MODEL WV450X INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL WV450X FOR USE IN HAZARDOUS AND MARINE LOCATIONS WV450XD (Flameproof) ATEX 0539 II 2 G Exd IIB+ H 2 Tamb -55°C< Ta< +55°C IECEx Ex d IIB+H2 Tamb -20°C< Ta < +55°C WV450XD (Increased Safety) ATEX 0539 II 2 G Exde IIB+ H 2 Tamb -20°C< Ta< +55°C IECEx Ex de IIB+H2 Tamb -20°C< Ta < +55°C T-Code @ 110 - 248VAC = T3 T-Code @ 24 - 48VDC = T4 2562015E REV. E 612 Printed in U.S.A.

Upload: others

Post on 04-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

MODEL WV450XINSTALLATION AND SERVICE INSTRUCTIONS

FOR MODEL WV450X FOR USE IN HAZARDOUS AND MARINE LOCATIONS

WV450XD (Flameproof)ATEX 0539 II 2 G Exd IIB+ H2 Tamb -55°C< Ta< +55°C

IECEx Ex d IIB+H2 Tamb -20°C< Ta < +55°C

WV450XD (Increased Safety)ATEX 0539 II 2 G Exde IIB+ H2 Tamb -20°C< Ta< +55°C

IECEx Ex de IIB+H2 Tamb -20°C< Ta < +55°C

T-Code @ 110 - 248VAC = T3T-Code @ 24 - 48VDC = T4

2562015EREV. E 612Printed in U.S.A.

INSTALLATION AND SERVICE INSTRUCTIONS FOR FEDERAL SIGNAL MODEL WV450X FOR USE IN HAZARDOUS AND MARINE LOCATIONS.

SAFETY MESSAGE TO INSTALLERS, USERS AND MAINTENANCE PERSONNEL

It is important to follow all instructions shipped with this product. This device is to be installed by a trained electrician who is thoroughly familiar with and will follow all applicable national and local codes in the country of use.

This device should be considered a part of the warning system and not the entire warning system.

The selection of the mounting location for the device, its controls and the routing of the wiring are to be accomplished under the direction of the facilities engineer and the safety engineer. In addition, listed below are some other important safety instruc-tions and precautions you should follow:

• Readandunderstandallinstructionsbeforeinstallingoroperatingthisequipment.

• Neveraltertheunitinanymanner.Safetyinhazardouslocationsmaybe endangered if additional openings or other alterations are made in units specifically designed for use in these locations.

• Donotconnectthislighttothesystemwhenpowerison.

• Afterinstallation,ensurethatallsetscrewsandthreadedjointsareproperly tightened.

• Keepunittightlyclosedwheninoperation.

• Afterinstallation,testthelightsystemtoensurethatitisoperatingproperly.

• Aftertestingiscomplete;provideacopyofthisinstructionsheettoallpersonnel.

• Establishaproceduretoroutinelycheckthelightsystemforproperactivation and operation.

Failure to follow all safety precautions and instructions may result in property damage,seriousinjury,ordeath.

I. GENERAL.

TheModelWV450XStrobeBeaconisaZoneI,flameproofandincreasedsafetyvi-sualsignalingdevicelistedforhazardousandmarinelocations.TheModelWV450Xisavailablefor24-48Vdc,110-120Vac,50/60Hz,and220-248Vac,50/60Hz.TheWV450Xcanbesuppliedwithoutputsof5,10,or15joules.ACunitsarealsoavailableas21joule.

II. UNPACKING.

Damagedglobescanleadtoexplosionsthatcouldresultinseriousinjuryordeath.

AfterunpackingtheModelWV450X,examineitfordamagethatmayhaveoc-curred in transit. If the equipment has been damaged, do not attempt to install or oper-

-1-

ateit,fileaclaimimmediatelywiththecarrierstatingtheextentofthedamage.Care-fullycheckallenvelopes,shippinglabelsandtagsbeforeremovingordiscardingthem.Disposalofallshippingmaterialsmustbecarriedoutinaccordancewithnationalandlocal codes and standards.

