muone calorimeters muone feasibility test @ compass mattia soldani 1 · 2018. 7. 13. · stefi (run...

8
MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 1 from to ASCII calorimeter 04/04 (the beginning) 01/05 300118-300198 DEVA 02/05 22/05 300232-300280 STEFI 23/05 07/06 300290-300304 none (tb @ T9) 08/06 ... from 300320 on GENNI ?

Upload: others

Post on 22-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

MUonE CALORIMETERSMUonE feasibility test @ COMPASS

Mattia Soldanijul 2018

1

from to ASCII calorimeter

04/04(the beginning) 01/05 300118-300198 DEVA

02/05 22/05 300232-300280 STEFI

23/05 07/06 300290-300304 none(tb @ T9)

08/06 ... from 300320 on GENNI

?

Page 2: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

DEVA (run 300118 to 300198) MUonE feasibility test @ COMPASSMattia Soldani

jul 20182● sampling: Pb & plastic scintillator

● longitudinal segmentation: 12 active layers (all 2cm thick) & 11 absorbers (the 3 downstream are 1cm thick, the other 8 are 0.5cm thick) → 13X0 in total

● transverse area: 15x15cm2

● output: optical fibers → MAPMT (HAMAMATSU R5600-M16 16 anode)● 12 single layer channels → in the MUonE setup layers are organized

into 8 channels this way:

DIGI1 - CH1-8

1 DEVA 1

2 DEVA 2

3 DEVA 3

4 DEVA 4

5 DEVA 5+6

6 DEVA 7+8

7 DEVA 9+10

8 DEVA 11+12

1 2 3 4 5 6 7 8 9 10 11 12

Page 3: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASSMattia Soldani

jul 20183● 3x3 matrix of 9 CMS endcap PbWO4 crystals, each:

⇒ 2.86cm side @ front & 2.96cm side @ rear⇒ 22cm long → ~24.7 X0 in total

● Al & plastic mechanical structure● few mm between channels

→ need for tilteddisplacement inside his box

● each crystal is coupledto a PMT(HAMAMATSU H6780-03)

● each channel readout individually, in this order:

10 2

43 5

76 8ceiling

floor

Jura

Salè

ve

z (beam)

DIGI1 - CH1-8

1 STEFI 0

2 STEFI 1

3 STEFI 2

4 STEFI 3

5 STEFI 4

6 STEFI 5

7 STEFI 6

8 STEFI 7

DIGI2 - CH9-16

9 STEFI 8

Page 4: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASSMattia Soldani

jul 20184

Page 5: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

Some preliminary check from MUonE setup is already available...

STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASSMattia Soldani

jul 20185

Page 6: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

GENNI (from run 300320 on) MUonE feasibility test @ COMPASSMattia Soldani

jul 20186● new detector w/ 9 PADME ECAL BGO painted crystals (recovered from L3 EM endcap)

⇒ ~2.1cm side @ front⇒ ~23cm long → ~20.5 X0 in total

● metal & plastic mechanical structure which holds crystals together (little blind space between channels!) in a 3x3 matrix and couples each channel with a PMT → everything contained in a box

● performance under study at the moment… → it seems to have very good energy resolution!

● channels order in ASCII files is the same as STEFI(see slide 3)

Page 7: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

OUTLINE MUonE feasibility test @ COMPASSMattia Soldani

jul 20187

energy scans in the range (0.5,9)GeV were performed for all the three detectors during the INSULAb test which took place at the beginning of June at T9 (beam of electrons, muons

and pions mainly)

data are being analyzed for equalization, calibration and performance evaluation...

Page 8: MUonE CALORIMETERS MUonE feasibility test @ COMPASS Mattia Soldani 1 · 2018. 7. 13. · STEFI (run 300232 to 300280) MUonE feasibility test @ COMPASS Mattia Soldani jul 2018 3 3x3

Thank you!