MR050B SERIES DEHYDRATOR

USER MANUAL

Bulletin AE01B-A0553-001 Rev: M © 2009 - 2012 CommScope, Inc. All rights reserved (04/12)

MR050B SERIES DEHYDRATOR USER MANUAL

2

Section 1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.3 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.4 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Figure 1 Summary Alarm Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Figure 2 Discrete Alarm Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Figure 3 Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51.5 SpecificationsMR050BDehydrator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Section 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62.2 Controls and Displays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62.3 InstallingtheDehydrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62.3.1 19”RackMountingorsetonshelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62.4 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62.4.2 Safety Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72.4.3 TesttheDehydrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72.5 ConnectingtheAlarmOutputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72.6 ConnectingDehydratortotheTransmissionLine. . . . . . . . . . . . . . . . . . . . . . . . . . .72.7 PurgingtheTransmissionLine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Section 3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83.0 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.1 Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.2 Desiccant Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.3 Annual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.4 Checktheelectricalconnections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.5 Checkthedutycycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.6 Parts Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.7 UnitShutdownandRemoval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83.8 Service Restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Section 4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Problem/Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Figure 4 MR050B-31015 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 5 MR050B-31215 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 6 Pneumatic Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Section 5 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Desiccant Kit MR050B-KIT-DSCNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Compressor Kit MR050B-KIT-CPRSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Section 6 Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146.0 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146.1 In Case of Trouble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146.2 Initial Steps by CommScope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156.3 Repair Center Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Table Contents

MR050B SERIES DEHYDRATOR USER MANUAL

3

1 .1 Introduction

Thismanualcontainstheinformationyouneedto install, operate, and maintain your MR050B Seriesdehydrator.Pleasetakethetimetoreadthismanualbeforeattemptingtooperateorservicetheunit.

This appliance is not intended for access by the general public .

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety .

1 .2 Description

MR050BSeriesdehydratorsprovidedryairforpressurizing small (up to 280 liters, or 10 cubic feet, in volume) antenna and transmission line systems.Thedehydratorsproduce-40ºC(-40ºF)dew point dry air at a nominal rate of 1.4 liters (0.05 cubic feet) per minute up to a total of 8495 Iiters (300 cubic feet) on a single desiccant canister.

Eachdehydratorconsistsofanelectrically-driven air compressor, a desiccant canister, an automatic transmission line pressure sensing system,andalarmoutputshousedinarigidmetalchassis.Itisdesignedtomountdirectlytotherack,directlyonawall,orasafree-standingunit.Thefrontpanelfeaturesacontrolinterfacewithdisplayforalarmsandpressure.Foreasyserviceability, power connections, alarm output connections,andthedesiccantcanisterareeasilyaccessiblefromthefrontoftheunit.

TheMR050Bmaintainstransmissionline

pressures between 2.0 and 3.4 kPa (0.3 and 0.5psig).Itisintendedforusewithhighperformancemicrowaveantennasandearthstation antennas.

1 .3 Operation

MR050Bseriesdehydratorsincludeacompressor,colorindicatingdesiccant,highandlow-pressure sensors, and a low-pressure alarm sensor.

Whensystempressurefallstoapresetlowlimit,thelow-pressuresensoractivatesthecompressor.Airischanneledthroughadesiccantcanister,wheremoistureisadsorbed.Theairexitsthedryingcanisterat-40°C(-40°F)dewpoint.Itisthenchanneleddirectlytoaninternal 4-port manifold.Whensystempressurereachesapresethighlimit,thehigh-pressuresensorshutsoffthecompressor.Acheckvalvepreventssystemdryairfromretreatingbackthroughthecompressor.

Ifsystempressurefallssignificantlybelowthelow-pressuretriggerpoint,thelow-pressurealarm sensor will activate an alarm contact. Thisalarmisanindicationofasignificantsystemleakoradehydratorfailure.