III. INSTALLATION.NOTE

Theglassglobeispartoftheflameproofhousing.Therecommendedmount-ing position of this light is in a vertical orientation with the globe facing up. The unit can be mounted in other orientations pending the location of the install.

In all countries, the wiring must comply with all national and local codes and standards.

TheFederalSignalWV450Xstrobebeaconismountedusingamountingbracketfixedtothebaseoftheunit.Installthefixtureonthedesiredsupportsurfaceusingthethree 9.0 mm (0.35 in) mounting holes. Use customer-supplied fasteners suitable for thesurfacetowhichthedevicewillbemounted.RefertoFigure1formountingholelocations.

Topreventinjury,thisapparatusmustbesecurelyattachedtothefloor/wall.

A. General.

Wheninstallingandoperatingexplosion-proofelectricalequipment,therelevantnationalregulationsforinstallationandoperation(e.g.,EN60079-14andIECWiringRegulations)mustbeobserved.

• Ensurethatallnuts,boltsandfixingsaresecure.

• Paintingandsurfacefinishes,otherthanthoseappliedbyFederalSignalCorpora-tion are not permitted.

• Cableterminationshouldbeinaccordancewithspecificationsapplyingtotheap-plication.FederalSignalrecommendsthatallcablesandcoresshouldbefullyidentified.

• Ensurethatonlythecorrectcomponentcertifiedglandsareusedandthattheas-semblyisshroudedandcorrectlyearthed.GlandentriesareM20-1.56H.Supplywirestoberated85°Cminimum.

• Certifique-sedeutilizarapenasasjuntascomponentescertificadascorre-tasedequeoequipamentoinstaladoestejablindadoedevidamenteconecta-doàterra.AsentradasdasjuntassãodeM20-1,56H.Oscabosdealimentaçãosãocertificadosparatemperaturamínimade85°.

• Ensurethereisnottoomuchslackofcablecoreswithintheunit,duetospacelimitations.

• Ensurethatonlythesuppliedstoppingplugsareusedtoblankoffunusedglandentrypoints.FailuretodosomaynegatetheIPratingontheunit.

-2-

• Thisdevicedoesnotcontainover-currentprotection.Theinstallershouldselectanappropriateover-currentdeviceforthemodel(s)beingused.ReferenceTable1fortheappropriate values.

This manual contains standard wiring configurations.

B. Wiring installation for the WV450XD Flameproof version.

Donotconnectifsupplywiresareenergized.

TheDCunitsarepolaritysensitive,andMAYBEDAMAGEDbyincorrectelectricalhookup.WhenconnectingtheDCstrobeunittothevoltagesupplylines,POLARITYMUSTBEOBSERVED.Inaddition,damagewillresultifthevoltageratingoftheparticularmodelisexceeded.

1. ModelWV450XD24-48Vdc.

NOTEMaximumwiregageis2.5mm2(12AWG)Usewirerated85°Corhigher.EnsureonlystrandedormultiplestrandcableisusedtoterminatetheWV450X.

Cableterminationshouldbeinaccordancewithspecificationsapplyingto the application It is recommended that all cables and cores should be fully identified. UsetheappropriatecableglandfortheapplicationGlandentrythreadsareM20-1.5x6H.

a. Unscrew the grub screw on the lens cover assembly one full turn (2.0mmA/Fhexagonkeyrequired).Removethecoverfromthehousingbyturningthecovercounter-clockwise.Ifthelenscoverassemblywillnotunscrew,backoutthegrubscrewafewadditionalturns.Oncethecoverhasbeenremoved,slidethePCBoutuntilthe terminals clear the case. Wire insulation to be stripped 5 mm to 6 mm (0.22 in). Theterminalblockusesaspringclampconnectiontoengagethewire.Todisengagethe clamp, insert a 2 mm blade tip screwdriver into the small openings near the top. Insert the stripped wire into the larger opening and remove the screwdriver to engage thewireclamp.Connectthepositive(+)powersourcewiretotheterminalblockscrewmarked“+”.Connectthenegative(–)powersourcewiretotheterminalblockscrewmarked“–”.UseFigure2forreference.

