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 29: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation And Service Clearances

Recommended Clearances

Note 1: The currency dispenser or cash acceptor can be serviced without fully extending its slides, giving a dimension of 786 mm (30.9 in.) as shown. This can be achieved by pulling the slides until the nose of the module is out of the security enclosure.

Note 2: For terminals fitted with a cheque acceptor, this dimension is 411 mm (16.18 in.).

Note 3: For UL security enclosures, this dimension is 160 mm (6.3 in.). For CEN security enclosures, this dimension is 260 mm (10.2 in.).

Note 4: Refer to the next section “Hole In The Wall” for the height of the plinth.

SeeNote 4

461 mm(18.1 in.)

See Note 2See

Note 3

1562 mm(61.4 in.)

786 mm(30.9 in.)Minimum

See Note 1

461 mm(18.1 in.)

1953 mm(76.9 in.)

Plinth

Currency Dispenseror

Cash Acceptor

2009 mm(79.1 in.)

1000 mm(39.4 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-9

Page 30: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation And Service Clearances

Minimum Clearances 1

The following illustration shows the minimum areas required for installing and servicing the ATM. Note that installing the ATM in the minimum servicing footprint may increase the servicing time for the unit.

Minimum clearance is achieved by installing the ATM in either side or rear clearance areas, as shown in the following illustration.

Important Notice To Users 1

If it is likely that the terminal might be fitted with new modules as they become available, for example, upgrading the terminal with a cheque acceptor kit, you must use the recommended clearances.

Minimum Clearances 1

SeeNote 4

152 mm(6.0 in.)

890 mm(35.0 in.)

See Note 2

1112 mm(43.8 in.)

See Note 3

786 mm(30.9 in.)Minimum

See Note 1

2009 mm(79.1 in.)

2231 mm(87.8 in.)

1793 mm(70.6 in.)

Plinth

See Note 5

110 mm(4.3 in.)

Severe EnvironmentAir Intake

Currency Dispenseror

Cash Acceptor

98 mm(3.9 in.)

1222 mm(48.1 in.)

SideClearance

RearClearance

1000 mm(39.4 in.)

1-10 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 31: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation And Service Clearances

Note 1: The currency dispenser or cash acceptor can be serviced without fully extending its slides, giving a dimension of 786 mm (30.9 in.) as shown. This can be achieved by pulling the slides until the nose of the module is out of the security enclosure.

Note 2: For terminals ordered with a cheque acceptor configured, this dimension is 940 mm (37.0 in.). The dimensions, 98 mm (3.9 in.) and 152 mm (6.0 in.), at either side of the terminal remain the same.

Note 3: For terminals ordered with a cheque acceptor configured, this dimension is 1162 mm (45.7 in.). The dimensions, 98 mm (3.9 in.) and 152 mm (6.0 in.), at either side of the terminal remain the same.

Note 4: Refer to the next section “Hole In The Wall” for the height of the plinth.

Note 5: If your ATM is installed within the minimum height clearance of 1793 mm (70.6 in.) the ceiling will restrict the full opening of the top-box. If you want the top-box to have a clearance above the top-box when fully open, refer to the recommended clearance.

Note 6: When the ATM is installed within the minimum service clearance, the 80 Column printer must be removed to service the keyboard and shutter areas.

Note 7: Your ATM may be fitted with the severe environment option, which is shown in the illustration (see ATM Dimensions section for more information). When severe environment is configured, the 80 Column printer must be removed to service the module from the rear.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-11

Page 32: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation And Service Clearances

Exterior Wall 1

The following illustrations show the minimum clear wall area required around the collar (facia surround) for installation and servicing.

Standard Collar 1

Note: A standard collar is configured when you order 5887 Drive-Up and feature 770 with 240.

Standard Collar With Advert Light 1

Note: A standard collar with advert light is configured when you order 5887 Drive-Up and feature 770 with 241.

30 mm(1.2 in.)

30 mm(1.2 in.)

10 mm(0.4 in.)

45 mm(1.8 in.)

30 mm(1.2 in.)

30 mm(1.2 in.)

45 mm(1.8 in.)

45 mm(1.8 in.)

1-12 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 33: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsService Access Panels

Service Access Panels 1

For installations where there is enough room to stand at the right-hand side of the sleeve (when viewing the ATM from the rear) there is an access panel on the top-box, as shown below. The panel can be removed to allow easier access to the keyboard and shutter areas.

Note: This access panel is not accessible if severe environment is fitted.

There is an additional panel on the right-hand side, which is only accessible if the ATM is installed through a thin wall, 80 mm (3.15 in.) or less.

There is one access panel on the left-hand side, as shown below, which is only accessible if the ATM is installed through a thin wall, 80 mm (3.15 in.) or less.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-13

Page 34: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsHole In The Wall

Hole In The Wall 1

The 5887 Drive-Up can be installed through an existing NCR 5088 or 5688 hole in the wall with minimal rework required depending on the ATM being replaced, wall thickness and the local cardholder access legislation.

Customised collars or surrounds made by the owning organisation may need rework or replacement due to the following installation requirements.

Installation Categories 1

The physical installation of 5887 Drive-Up is divided into three different categories.

1 An installation where a 5887 Drive-Up replaces a 5088. The hole in the wall must be modified and the plinth must be replaced with a new one to position the 5887 Drive-Up keyboard at the optimum height. See page 1-15.

2 An installation where a 5887 Drive-Up replaces a 5688 and where no modification has been made to the hole in the wall. The existing plinth must be replaced with a new one to position the 5887 Drive-Up keyboard at the optimum height. See page 1-16.

Note: The location of the cable access hole in the base of the ATM will change. Refer to the section “Requirements For The Floor” for more details.

3 A new installation of a 5887 Drive-Up at the optimum height. See page 1-17.

For categories 1 and 2, an infill panel is required to accommodate the larger hole used by the previous 5088 or 5688 installation.

Installing Through A Glass Wall 1

If you are installing your ATM through a glass wall you may require a suitable glass support (normally a steel collar) to sit between the ATM collar and the glass. The requirement for this support should be determined by the architect. If required, any such support should be sourced locally.

1-14 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 35: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsReplacing 5088 With Modifications To Hole In Wall

Replacing 5088 With Modifications To Hole In Wall 1

It is the responsibility of the owning institution to ensure that the heights from the road level to the facia items comply with any local regulations.

Note 1: A standard or advert collar is required at installation.

Note 2: The existing plinth must be replaced with a new one.

Note 3: An infill panel is required. For information on the infill panel, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing the infill panel, refer to chapter 8.

Plinth Requirements 1

Refer to page 1-19 for plinth requirements.

152.0 mm(5.98 in.)

Curb Set-back

618.0 mm(24.33 in.)

930.0 mm(36.61 in.)

165.0 mm(6.50 in.)

Maximum WallThickness

792.3 mm(31.19 in.)

Plinth

Remove Wall Section

Road Level

325.0 mm(12.80 in.)

View from Inside Building

ATM Base

35.0 mm

(1.38 in.)

643.0 mm(25.31 in.)

Optimum Heightof No.5 Key

Hole in Wall

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-15

Page 36: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsReplacing 5688 With No Modifications To Hole In Wall

Replacing 5688 With No Modifications To Hole In Wall 1

It is the responsibility of the owning institution to ensure that the heights from the road level to the facia items comply with any local regulations.

Note 1: A standard or advert collar is required at installation.

Note 2: The existing plinth must be replaced with a new one.

Note 3: An infill panel is required. For information on the infill panel, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing the infill panel, refer to chapter 8

Plinth Requirements 1

Refer to page 1-19 for plinth requirements.

152.0 mm(5.98 in.)

Curb Set-back

724.0 mm(28.50 in.)

930.0 mm(36.61 in.)

165.0 mm(6.50 in.)

Maximum WallThickness

825.0 mm(32.48 in.)

Plinth

624.0 mm(24.57 in.) Hole in WallOptimum Height

of No.5 Key

Road Level

325.0 mm(12.80 in.)

View from Inside Building

ATM Base

35.0 mm

(1.38 in.)

1-16 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 37: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstalling Through A New Hole

Installing Through A New Hole 1

It is the responsibility of the owning institution to ensure that the heights from the road level to the facia items comply with any local regulations.

Note: A standard or advert collar is required at installation.

Plinth Requirements 1

Refer to page 1-19 for plinth requirements.

152.0 mm(5.98 in.)

Curb Set-back

610.0 mm(24.02 in.)

View from Inside Building

930.0 mm(36.61 in.)

165.0 mm(6.50 in.)

Maximum WallThickness

833.0 mm(32.80 in.)

Plinth

602.0 mm(23.70 in.)

ATM Base

Hole in WallOptimum Heightof No.5 Key

Road Level

325.0 mm(12.80 in.)

35.0 mm

(1.38 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-17

Page 38: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsSealing The Hole In The Wall Against Cold And Water

Sealing The Hole In The Wall Against Cold And Water 1

To ensure that the temperature around the ATM is maintained during cold weather, it is important that the wall opening is prepared correctly. Any cavity in the wall should not extend into the wall opening, but sealed to provide a flush surface. The gap between the ATM sleeve and the wall opening should be left clear to allow air at room temperature to circulate.

To enable a good weather seal to be made between the wall and the ATM facia, a 25 mm (1 in.) wide smooth surface is required around the periphery of the wall opening.

Seal any cavity

Do not block air gaps

1-18 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 39: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsRequirements For The Floor

Requirements For The Floor 1

Support Plinth 1

The following illustrations show a plan of the base of the ATM (viewed from above) and its relationship with the exterior wall. If a plinth is used it should be no smaller than the base of the ATM and it must be constructed of a material, and in such a way, that it is capable of supporting the weight of the ATM (see page 1-22).

The definition of a plinth is a platform on to which the ATM is bolted. This plinth enables the ATM to be installed at the required height through the wall.

Detail of hole A (UL Safe)

30.0 mm(1.18 in.)

15.0 mm(0.59 in.)

25.0 mm(0.98 in.)

Detail of hole A (CEN Safe) Detail of hole B (CEN Safe only)

x

28.0 mm(1.10 in.)

60.0 mm(2.36 in.)

25.0 mm(0.98 in.)

Counterbore Deep

30.0 mm(1.18 in.)

15.0 mm(0.59 in.)

x45 mm(1.77 in.)

25.0 mm(0.98 in.)

28.0 mm(1.10 in.)

Counterbore Deep

800.0 mm

(31.50 in.)

Front of Wall

Cheque

Acceptor

Side-box

501.5 mm

(19.74 in.)

359.0 mm

(14.13 in.)

See Note 1

148.5 mm

(5.85 in.)

56.0 mm

(2.20 in.)

130.0 mm

(5.12 in.)

190.5 mm

(7.50 in.)

See Note 2

50.0 mm

(1.97 in.)

70.5 mm

(2.78 in.)178.0 mm

(7.01 in.)

C

AA

B

AA

D

129.5 mm

(5.10 in.)

106.5 mm

(4.19 in.)

35.0 mm

(1.38 in.)

125.0 mm

(4.92 in.)

235.0 mm

(9.25 in.)

640.0 mm

(25.20 in.)

See Note 2

Hole in Wall

165.0 mm

(6.50 in.)

Max Wall

Thickness

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-19

Page 40: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsRequirements For The Floor

Note 1: When an infill panel is required, this dimension is 347 mm (13.66 in.). For information on infill panels, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing infill panels, refer to chapter 8.

Note 2: For terminals fitted with a cheque acceptor, these dimensions are increased by 50 mm (1.97 in.).

Note 3: The hole, marked with a ‘B’, enables a security alarm sensor to be fitted.

Note 4: The boundary, marked with a ‘C’, shows the cable access hole for all cables.

Note 5: The dotted boundary, marked with a ‘D’, shows where the cable access hole would be on a 5688 being replaced with 5887 Drive-Up.

1-20 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 41: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsMandatory Modifications To Plinth Or Floor

Mandatory Modifications To Plinth Or Floor 1

The following modifications must be made to the plinth:

Concrete Plinth 1

If a concrete plinth is used at installation, a section of the plinth should be cut-out to allow the fitting of the cables which enter the base of the ATM.

The following illustration shows the size of cut-out required for all security enclosure options.

Adjustable Plinth 1

If an adjustable plinth is used, holes should be drilled through the plinth, to allow the fitting of the cables which enter the base of the ATM.

ATM Installed Directly On To The Floor 1

If the ATM is installed directly on to the floor, without a plinth, the cabling must be routed through a channel in the floor. The channel must be large enough to allow the cabling to be routed along the floor and under the ATM.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-21

Page 42: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsMandatory Modifications To Plinth Or Floor

Note: For terminals fitted with a cheque acceptor, these dimensions are increased by 50 mm (1.97 in.).

Floor Loading 1

The ATM must be installed on a floor capable of supporting the maximum weight. Only the maximum weight should be considered as additional options may be added after installation.

CEN Grade III or CEN IV LGAI Security enclosures:

● Maximum weight: 840 kg (1852.2 lb.)● Floor loading: 2121.2 kg/m2 (434.4 lb./ft2).

Standard Security enclosure (UL):

● Maximum weight: 662 kg (1459.7 lb.)● Floor loading: 1671.7 kg/m2 (342.4 lb./ft2).

186 mm

(7.32 in.)

130.0 mm

(5.12 in.)

240.5 mm

(9.47 in.)

See Note

2.5 mm

(0.10 in.)

35.0 mm

(1.38 in.)

Hole in Wall

50.8 mm

(2.00 in.)

800.0 mm

(31.50 in.)

640.0 mm

(25.20 in.)

See Note

Cheque

Acceptor

Side-box

1-22 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 43: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsMandatory Modifications To Plinth Or Floor

Security Bolts 1

The ATM should be bolted to the floor or plinth, through the ‘A’ holes (see page 1-19), using four bolts with anchor washers. The floor or plinth must be capable of withstanding the loading imposed by the anchor points for the bolts. The bolts and anchors must be supplied by the owning organisation.

The following is the minimum specification for bolts to secure the ATM to a plinth or a stone/concrete floor, through the ‘A’ holes:

● CEN Grade III or CEN IV LGAI Security enclosures:16 mm (0.63 in.) diameter x 120 mm (4.72 in.) minimum length.

Note 1: The anchor washer must be a minimum of 3 mm (0.12 in.) thick with an outer diameter of 40 mm (1.57 in.) and an inner diameter of 18 mm (0.71 in.).

Note 2: The centre bolt hole ‘B’ in the floor is counterbored to a larger diameter than the other four. This enables a security alarm sensor to be fitted through the hole.

● Standard Security enclosures (UL): 16 mm (0.63 in.) diameter x 100 mm (3.94 in.) minimum length.