1 .4 Alarms

TheMR050BoffersLowPressureandExcessRun alarms as a standard feature. Indicated onasummaryalarmconnection.ThediscretealarmoptionincludesLowPressure,ExcessRunandPowerFailalarmswhichreportthroughdiscretecontacts.Alarmconditionsareindicatedonthedisplay.ThealarmsareFormCdrycontactsandhaveconnectionoptionsforNormally Open (NO) or Normally Closed (NC) configuration.

Theexternalalarmmonitoringsystem(suppliedbyothers)isconnectedtotheterminalstriplocatedonthefrontoftheunit.Asmallslottedscrewdriverisnecessarytomaketheconnections.

Refer to Figure 1 and 2 for correct locations and colorsofthewiresonthealarmterminalstrip.

Section 1General Information

MR050B SERIES DEHYDRATOR USER MANUAL

4

Alarm Definitions:

Summary: ActivateswhentheHighPressure(only indicated on summary contacts),ExcessRun,and/orLowPressurealarmsaretriggered.Thesummary alarm does not report Power Fail.

Power Fail: Activatesopenwhenpowerisremovedfromthedehydrator.Thisincludesturningthepoweroffattheswitch.

Excess Run: Factory strapped run time set in accordancewiththenormalruntimeforthedehydratorapplication.Selectable times are 1, 10, 30, 120 and240minutes,withthe10minuteselectionusedontheMR050Basthedefaultsetting.

Low Pressure: Ifsystempressurefallsbelowthelow-pressure trigger point (factory setontheMR050B),thelow-pressure alarm sensor will activate analarmcontact.Thisalarmisanindicationofasignificantsystemleakoradehydratorfailure.

Figure 1 Summary Alarm Terminal

Note: All of the alarms clear and reset automatically, but can be manually reset in the display menus . However, if the alarm condition still exists, the alarm will return immediately after being reset .

WIRE FUNCTION REFERNCEWIRE

TERMINAL COLOR ALARMFUNCTION

1 WHITE EXCESS RUN NO2 TAN EXCESS RUN COM3 BLUE EXCESS RUN NC4 BROWN SUM NO5 PINK SUM COM6 GREEN SUM NC7 BLACK POWERFAILNO8 VIOLET POWERFAILCOM9 RED POWERFAILNC10 ORANGE LOWPRESSURENO11 YELLOW LOWPRESSURECOM12 GRAY LOWPRESSURENC

WIRE FUNCTION REFERNCEWIRE

TERMINAL COLOR ALARMFUNCTION

1 BLACK SUMMARY NC2 WHITE SUMMARY COM3 RED SUMMARY NO

BLACK

RED

WHITE

WHITE

GREENPINKBROWNBLUETAN

BLACK

VIOLET

REDORANGEYELLOWGRAY

Figure 2 Discrete Alarm Terminal

MR050B SERIES DEHYDRATOR USER MANUAL

5

1.5 Specifications MR050B Dehydrator

Cut Out Pressure, kPa (psig) 3.5 (0.5)

Cut In Pressure, kPa (psig) 2 (0.3)

Outputcapacity 85SLPH,1.4SLPM (3.0SCFH;0.05SCFM) (total,approx.)

OutputDewPoint, -36°C(-33°F) or better

OperatingTemperature 1°to+40°CRange (34°to+104°F)

Electrical Input 24/48 Vdc 115/240Vac,50/60Hz (withac-to-dcadapter)

Power Consumption 11 watts continuous

Output Connectors 3/8” polytube, compression

Dimensions Height,cm(in) 13.2(5.2) Width,cm(in) 43.9(17.3) Depth,cm(in) 20.3(8.0)

Netweight,kg(lb) 7.26 (16)

Alarms

Power Fail Alarm loss of input power

ExcessRunAlarm 10minutes,factoryset

LowPressureAlarm factoryset

HighPressureAlarm factoryset

Figure 3 Control Board

NOT IN USE

48 Vac COMP OUTPUTP7

(MR050B ONLY)

SUM ALARMP8

(NO/NC)

KEYPADJ4

DISCRETE ALARMSP9

115 Vac COMP

OUTPUTP4

(MT/PMT SERIES)