b. Aftercableterminationhasbeencompleted,thePCBcanbefullyinsertedintotheenclosure.EnsurethatthebottomedgeofPCBistrappedbetweentheholdingpegsinthebottomoftheenclosure.BeawareofthecorrectPCBorientation,asthere is only one way the board will fit. The large capacitors should face the largest side ofthePCBoffsetinsidetheenclosure.

c. To replace the cover, use the same procedure as removing but in reversemanner,ensuringthecoverisscrewedtightly.Turnthecoverclockwisetotighten.Thereshouldbeamaximumgapof0.3mm(0.012in)betweenthefacesofthe

-3-

enclosureandcovertoensureO-ringcompression.Turnthegrubscrewonefullturnoruntil the screw contacts the housing.

d. Ensurethattheunusedwireentryissealedwiththeprovidedcom-ponentcertifiedbrassM20-1.5x6gstoppingplug.

2. ModelsWV450XD110and220Vac.

NOTEMaximumwiregageis2.5mm2(12AWG)Usewirerated85°Corhigher.EnsureonlystrandedormultiplestrandcableisusedtoterminatetheWV450X.

Cableterminationshouldbeinaccordancewithspecificationsapplyingto the application It is recommended that all cables and cores should be fully identified. Use the appropriate cable gland for the application Gland entry threads are M20-1.5 6H.

a. Unscrew the grub screw on the lens cover assembly one full turn (2.0mmA/Fhexagonkeyrequired).Removethecoverfromthehousingbyturningthecovercounter-clockwise.Ifthelenscoverassemblywillnotunscrew,backoutthegrubscrewafewadditionalturns.Oncethecoverhasbeenremoved,slidethePCBoutuntilthe terminals clear the case. Wire insulation to be stripped 5 mm to 6 mm (0.22 in). Theterminalblockusesaspringclampconnectiontoengagethewire.Todisengagethe clamp, insert a 2 mm blade tip screwdriver into the small openings near the top. Insert the stripped wire into the larger opening and remove the screwdriver to engage thewireclamp.Connecttheline(hot)powersourcewiretotheterminalblockclampmarked“L”.Connecttheneutral(common)powersourcewiretotheterminalblockclampmarked“N”.Connectthegroundwiretotheterminalblockclampmarkedwiththe ground symbol. Use Figure 2 for reference.

b. Aftercableterminationhasbeencompleted,thePCBcanbefullyinsertedintotheenclosure.EnsurethatthebottomedgeofPCBistrappedbetweentheholdingpegsinthebottomoftheenclosure.BeawareofthecorrectPCBorientation,as there is only one way the board will fit. The large capacitors should face the largest sideofthePCBoffsetinsidetheenclosure.

c. To replace the cover, use the same procedure as removing but in reversemanner,ensuringthecoverisscrewedtightly.Turnthecoverclockwisetotighten.Thereshouldbeamaximumgapof0.3mmbetweenthefacesoftheenclosureandcovertoensureO-ringcompression.Turnthegrubscrewonefullturnoruntilthescrew contacts the housing.

d. EnsurethattheunusedwireentriesaresealedwiththeprovidedcomponentcertifiedbrassM20-1.5x6gplug.

C. Wiring installation for the WV450XE Increased Safety version.

Donotconnectifsupplywiresareenergized.

-4-

TheDCunitsarepolaritysensitive,andMAYBEDAMAGEDbyincorrectelectricalhookup.WhenconnectingtheDCstrobeunittothevoltagesupplylines,POLARITYMUSTBEOBSERVED.Inaddition,damagewillresultifthevoltageratingoftheparticularmodelisexceeded.