Floor Covering 1

An antistatic floor covering should be used and must be of a type that will not generate dust or fluff.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-23

Page 44: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInfill Panel Dimensions

Infill Panel Dimensions 1

Customised infill panels, made by owning organisations, should use the following dimensions as a guide:

Infill Panel (5088) 1

For an infill panel for the 5088 replacement, use the following dimensions:

Infill Panel (5688) 1

For an infill panel for the 5688 replacement, use the following dimensions:

620.0 mm(24.41 in.)

70.0 mm(2.76 in.)

12.0 mm(0.47 in.)

90.0 mm(3.54 in.)

600.0 mm(23.62 in.)

800.0 mm(31.50 in.)

995.0 mm(39.17 in.)

70.0 mm(2.76 in.)

12.0 mm(0.47 in.)

150.0 mm(5.91 in.)

920.0 mm(36.22 in.)

995.0 mm(39.17 in.)

600.0 mm(23.62 in.)

620.0 mm(24.41 in.)

1-24 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 45: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInternal Space Constraint For Fitting A Third Party Video Camera

Internal Space Constraint For Fitting A Third Party Video Camera 1

The ATM can be ordered with a video camera in either PAL or NTSC format. However, if a camera is not configured and a third party video camera is to be installed, there is a space constraint to consider. The location of the video camera is directly behind the camera window. The following dimensions should be calculated from the centre point on the window, as shown below.

Note 1: The depth constraint, from the rear of the camera window, is 130 mm (5.12 in.).

18.0 mm(0.71 in.)

36.0 mm(1.42 in.)

44.0 mm(1.73 in.)

44.0 mm(1.73 in.)

Camera Window

Camera Position

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 1-25

Page 46: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInternal Space Constraint For Fitting A Third Party Video Camera

1-26 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 47: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsElectrical Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 2

Electrical Requirements

Power Quality Distribution And Grounding Requirements 2-1AC Power Requirements 2-1Input Voltage Setting 2-1Power Consumption 2-1

Idle Mode 2-1Under Transaction 2-1

Power Cable 2-2Grounding Requirements 2-2EMI Susceptibility 2-3EMI Emission 2-3

Communications Requirements 2-4High Order Communications Cable 2-4

High Order Communications Standard Cable (RS-232) 2-4

Remote Device Cables 2-6RS-232 Cable (25 pin) 2-6Remote Status Monitor 2-8Alarm Interface Cable 2-10Remote Relay Cable 2-12Ethernet Standard Cable 2-13Integrated Services Digital Network (ISDN)

Standard Cable 2-14Internal Cables 2-15

Page 48: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsElectrical Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 49: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2

-1

Power Quality Distribution And Grounding RequirementsElectrical Requirements2

Power Quality Distribution And Grounding Requirements 2

Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in Attachments A, may be required to ensure proper operation of the equipment.

AC Power Requirements 2

The maximum current requirements at the stated input voltages are:

● 5.05A at 120V, or 9.1A with severe environment● 2.01A at 240V, or 4.2A with severe environment.

The maximum inrush current at the following input voltage is:

● 200A peak at 136V● 150A peak at 257V.

Note: If you are considering upgrading your ATM to include the cash acceptor, you should be aware that in the event of a power failure, there is the potential for customers cash to be retained in this unit, and for details of the transaction to be lost. For this reason NCR do not recommend running a 5887 with cash acceptor without an Uninterruptible Power Supply (UPS).

Input Voltage Setting 2

The ATM can operate from the following input mains voltages:

● 90V to 136V at 50/60Hz● 180V to 264V at 50/60Hz.

Power Consumption 2

A power consumption rate for your ATM can be calculated from the following information:

Idle Mode 2

● 307 Watts at 120V● 177 Watts at 240V.

Note: Power consumption is dependent on the configuration of your ATM.

Under Transaction 2

● 606 Watts at 120V, or 1092 Watts with severe environment● 482 Watts at 240V, or 1008 Watts with severe environment.

Page 50: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsPower Quality Distribution And Grounding Requirements

Note: Power consumption is dependent on the transaction rate of your ATM.

Power Cable 2

The ATM is supplied either as a 120V or a 220-240V unit. 120V ATMs are supplied with a power cable fitted with a NEMA type 5-15P power source connector. 220-240V ATMs are supplied with an unterminated power cable. Information about suitable power connectors is supplied with the accessories. Power connectors must be wired as shown below.

The power cable supplied is 3 metres (9 ft. 9.00 in.) in length. If it is necessary to increase this length to meet site requirements, then the extension must satisfy local or country regulations.

Note 1: If the ATM being installed is replacing a 5088 installation, it may be necessary to either lengthen the cable or re-position the electrical sockets because the cable access hole is in the security enclosure and toward the rear of the enclosure.

Note 2: If the ATM being installed is replacing a 5688 installation, it may be necessary to either lengthen the cable or re-position the electrical sockets because the cable access hole is on the other side.

Warning This equipment must be earthed.

Note: The annotations within brackets are included to comply with United Kingdom legislation and refer to the markings on United Kingdom three pin plugs.

Grounding Requirements 2

The ATM operates from a single phase, 3 wire supply; live, neutral and ground. The power requirements of this unit will normally permit it to operate within existing wiring configurations and from existing branch mains outlets providing:

1 Where this supply is provided from a general purpose distribution panel, then the other branch circuits from this panel must not be used to support heavy inductive loads such as air conditioners, elevators, microwave ovens, and so on. Nor may such equipment be operated on the same branch circuit as the ATM.

Live - Brown1

2

3

(L or Red)

(N or Black)

(E or Green/Yellow)

Neutral - Blue

Ground - Yellow/Green

2-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 51: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsPower Quality Distribution And Grounding Requirements

2 If using distribution panels, all branch circuit grounding conductors must be connected to an insulated terminal strip in the distribution panel. The grounding conductor from the distribution panel to the building ground point must be at least equal in size to the power conductor necessary to supply the NCR system.

Note: The building ground point can affect data integrity. For additional information refer to the ‘Data Line Transient Protection’ section of Attachment A.

EMI Susceptibility 2

The ATM meets EN 55024 (1998) “ITE Immunity Standard”.

EMI Emission 2

The ATM meets FCC CFR 47 Prt 15 Class A and EN 55022 (1998) Class A requirements for radiated and conducted emission.

The ATM meets EN61000-3-2 (latest revision) Mains Harmonics (Class A) and EN61000-3-3 (latest revision) Mains Flicker requirements for conducted emission.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-3

Page 52: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Communications Requirements 2

Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in Attachment A, may be required to ensure proper operation of the equipment.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with NCR specifications and requirements and with all national, state or local telephone and telegraph regulations and laws.

High Order Communications Cable 2

The type of high order communications cable required depends upon the communications system to be used.

Note: External Communications cables are not supplied with the ATM. If these cables are required, it is the customer’s responsibility to have them installed. The specification for this cable is supplied in the following section. When producing cables allow for 1 metre (3.3 feet) of cable within the ATM.

High Order Communications Standard Cable (RS-232) 2

The standard high order communications system supports most common bit and byte oriented disciplines (synchronous and asynchronous) with an RS-232 interface.

The interconnecting cable to the remote modem should not exceed 15.24 metres (50 feet) in length, and must conform to the specification and wiring given below.

2-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 53: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 550mm (21.65 in.) from the 25 way connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

1, 2 6 5

CHASSIS GND1

TD.V2

RD.V3

RQS.V

TSET.V

4

15

RFS.V

RSET.V

5

17

DSR.V

WCA.V

6

18

SIG.GND

DTR.V

EXT SET.V

7

20

24

RLSD.V

CI.V

WIN.V

8

22

25

1. Connector, 25 way (NCR part no. 006-0005897).2. Terminal wire, male (NCR part no. 009-0002642).3. Cable, multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).5. Shell hood (NCR part no. 006-1500038).6. Screw retainer (NCR part no. 601-0101584).

3 4

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-5

Page 54: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Remote Device Cables 2

The specifications for these external cables are supplied below.

RS-232 Cable (25 pin) 2

The ATM can have up to two RS-232 (25 pin) outlets which can be configured to provide an interface for one of two options:

● Remote camera● Remote card access device.

For both options the cable is limited in length to 15.24 metres (50 feet) and must conform to the specification and wiring given below.

Note: The modemless cable adapter is supplied with RS-232 interface feature kits. This adapter performs crossover and linking normally associated with modemless operation. If this linking is not required, the modemless cable adapter may be removed and the RS-232 Interface Cable connected directly to the ATM.

1. Connector, 25 way (NCR part no. 006-0005897).2. Terminal wire, male (NCR part no. 009-0002642).3. Cable, multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).

1500038

CHASSIS GND CHASSIS GNDTDRDRSLDCTS

DSRDTRSIGNAL GND

RTS

Modemless Cable Adapter RS232 Interface Cable

TDRDRTSCTSRSLDDSRDTRSIGNAL

1 112 223 338 845 554 486 6620 20207 77

1, 2 6 5 3 4

2-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 55: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 550mm (21.65 in.) from the 25 way connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

RS-232 Cable (9 pin)

The ATM has one RS-232 (9 pin) outlet. The cable for this outlet is limited in length to 15.24 metres (50 feet) and must conform to the specification and wiring given below.

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

1. Connector, 9 way (NCR part no. 006-0005897).2. Terminal wire, male (NCR part no. 009-0002642).3. Cable, multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).

1500038

DCD

DSR

RXDTXDDTRS-GND

RTSCTSRI

Shielding Shielding

1 12 23 34 45 56 67 78 89 9

1, 2 6 5 3 4

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-7

Page 56: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 550mm (21.65 in.) from the 9 way connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

Remote Status Monitor 2

The remote status monitor feature is supplied as a complete assembly and consists of a status indicator unit, 76.2 metres (250 feet) of cable and a connector.

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

2-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 57: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 550mm (21.65 in.) from the connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

If you are required to shorten the cable, proceed as follows:

1 Remove the cover from the remote status indicator unit.

2 Disconnect the four leads from the indicator, that is E1, E2, E3 and E4.

3 Cut the cable to the required length and strip the four wire ends.

4 Connect the wires to the correct ATMs.

5 Replace the status indicator cover.

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

Red

(Green) E1

(Red) E2

(White) E3

(Black) E4

Yellow

Green

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-9

Page 58: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Alarm Interface Cable 2

The ATM may optionally be configured to provide an alarm interface which enables the ATM to be connected to an external local alarm system. The interface may take the form of one of two options; a basic alarm system or an enhanced alarm system.

A stabilised, non interruptible, power supply must be provided through the external alarm system. The alarm interface cable wiring must conform to the following specification:

● 12V +- 2V dc● 200mA maximum● Ripple, 5% maximum.

At a point 550mm (21.65 in.) from the 25 way connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

1. Connector, 25 Way (NCR part no. 006-0005896)2. Terminal, wire, female (NCR part no. 009-0002640)3. Cable, multiconductor (determined by the alarm installed).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).

1500038

1,2 5 3 46

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

2-10 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 59: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Basic alarm interface cable wiring

Enhanced and High Security alarm interface cable wiring

CHASSIS GND

SILENT ALARM N.O. *

DOOR ALARM N.C.

VIBRATION/HEAT N.O.

SILENT ALARM COMMON *

SILENT ALARM N.C. *

VIBRATION/HEAT COMMON

VIBRATION/HEAT N.C.

DOOR ALARM N.O.

DOOR ALARM COMMON

+12V (POSITIVE)

+12V (NEGATIVE)

1

9

21

7

19

10

22

8

20

12

23

25* Optional

CHASSIS GND

DOOR ALARM N.O.

TAMPER ALARM N.C.

TEST TRANSMITTER A

SILENT ALARM COMMON *

TAMPER ALARM N.O.

+12V (POSITIVE)

1

6

12

21

3

9

7

16

22

5

10

20

8

18

23

19

25

TEST TRANSMITTER B

DOOR ALARM N.C.

TAMPER ALARM COMMON

DOOR ALARM COMMON

.

SILENT ALARM N.O. *

COMPOSITE ATTACK N.C.

COMPOSITE ATTACK N.O.

SILENT ALARM N.C. *

+12V (NEGATIVE)

* Optional

COMPOSITE ATTACK COMMON

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-11

Page 60: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Remote Relay Cable 2

The remote relay provides a pair of open contacts, rated at 28 volts per ampere for both ac and dc supplies, which can be closed to activate a remote device. The interconnecting cable to a remote device must conform to the following specification and wiring:

At a point 550mm (21.65 in.) from the 2 way connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

1, 2

1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).2. Terminal wire, male (NCR part no. 007-2009663).3. Cable, multiconductor (NCR part no. 006-5800006).4. Connector (determined by remote device).

3

1RL1

2RL2

4

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

2-12 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 61: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Ethernet Standard Cable 2

The ethernet standard cable must be category 5 compliant and not exceed 100 m (328 ft) in length. The cable must conform to the specification and wiring given below.

At a point 550mm (21.65 in.) from the 8 pin connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

Pin 1Pin 8

TXDP1

TXDN2

RXDP3

N/C4

N/C5

RXDN6

N/C7

N/C8

1. Connector, 8 pin (NCR part no. 006-8800237).2. Cable, category 5 shielded (NCR part no. 006-8800387).3. Connector (determined by remote device).

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-13

Page 62: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Integrated Services Digital Network (ISDN) Standard Cable2

The ISDN standard cable must be category 5 compliant and not exceed 100 m (328 ft) in length. The cable must conform to the specification and wiring given below.

At a point 550mm (21.65 in.) from the 8 pin connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

Pin 1Pin 8

N/C1

N/C2

TXDP3

RXDP4

RXDN5

TXDN6

N/C7

N/C8

1. Connector, 8 pin (NCR part no. 006-8800237).2. Cable, category 5 shielded (NCR part no. 006-8800387).3. Connector (determined by remote device).

20.0 mm(0.79 in.)

550.0 mm(21.65 in.)

2-14 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 63: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Internal Cables 2

The ATM can be ordered with the internal cables (between the PC core and the I/O panel) configured. However, if the cables are not configured, it is recommended that you order the NCR kit 5887-K678-V001. This kit includes the following cables:

● High Order Communications Standard Cable (RS-232)

● Ethernet/Integrated Services Digital Network (ISDN) Standard Cable

● RS-232 Cable● Analogue Modem Standard Cable.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 2-15

Page 64: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

2-16 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 65: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsEnvironmental Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 3

Environmental Requirements

Environmental Requirements 3-1Temperature And Humidity 3-1Barometric Pressure 3-2Electromagnetic Compatibility (EMC) And Safety 3-3

EMC Directives 3-3Immunity Standards 3-3

Acoustics 3-3Heat Dissipation 3-3Air Flow 3-3Temperature Rise 3-3

Page 66: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsEnvironmental Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 67: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 3

-1

Environmental RequirementsEnvironmental Requirements3

Environmental Requirements 3

For the ATM to function correctly the site at which it is to be installed should meet the following environmental requirements.