Vdc INPUTP2

(MR050B ONLY)

LOW PRESSURE SENSOR

U4

HIGH PRESSURE SENSOR

U2

USBP1

SOLENOID(FILTER DRAIN

MT/PMT SERIES)

P6

AC MAIN

[

[

MR050B SERIES DEHYDRATOR USER MANUAL

6

Section 2 Installation2 .1 Unpacking and Inspection

Open Carton

Removethetoppieceoffoampackaging.Carefullyremovetheinstallationaccessories,manual,anddehydrator.Checkthedehydratorforshippingdamagesuchasdentsorlooseparts.

2 .2 Controls and DisplaysDefault password is 1111

Familiarizeyourselfwiththecontrolsanddisplayspriortoinstallingortestingthedehydrator.

Keypad Controls:

Advancesdisplay(scrollsahead)tothenextdisplayorprogrammodewithoutchangingthevaluesinthemicroprocessormemory.

Numerically increase displayed settings in displaywindow.Whendepressedlongerthan1/2secondscrollingwilloccuratafaster rate.

Numerically decrease displayed settings indisplaywindow.Whendepressedlongerthan1/2secondscrollingwilloccurat a faster rate.

Entersintothemicroprocessormemorythevaluesdisplayedinthewindowandadvancesdisplay(scrollsahead)tothenextprogramordisplaymode.

Usedtoallowtheuserquickaccesstothesystem event log.

2 .3 Installing the Dehydrator

2 .3 .1 19” Rack Mounting or set on shelf

MR050Bcanbemountedinstandard19inchequipmentrack,mountedtoawallwithear’sorplacedonanoptionalshelf.

2 .4 Power Connections

Confirmyourdehydratorelectricalinputmatchestheavailablepower.

Ensure an electrical safety ground is installed on thegroundstudlocatedadjacenttothepowerinput connector. (It is intended to be customer installedinthefieldtoyourhalogroundingsystem.)

115Vav60Hz/240Vac50Hz 24 Vdc/48 Vdc

2 .4 .1 AC Power

AC units can be connected into a standard 15 Amppowerreceptacleofthepropervoltageviathepowersupply.Makesurethepowercircuitis properly grounded. Two power cords are supplied, one 115 Vac American and one 240 Vac International.

CAUTION:

This unit is designed for connection to a single phase power source . Connection to a 3 phase power source will cause significant damage to internal components .

CAUTION:

Proper electrical connection is required . It is suggested a licensed electrician be contracted to connect the AC wiring to the unit, if it is connected directly to the mains . Failure to properly connect the power wires could result in a dangerous electrical shock hazard .

MR050B SERIES DEHYDRATOR USER MANUAL

7

Note:

If the transmission lines have not been purged, continue with section 2 .7 . Otherwise proceed to section 3 .

2 .7 Purging the Transmission Line

Airinthetransmissionlinesystemmustbereplacedwithdryairtoensuresatisfactoryoperationofthetransmittedsignal.

1. Determinethetotalsystemvolume.

2. Dividethesystemvolumebytheflowrateofthedehydrator(3.0SCFH)todeterminethenumberofhoursneededforthepurgecycle.

3. Openthefarendofthetransmissionline.

4. Operatethedehydratorforthreepurgecycles.

Ifitisnotpossibletoopenthefarendofthetransmissionline,followthesesteps:

1. Connectthedehydratortothetransmissionlineandpressurizethesystem.Thesystempressureshouldreach0.5psig.

2. Wait15minuteswhiletheairabsorbsmoistureinthesystem,thendisconnectthedehydratorfromthetransmissionlineandallowtheairtovent.

3. Repeat steps 1 and 2 twelve times to purge thesystem.

2 .4 .2 Safety Ground

Ensure an electrical safety ground is installed on thegroundstudlocatedadjacenttothepowerinput connector. (It is intended to be customer installedinthefieldtoyourhalogroundingsystem.)