TheWV450XEterminalblockissuppliedwith3polesand4conductorsperpole.Theterminalblocksallowsforeasysupplyinandloopoutwiringtostringbeaconsinseries.Theterminalblockusesaspringclampconnectiontoengagethewire. To disengage the clamp, insert a 2 mm blade tip screwdriver into the small open-ings closest to the terminal labels as shown in Figure 4. Insert the stripped wire into the larger opening and remove the screwdriver to engage the wire clamp.

1. ModelWV450XE24-48Vdc.

NOTEMaximumwiregageis2.5mm2(12AWG)Usewirerated85°Corhigher.EnsureonlystrandedormultiplestrandcableisusedtoterminatetheWV450X.

Cableterminationshouldbeinaccordancewithspecificationsapplyingto the application It is recommended that all cables and cores should be fully identified. Use the appropriate cable gland for the application Gland entry threads are M20-1.5 6H.

a. UnscrewthefourM4screwsandliftofftheterminalboxcover.Theterminalblockissuppliedwith3poles,4conductorsperpole.Theterminalblocksallowfor easy supply in and loop out wiring to string beacons in series. Wire insulation to be stripped8mmto9mm(0.33in).Theterminalblockusesaspringclampconnectiontoengage the wire. To disengage the clamp, insert a 2 mm blade tip screwdriver into the small openings closest to the terminal labels as shown in Figure 4. Insert the stripped wire into the larger opening and remove the screwdriver to engage the wire clamp. Connectthepositive(+)powersourcewiretotheterminalblockpolemarked“L1/+”.Connectthenegative(–)powersourcewiretotheterminalblockpolemarked“N/–”.Use Figure 3 for reference. When using more than one single or multiple strand lead, theconnectionintoeithersideofanyterminalmustbejoinedinasuitablemanner,e.g.,two conductors into a single insulated crimped bootlace ferrule.

NOTE

Leadsconnectedtotheterminalsshallbeinsulatedfortheappropriatevoltageandthisinsulationshallextendtowithin1mmofthemetaloftheterminal throat.

NOTEConductivemetalwork(inc.cableglands)mustbeaminimumof5mmawayfrom the terminals.

-5-

b. Aftercableterminationhasbeencompleted,thecovercanbereinstalledtotheterminalboxusingthefourM4screws.EnsurethegasketisproperlyseatedtomaintaintheIPrating.Donotover-tightenthecoverscrews.

c. EnsurethatallunusedwireentriesaresealedwiththeprovidedcomponentcertifiedblacknylonM20-1.5X6Hstoppingplugs.

2. ModelsWV450XE110and220Vac.

NOTEMaximumwiregageis2.5mm2(12AWG)Usewirerated85°Corhigher.EnsureonlystrandedormultiplestrandcableisusedtoterminatetheWV450X.

a. UnscrewthefourM4screwsandliftofftheterminalboxcover.Theterminalblockissuppliedwith3poles,4conductorsperpole.Theterminalblocksallowfor easy supply in and loop out wiring to string beacons in series. Wire insulation to be stripped8mmto9mm(0.33in).Theterminalblockusesaspringclampconnectiontoengage the wire. To disengage the clamp, insert a 2 mm blade tip screwdriver into the small openings closest to the terminal labels as shown in Figure 4. Insert the stripped wire into the larger opening and remove the screwdriver to engage the wire clamp. Connecttheline(hot)powersourcewiretotheterminalblockpolemarked“L/+”.Con-necttheneutral(common)powersourcewiretotheterminalblockpolemarked“N/–”.Connectthegroundwiretotheterminalblockpolemarkedwiththegroundsymbol.Use Figure 3 for reference. When using more than one single or multiple strand lead, theconnectionintoeithersideofanyterminalmustbejoinedinasuitablemanner,e.g.,two conductors into a single insulated crimped bootlace ferrule.