Temperature And Humidity 3

The ATM will operate over a range of temperature and humidity. However, continuous operating at or near the range limits or in a location where the temperature and humidity change beyond the specification, should be avoided. The temperature and humidity ranges are as follows:

Normal operating range (interior to wall environment):

● Temperature: 10oC to 40oC (50oF to 104oF) ● Temperature change rate: 10oC/hour (18oF/hour) ● Relative humidity: 20% to 80% ● Relative humidity change rate: 10%/hour ● Dew point temperature restriction: 26oC (79oF) maximum.

Note: The humidity inside the building is restricted to a maximum of 30% at an outside temperature of -35oC (-31oF) with a linear (straight line) relationship between temperature and humidity to a maximum humidity of 80%.

Normal operating range (exterior to wall environment):

● Temperature: -35oC to 50oC (-31oF to 122oF) ● Temperature change rate: 10oC/hour (18oF/hour) ● Relative humidity: 10% to 90% ● Relative humidity change rate: 10%/hour.

Storage range (up to three months):

● Temperature: -10oC to 50oC (14oF to 122oF) ● Temperature change rate: 15oC/hour (27oF/hour) ● Relative humidity: 10% to 90%

Transit range (up to one week):

● Temperature: -40oC to 60oC (-40oF to 140oF) ● Temperature change rate: 20oC/hour (36oF/hour) ● Relative humidity: 5% to 95%

Page 68: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Environmental RequirementsEnvironmental Requirements

Extreme power on range (up to one hour):

● Temperature: 0oC to 40oC (32oF to 104oF) ● Temperature change rate: 10oC/hour (18oF/hour) ● Relative humidity: 10% to 95%.

Barometric Pressure 3

Barometric pressure details are as follows:

● Operating and transit limits: 105kPa (15.2 lb. F/in.) ● Equivalent altitude: up to a maximum of

3000 metres (9842 feet).

The ATM will accommodate an external to internal pressure difference of up to 70 pascal (with the severe environment option fitted).

How to determine whether severe environment is required

The following equipment is required:

● a gauge which measures pressure with an appropriate scale (up to 100 pascals)

● a piece of tubing to fit the gauge● silicon sealant● suitable wall sealant.

The following procedure should be followed, before the hole in the wall is created:

1 Drill a hole through the exterior wall where the ATM’s facia is to be located. The diameter of the hole should be correct to accommodate the diameter of the tubing being used.

2 Insert the tubing through the hole so that the tube is located inside the building.

3 Use the sealant to make sure that there are no gaps between the tubing and the exterior wall.

4 Attach the gauge to the loose end of the tube (that is, on the inside of the building).

5 Take a note of the pressure reading.

6 Remove the tube and gauge, and seal the hole in the wall using a suitable sealant.

7 If the pressure gauge indicates a negative pressure differential, then NCR recommend that the ATM to be installed should have severe environment fitted.

3-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 69: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Environmental RequirementsEnvironmental Requirements

Electromagnetic Compatibility (EMC) And Safety 3

The ATM complies with the following standards and directives:

EMC Directives 3

● 89/336/EEC “EMC Directive”● 92/31/EEC “Amending EMC Directive”● 73/23/EEC “Low Voltage Directive”● 93/68/EEC “CE Marking Directive”.

The Harmonised EMC Standards are as follows:

● Radiated and Conducted:● EN 55022 (1998) Class A● FCC CFR 47 Part 15 Class A.

● Conducted (220V - 240V):● EN61000-3-2 (latest revision) Mains Harmonics (Class A)● EN61000-3-3 (latest revision) Mains Flicker.

Immunity Standards 3

● EN 55024 (1998) “ITE Immunity Standard”.

The Harmonised Safety Standard is as follows:

● EN 60950 “Safety of IT Equipment”.

Acoustics 3

The acoustics sound power does not exceed:

● 65 dB(A) idle● 68 dB(A) operating.

Heat Dissipation 3

The heat dissipation of the ATM is 1580kJ/hour (1500 BTU/hour) maximum.

Air Flow 3

The air flow through the ATM is rated at 0.1 m3/s (212 ft3/min.).

Temperature Rise 3

The temperature rise for air passing through the ATM is 3oC (5.4oF).

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 3-3

Page 70: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Environmental RequirementsEnvironmental Requirements

3-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 71: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsDecal Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 4

Decal Requirements

Decal Dimensions 4-1Card Orientation Window 4-2Card Acceptance Decal 4-2Clear Window 4-3Advert Light 4-3Entry/Exit Slot Decals 4-4

Page 72: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsDecal Requirements

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 73: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 4

-1

Decal DimensionsDecal Requirements4

Decal Dimensions 4

The following illustrations provide the specifications and locations for the decals which you may wish to fit to the front of your ATM.

Card

Cash

Receipt

Statement

CardOrientation

Advert Light

Page 74: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Card Orientation Window 4

If the window next to the Card Reader entry/exit slot is to be customised to indicate card orientation, the card/decal to be inserted into the window should be of the following dimensions.

The insert should be a maximum of 0.75 mm (0.029 in.) thick.

The decal should not be made of an absorbent material if the front of the ATM is likely to be subjected to rain.

Card Acceptance Decal 4

If a decal is required to advertise which cards can be used in the ATM, it should be positioned on the ATM sleeve, next to the facia. The decal can be any size (providing it fits onto the sleeve area).

54.0 mm(2.13 in.)

86.0 mm(3.39 in.)

R 3.0 mm (0.12 in.) Typical

4-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 75: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Clear Window 4

The front of the cheque acceptor blank moulding will have a large clear window. If an insert is to be made to go behind the window it should be of the following dimensions.

The insert should be a maximum of 0.8 mm (0.03 in.) thick. NCR recommend that the insert be made from one of the following materials:

● Polycarbonate● Polyester● Paper.

Note: Paper is not recommended if the front of the ATM is likely to be subjected to rain.

Advert Light 4

The following illustration shows dimensions for an advert light decal. These dimensions are based on a decal being applied to the flat inside area of the advert light panel.

169.0 mm(6.65 in.)

55.0 mm(2.17 in.)

R 1.0 mm (0.04 in.) Typical

575.0 mm(22.64 in.)

130.0 mm(5.12 in.)

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 4-3

Page 76: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Entry/Exit Slot Decals 4

The front of the ATM has recesses for decals to identify the entry and exit slots. The following are guidelines to the decal sizes and design, although financial institutions may wish to design their own. The decals should be a maximum of 0.5 mm thick and it is recommended that they be made from Textured Polycarbonate with 3M 467 High Performance MP adhesive.

Note: A combination of your application and screen graphics can be used as an alternative to indicate the cash/media exit slot.

STATEMENT

STATEMENT

CASH DISPENSE

CASH DEPOSIT

CHEQUE DEPOSIT

RECEIPT

CARD

52.0 mm(2.05 in.)

4.0 mm(0.16 in.)

MEI Area of Decalto be Transparent

18 point Arial Text

118.0 mm(4.65 in.)

12.0 mm(0.47 in.)

1.0 mm(0.04 in.)

59.0 mm(2.32 in.)

86.0 mm(3.39 in.)

R 2.0 mm(0.08 in.)

4-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 77: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Accessories And Planning Check List

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 5

Installation Accessories And Planning Check List

Installation Accessories 5-1

Planning Check List 5-2

Page 78: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Accessories And Planning Check List

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 79: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 5

-1

Installation AccessoriesInstallation Accessories And Planning Check List5

Installation Accessories 5

When installing your ATM it is recommended that you have the following items available:

● Pincers/claw hammer to remove staples/nails from around the air/sea pallet

● Small crosshead screwdriver● Pozi drive screwdriver● Small flat blade screwdriver● To fit fixing bolts: a 19 mm (3/4 in.) ring/open-ended

combination spanner and socket are required for a UL safe; a 27 mm (1 1/8 in.) socket with a maximum outside diameter of 33 mm (1 5/16 in.) is required for a CEN Grade III or CEN LGAI Security enclosure

● 7 mm (9/32 in.) ring/open-ended combination spanner or socket to fit the standard or advert facia light

● Lifting/moving device. Lifting trolleys must have a maximum toe plate length of 380 mm (14.96 in.) and a minimum toe plate width of 120 mm (4.72 in.).

● If you are using a pair of lifting trolleys to remove the ATM from its pallet, you will require: ● A 1410 mm (55.51 in.) x 400 mm (15.75 in.) x 65 mm (2.56 in.)

pallet extension board● Safety boards, with a minimum height of 65 mm (2.56 in.), to

support the ATM.● Packing to protect the exterior of the ATM while on a trolley.

Page 80: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installation Accessories And Planning Check ListPlanning Check List

Planning Check List 5

To assist you in preparing your site for the arrival of your ATM we provide here a check list of the various procedures that you should carry-out prior to the arrival of your ATM. The procedures given are listed in chronological order, starting with the procedure that you should do first.

Activity

Select site and make scaled floor plan

Ensure correct environmental conditions

Establish all contractor and vendor related schedules

Check communication line requirements

Plan application development

Check floor plan and make any alterations

Install additional electrical outlets (if required)

Prepare site for data communication

Arrange for designing and printing of overlays/ decals

Order technical publications

Order media supplies

Plan operator training (optional)

Ensure data comms. equipment is installed and tested

Ensure installation accessories are available

5-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 81: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Procedure

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 6

Installation Procedure

Introduction 6-1Installation Steps 6-1Site Preparation 6-1Tools Required For ATM Installation 6-1Moving The ATM 6-2

Page 82: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Procedure

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 83: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 6

-1

IntroductionInstallation Procedure6

Introduction 6

Installation Steps 6

The installation of the NCR Personas M Series 5887 Drive-Up ATM can be divided into several steps:

● Moving the ATM● Unpacking the ATM● Inspecting the ATM for damage● Removing the ATM from the pallet● Fitting the severe environment parts (if required)● Positioning the ATM through the hole in the wall● Fitting the infill panel to the wall (if required)● Fitting the collar● Sealing to the outside wall● Bolting the ATM to floor or plinth● Removing the internal packaging ● Connecting cables to the ATM● Configuring the ATM● Applying decals to the facia.These steps are described in detail in the chapters that follow.

Site Preparation 6

Before installing your ATM make sure that the installation site conforms to the specifications given in Chapter 1 to Chapter 5 of this publication.

Tools Required For ATM Installation 6

To install the ATM you will require a number of tools. These are listed in Chapter 5.

Page 84: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installation ProcedureIntroduction

Moving The ATM 6

The ATM will be mounted on a pallet and contained in a cardboard crate.

Move the ATM to its installation site using lifting trolleys. To reduce the chance of damaging the ATM, and the premises, the ATM should be moved with its packaging intact.

Details of the ATM dimensions, packaging dimensions and clearances required for moving the ATM in a confined space can be found in Chapter 1.

6-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 85: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPreparing The ATM For Installation

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 7

Preparing The ATM For Installation

Removing The External Packaging From The ATM 7-1Inspecting The ATM For Damage 7-1Installation Report Form 7-2

Opening The ATM 7-3How To Open The ATM 7-4How To Open The Cheque Acceptor Side-Box 7-5

How To Unlock And Lock A Standard Security Enclosure 7-6Keylocks 7-7Combination Locks 7-7Combination Lock And Separate Keylock 7-9

How To Unlock And Lock An Electronic Lock 7-13Unlocking 7-13Locking 7-14Emergency Opening Procedure 7-15

How To Unlock And Lock A Controlled Access Electronic Lock 7-16Unlocking the Master Lock 7-17Locking the Master Lock 7-19Unlocking the Sub-Lock 7-19Locking the Sub-Lock 7-20

Removing The ATM From Its Pallet 7-22

Page 86: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPreparing The ATM For Installation

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 87: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7

-1

Removing The External Packaging From The ATMPreparing The ATM For Installation7

Removing The External Packaging From The ATM 7

Before removing the external packaging, examine it for signs of damage which may have occurred during transit. Make a note of any external damage for inclusion in a damage report. See the next section for details on reporting damage.

When the ATM is approximately in its position for installation, remove the external packaging as follows:

1 Lever out the staples from around the base of the crate and then lift the crate from the pallet.

2 Remove the plastic cover.

3 Remove any kit packages.

4 Remove all pieces of tape from the exterior of the ATM.

Inspecting The ATM For Damage 7

After unpacking the ATM, inspect it for any signs of damage.

If the ATM is damaged a report should be made in accordance with the following procedures:

● Customers in the USA should refer to the Branch Practices manual and report the damage on: ● Marketing communications document

No. 73-130, file location 2-20-57● Marketing communications document

No. 71-273, file location 2-70-40● Other customers should use one of the following procedures:

● Customers who are required to arrange their insurance locally should have the claim processed locally. A separate report of damage should be made to Inventory Return Control, Dayton

● Customers who have insurance arranged by NCR Insurance Department, Dayton, must report the damage on Form F-2100 (Notice of Damage) to NCR Insurance Department and send a copy to Inventory Return Control.

The addresses for NCR Insurance and Inventory Return Control are:

● Risk Management and Insurance, NCR Corporation, Dayton, Ohio 45479, USA.

● Inventory Return Control, International Field Engineering Support, NCR Corporation, Dayton, Ohio 45479, USA.

Page 88: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationRemoving The External Packaging From The ATM

Installation Report Form 7

The Installation Report Form delivered with the ATM should always be completed and returned. Make sure that you report any problems in the following areas:

● Malfunction of the ATM or any of its devices● Internal or external defects arising as a result of handling or

transit damage● Missing or damaged accessories. All the accessories are fitted at

the appropriate feature inside the ATM.

7-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 89: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationOpening The ATM

Opening The ATM 7

Before you open the ATM, remove the tape from the security enclosure door, handles, dials and top-box.

The key to open the top-box is shipped inside the document bag, which is taped to the ATM.

The keys to open the cheque acceptor side-box, security enclosure and cash acceptor cassettes are taped to either the base-plate of the 80-column printer, or to the top of the security enclosure.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-3

Page 90: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationOpening The ATM

How To Open The ATM 7

To open the ATM, proceed as follows:

1 Turn the top-box key clockwise.

Note: The key is shipped inside the document bag secured to the outside of the unit.

2 Open the top-box door upwards, until the gas struts are fully extended.

3 Open the security enclosure door.

7-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 91: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationOpening The ATM

How To Open The Cheque Acceptor Side-Box 7

The cheque acceptor side-box has a locking handle and may also have a controlled access electronic lock. For instructions on how to open the controlled access electronic lock, refer to the section “How To Unlock And Lock A Controlled Access Electronic Lock”.

To open the cash acceptor side-box with locking handle only, proceed as follows:

1 Insert the key into the keylock on the locking handle and turn it counterclockwise.

2 Turn the locking handle counterclockwise and open the door.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-5

Page 92: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

How To Unlock And Lock A Standard Security Enclosure 7

The standard security enclosure of your ATM will have a locking handle plus one lock (a primary lock), or two locks (a primary and a secondary lock). The possible lock types for primary and secondary locks are as follows:

● Primary lock types:● Keylock● Combination lock● Combination lock with silent alarm● Combination lock with keylock

● Secondary lock types:● Keylock● Combination lock● Combination lock with silent alarm● Combination lock with electronic override.