2 .4 .3 Test the Dehydrator

TurnthedehydratorONandchecktheoutputportontherearoftheunittomakesureairisflowing.

2 .5 Connecting the Alarm Outputs

Toconnectthealarms,locatethealarmoutputterminalblockonthefrontoftheunit.

(See section 1.4 for alarm location)

2 .6 Connecting Dehydrator to the Transmission Line

CAUTION:

Check the antenna and transmission line system pressure rating before connecting the dehydrator to the system .

Insertoneendofthe3/8”polytubefeedlinetubingintothecompressionfittingononeofthedehydratoroutputports.Tightensecurelywitha9/16”wrench.Becarefulnottoovertighten.Connecttheotherendofthepolytubetothetransmission line.

Whitestripewire:+

MR050B SERIES DEHYDRATOR USER MANUAL

8

Section 3Maintenance3 .0 Maintenance

TheMR050BDehydratorrequiresrelativelylittle maintenance to ensure satisfactory operationoverlongperiodsoftime.Thissectionoutlinestherecommendedannualpreventivemaintenancefortheunitandthesuggestedoverhaulforevery3000hoursofcompressoroperation.

3 .1 Preventive Maintenance

TheannualmaintenanceofaMR050Bconsistsofapreventativemaintenanceinspectionofthedehydrator.

Thesetaskscaneasilybeperformedinthefieldwiththeunitconnectedtothetransmissionlinesystem.

Inadditiontotheannualinspection,acompleteoverhaulisrecommendedevery3000hoursorsooner if local conditions warrant.

3 .2 Desiccant Canister Replacement

Asthedesiccantbecomessaturatedovertime,itwillchangefrombluetopinkororangetogreen.Whenthedesiccantisexhausted,therewillbeadegradation of performance. In order to replace thedesiccant,simplyturntheunitoff,disconnectthedesiccantcanisterfromthepneumaticlines,andreplacetheentirecanister.

3 .3 Annual Inspection

Inspectionincludescheckingforlooseordamagedhoses,fittings,andelectricalconnections.Removethedesiccantcanisterandverifythattherearenoleaksinthepneumaticlines.

Warning:

Electrical Hazard! Unplug power cord before servicing unit .

3 .4 Check the electrical connections .

Checkthescrewatthepowerinputconnectortoensurethattheacpowercordissecurelyterminated.Checkthescrew-inalarmterminalstoensurethatallwireconnectionsaretight.

A loose or damaged connection may result in erratic operation and unnecessary downtime. Refertothetroubleshootingsectionifanelectrical problem is encountered.

3 .5 Check the duty cycle .

Checkthehourmeteronthefrontpaneltodeterminethedutycycleofthedehydrator.

Ifthedehydratorhasbeenrunningformorethan10%ofitsinstalledtime,checkthesystemsforleaks.

3 .6 Parts Replacement

WhentheMR050Bdehydratorunitisinneedofservice,themaincomponentsaresimplyreplaced.Thecompressor,desiccantcanister,and control module are all meant to be replaceableparts.ThepartscanbepurchasedfromCommScopeforfieldreplacement,ortheunitcanbesenttotherepaircenterforcomponent replacement.

3 .7 Unit Shutdown and Removal

InordertoperformanoverhaulontheMR050B,theunitmustbeturnedoffandremovedfromservice.Asthisisbeingdone,thelowpressurealarmmayactivatethroughareportingalarmsystem.Personnelmonitoringsuchanalarmshouldbenotifiedinadvancesothattheyareawareofthefactthatserviceisbeingperformed.Itisalsonecessarytodisconnectthedehydratordryairoutputfromthewaveguidesystemduringtheoverhaul.

MR050B SERIES DEHYDRATOR USER MANUAL

9

Removethechassistopandfrontpanelsforoverhaul.

1. Unplugtheunitfromthepowersupply.

2. Followtheinstructionsincludedinthecompressorreplacementkit.Whenthereplacement is complete, reinstall.

3 .8 Service Restoration

RECOMMENDATION:

Verify unit operates normally and return to service.