NOTELeadsconnectedtotheterminalsshallbeinsulatedfortheappropriatevoltageandthisinsulationshallextendtowithin1mmofthemetaloftheterminal throat.

NOTE

Conductivemetalwork(inc.cableglands)mustbeaminimumof5mmawayfrom the terminals.

b. Aftercableterminationhasbeencompleted,thecovercanbereinstalledtotheterminalboxusingthefourM4screws.EnsurethegasketisproperlyseatedtomaintaintheIPrating.Donotover-tightenthecoverscrews.

-6-

c. EnsurethatallunusedwireentriesaresealedwiththeprovidedcomponentcertifiedblacknylonM20-1.56Hstoppingplugs.

IV. MAINTENANCE.

Topreventignitionofhazardousatmospheres,disconnectthefixturefromthesupplycircuitbeforeopening.Donotopenwhenanexplosivegasatmosphereis present.

AVISO DE PERIGOParapreveniraigniçãodegasesperigosos,desconecteodispositivodocircuitodealimentaçãoantesdeabri-lo.Nãoabranapresençadegasesexplosivosnaatmosfera.

High voltages are present inside the light assembly. Wait at least 5 minutes after disconnecting the power before servicing this unit.

A. General.

POTENTIAL ELECTRIC STATIC CHARGING HAZARDIftheunitrequirescleaning,thenONLYcleanexteriorwithawaterdamp-ened cloth to avoid electrostatic charge build-up.

AVISO DE PERIGOPERIGO DE POTENCIAL CARGA ELETROESTÁTICA Emcasodeterquelimparaunidade,limpeAPENASaparteexternacomum pano úmido, a fim de evitar o acúmulo de carga eletroestática.

Duringtheworkinglifeoftheunit,itshouldrequirelittleornomaintenance.GRPwillresistattackbymostacids,alkalisandchemicalsandisasresistanttocon-centratedacidsandalkalisasmostmetalproducts.However,ifabnormalorunusualenvironment conditions occur due to plant damage or accident etc. then visual inspec-tion is recommended.

SAFETY MESSAGE TO MAINTENANCE PERSONNEL

Listedbelowaresomeimportantsafetyinstructionsandprecautionsyoushouldfollow:

• Readandunderstandallinstructionsbeforeoperatingthissystem.

• Anycompetentsitepersonnelcancarryoutthereplacementofthexenontube.OtherrepairsshouldbeundertakenbyreturningtheunittoFed-eralSignalCorporationorbyanauthorizedrepairerofExequipment.

• Ifyouacquiredasignificantquantityofunits,thenitisrecommendedthat spares are also made available.

-7-

• Anymaintenancetothelightsystemmustbedonewithpowerturnedoff.

• Anymaintenancetothelightsystemmustbeperformedbyatrainedelectrician who is thoroughly familiar with all applicable national and local codes in the country of use.

• Neveraltertheunitinanymanner.Safetyoftheunitmaybeaffectedifadditional openings or other alterations are made to the internal compo-nents or housing.

• Thenameplate,whichmaycontaincautionaryorotherinformationofimportancetomaintenancepersonnel,shouldNOTbeobscuredinanyway.Ensurethatthenameplateremainsreadable.

• Afterperforminganymaintenance,testthelightsystemtoensurethatit is operating properly.

B. Flash Tube Replacement.

Asstrobelightsareused,theflashtubesbegintodarken,causingthelightoutputtodecrease.Thisdarkeningischaracteristicofflashtubes.Darkeningwillbeginnearthebaseofthetubeandprogressupward.Also,asflashtubesage,theymayhavea tendency to misfire (not fire periodically).

Afterextendedoperation,occasionallycheckforflashtubedegradation.Shouldtheflashtubemisfire,haveanoticeabledecreaseinlightoutput,glowcontinu-ouslyordarken-itshouldbereplaced.