Note: The make of lock fitted (Standard or Sargent and Greenleaf) depends on the configuration of the ATM. The procedures for opening and closing the locks are the same for both makes.

The following illustration shows the relative positions of primary and secondary locks.

0

90

80

70

6050

40

30

20

10

0

90

80

70

6050

40

30

20

10

Primary Lock

Secondary Lock

Locking Handle

7-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 93: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

If you have both primary and secondary locks fitted to your security enclosure, they must be unlocked in the following order: unlock the secondary lock, followed by the primary lock and then use the handle to retract the bolt and open the door. To lock the security enclosure: close the door and use the handle to operate the bolt, then lock the primary lock, followed by the secondary lock.

Keylocks 7

The pair of keylock keys supplied with your ATM have been pre-cut to a random factory-set combination. If one key should get lost, then you should get a new pair of keys and then change the keylock setting.

How To Unlock A Keylock 7

To unlock a keylock, insert the key into the lock and turn it clockwise as far as it will turn.

How To Lock A Keylock 7

To lock a keylock, turn the key counterclockwise as far as it will turn and then remove the key.

Combination Locks 7

Three variants of combination lock may be fitted to your ATM:

● Basic combination lock● Combination lock with integral keylock● Combination lock with a silent alarm option.

All the variants of the combination lock are three-number combination locks.

The locks are precision locks, therefore, extreme care must be taken to align combination numbers with the index.

Turn the dial slowly and steadily. If, after turning the dial the correct number of revolutions, any number is turned beyond the index, the entire series of combination numbers must be re-dialled.

Do not turn the dial back to regain a proper alignment of the number and index, because each time a selected number is aligned with the index a revolution is counted.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-7

Page 94: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

The procedures for unlocking and changing the combination on a combination lock are the same regardless of whether the lock is a primary or secondary lock.

Factory Setting 7

If the combination lock is set at the original factory setting of 50, you unlock it as follows, dialling on the opening index:

1 If a keylock is fitted to the combination lock, insert the key into the lock and turn it clockwise.

2 Turn the dial a minimum of four turns counterclockwise and stop on 50.

3 Turn the dial slowly clockwise until the bolt retracts. The lock is now open. Use the handle on the door to retract the door bolt and open the door.

Customer Setting Combination 7

If the combination has been set at a three-number combination, for example 36-82-44, unlock it as follows:

1 If a keylock is fitted to the combination lock, insert the key into the lock and turn it clockwise.

2 Turn the dial counterclockwise, passing the first number (36) three times, stop on the first number (36) the FOURTH time.

3 Turn the dial clockwise, passing the second number (82) twice, and stop on the second number (82) the THIRD time.

4 Turn the dial counterclockwise, passing the third number (44) once, and stop on the third number (44) the SECOND time.

0

90

80

70

6050

40

30

20

10

Changing Index

Opening Index

Dial

7-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 95: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

5 Turn the dial clockwise until the bolt retracts. The lock is now open. Use the handle on the door to retract the door bolt and open the door.

How To Operate The Silent Alarm 7

The silent alarm is triggered, if fitted, by adding 10 to the first number of the combination. For example if the first number was 34, dial 44 to trigger the silent alarm. Dial the next two numbers of the combination as normal, the combination lock will open as normal but the alarm will have been triggered.

How To Lock The Combination Lock 7

To lock the combination lock, turn the dial at least four complete turns counterclockwise. If a keylock is fitted to the combination lock, turn the dial until 0 is in line with the opening index and then turn the key counterclockwise and remove it from the lock.

How To Change The Combination 7

Detailed instructions on how to change the combination of a lock are inside the security enclosure.

Combination Lock And Separate Keylock 7 Unlocking 7

On arrival at the site, the combination lock is set at the original factory setting of 50. To unlock the security enclosure, proceed as follows:

1 Turn the dial of the combination lock until 0 is under the index mark.

2 Turn the dial of the combination lock counterclockwise until 50 is under the index mark for the FOURTH time.

Note: Combination locks are precision locks, therefore, extreme care must be taken to align combination numbers with the index.

Index Mark

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-9

Page 96: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

Turn the dial slowly and steadily. If any of the numbers in the combination is turned beyond the index, the entire series of numbers must be re-dialled.

3 Turn the dial clockwise until 0 is under the index mark or until it stops. The combination lock is now open.

4 Insert the key into the keylock and turn it clockwise to unlock the keylock.

5 Turn the locking handle clockwise through approximately 45o to retract the door bolt. The door is now unlocked.

7-10 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 97: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

Locking 7

To close and lock the security enclosure proceed as follows:

1 Close the door.

2 Turn the locking handle through approximately 45o to the vertical position to engage the door bolt.

3 Turn the key in the keylock counterclockwise and then remove the key.

4 Lock the combination lock by turning the dial at least four complete turns counterclockwise.

Customer Setting Combination 7

If the combination has been set at a three-number combination, for example 36-82-44, unlock it as follows:

1 If a keylock is fitted to the combination lock, insert the key into the lock and turn it clockwise.

2 Turn the dial counterclockwise, passing the first number (36) three times, stop on the first number (36) the FOURTH time.

3 Turn the dial clockwise, passing the second number (82) twice, and stop on the second number (82) the THIRD time.

4 Turn the dial counterclockwise, passing the third number (44) once, and stop on the third number (44) the SECOND time.

5 Turn the dial clockwise until it stops. The lock is now open. Use the handle on the door to retract the door bolt and open the door.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-11

Page 98: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Standard Security Enclosure

How To Lock The Combination Lock 7

To lock the combination lock, turn the dial at least four complete turns counterclockwise. Turn the dial until 0 is in line with the opening index and then turn the key counterclockwise and remove it from the lock.

How To Change The Combination 7

Detailed instructions on how to change the combination of a lock are inside the security enclosure.

7-12 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 99: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock An Electronic Lock

How To Unlock And Lock An Electronic Lock 7

Unlocking 7

To unlock the security enclosure proceed as follows:

1 With the keypad in its vertical position, enter the first six digits of the combination (set to 123456 when shipped from factory). If the sequence is entered correctly, the lock will beep and the led flash. If the lock has been set to operate on a single combination, proceed to step 3.

2 If the lock is set to operate on a dual combination, enter the second six digits of the combination (set to 456789 when shipped from factory). If the sequence is entered correctly, the lock will beep and the led flash.

3 Turn the keypad clockwise to unlock the lock.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-13

Page 100: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock An Electronic Lock

4 Turn the keylock clockwise to unlock the lock.

5 Turn the safe handle counterclockwise to open the door.

Note: If when entering a combination you enter the wrong combination 4 times, a 5 minute time delay period is activated. During this time the led on the lock will flash red at 10 second intervals. You must wait until the end of the 5 minute period before attempting to enter the correct combination.

Note: If fitted, the silent alarm may be activated by entering one number higher or lower for the last digit of a combination. For example, if the combination was 1-2-3-4-5-6, entering 1-2-3-4-5-5 or 1-2-3-4-5-7 would activate the silent alarm.

Note: Repeated beeping of the lock during an opening sequence indicates that the lock battery requires replacing. If the lock keypad is completely “dead”, that is, it makes no sound or flashes, follow the emergency opening procedure to open the lock prior to having the battery replaced.

Locking 7

To lock the security enclosure proceed as follows:

1 Close the security enclosure door and turn the handle clockwise.

2 Turn the keylock counterclockwise

3 Turn the keypad counterclockwise until the keypad is vertical. The door should now be locked.

7-14 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 101: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock An Electronic Lock

Emergency Opening Procedure 7

If the keypad is completely “dead”, that is, it does not flash or beep, it is an indication that the lock battery requires replacing.

To open the lock when it is in this condition you must hold a new 9 volt battery against the terminals of the lock. The larger battery terminal must be against the larger of the lock terminals. The battery must be held in place while carrying out the normal procedures for opening the lock.

Note: Only alkaline batteries must be used when replacing the battery in the lock.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-15

Page 102: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Controlled Access Electronic Lock

How To Unlock And Lock A Controlled Access Electronic Lock 7

Note: For ATMs with security enclosures fitted with a Kaba Mas (Mas-Hamilton) controlled access electronic lock, refer to the following Kaba Mas Group publications for details of how to set up and manage the operations of the lock:

● CENCON System 2000 Access Control System● Getting Started Guide● Supervisor Guide● Special Supervisor Guide● FLM Dispatcher Guide● Route Dispatcher Guide● CENCON 2000 System Guide.These publications can be purchased from the following order point:

Kaba Mas Corporation749, W. Short StreetLEXINGTON, Kentucky40508Tel: (1) (1) 859 253-4744Toll Free (USA Only) 888 959-4715Fax: (1) 859-225-2655

Note: For the attention of Customer Service Manager.

The controlled access electronic lock, may be fitted with an additional sub-lock on the cheque acceptor door. The possible combinations of locks are as follows:

● Master lock● Master lock with sub-lock.

To operate the master lock and sub-lock, you will require the following:

● Personal Identifier key (PI key)● 6-digit access code - obtained from the Key Management Centre

(KMC).

7-16 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 103: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Controlled Access Electronic Lock

Unlocking the Master Lock7

To unlock the master lock, proceed as follows:

1 Contact the KMC.

2 Give requested details to verify your identity to the KMC.

3 Specify which areas on the ATM you want to access.

4 Take note of the 6-digit access code (three pairs of two), allocated by the KMC.

5 Unlock and open the exterior of the ATM.

6 Spin the lock dial counterclockwise to charge the lock, until EC is displayed on the LCD.

Note: If DL (Dial Left) is displayed, you must only turn the dial to the left (counterclockwise).

7 Turn the dial to the home position.

8 Enter the 6-digit access code provided by the KMC on the keypad.

9 IPI should be displayed on the LCD.

2 34

5

1

* 6

#

78 9

0

KeypadLCD

Dial(Opening/Closing)

Key Reader

Home Position

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-17

Page 104: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Controlled Access Electronic Lock

10 Hold the PI key against the key reader to verify a valid user identity. If sub-lock access is required, the appropriate authority is passed to the PI key at this stage.

11 If the correct 6-digit code has been entered and a valid PI key has been pressed against the key reader, OPr will be displayed on the LCD.

Note: If an incorrect code or PI key is used or there is a bad PI key contact, a lightning bolt symbol will be displayed on the LCD, indicating an error condition.

If the error condition was caused by a bad PI key contact, YOU HAVE ONE MORE ATTEMPT AT OPENING THE LOCK. If the error condition occurs after the 2nd attempt, contact the KMC immediately.

12 Turn the lock dial a quarter turn (90o) clockwise to release the bolt.

13 Open the security enclosure.

2 34

5

1

* 6

#

78 9

0

LCD

Keypad

Dial(Opening/Closing)

Key Reader

PI Key

7-18 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 105: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Controlled Access Electronic Lock

Locking the Master Lock 7

To lock the master lock, proceed as follows:

1 Close the security enclosure.

2 Turn the lock dial counterclockwise to activate the bolt and charge the lock until IPI is displayed on the LCD.

3 Hold the PI key against the key reader.

4 Take a note of the unique 4-digit close code that is displayed, as it will be required by the KMC.

5 Close the exterior of the ATM.

6 Contact the KMC.

Note: Ensure that all the locks and doors on the ATM are closed and locked before contacting the KMC.

7 Verify identification.

8 Provide the 4-digit close code to the KMC.

9 The KMC will inform you that either the code is correct or give you the correct procedure to follow if the close code is wrong.

Unlocking the Sub-Lock 7

If a sub-lock is configured on your cheque acceptor door, proceed as follows:

1 Carry out Steps 1 to 10 of “Unlocking the Master Lock”.

Note: The code displayed on the LCD will depend on which area of the ATM you requested access to.

2 Insert the key into the keylock on the locking handle and turn it counterclockwise.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-19

Page 106: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Controlled Access Electronic Lock

3 Hold the PI key against the key reader of the sub-lock.

4 The LED flashes three (3) times. You have eight (8) seconds to unlock the sub-lock by turning the locking handle counterclockwise to release the catch. If the locking handle cannot be moved, contact the KMC for another access code.

Note: The locking handle cannot be turned before the LED flashes. After turning, the catch remains in position until the lock is closed.

5 Open the cheque acceptor side-box door.

Locking the Sub-Lock 7

To lock the sub-lock, if configured, proceed as follows:

1 Close the cheque acceptor side-box door and turn the locking handle clockwise to hold the catch.

2 Turn the key in the keylock clockwise and remove the key.

3 Hold the PI key against the key reader of the sub-lock until the LED flashes four (4) times. This indicates the lock is closed.

4 On the master lock, turn the lock dial counterclockwise and charge the lock until IPI is displayed on the LCD.

5 Hold the PI key against the key reader of the master lock.

6 Take a note of the unique 4-digit close code that is displayed, as it will be required by the KMC.

7 Close the exterior of the ATM.

Note: Ensure that all the doors and locks on the ATM are closed and locked before contacting the KMC.

7-20 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 107: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationHow To Unlock And Lock A Controlled Access Electronic Lock

8 Contact the KMC.

9 Verify your identification.

10 Provide the 4-digit close code to the KMC.

11 The KMC will inform you that either the code is correct or give you the correct procedure to follow if the close code is wrong.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-21

Page 108: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationRemoving The ATM From Its Pallet

Removing The ATM From Its Pallet 7

To remove the ATM from its pallet using lifting trolleys proceed as follows:

1 Unlock and open the ATM security enclosure.

2 Use a 19 mm (3/4 in.) spanner and the same size socket to remove the four bolts attaching the ATM to the pallet.

3 Close the security enclosure.

7-22 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 109: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationRemoving The ATM From Its Pallet

4 If the ATM is fitted with a standard side-box, remove the kick plate from the bottom of the side-box by removing the countersunk screw, and pulling the plate out and to the rear of the ATM. Retain the kick plate and screw for using in the same position later.

If the ATM is fitted with a cheque acceptor side-box (protrudes from the side of the ATM), proceed to step 5.

1

2 2

1

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-23

Page 110: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationRemoving The ATM From Its Pallet

5 Place the pallet extension board at the left-hand side of the pallet.

6 Put the lifting trolleys on either side of the pallet, placing one lifting trolley on the extension board, and insert the toes of the trolleys under the ATM. Strap the trolleys to the ATM and insert packing where necessary to protect the ATM’s paintwork.