MR050B SERIES DEHYDRATOR USER MANUAL

10

Section 4TroubleshootingIfyouexperiencedifficultywithyourdehydrator,usethetroubleshootingproceduresdescribedbelow.

Caution: Electrical troubleshooting requires access to potentially dangerous voltages and should only be performed by a licensed electrician

Problem/Condition Solution

Dehydratordisplaydoesnotlight,unitdoesnotrun.

Ifthedisplaylightfailstolight,makesuretheunitisplugged in and power outlet is operating. Ifyoustillhavenolight,unplugtheunit,removetheunitcoverandcheckforlooseconnections.Refertothewiringdiagram for proper connections. ChecktoassurethatthefuseisOK.Checktoassurethatproperacvoltageisbeingsuppliedtotheinput.

Low-pressurealarmactivated.

Plugtheunitoutputwithfingerandobservepressuregauge.Thepressuregaugelineshouldreadapproximately0.5psigandthealarmshouldclear.Ifalarmdoesnotclear,remove cover and verify tubing and wiring connections are secure. Ifthepressuredoesnotremainconstantafterpluggingtheoutput,applyleakdetectortoisolatetheleakinthedehydrator(exercisecarewhenapplyingsolutionnottowet wiring or electronics). IftheproblempersistscontactCommScopeCustomerService.

Compressor does not turn OFF. Checkforleaks.

MR050B SERIES DEHYDRATOR USER MANUAL

11

Figu

re 4

MR

050B

-310

15 W

iring

Dia

gram

B4

B5

A1

A2

P2

Vdc

IN

PU

T

WHITE

BLA

CK

PO

WE

R

SWITCH

48 V

acO

UTP

UT

P8

SU

M

ALA

RM

CO

MP

RE

SS

OR

+ -

BLACKWHITERED

MR050B SERIES DEHYDRATOR USER MANUAL

12

Figu

re 5

MR

050B

-312

15 W

iring

Dia

gram

B4

B5

A1

A2

P2

Vdc

IN

PU

T

WHITE

BLA

CK

PO

WE

R

SWITCH

48 V

acO

UTP

UT

P8

SU

M

ALA

RM

P9

DIS

ER

ETE

ALA

RM

CO

MP

RE

SS

OR

}+ -

WHITE

TAN

BLU

EB

RO

WN

PIN

KG

RE

EN

BLA

CK

VIOLE

TR

ED

OR

AN

GE

YELLOW

GR

AY

MR050B SERIES DEHYDRATOR USER MANUAL

13

Figu

re 6

Pne

umat

ic D

iagr

am

4PORTOUTP

UTMANIFOLD

CO

MP

RE

SS

OR

CHECK

VALVE

INP

UT

BULK

HEAD

FITT

ING

OU

TPU

TBULK

HEAD

FITT

ING

DISPOSABLE

D

ES

ICC

AN

T C

AN

ISTE

R

U2

LOW

PR

ES

SU

RE

SE

NS

OR

MR050B SERIES DEHYDRATOR USER MANUAL

14

Section 5Replacement Parts

Section 6Customer Service6 .0 Introduction

CommScope provides in-warranty and out-of-warrantyrepairsaswellasdehydratorandcompressoroverhaulsfromseveralRepairCenters.CoordinationoftheseservicesisprovidedthroughthenearestSalesOfficeorCustomerServiceCenter.TheCenterisalsopreparedtohelpyouwiththefollowing:TechnicalAssistanceTroubleshootingRepairsLoanerUnitsSparePartsInstallationMaterialsSystem Accessories.

6 .1 In Case of Trouble

Thefirststepyoushouldtakeiftroubledevelopsusingadehydratoristoreadtheoperatorsmanualandfollowthetroubleisolatingprocedures given in it.