High voltages are present inside the light assembly. Wait at least 5 minutes after disconnecting the power before servicing this unit.

To change the strobe tube, proceed as follows:

1. Disconnectpower.

2. Loosenthegrubscrewlocatedonthelenscoverassembly.

3. Removethelenscoverassemblyfromthehousingbyrotatingthecovercounterclockwise.Ifthelenscoverassemblywillnotunscrew,backoutthegrubscrewafew additional turns.

4. Grasptheflashtubebyitsbaseandpullitoutofthesocket,usingagentle“rocking”motion.Insertthenewflashtube.Ensurethestrobelampisfirmlyseatedinthesocket.

Tomaintaintheexplosion-proofintegrityoftheenclosure,DONOTdamagetheglobeorthreadswhiledisassemblingorreassemblingunit.Lubricatedjointsexposedforlongperiodsoftimemayattractsmallparticlesofdirtorotherforeignmaterials.Bodyandcoverjointsshouldbereassembledim-mediately.

-8-

5. Reinstallthelenscoverassemblytothehousingbyrotatingthecoverclockwise.Thereshouldbeamaximumgapof0.3mmbetweenthefacesofthehousingand cover to ensure o-ring compression for an environmental seal.

6. Tighten the lens cover assembly grub screw until snug.

7. Testthelightforproperoperation.

C. Cleaning the Enclosure.

ThecircuitmustbeturnedOFFandallowedtocooltothesurroundingambi-ent temperature before cleaning.

Fixtureshouldbecleanedperiodicallytomaintainmaximumlightoutput.Onlycleantheexteriorwithawaterdampenedclothtoavoidelectro-staticchargebuild-up. The glass globe should be regularly inspected for scratches and chips, and, if damaged, must be replaced.

D. Service.

FederalSignalwillserviceyourequipmentandprovidetechnicalassistancewithanyproblemsthatcannotbehandledlocallybyFederalSignal’sDistributororManufacturerRepresentative.

AnyunitsreturnedtoFederalSignalforservice,inspection,orrepairmustbeaccompaniedbyaReturnMaterialAuthorizationnumberwithabriefexplanationoftheservicebeingrequestedand/orthenatureofthemalfunction.ThisR.M.A.canbeobtainedfromalocalFederalSignalDistributororManufacturer’sRepresentative.

Inordertoexpediteservice,pleaserefertotheproductmodelnumberandserial number on the label the serial number is interpreted as follows:

G0616400000 G=FactoryProductCode 06=Lasttwodigitsforyearofmanufacture 164=Numericaldaycodeforyearofmanufacture 00000 = five digit code for product serial number.

-9-

-10-

Addressallcommunicationsandshipmentsto: FEDERALSIGNALCORPORATION IndustrialSystemsDivision ServiceDepartment 2645FederalSignalDrive UniversityPark,IL60484-3167 USA

E. Replacement Parts.

Description PartNumber

CoverLensAssy.,Amber K8595116-AACoverLensAssy.,Blue K8595116-BACoverLensAssy.,Clear K8595116-CACoverLensAssy.,Green K8595116-GACoverLensAssy.,Red K8595116-RACoverLensAssy.,Yellow K8595116-YACoverLensAssy.,Magenta K8595116-MAFlashTube/TriggerCoilAssy. K8107177CircuitBoard,24-48Vdc,5joules K2001926-01CircuitBoard,24-48Vdc,10joules K2001926-02CircuitBoard,24-48Vdc,15joules K2001926-03CircuitBoard,110Vac,5joules K2001921-01CircuitBoard,110Vac,10joules K2001921-02CircuitBoard,110Vac,15joules K2001921-03CircuitBoard,110Vac,21joules K2001921-07CircuitBoard,220Vac,5joules K2001921-04CircuitBoard,220Vac,10joules K2001921-05CircuitBoard,220Vac,15joules K2001921-06CircuitBoard,220Vac,21joules K2001921-08DomeGuard K8595107

V. EC DECLARATION OF CONFORMITY.

Manufacturer’sName:FederalSignalCorporation Manufacturer’sAddress:2645FederalSignalDrive UniversityPark,IL60484-3167 U.S.A. DeclaresthattheProductTypeofEquipmentModelNumber(s):WV450X conformstothefollowingStandards:

CERTIFICATION.

UNDERWRITERSLABORATORIES,INC./DEMKO I. IECEx=IECEx06.0010X • IEC60079-0,60079-1,60079-7,60529 II. ATEX=ULDEMKO06ATEX0425693X • EN60079-0,60079-1,60079-7,60529

-11-

Table 1

Voltage Model I avgRecommendedover-current protection

24 Vdc

15joules 900mA 5 amps

10joules 640mA 5 amps

5joules 400mA 5 amps

48 Vdc

15joules 450mA 3 amps

10joules 320mA 3 amps

5joules 200mA 3 amps

110 Vac 50Hz

21joules 295mA 2 amps

15joules 370mA 3 amps

10joules 195mA 3 amps

5joules 135mA 3 amps

248 Vac 50Hz

21joules 300mA 3 amps

15joules 295mA 2 amps

10joules 180mA 2 amps

5joules 85mA 2 amps

240 Vac 50Hz

21joules 290mA 2 amps

15joules 290mA 2 amps

10joules 185mA 2 amps

5joules 88mA 2 amps

220 Vac 50Hz

21joules 265mA 2 amps

15joules 264mA 2 amps

10joules 200mA 2 amps

5joules 88mA 2 amps

SpecialConditionsforSafeUse:

1) Potentialelectricstaticcharginghazard.Useonlyawaterdampenedclothwhencleaningtheexterioroftheunit.

2) Contactthemanufacturerforinformationonthedimensionoftheflame-proofjoints.

CondiçõesespeciaisparaoUsoSeguro:

1) Perigodepotencialcargaeletroestática.Aolimparaparteexternadaunidade,utilizeapenasumpanoúmido. 2) Contateofabricanteparaobterinformaçãosobreadimen-sãodasjuntasàprovadefogo.

-12-

Figure 1.

M20 GLAND ENTRY2 POSITIONS

290A5411B

63.5 [2.50]

ø39.4 [ø1.55]X 2

41.3 [1.63]

136.5 [5.37]114.3 [4.50]

57.2 [2.25]

12.7 [0.50]41.3 [1.63]

82.6 [3.25]

289.7 [11.41] 113.3 [4.46]

EExd VERSION

EExde VERSIONø8.9 [ø0.35]X 3MOUNTING HOLES

97.1 [3.82]

57.4 [2.26]

M20 GLAND ENTRIES3 POSITIONS

CERTIFICATIONLABEL

WARNING LABEL

GUARDLENS COVER ASSY GRUB SCREW

EExde COVER SCREWS

-13-

Figure 3.

Figure 2.

DC VOLTAGE UNITS AC VOLTAGE UNITS

290A5412

J2+- - +

LOOP �OUT

SUPPLY�IN

LOOP �OUT

SUPPLY�IN

INPUT�24-48VDC

J2

INPUT�110VAC�240VAC

L L NN GND GND

WV450XE AC OR DC UNITS

TO LINE BUSHING

SUPPLY IN= L1, N1, G1�

LOOP OUT= L2, N2, G2

EExde AC OR DC UNITS�TERMINAL BLOCK

L L N N

L L N N G G2 2 2

290A5413

-14-

L1 +-N

290A5532

Figure 4.

Industrial Systems2645 Federal Signal Drive • University Park, IL 60484-3167Tel: 708-534-4756 • Fax: 708-534-4852Email: [email protected] • www.federalsignal-indust.com