7-24 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 111: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationRemoving The ATM From Its Pallet

7 Pump up both trolleys to lift the ATM clear of the pallet. Slide the pallet out from under the ATM.

8 Place safety boards under the ATM. Lower the ATM until it is resting on the safety boards.

9 Loosen the straps surrounding the trolleys and ATM, then remove the extension board.

10 Adjust the trolleys, straps and packing, ensuring the trolleys are as near as possible to the ATM.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 7-25

Page 112: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing The ATM For InstallationRemoving The ATM From Its Pallet

11 Pump up both trolleys to lift the ATM clear of the safety boards. Slide the safety boards out from under the ATM.

12 Move the ATM to the installation site.

7-26 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 113: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling The ATM – Physical Installation

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 8

Installing The ATM – Physical Installation

Introduction 8-1Installation Categories 8-1Connecting Cables 8-1

Fitting The Severe Environment Parts 8-2Dismantling The Severe Environment Parts 8-2Relocating The Position Of The EOP 8-4Removing The 80-Column Printer And Slide 8-5Fitting The Severe Environment Parts 8-12

Positioning The ATM 8-24

Fitting An Infill Panel 8-25Infill Panel (5088) 8-25Infill Panel (5688) 8-26

Fitting The Collar 8-28Fitting The Standard Collar With Facia Light 8-28Fitting The Standard Collar With Advert Light 8-33

Sealing The Collar And Bolting The ATM To The Plinth 8-40

Page 114: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling The ATM – Physical Installation

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 115: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8

-1

IntroductionInstalling The ATM – Physical Installation8

Introduction 8

Installation Categories 8

The physical installation of 5887 Drive-Up is divided into three different categories.

These installation categories are described in Chapter 1.

Connecting Cables 8

If the ATM is being installed within a minimum footprint clearance area, due to limited side clearance, cable connections must be carried out before the unit is moved into its final location. If however, the ATM is located in a recommended footprint clearance area (or more), cable connections can be carried out before or after the final siting of the unit.

If required, refer to “Connecting Cables to the ATM” and connect cables before proceeding with the installation.

Caution The design of the plinth must be such that it will not damage the cables which exit the ATM through the base of the security enclosure. For more details, refer to Chapter 1.

Page 116: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

Fitting The Severe Environment Parts 8

The severe environment module is shipped detached from the ATM. It is recommended that the module is fitted to the ATM prior to installation through the wall.

To fit the module proceed as follows:

Dismantling The Severe Environment Parts 8

When dismantling the severe environment, make sure that you retain all parts, including screws, in preparation for fitting to the ATM.

1 Remove the severe environment parts from their packaging.

2 Disconnect the fan and heater connections from the connector box.

8-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 117: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

3 Disconnect the heater harness from the heater element connections.

4 Remove the three M4 nuts securing the fan assembly to the side access panel.

1 2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-3

Page 118: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

Relocating The Position Of The EOP 8

It is recommended that the position of the EOP is altered, to give greater access to the 80-column printer and the side-access service panel. To relocate the position of the EOP, proceed as follows:

1 Remove the M6 screw from its storage location on the top-box bracket.

2 Remove the M6 nut from the lever pivot stud. Pull the lever free of the pivot stud.

8-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 119: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

3 Relocate the EOP by lifting it towards the top-box. Align the two holes on the EOP support bracket and the top-box bracket. Secure the EOP with the M6 screw removed earlier.

Removing The 80-Column Printer And Slide 8

To remove the 80-column printer and slide, proceed as follows:

1 Open the top-box of the ATM.

Note: There are two variants of the Letter Quality Document (LQD) statement printer. The following illustrations show a Parallel Port or "Open" LQD printer, however, the steps for removing the printer are the same in all cases.

1 2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-5

Page 120: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

2 Press the green latch and using the green handle, slide the printer forwards, until its slides are fully extended.

3 Disconnect the power and SDC connectors from the printer. Feed the cables back through the hole in the metalwork and cut the three cable ties securing the cables to the printer.

1

2

8-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 121: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

4 Push the clips on the inside of the slides and, with the help of an assistant, slide the printer forwards and remove it from the ATM.

Warning: The printer is heavy. Make sure that you have an unobstructed area in which to move and place it before you lift it from the ATM.

5 Push the remaining slides back into the ATM.

6 Remove the right-hand slide beam by gently pulling the slide form, and pulling the slide to the rear of the ATM to release the mushroom studs from the key holes.

1

2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-7

Page 122: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

Removing The Side-Access Service Panel

To remove the side-access service panel proceed as follows:

1 Disconnect the terminals from the auto-supervisor switch and remove the switch from the bracket. Retain the switch for using in the same position later.

8-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 123: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

2 Remove the M6 locknut from the stud on the top-box and retain it for using in the same position later.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-9

Page 124: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

3 Remove the circlip securing the gas-strut and relocate it on the stud on the top-box. Secure it with the M6 locknut removed previously.

Caution: Ensure the top-box is supported before relocating the gas-strut.

4 Remove the securing stud from the gas-strut’s original location and retain it for using in the same position later.

1

2

8-10 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 125: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

5 Remove the side-access service panel by slackening three M4 locknuts at the rear, and removing the two M6 screws on the base. Retain the two screws for using in the same position later.

6 Remove the side-access service panel.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-11

Page 126: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

Fitting The Severe Environment Parts 8

To fit the severe environment parts proceed as follows:

1 Fit the new side-access service panel with the two retained M6 screws at the base and tightening the three M4 locknuts at the rear.

2 Fit the gas-strut securing stud, retained earlier, to the new side-access service panel and move the piston on to the stud.

3 Secure the gas-strut on to the stud with a circlip.

Warning: Ensure that the circlip is secure before proceeding to the next step.

8-12 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 127: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

4 Connect the heater harness to the terminals. Ensure that both terminals are pushed through the hole in the side-access service panel and that the grommet is located in the hole.

1 2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-13

Page 128: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

5 Fit the severe environment fan assembly to the side-access service panel with the three M4 locknuts. Do not tighten the locknuts.

Note: Ensure that the fan and heater connections project through the cut out in the side-access service panel.

8-14 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 129: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

6 Secure the heater and fan harnesses to the bracket on the side-access service panel using a cable tie.

7 Fit the severe environment housing assembly to the two studs on the side wall of the top-box and secure with two M4 locknuts.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-15

Page 130: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

8 Fit the entry panel to the housing assembly with two M4 x 6 countersunk screws at the top and two M4 x 6 screws at the bottom.

9 Slide the severe environment fan assembly towards the entry panel. Tighten the three locknuts.

8-16 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 131: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

10 Connect the fan, heater and thermostat connections to the terminal box. Ensure that the grommets are located in the slots in the connector box.

11 Fit the connector box assembly to the fan assembly using one M4 screw.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-17

Page 132: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

12 Connect the AC power harness to the connector box.

13 Refit the auto-supervisor switch to the bracket on the side- access service panel. Reconnect the harness to the terminals.

Sealing The ATMThe final stage of fitting the severe environment is to seal the ATM to prevent negative pressure within the ATM.

1 Cut the foam gaskets into sections and fit between the existing gaskets on the top-box.

8-18 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 133: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

2 Fit the two rubber seals to either side of the top-box.

3 Fit the seal (445-0670113) between the two hinges on the top-box.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-19

Page 134: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

4 Cover the gap between the top-box and the sleeve on both sides with adhesive tape. If enhanced audio is not configured in the ATM, cover the speaker slots on the facia with adhesive tape.

5 Open the security enclosure.

8-20 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 135: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

There are two types of security enclosure. On one, the security enclosure door sits level with the enclosure when it is closed, and on the other, the door protrudes when closed.

If the security enclosure door sits level with the enclosure, proceed to step 6. If the door protrudes, proceed from step 8.

6 Fit the adhesive gasket (445-0655433) to the flange on the right-hand side of the security enclosure and the adhesive gasket (445-06455434) to the side wall on the left-hand side of the security enclosure.

7 Proceed to step 11.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-21

Page 136: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

8 Fit adhesive gasket (445-0655433) to the left and right-hand side of the security enclosure door.

9 Remove the adhesive backing from the seals (445-0655684) and fix them to the top and bottom of the security enclosure door.

8-22 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 137: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Severe Environment Parts

10 Replace the printer slide beam.

11 With the help of an assistant, replace the printer.

12 Connect the power and SDC connectors and secure the cables with cable ties.

13 Push the printer back into the ATM until it clicks into place.

14 Remove the M6 screw from the support bracket and lower the EOP.

15 Move the lever to its original location and secure with the M6 nut.

16 Return the M6 screw to its storage location.

17 Close the exterior of your ATM.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-23

Page 138: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationPositioning The ATM

Positioning The ATM 8

To position the ATM through the hole in the wall proceed as follows.

1 Using the lifting trolleys, move the ATM onto the plinth and through the hole in the wall so that the sleeve protrudes at the other side.

Note: The holes in the base of the security enclosure should line up with the fixing holes in the plinth.

2 Remove the ATM from the lifting device.

Warning If you have to slide the ATM off the lifting trolleys, take care that the ATM does not fall over.

8-24 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 139: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting An Infill Panel

Fitting An Infill Panel 8

An infill panel is required when installing 5887 Drive-Up into a hole used by a previous 5088 or 5688 installation.

Infill Panel (5088) 8

For fitting a 5088 infill panel, proceed as follows:

1 Place the infill panel over the sleeve and mark its outline on the wall.

2 Using the infill panel as a template, mark centre points for the four fixing holes.

3 Remove the infill panel.

4 Drill fixing holes and insert the M6 wall fixings. Remove the bolts from the fixings.

5 Replace the infill panel and check its position before finally bolting it to the wall using the M6 wall bolts and washers.

6 Seal the outer edge of the panel to the wall using silicone sealant.

The hole in the wall is now prepared for the installation of the ATM.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-25

Page 140: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting An Infill Panel

Infill Panel (5688) 8

For fitting a 5688 infill panel, proceed as follows:

1 Place the infill panel over the sleeve and mark its outline on the wall.

2 Remove the infill panel.

3 Using lifting trolleys, move the ATM back from the hole in the wall.

4 Loosely fit the two mounting brackets to the infill panel using four M6 screws, four washers and four nuts.

5 Place the infill panel over the hole in the wall, ensuring that it is placed within the outline drawn previously.

6 With the help of an assistant or with the use of tape, temporarily secure the infill panel to the wall.

8-26 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 141: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting An Infill Panel

7 If required, adjust the two mounting brackets until they are tight against the inside face of the wall.

8 Using the two mounting brackets as templates, mark centre points for the six fixing holes.

9 Remove the infill panel.

10 Drill fixing holes and insert the M6 wall fixings. Remove the bolts from the fixings.

11 Replace the infill panel and check its position before finally bolting it to the wall using the M6 wall bolts.

12 Tighten the two mounting brackets to the infill panel using the four screws, four washers and four bolts that were loosely fitted previously.

13 Seal the outer edge of the panel to the wall using silicone sealant.

14 Using the lifting trolleys, move the ATM through the hole in the wall so that the sleeve protrudes at the other side.

The hole in the wall is now prepared for the installation of the ATM.

Wall Mounting Bracket

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-27

Page 142: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

Fitting The Collar 8

The following sections describe the two different collar assemblies available for the 5887 Drive-Up:

● Standard collar with facia light● Standard collar with advert light

Fitting The Standard Collar With Facia Light 8

These instructions should be followed for installations where a 5887 Drive-Up is installed at the NCR recommended height.

1 Fix the vertical collar mounting brackets to the sleeve using four M4 x 6 countersunk thread forming screws on each side. The brackets are not interchangeable and must be fitted as shown, with the tabs facing forward.

8-28 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 143: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

2 Fix the bottom collar mounting bracket to the sleeve as shown, using three M4 x 6 thread forming screws.

Note: Ensure the bracket tabs are aligned with the lower bracket tabs on the vertical collar mounting brackets.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-29

Page 144: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

3 Fit the “U” shaped collar piece to the brackets by sliding it onto the bracket tabs, as shown.

1 2

8-30 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 145: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

4 Apply silicone sealant to both sides of the lower collar piece, as shown.

5 Slide the top collar assembly into position.

6 Using a damp cloth, wipe any excess silicone sealant from the join between the lower and top collar.

7 Fix the top collar assembly with four M4 x 10 screws through the white light panel and into the mounting bracket.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-31

Page 146: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

8 Insert the facia light fluorescent tube and turn it until its contacts are tightly held.

9 Hook the facia light window under the lip of the top collar piece and swing it up into position. Fit a clip over the facia and secure it with four M3 countersunk machine screws.

10 Proceed to the section “Sealing the Collar and Bolting the ATM to the Plinth”.

8-32 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 147: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

Fitting The Standard Collar With Advert Light 8

These instructions should be followed for installations where a 5887 Drive-Up is installed at the NCR recommended height.

Note: The standard collar with advert light requires a decal. Fix the advert decal to the surface of the light panel before fitting the collar. Make sure that the panel is clean, dry and dust free prior to applying the decal. The decal may have to be fitted to the inside or outside of the light panel depending on the decal design.

1 Fix the left and right collar mounting brackets to the sleeve using four M4 x 6 countersunk thread forming screws on each side. The brackets are not interchangeable and must be fitted as shown, with the tabs facing forward.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-33

Page 148: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

2 Fix the bottom collar mounting bracket to the sleeve as shown, using three M4 x 6 thread forming screws.

Note: Ensure the bracket tabs are aligned with the lower bracket tabs on the vertical collar mounting brackets.

8-34 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 149: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

3 Fit the “U” shaped collar piece to the brackets by sliding it onto the bracket tabs, as shown.

1 2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-35

Page 150: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

4 Apply silicone sealant to both sides of the lower collar piece, as shown.

5 Slide the top advert collar assembly into position. Push the two harness connectors from below and through the hole in the bottom right hand side of the collar.

6 Using a damp cloth, wipe any excess silicone sealant from the join between the lower and top collar.

8-36 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 151: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

7 Fix the top advert collar assembly with four M4 x 10 screws through the white light panel and into the mounting bracket.

8 Fit the two harness connectors to the top advert collar and secure with two M3 x 20 screws and two nuts.

Caution: Do not over-tighten the two screws as this may cause damage to the harness connectors.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-37

Page 152: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

9 Connect the harness earth lead to the earth stud on the top advert collar and secure with a M4 nut.

10 Insert the facia light fluorescent tube and turn it until its contacts are tightly held.

11 Clip in the advert light window.

Caution Ensure that the window is secured at the top and down both sides, and that both bottom clips are engaged.

8-38 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 153: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationFitting The Collar

12 Hook the facia light window under the lip of the top collar piece and swing it up into position. Fit a clip over the facia and secure it with four M3 countersunk machine screws.

13 Proceed to the section “Sealing the Collar and Bolting the ATM to the Plinth”.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-39

Page 154: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationSealing The Collar And Bolting The ATM To The Plinth

Sealing The Collar And Bolting The ATM To The Plinth 8

The final stage of installation is to create a seal around the collar and bolt it down. The following picture shows the standard collar without advert light, however, the method of fitting the weather seal is the same in all cases.