Ifthestepsinthemanualdonotidentifyandremedytheproblem,thencontactanCommScope Customer Service Center for 24-hourtelephoneassistance.RecordtheModelNumber (e.g. MR050B) and Serial Number from theproductlabel,asyouwillbeaskedforthesewhenyoucall.Twomainlocationsarecurrentlyavailabletohelp:

COMMSCOPE3 Westbrook Corporate Center, Suite 900Westchester,IL60154USA

From North AmericaTelephone:1-800-255-1479Fax(U.S.A.):1-800-349-5444

InternationalTelephone:+1-779-435-6500FaxNumber:+1-779-435-8579

Web AccessInternet: www.commscope.comEmail: #[email protected]

Desiccant Kit MR050B-KIT-DSCNT

Compressor Kit MR050B-KIT-CPRSR

Gotocommscope.comeCatalogforthemostcurrentpartsavailableforyourdehydrator.

http://awapps.commscope.com/catalog/andrew/catalog.aspx

MR050B SERIES DEHYDRATOR USER MANUAL

15

6 .2 Initial Steps by CommScope

Whenyourcallorfaxcommunicationisreceived,theCommScopestaffwillworkwithyoutopinpointthepossiblecauseoftrouble.Ifthepressurizationequipmentissuspect,theywill:

• ask for your unit Model Number and Serial Number

• checkthewarrantystatusoftheunit

• advisetheavailabilityofaloanerunit

• provideanestimateofthecostforinspectionandrepairs,iftheunitisout–of–warranty

• faxaReturnMaterialAuthorizationSheettoyou.

6 .3 Repair Center Process

A method of Payment must be provided prior to issuing of RMA regardless of warranty status .

IN–WARRANTY REPAIR: Most CommScope pressurization products carry a warranty of one tothreeyears,dependinguponmodelnumber.Warranty details are available on our web page.Ifyourunitfallswithinitswarrantyperiod,inspection and repairs will be performed at no chargeandtheunitwillbepromptlyreturnedto you. If a warranty unit is deemed no problem foundaninspectionfeeandfreightwillbechargedtothecustomer.

OUT–OF–WARRANTY REPAIR: We will inform youwiththecostofrepairandobtainyourapprovaltoproceedwithrepairsor,ifyouelectnottohavetheunitrepaired,yourinstructionsondispositionofyourunit.Whenrepairsarecomplete, we will return your unit and invoice youfortheinspectioncharge,materialsusedfortherepairandlaborappliedtocompletetherepair.Ifyouelectednottorepairtheunit,wewillinvoiceyoufortheinspectionandfreightchargeifunitistobereturned.

LOANER UNITS:Loanerunitsareavailablefromtherepaircentertomaintainyoursystem

whilerepairsarebeingperformed.Ifyoufeelyou need a loaner, please contact us at (817) 864-4160.AP.O.forthefullvalueoftheunitmustbeissuedpriortoshipment.AlsocontactuswhentheloanerisreadytobereturnedsothatwecanissueaNEWRMAnumbertoidentifyyourreturnandcreatetheappropriatecredit to your account. Damages to loaner will bedeductedfromtheP.O.

PACKING INSTRUCTIONS: Pack your unit securelyforshipmenttotheRepairCenter.If you received a loaner unit, we suggest you usetheboxandpackingmaterialstoreturnyourunit.Otherwisewehavefactorypackingmaterials available for a nominal fee. Enclose a completedcopyofthisforminsidetheboxandclearly mark your Company Name and RMA: XXXXXXXonoutsideofthebox.AddresstheboxtothefollowingShip–ToAddress:

COMMSCOPE PRESSURIZATION SERVICE CENTERRMA# XXXXXXX11312S.PIPELINERD.EULESS,TX.76040-6629

Please note, Units received with Biological/animal contamination will be returned unrepaired or scraped after notification and you will be invoiced for inspection and freight .

CONTACT NUMBERS:Ifyouhaveanyquestionsabouttherepairprocessorstatusofyourunit,pleasecontactusdirectlythroughoneofthefollowingmethods–Telephone(below)

TEL: 817-864-4150 817-864-4155

FAX: 817-864-4179

MR050B SERIES DEHYDRATOR USER MANUAL

16