1 Apply four strips of self-adhesive weather seal gasket to the rear faces of the collar, and two small strips to the rear of the lower and top collar join.

Caution: Ensure the top gasket strip is positioned at the top edge of the collar and forms a “T” on top of the vertical strips, to prevent water gathering behind the collar.

2 Pull the ATM hard against the building wall to compress the weather seal.

8-40 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 155: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationSealing The Collar And Bolting The ATM To The Plinth

3 Open the security enclosure and bolt the ATM to the floor/plinth.

Note: Bolts are not provided with the unit, they must be supplied by the owning organization. You will require:

● 4 bolts 16mm (0.63in.) diameter x 120mm (4.72in.) long● 4 anchor washers to fit the bolts. These must be at least 3mm

(0.12in.) thick and have a maximum outside diameter of 40mm (1.57in.) and an inner diameter of 18 mm (0.71 in.).

4 Close the security enclosure.

5 If the ATM is fitted with a standard side-box, attach the kick plate to the bottom of the side-box by locating the pin at the front of the ATM, pushing the other side into position and securing with the countersunk screw.

If the ATM is fitted with a cheque acceptor side-box (protrudes from the side of the ATM), proceed to step 6.

6 Trim off any excess weather seal.

2

1

2

1

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 8-41

Page 156: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Physical InstallationSealing The Collar And Bolting The ATM To The Plinth

7 Seal the top and vertical edges of the collar to the wall, or infill panel, using silicone sealant from the collar kit box.

Caution: Do not seal the bottom edge of the collar.

8-42 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 157: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling The ATM – Internal Packaging And Cables

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 9

Installing The ATM – Internal Packaging And Cables

Removing The Internal Packaging 9-1Module Locations 9-1Operator Panel 9-2Security Enclosure 9-2Currency Dispenser 9-3Cash Acceptor 9-5Cheque Acceptor 9-6PC Core 9-7Receipt And Journal Printers 9-8Magnetic Card Reader/Writer 9-9Statement Printer 9-10

Connecting Cables To The ATM 9-12Internal Cables 9-13Power Cable 9-15Connecting External Cables 9-17

Page 158: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling The ATM – Internal Packaging And Cables

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 159: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9

-1

Removing The Internal PackagingInstalling The ATM – Internal Packaging And Cables9

Removing The Internal Packaging 9

This section describes how to remove the internal packaging from all modules. Ignore those steps which apply to modules not configured into the ATM.

Note 1: The amounts and types of packing may be subject to change without notice.

Note 2: After removing the internal packaging, check that all modules rack out and in, and lock in position.

Module Locations 9

The following illustration shows the location of modules in the 5887 Drive-Up ATM. The modules in your terminal may differ from those shown.

Statement Printer

Top-Box

Digital AudioVolume Control

Supervisor/Operator Panel

Currency DispenserorCash Acceptor

Power On/OffSwitch

Receipt / Journal Printerand Card Reader

PC Core

Card Capture Bin

Power Supply

Security EnclosureDoor

Standard Side-Boxor

Cheque AcceptorSide-Box

Page 160: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Operator Panel 9

Remove the foam block from the front of the operator panel.

Security Enclosure 9

Remove and retain the plastic document bag taped to the bottom of the security enclosure.

9-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 161: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Currency Dispenser 9

Remove the tape from around the dispenser latch-handle.

Note: The position and appearance of the latch handle may differ from that shown.

Remove the foam block and tape from the front of the currency dispenser.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-3

Page 162: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Remove tape from cassette latches on right-hand side and across the cassette and purge bin handles.

If your ATM has a dispenser with four cassettes, pull out the bottom cassette and remove the packaging from beneath the dispenser chassis.

Remove the strip of weather seal from inside the purge bin.

9-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 163: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Cash Acceptor 9

Remove the tape and foam block from the latch-handle, and the tape and foam from the bottom of the cash acceptor.

Remove tape and foam blocks from the locations shown below.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-5

Page 164: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Cheque Acceptor 9

Remove the shipping bracket securing the cheque acceptor to the side-box. Replace the two nuts on the bottom of the side-box, ensuring the door-latch bracket remains in position. Discard the screw and shipping bracket.

Remove tape from the locations shown below.

9-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 165: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

PC Core 9

Remove and retain the power cable and small plastic bag taped to the PC Core.

Remove the cardboard from the top of the PC Core.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-7

Page 166: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Receipt And Journal Printers 9

Remove the tape and foam packing piece from the printer tray release latch.

Remove the pieces of tape securing the paper rolls to the modules.

9-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 167: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Magnetic Card Reader/Writer 9

Remove tape from the release plunger for the open card capture bin and the foam block from inside the bin.

Remove the cable tie and tape from the card capture container.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-9

Page 168: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Statement Printer 9

Remove the two brackets securing the statement printer to the top-box.

Remove the cardboard from the front of the support frame.

9-10 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 169: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesRemoving The Internal Packaging

Remove the tape from both printer carriage levers.

From the front of the facia, remove the sheet of cardboard from the statement printer aperture.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-11

Page 170: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

Connecting Cables To The ATM 9

The cables used to make connections to the ATM must conform to the cable specifications and details of preparation provided in Chapter 2.

Note: If the ATM is being installed within a minimum footprint clearance area, cable connections must be carried out before the unit is moved into its final location, due to limited side clearance. If however, the ATM is located in a recommended footprint clearance area, cable connections can be carried out before or after the final siting of the unit.

Cables to be connected to the ATM fall into three categories:

● Internal cables requiring additional grounding by means of a “P” clamp (if not configured prior to the ATM’s dispatch from the factory)

● Power cable, not requiring additional grounding● External cables requiring additional grounding by means of a

“P” clamp.

The Remote Relay, Remote Status Indicator, Alarms Interface Cable and High Order RS-232 Communication cables require additional grounding. Follow the special procedures given in the next section.

Caution Cables must be grounded where indicated to make sure that the ATM meets EMC requirements.

To connect the cables to the ATM, proceed as follows:

1 Open both the top-box and the security enclosure of the ATM.

9-12 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 171: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

2 Check that the mains ON/OFF switch is in the OFF position (pressed in at the 0 side).

Internal Cables 9

If the ATM has been ordered without the internal cables (between the PC core and the I/O panel) configured, then, using the NCR kit 5887-K678-V001, connect the cables to your ATM as follows. Otherwise, proceed to the next section.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-13

Page 172: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

1 Clip the connectors through the appropriate holes on the rear of the panel.

2 Route the cables through the hole at the rear of the security enclosure, into the top-box and connect them to the appropriate connectors on the PC core, as shown below.

9-14 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 173: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

3 Secure the cables using cable ties.

4 Clip a “P” clamp around the stripped section of each cable that has been connected, then attach all clamps to the threaded stud on the underside of the panel using an M4 nut.

Note: Attach all the clamps to the stud, even if some are not used, as they may be required at a later date.

Power Cable 9

To connect the power cable to your ATM, proceed as follows:

M4 NutP Clamp

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-15

Page 174: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

1 Remove the two M4 nuts securing the two cover plates to the cable entry bracket. Remove the cover plates.

1 2

9-16 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 175: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

2 Insert the end of the power cable through the cable entry hole in the base of the security enclosure. Connect the power cable to the socket on the power supply.

Warning Make sure that the power supply cable is not connected to the AC outlet while you are connecting it to the ATM.

3 If you are connecting cables after installing the ATM, connect the power cable to the AC outlet. Otherwise, leave the power cable disconnected from the AC outlet until after the ATM is installed and bolted down.

4 If you have no other cables to connect, proceed from step 6 in the next section. Otherwise, proceed to the next section.

Connecting External Cables 9

To connect a Remote Relay, Remote Status Indicator, High Order RS-232 Communication or Alarms Interface cable to the ATM proceed as follows:

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-17

Page 176: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

1 Insert the ends of the communications cables through the cable entry hole in the base of the security enclosure. Connect the cables to the appropriate connectors on the panel.

9-18 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 177: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

2 Screw an earth stud into one of the three threaded holes on the inside wall of the security enclosure.

Note 1: The studs are packed in a plastic bag attached to the PC Core chassis.

Note 2: Ensure the area around the threaded hole and the earth stud base is clean for a good electrical contact.

3 Tighten the stud to the security enclosure using a 10 mm (3/8 in.) spanner or socket.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-19

Page 178: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

4 Clip the appropriate sized “P” clamp around the stripped section of each cable to be connected, then, using a 7 mm (9/32 in.) spanner, attach the clamp to the earth stud with the M4 nuts supplied.

Note 1: If the cable has not been stripped, refer to the instructions in Chapter 2.

M4 Nut

P Clamp

9-20 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 179: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

Note 2: The largest clamp should be attached to the earth stud first, then the second largest and so on. Attach all the clamps to the stud, even if some are not used, as they may be required at a later date.

5 Ensure that there are no loose cables and that all modules are free to rack out and in, by either cutting cables to the required length, or securing them inside the ATM.

M4 Nuts Separatingand securing groupsof two cable clamps

3.4 mm (0.13 in.)Clamps facing upward

4.5 mm (0.18 in.)Clamps facing downward

6.0 mm (0.24 in.)Clamps facing downward

Earth Stud in SecurityEnclosure wall

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 9-21

Page 180: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing The ATM – Internal Packaging And CablesConnecting Cables To The ATM

6 Replace the cover plates, ensuring the studs locate in the slots. Slide the plates towards each other, overlapping one with the other, and secure with the two M4 nuts.

7 Switch on the power at the AC outlet and then at the ATM.

8 Close the security enclosure and top-box.

1 2

9-22 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 181: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsConfiguring the ATM

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 10

Configuring the ATM

Introduction 10-1

Currency Cassette Configuration 10-2

Device Configuration 10-3

Communications Configuration 10-4APTRA Self-Service Support 10-4S4I 10-4

40-Column Printer Configuration 10-5Thermal Receipt And Journal Printers 10-5Basic Configuration 10-6Advanced Configuration And Calibration 10-6Dot-Matrix Journal Printer 10-9

80-Column Printer Configuration 10-11Letter Quality Document (LQD) Printers 10-11Adjusting DIP Switch Settings 10-12Adjusting The LQD Printer Paper Hopper 10-14Adjusting The Contrast 10-18

Page 182: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsConfiguring the ATM

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 183: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10

-1

IntroductionConfiguring the ATM10

Introduction 10

After you have completed the hardware installation of the ATM there are certain configuration procedures that must be performed. These depend upon which modules are installed in the ATM.

Note: All dot-matrix printers are pre-fitted with secured paper and ribbons but paper will have to be loaded or fed into the transport.

Refer to the publication, “NCR Personas M Series 5887 Operator Manual” (B006-6359), for details of how to load supplies and how to fit the print head cartridges.

The features which may require configuration are:

● Currency cassette● Device Configuration● Communications● Printers:

● 40-Column printers● 80-Column printer

The configuration of these features is described in the following sections.

For ATMs with a zico board (feature D201), connect the external communications cable from the I/O panel to the customer’s network prior to testing. If this is not possible, then disconnect the internal communications cable from the PC Core and reconnect after testing is complete. Failure to do one of these could result in a system escape.

After completing the configuration of the ATM, refer to the appropriate publication for details of system initialization. If your system software is APTRA™ Self-Service Support, refer to publication “APTRA™ Self-Service Support, System Application User Guide”, B006-6167. If your system software is S4I, refer to publication “Self-Service Terminal Supervisor Functions”, B006-4718.

After configuration and testing, complete and return the Installation Report Form delivered with the ATM.

Finally, under no circumstance should media or any other items be stored inside the ATM, as this may interfere with its operation.

Page 184: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMCurrency Cassette Configuration

Currency Cassette Configuration 10

The currency cassettes should be configured as described in publication “NCR H-8015-STD1-01/02-08 Currency Cassette Owner’s Manual”, B006-1297-C000.

10-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 185: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMDevice Configuration

Device Configuration 10

The ATM has a number of devices which need to be configured at installation.

If your ATM runs APTRA Self-Service Support, then configuration is done using the System Application. Refer to the NCR publication “APTRA Self-Service Support System Application User Guide”, B006-6167.

If your ATM runs S4I system software, then configuration can be done by referring to the NCR publication “Self-Service Terminal Supervisor Functions”, B006-4718.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-3

Page 186: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMCommunications Configuration

Communications Configuration 10

If you intend to use communications, then you must configure the software and hardware. The procedure for configuring your ATM depends on whether your ATM runs APTRA Self-Service Support or S4I:

APTRA Self-Service Support 10

Configuration is described in the NCR publication “APTRA Communications Feature User’s Guide”, B006-0012.

Note: Before you can start to configure the communications, you must have APTRA Self-Service Support installed on your ATM.

For information on NCR certified Communications boards, please refer to the following NCR Intranet site, or contact your local support representative:

http://www.dundee.ncr.com/INFOPROD/Software&Services.htm

S4I 10

Configuration is described in the NCR publication “Self-Service Terminal Supervisor Functions”, B006-4718.

Note: Before you can configure communications in the ATM, you must build and load the applications software on to the ATM. The procedures for building and loading software can be found in NCR publication “Building a Load Disk”, B006-1797.

To configure communications you will require the protocol identification code. If you order communications software, the appropriate documentation, including information on codes, is automatically sent. For more information visit the following NCR Intranet site.

http://www.dundee.ncr.com/INFOPROD/Software&Services.htm

You will also require the communications common and connection parameters and these must be supplied by the owning organisation.

10-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 187: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

40-Column Printer Configuration 10

The ATM may be fitted with one or two 40-column printers – a thermal receipt printer and either a thermal or dot-matrix journal printer.

Note: Full details of all configuration options can be found in chapter 13 of the NCR publication “Service Aids Mini-Manual”, BFM0-0547-A000.

The thermal printers are configured using DIP switches, RESET and ENTER (SET) buttons and feedback from status LEDs. An EEPROM on the interface PCB stores most configuration data.

The dot-matrix printer is configured using DIP switches.

Note: The following adjustments must be performed by a customer engineer.

Thermal Receipt And Journal Printers 10

All the necessary switches and LEDs are accessible through holes in the interface PCB cover:

{LED’s

SW1(ENTER (SET))

SW2(RESET)

DSW2

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-5

Page 188: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

Basic Configuration 10

Adjustments to the following functions can be made using DIP switch DSW2:

● Black Mark mode – switch 1● 5670 Emulation – switch 2● Receipt and/or Journal printer installed – switches 3 & 4.

These adjustments do not update EEPROM data.

To adjust these functions set switches 1 to 4, as appropriate, following the table below:

Note: 0 = off, 1 = ON, x = Don’t care.

Advanced Configuration And Calibration 10

Receipt Form Length setting, Character Set selection and Black Mark Calibration involve updating the EEPROM data. Configuration of these functions is made using DIP switch DSW2.

Configuration is carried out as follows:

Receipt Form Length 10

The Receipt Form length can be set to any number of lines between 24 (default) and the maximum of 55.

1 Make a note of the current DSW2 DIP switch settings.

2 Set DSW2 switch 6 to ON.

3 Set DSW2 switches 1 to 5 to add the required number of lines to the default value of 24.

switch 1 = ON : adds 1 lineswitch 2 = ON : adds another 2 linesswitch 3 = ON : adds another 4 lines

DIP switch DSW2 Switch Setting

Function 8 7 6 5 4 3 2 1

Receipt printer - Black Mark mode ON (default)

0 0 0 0 x x x 1

Receipt printer - Black Mark mode OFF 0 0 0 0 x x x 0

Report 5670 Emulation (default) 0 0 0 0 x x 0 x

Report TEC Emulation 0 0 0 0 x x 1 x

Installed printers - invalid setting 0 0 0 0 0 0 x x

Installed printers - Receipt printer only 0 0 0 0 0 1 x x

Installed printers - Journal printer only 0 0 0 0 1 0 x x

Installed printers - both printers 0 0 0 0 1 1 x x

10-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 189: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

switch 4 = ON : adds another 8 linesswitch 5 = ON : adds another 16 lines

For example: to make the form length 35, set the switches like this:

default:.....................24switch 1 = ON adds .1switch 2 = ON adds .2switch 3 = OFF adds 0switch 4 = ON adds .8switch 5 = OFF adds 0

TOTAL: ...................35

4 Press the RESET button SW2.

5 Press and hold the ENTER (SET) button SW1 until the four LEDs blink. The new form length is now stored in the EEPROM.

6 Restore the previously noted DSW2 DIP switch settings and press the RESET button SW2.

Character Set 10

This setting applies to both the Receipt and Journal printers.

1 Make a note of the DSW2 DIP switch settings.

2 Set the DSW2 DIP switches as shown:

Note: 0 = off, 1 = ON.

3 Press the RESET button SW2.The four LEDs blink – the character set data is now stored in the EEPROM.

4 Restore the previously noted DSW2 DIP switch settings and press the RESET button SW2.

Black Mark Calibration 10

1 Make a note of the DSW2 DIP switch settings.

Switch Setting

Function 8 7 6 5 4 3 2 1

International Character Set (Default) 0 0 0 1 1 0 0 1

Arabic Character Set 0 0 0 1 1 0 1 0

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-7

Page 190: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

2 Ensure that the Receipt printer is properly loaded with suitable paper.

3 Set the DSW2 DIP switches as shown:

Note: 0 = off, 1 = ON.

4 Press the RESET button SW2. Wait until the LEDs have finished flashing then press the Paper Feed button. The printer feeds paper, calibrates the black mark sensor and stores the new data in the EEPROM.

The four LEDs blink to confirm successful calibration. If all four LEDs do not blink – interpret the error from the pattern of the blinking LEDs:

EEPROM data is only updated when calibration is successful.

5 Restore the previously noted DSW2 DIP switch settings and press the RESET button SW2.

Switch Setting

Function 8 7 6 5 4 3 2 1

Black Mark Calibration 0 0 0 1 0 1 0 1

Error condition LED 1 LED 2 LED 3 LED 4

Paper out off off BLINKS BLINKS

Black mark too wide or not found BLINKS off off BLINKS

Unable to calibrate (unknown error) BLINKS off BLINKS BLINKS

10-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 191: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

6 To confirm a successful calibration, press the RESET button and then immediately press and hold the paper feed button. The printer will produce a configuration printout, for example:

Check the Sensor level ON and OFF values: if they are both “0000” then the calibration was not successful and the EEPROM data was not changed.

Dot-Matrix Journal Printer 10

The illustration below shows a dot-matrix journal printer fitted on the printer tray along with a thermal receipt printer.

The thermal receipt printer, if fitted, is configured as described in the previous section.

<Receipt printer>

F/W ROM version 1.60ANK CG version 1.00

Sensor level

ON OFF THBDS 0772 0143 0457

- DIP switches -1 = Black mark mode2 = 5670 emulation

3 = Receipt printer

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-9

Page 192: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

Character Set Selection 10

The Dot-Matrix printer is configured using an 8-pole switch pack:

● Switch 7 selects the Character Set – OFF to select International character set or ON to select the Arabic character set

● Switches 1 to 6 and 8 are not used.

The printer is delivered with all switches OFF (International character set selected).

10-10 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 193: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

80-Column Printer Configuration 10

The ATM may be fitted with one of two variants of the 80-column printer:

● Statement printer (Letter Quality Document)● Parallel Port or “Open” Statement printer (Letter Quality

Document)

For each variant, some configuration is required.

Note: Prior to the ATM’s dispatch from the factory, the statement capture bin threshold is configured to a setting of 10 (or 6 for buncher). Details on how to change these thresholds can be found in the NCR publication, “APTRA Self-Service Support, System Application User Guide”, B006-6167 or “Self-Service Terminal Supervisor Functions”, B006-4718 depending on your system software.

Letter Quality Document (LQD) Printers 10

The printer leaves the factory with paper width set to 216mm (8.5in.) and paper length set to 305mm (12in.).

If the paper width or length setting requires to be changed, the switch settings (width) or the paper guides (width and length) should be adjusted. These tasks must be performed by a customer engineer.

Note: If you have a Parallel Port or “Open” variant of the Statement printer, proceed to beyond the next section, as there is no requirement to adjust the switch settings.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-11

Page 194: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

Adjusting DIP Switch Settings 10

You need to adjust the DIP switch settings on the main pcb (on switch pack U63) to fit the size of paper to be used on it. The following table provides the appropriate width settings for various sizes of paper (the default width setting is 216 mm (8.5 in.)). When choosing a width setting, select the nearest width up from your paper size. For example, choose the 148 mm (5.82 in.) setting for paper width of 147.5 mm (5.81 in.).

Note: 1 = On, 0 = Off, x = Don’t care.

Paper Width Switch Setting

mm Inches 8 7 6 5 4 3 2 1

216 8.50 x 0 0 0 0 0 0 0

215 8.47 x 0 0 0 0 0 0 1

214 8.41 x 0 0 0 0 0 1 0

212 8.34 x 0 0 0 0 0 1 1

210 8.28 x 0 0 0 0 1 0 0

209 8.21 x 0 0 0 0 1 0 1

207 8.14 x 0 0 0 0 1 1 0

205 8.08 x 0 0 0 0 1 1 1

203 8.01 x 0 0 0 1 0 0 0

202 7.94 x 0 0 0 1 0 0 1

200 7.88 x 0 0 0 1 0 1 0

198 7.81 x 0 0 0 1 0 1 1

197 7.74 x 0 0 0 1 1 0 0

195 7.68 x 0 0 0 1 1 0 1

193 7.61 x 0 0 0 1 1 1 0

192 7.55 x 0 0 0 1 1 1 1

190 7.48 x 0 0 1 0 0 0 0

188 7.41 x 0 0 1 0 0 0 1

187 7.35 x 0 0 1 0 0 1 0

185 7.28 x 0 0 1 0 0 1 1

183 7.21 x 0 0 1 0 1 0 0

182 7.15 x 0 0 1 0 1 0 1

10-12 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 195: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

180 7.08 x 0 0 1 0 1 1 0

178 7.01 x 0 0 1 0 1 1 1

176 6.95 x 0 0 1 1 0 0 0

175 6.88 x 0 0 1 1 0 0 1

173 6.81 x 0 0 1 1 0 1 0

171 6.75 x 0 0 1 1 0 1 1

170 6.68 x 0 0 1 1 1 0 0

168 6.62 x 0 0 1 1 1 0 1

166 6.55 x 0 0 1 1 1 1 0

165 6.48 x 0 0 1 1 1 1 1

163 6.42 x 0 1 0 0 0 0 0

161 6.35 x 0 1 0 0 0 0 1

160 6.28 x 0 1 0 0 0 1 0

158 6.22 x 0 1 0 0 0 1 1

156 6.15 x 0 1 0 0 1 0 0

155 6.08 x 0 1 0 0 1 0 1

153 6.02 x 0 1 0 0 1 1 0

151 5.95 x 0 1 0 0 1 1 1

149 5.89 x 0 1 0 1 0 0 0

148 5.82 x 0 1 0 1 0 0 1

146 5.75 x 0 1 0 1 0 1 0

144 5.69 x 0 1 0 1 0 1 1

143 5.62 x 0 1 0 1 1 0 0

141 5.55 x 0 1 0 1 1 0 1

139 5.49 x 0 1 0 1 1 1 0

Paper Width Switch Setting

mm Inches 8 7 6 5 4 3 2 1

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-13

Page 196: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

Adjusting The LQD Printer Paper Hopper 10

To adjust the paper hopper:

1 Open the top-box of your ATM.

2 If your ATM does not have the auto-supervisor function, press the switch on the operator panel to the supervisor position.

3 Press the green latch and pull the printer out of the ATM until its slides are fully extended.

4 Lift the latch at the side of the hopper and slide the hopper out.

1

2

10-14 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 197: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

5 To change the hopper width, slide one of the paper guides to the left or the right in its slot. This automatically moves the facing guide an equal distance in the opposite direction. Adjust the space between the guides to the required width.

Note: The guides are centrally located so any adjustment automatically centres paper placement in the hopper.

6 To change the hopper length, move the single guide backward or forward in its slot to set the required length.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-15

Page 198: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

7 Place the paper stack in the hopper. The paper stack must be high enough to flatten the paper low sensor.

Note: Place the paper in the tray so that the black dot faces upwards and will be on the underside and towards the top edge of the form as it feeds into the printer.

8 Adjust the guides in the hopper to fit the paper stack.

9 Slide the hopper forwards to its operating position.

10-16 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 199: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

10 Loosen the thumbscrew which secures the top paper guides and then slide the guides apart.

11 Place the paper between the guides. Move either guide towards the edge of the paper. This will cause the other guide to move the same corresponding distance. Ensure that there is 0.5 mm (0.02 in.) clearance at each side of the paper.

12 Tighten the thumbscrew.

2

1

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-17

Page 200: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

13 Hold the paper in place between the guides and press the paper feed switch. The paper should feed through the printer.

14 Remove the statement from the printer transport.

15 Push the printer back into the ATM until it clicks into place.

16 Press the switch on the operator panel to the normal position.

17 Close and lock the top-box.

Adjusting The Contrast 10

On a LQD printer, you may need to change the contrast control to obtain better image clarity when printing. To do this, adjust the contrast control switch or, if the printer does not have a contrast control switch, an Installation Engineer can adjust the printer contrast using the User Switches (U64) on the printer control board.

Contrast Control Switch 10

The contrast control switch (located on the paper guide assembly) allows you to adjust the printer contrast.

10-18 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 201: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

The location of the contrast control switch is shown below:

To darken the image, set the switch to the Down position. The contrast is increased by applying more heat to the paper, however, if the image is too dark, the print may blur slightly.

To lighten the image, set the contrast switch to the Up position. If the contrast is too light, the print image may fade over time.

Paper Load/UnloadSwitch

ContrastControlSwitch

PaperGuide

Assembly

ContrastControl Switch

Paper GuideAssembly

Dark

Light

Normal

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 10-19

Page 202: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

User Switches (U64) 10

Note: The following procedure should only be carried out by a suitably qualified Installation Engineer, if the printer does not have a contrast control switch.

To access the control board, remove the safety cover. Reset SW1 and SW2 on User Switches (U64) as follows:

Note: 0 = off, 1 = ON.

The default setting for all paper (unless specified otherwise) is MEDIUM. If the media specifications state that any grade of paper requires increased contrast setting, then use the DARK setting.

Note: The image can be lightened or darkened by adjusting SW1 and SW2. To darken the image, the contrast must be increased (more heat is applied to the paper). However, if the contrast is too dark, this can cause the end image to blur slightly. If the contrast is too light, this can cause the end image to fade over time.

SW1 SW2

LIGHT 0 1

MEDIUM 0 0 factory setting

DARK 1 0

10-20 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 203: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsFitting Decals To The ATM

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Chapter 11

Fitting Decals To The ATM

Fitting The Decals 11-1Advert Light 11-1Card Orientation Window And Clear Window 11-1Entry/Exit Decals 11-2Card Acceptance Decal 11-2

Page 204: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsFitting Decals To The ATM

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 205: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation 11

-1

Fitting The DecalsFitting Decals To The ATM11

Fitting The Decals 11

This chapter describes how to fit decals to the front of the ATM. Specifications for the decals can be found in Chapter 4.

Decals are fitted to the facia of the 5887 Drive-Up ATMs as follows:

Advert Light 11

If fitting a decal to the outside of the advert light panel, make sure that the panel is clean and dry before applying the decal.

Card Orientation Window And Clear Window 11

To fit a decal behind the card orientation plastic window or the larger clear window, proceed as follows:

1 Insert the two window extraction tools (supplied with the ATM) into the holes at the base of the window.

Card

Cash

Receipt

Statement

CardOrientation

Advert Light

Page 206: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Fitting Decals To The ATMFitting The Decals

2 Push down on the two extraction tools to release the window’s catches, then pull the window out from the facia.

3 Place the decal in position and then press the plastic window back into the facia.

Entry/Exit Decals 11

The facia of the ATM has been provided with recesses for self-adhesive decals to identify the entry and exit slots. Make sure that the surface is clean and dry and then apply the correct decal firmly.

Card Acceptance Decal 11

Position this decal onto the side panel at the right hand side of the facia. Make sure that the surface is clean and dry and then apply the decal firmly.

11-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 207: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsTransient And Power Protection

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Appendix A

Transient And Power Protection

AC Power Line Transient Protection A-1

Data Line Transient Protection A-3

NCR Power Protection and Cabling Products A-4AC Power Line Transient Protection A-4Data Line Transient Protection A-5Uninterruptible Power Supplies A-5Contact Information A-7

Page 208: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsTransient And Power Protection

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 209: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation A

-1

AC Power Line Transient ProtectionTransient And Power ProtectionA

AC Power Line Transient Protection A

In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced on to power lines. Such transient energy can be very damaging to electronic hardware and can also cause data corruption. Under these circumstances, NCR recommends the use of ac power transient suppressors and data (communication) line transient suppressors. Such protective devices are intended to guard against power and data line transients that can result in hardware damage and various system or program errors.

Improvement of any deficiencies in power quality is a customer responsibility. Malfunction and/or component failure as a result of power quality problems are/is not covered by NCR Maintenance Agreement, NCR accepts no liability for any such occurrence nor for its consequences.

When power transient suppression is required, the suppressors used should meet the following minimum requirements:

● Dissipate energy to match the appropriate application categories as defined by IEEE Standard 587. These categories are described in the table below:

Location Category

Comparableto IECNo 664Category

Transient

Waveform Amplitudes

A=Outlets > 10 m (30 ft)from Cat. BA= Outlets > 20 m (60 ft) from Cat. C

II 0.5 s Risetime, then 100 kHzRingwave, eachpeak=60% of previous

6 kV

200A

B=Major feeders, short branch circuits, and load centres

III Volts=1.3 x 5 sCurrent= 8 x 20 sand0.5 s Rise = 100 kHz Ringwave

6kV3kA

6kV500A

C = Service Entrance and run to load centre

IV Volts = 1.2 x 5 s

Current = 8 x 20 s

10kV or more

10kA or more

µ

µµ

µ

µ

µ

Page 210: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionAC Power Line Transient Protection

● Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not ‘clamp’ the voltage to zero, and must self-recover after passage of the transient. The suppressor may be of the hybrid type construction that makes use of various technologies in order to meet speed and dissipation requirements.

● Exhibit a ‘short circuit’ mode upon its failure, thus providing a positive indication of its failure such as a blown fuse or tripped breaker

● Be listed by the accepted safety organization for the country involved (e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local, state, and national electrical codes and regulations.

A-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 211: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionData Line Transient Protection

Data Line Transient Protection A

The nature of the transient phenomenon may extend to the data communication lines connected to this equipment. It is the responsibility of the customer to install and connect a data line transient suppression system to correct or prevent any deficiencies. Such systems must meet the following minimum requirements:

● Be of the voltage limiting type and must self-recover after passage of the transient

● Exhibit a ‘short circuit’ mode upon its failure to insure a positive indication of its failure

● Insert less than 5 ohms resistance and minimal inductive and capacitive loading at the operating frequency, in each data line in order to avoid signal degradation

● Be installed in accordance with all applicable local, state, and national electrical codes and regulations.

Note: In certain countries, NCR is able to supply both power and data line transient suppressors as well as a comprehensive line of power conditioning equipment. For application data, contact your NCR Customer Services Division Representative.

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation A-3

Page 212: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionNCR Power Protection and Cabling Products

NCR Power Protection and Cabling Products A

Power protection equipment suitable for use with NCR ATMs can be purchased from the NCR Power Protection and Cabling group. Some of these products are outlined below.

AC Power Line Transient Protection A

The following products can be purchased from the NCR Power Protection and Cabling group to help provide protection from power line spikes and surges:

These products have numerous features:

● unique five-stage hybrid circuitry● offers protection from spikes and surges● protection covers all modes - line to neutral, line to earth

(ground) and neutral to earth (ground)● integral RF/EMI damping capability● thermal overload protection● high capacity fusing● indicator lights display operational readiness● plastic housing is highly flame retardant, conforming to UL94-

5V.

NCR Product ID Description

4060-4030-0094 110V, 3 outlet, wall plug-in, 15 Amp suppressor, United States applications

4060-4050-0094 110V, 3 outlet, strip, 15 Amp suppressor with 1.8 metres (6 feet) of power cable, United States applications

4060-4070-0094 110V, 7 outlet, strip, 15 Amp suppressor with 1.8 metres (6 feet) of power cable, United States applications

4060-4310-7594 220V, 4 outlet, strip, United Kingdom plug fitted

4060-4311-7594 220V, 4 outlet, strip, German/European plug fitted

4060-4312-7594 220V, 4 outlet, strip, French plug fitted

A-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 213: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionNCR Power Protection and Cabling Products

Data Line Transient Protection A

The following Data Line Transient Voltage Surge Suppressors can be purchased from the NCR Power Protection and Cabling group to help protect the communications port against harmful transient surges from both external and internal sources not eliminated by Uninterruptible Power Supplies or other AC protection:

Note: The first two products are designed to snap-in to the interface port on NCR Series 4000 Transient Voltage Surge Suppressors in the United States. The second two products are designed to be stand-alone for use in Europe.

Uninterruptible Power Supplies A

Uninterruptible Power Supplies (UPS) can be purchased from the NCR Power Protection and Cabling group to help protect information and equipment by providing power conditioning and battery back-up.

These products offer:

● on-line topology● 10 minute battery backup at full load● true sine wave output● 100% clean, conditioned power to connected equipment● extended battery cabinets available for extended run times● on-board SNMP optional on all models● standard LAN/serial (RS-232) network interface● standard rack-mountable unit design● also available in 1500 VA, 2100 VA and 3000 VA sizes.

NCR Product ID Description

4060-K018-V000 25 pin, CMP, snaps in to United States surge suppressors

4060-K019-V000 25 pin, CFP, snaps in to United States surge suppressors

4060-K021-V000 25 pin, CMP, stand-alone, all applications

4060-K022-V000 25 pin, CFP, stand-alone, all applications

NCR Product ID Description

4084-1000-7194 1000 VA on-line UPS with rack/tower configuration, 120VAC 50/60 Hz

4084-1000-7494 1000 VA on-line UPS with rack/tower configuration, 230VAC 50/60 Hz

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation A-5

Page 214: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionNCR Power Protection and Cabling Products

These products offer:

● line-interactive topology● 8 minute battery backup at full load● true sine wave output● input voltage selectable to 110/127 VAC or

220/240 VAC● advanced battery management prolongs battery life and ensures

quick availability after discharge● advanced battery management for early failure detection and

advanced user warning● internal transformer provides voltage buck/boost● standard LAN/serial (RS-232) network interface● available in rack-mountable configuration● also available in 600VA, 1500VA, 2000VA, 2200VA sizes.

NCR Product ID Description

4071-1000-7194 1000 VA Enhanced line-interactive UPS, 120VAC 60 Hz

4071-1001-7194 1000 VA Enhanced line-interactive UPS, 120VAC 60 Hz, Rack-mountable

4071-1000-7494 1000 V A Enhanced line-interactive UPS, 230 VAC, 50/60 Hz

4071-1001-7494 1000 V A Enhanced line-interactive UPS, 230 VAC, 50/60 Hz, Rack-mountable

A-6 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 215: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionNCR Power Protection and Cabling Products

These products offer:

● line-interactive topology● 7 minute battery backup at full load● modified sine wave output● input voltage selectable at 110/127 VAC or

220/240 VAC● advanced battery management prolongs battery like and

ensures quick availability after discharge● advanced battery management for early failure detection and

advanced user warning● internal transformer provides voltage buck/boost● standard LAN/serial (RS-232) network interface● hot-swappable batteries● also available in 450 VA, 700 VA, 1500 VA sizes.

Contact Information A

For more information from NCR’s Power Protection and Cabling Group on the power protection, data line transient suppressors and uninterruptible power supply products available, warranty or configuration assistance, call the appropriate number below:

NCR Product ID Description

4070-1000-7194 1000 VA Line-interactive UPS, 120AC, 60 Hz

4071-1000-7494 1000 VA Line-interactive UPS, 230VAC, 50/60 Hz

Telephone

Worldwide (excl. USA) +1 919 460 9489

USA only 1 800 257 0458

Facsimile

Worldwide +1 919 460 9653 or+1 919 460 8976

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation A-7

Page 216: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient And Power ProtectionNCR Power Protection and Cabling Products

A-8 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 217: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

-1Index

Index 0

Numerics40-Column Printer Configuration 10-580-Column Printer Configuration 10-11

AAC Power Line Transient Protection A-1AC Power Requirements 2-1Adjustable Plinth 1-21Air Flow 3-3Alarm Interface Cable 2-10Ambient Lighting 1-7Anchor Bolts 1-23ATM Dimensions 1-3

Before Collar Has Been Fitted 1-3Heights And Depth To Main Facia Items 1-6Severe Environment Fitted 1-5Standard Collar 1-4Standard Collar With Advert Light 1-4

ATM Installed Directly On To The Floor 1-21

BBarometric Pressure 3-2

CCables

High Order Communications Cable 2-4Power Cable 2-2Remote Device Cables 2-6

Combination Lock And Separate Keylock 7-9Combination Locks 7-7Communications Configuration 10-4Communications Requirements 2-4Concrete Plinth 1-21Configuring the ATM

40-Column Printer 10-580-Column Printer 10-11Communications

APTRA Self-Service Support 10-4S4I 10-4

Currency Cassette 10-2Device 10-3

Connecting CablesAll Other Cables 9-17Power Cable 9-15

Connecting Cables To The ATM 9-12Controlled Access Electronic Lock 7-16Currency Cassette Configuration 10-2Customer Responsibilities v-xviCustomer Setting Combination 7-8, 7-11

Page 218: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

DData Line Transient Protection A-3Decal Dimensions

Advert Light 4-3Card Orientation Window 4-2Clear Window 4-3Entry/Exit Slot Decals 4-4

Decal Specifications 4-1Device Configuration 10-3Dimensions

Ambient Lighting 1-7Before Collar Has Been Fitted 1-3Height And Depth To Main Facia Items 1-6Severe Environment Fitted 1-5Standard Collar 1-4Standard Collar With Advert Light 1-4

EElectromagnetic Compatibility (EMC) And Safety 3-3Electronic Lock

Emergency Opening Procedure 7-15Not Working 7-14

EMI Emission 2-3EMI Susceptibility 2-3

FFactory Setting 7-8Fitting A Third Party Video Camera 1-25Fitting An Infill Panel 8-25Fitting The Collar

Standard Collar With Advert Light 8-33Standard Collar With Facia Light 8-28

Fitting The Decals 11-1Fitting The Severe Environment Parts 8-2Floor Covering 1-23Floor Loading 1-22

GGrounding Requirements 2-2

HHeat Dissipation 3-3Height And Depth To Main Facia Items 1-6High Order Communications Cable

Standard Cable (RS-232) 2-15High Order Communications Cable, Standard Cable (RS-232) 2-4Hole In The Wall

Installation Categories 1-14Installing Through A Glass Wall 1-14Installing Through A New Hole 1-17Replacing 5088 With Modifications To Hole In Wall 1-15Replacing 5688 With No Modifications To Hole In Wall 1-16Sealing 1-18

How To Change The Combination Lock 7-9, 7-12How To Lock A Keylock 7-7

Index-2 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 219: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

How To Lock The Combination Lock 7-9, 7-12How To Operate The Silent Alarm 7-9How To Unlock A Keylock 7-7How To Unlock And Lock

Combination Locks 7-7Keylocks 7-7

IInfill Panel Dimensions

Infill Panel (5088) 1-24Infill Panel (5688) 1-24

Input Voltage Setting 2-1Inspecting The ATM For Damage 7-1Installation Accessories 5-1Installation And Service Clearances

Exterior WallStandard Collar 1-12Standard Collar With Advert Light 1-12

Minimum Clearances 1-10Recommended Clearances 1-8

Installation Planning Check List 5-2Installation Procedure 6-1Installation Report Form 7-2Installing A Video Camera 1-25Installing Through A New Hole 1-17Internal Packaging, Removing 9-1

LLocking

Locking a sub-lock 7-20Locks

Combination Lock And Separate Keylock 7-9Combination Locks 7-7Keylocks 7-7

MMandatory Modifications To Plinth Or Floor

Adjustable Plinth 1-21ATM Installed Directly On To The Floor 1-21Concrete Plinth 1-21Floor Loading 1-22

Manoeuvring The ATM Into Position 1-2Module Locations 9-1

OOverview v-xv

PPackage Dimensions 1-1Planning Check List 5-2Positioning The ATM 8-24Power Cable 2-2Power Consumption 2-1Product Identification v-xvii

NCR Personas M Series 5887 Drive-Up Site Preparation And Installation Index-3

Page 220: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

RRemote Device Cables

Alarm Interface Cable 2-10Remote Relay Cable 2-12Remote Status Monitor 2-8RS-232 Cable 2-6–2-7, 2-15

Removing The External Packaging 7-1Removing The Internal Packaging 9-1Replacing 5088 With Modifications To Hole In Wall 1-15Replacing 5688 With No Modifications To Hole In Wall 1-16Requirements For The Floor

Support Plinth 1-19

SSealing The Collar And Bolting The ATM To The Plinth 8-40Sealing The Hole In The Wall 1-18Security Bolts 1-23Service Access Panels 1-13Service Clearances

Exterior WallStandard Collar 1-12Standard Collar With Advert Light 1-12

Minimum Clearances 1-10Recommended Clearances 1-8

Silent Alarm 7-14Standard Collar With Advert Light 1-12Standard Security Enclosure 7-6Sub-lock

Locking 7-20Unlocking 7-19

Support Plinth 1-19

TTemperature And Humidity 3-1Temperature Rise 3-3Transient Protection A-1

UUnlocking And Locking

A Combination Lock and Separate Keylock 7-9A Controlled Access Electronic Lock 7-16A Standard Security Enclosure 7-6A sub-lock 7-19An Electronic Lock 7-13

VVideo Camera 1-25

Index-4 NCR Personas M Series 5887 Drive-Up Site Preparation And Installation

Page 221: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Title:

Number:

NCR welcimprove o

You may

Circle the

Ease of us

Accuracy

Clarity

Complete

Organizat

Appearan

Examples

Illustratio

Job perfor

Question

Overall sa

Indicate th

❑ Impr

❑ Impr

❑ Impr

❑ Impr

❑ Make

❑ Make

Cut

User Feedback Form

NCR Personas M Series 5887 Site Preparation And Installation

ate:

B006-6356-C000

omes your feedback on this publication. Youur information products.

send your comments to us electronically. Se

numbers below that best represent your opi

e 5 4 3 2 1 0

5 4 3 2 1 0

5 4 3 2 1 0

ness 5 4 3 2 1 0

ion 5 4 3 2 1 0

ce 5 4 3 2 1 0

5 4 3 2 1 0

ns 5 4 3 2 1 0

mance 5 4 3 2 1 0

resolution 5 4 3 2 1 0

tisfaction 5 4 3 2 1 0

e ways you feel we could improve this publ

ove the table of contents ❑ A

ove the overview/introduction ❑ A

ove the organization ❑ A

ove the index ❑ A

it less technical ❑ A

it more concise/brief ❑ A

D

r comments can be of great v

e over for details.

nion of this publication.

5 = Excellent4 = Good3 = Adequate2 = Fair1 = Poor

0 = Not applicable

ication.

dd more/better quick referen

dd more examples

dd more illustrations

dd more step-by-step proced

dd more troubleshooting inf

dd more detail

1204

alue in helping us

ce aids

ures

ormation

Page 222: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5887 Drive-Up Site Preparation And Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Fold

Fold

Cut

AffixPostageStampHere

Write any additional comments you may have below and on additional sheets, if necessary. Include page numbers where applicable.

Use the following addresses to send your comments to us electronically:

e-mail - [email protected]

If we may contact you concerning your comments, please fill in the information below:

Thank you for your evaluation of this publication. Fold the form where indicated, tape (please do not staple),and drop in the mail.

F 8763-0695

Name:

Organization:

Company:

Address:

Phone: Fax: