led luminaire for street lighting italo 2 · 2019. 11. 23. · italo 2 - optics italo 2 available...

10
ITALO 2 LED luminaire for street lighting Registered models – Design by Massimo Sacconi and Marzia Bandini MADE IN I TALY

Upload: others

Post on 24-Aug-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

ITALO 2LED luminaire for street l ighting

Registered models – Design by Massimo Sacconi and Marzia Bandini

MADE IN I TALY

Page 2: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

Ava i lab le ve r s ion sI TALO 2

Compact design in line with the “contemporary trend”:ITALO is the exclusive series of AEC luminaires able to meet the needs of the most modern Smart Cities. Functionality, versatility, and a wide variety of optics feature ITALO 2, designed for the lighting of high traffic urban and suburban streets. Quality light, excellent colour rendering, optimum energy efficiency.ITALO: a preview on the future of lighting.

PERFORMANCE OPTIC

Page 3: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

ITALO 2 | TECHNICAL DATA SHEET | 3

NERO e GRIGIO per marchi piccoli (ha il �lo ingrossato)

Ava i lab le ve r s ion s

NERO e GRIGIO per marchi piccoli (ha il �lo ingrossato)

432

805

122

260

919

805

Ø 33/60Ø 60/76 OPTIONAL

432

805

122

260

919

805

Ø 33/60Ø 60/76 OPTIONAL

432

80512

2

260

919

805

Ø 33/60Ø 60/76 OPTIONAL

AVAILABLE COMPOSITIONS:STE-M / STE-S / STW / STU-M / STU-S / SV optics: from 4 to 8 modules.

OPTICAL UNIT CHARACTERISTICS:Modular optical system.LED source colour temperature: 4000K (3000K, 5700K optional).CRI > 70.

OPTIONS

Please, download ITALO 2photometric data at www.aecilluminazione.com

Ø 60/76Ø 60/76

POST TOP ATTACHMENT Ø60÷76mm HEAT SINK PROTECTION SCREEN

Page 4: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

MECHANICAL CHARACTERISTICS

• Frame and cover in die cast aluminum alloy UNI EN 1706.

• Heat sink in die cast aluminum UNI EN 1706 with lamellar design.

• Polyurethane seal.

• tempered glass (5mm thickness) featured by high transparency and optimum thermal and mechanical resistance (IK09).

• Removable optical unit in 99.85% aluminum with special

• Removable LED module.

• Removable metal gear plate.

• Watertight membrane grommet.

• Integrated cable clamp.

• Post top or brackets mounting in die cast aluminum alloy UNI EN 1706 for Ø33÷Ø60mm and Ø60÷Ø76mm (optional). Post top tilt: 0°, +5°, +10°, +15°, +20°. Bracket tilt: 0°, -5°, -10°, -15°, -20°.

• Closure hook in extruded aluminum with stainless steel spring.

IP66 protection degree.

ELECTRICAL CHARACTERISTICS

• Insulation class: I, II - US: 1.

• Power supply: 220÷240V - 50/60Hz.

• LED current: 525/700mA.

• Power Factor: >0.9 (at full load).

• Connection for cables featured by a maximum cross section of 4mmq.

• Optional fuse.

• Optical unit lifetime 525mA (Ta=25°C): >70.000hr B20L80 (included critical failures); >100.000hr L80, TM-21; 700mA (Ta=25°C): >50.000hr B20L80 (included critical failures); >70.000hr L80, TM-21.

• Available dimming options: DA: automatic dimming; DAC: customizable DA PLM: power line adjustment.

I TA LO 2

• Optical unit lifetime525mA (Ta=50°C):

>50.000hr B20L80 (included critical failures);>60.000hr L80, TM-21;

700mA (Ta=40°C):>50.000hr B20L80 (included critical failures);>60.000hr L80, TM-21.

finish made by vacuum sealed deposition 99.95%. Aluminium class A+ (DIN EN 16268).

• Colour: semi-gloss satiny grey. Code 2B.

(Standard tolerance +/- 10%. Other voltages and tolerances upon request).

Page 5: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

NERO e GRIGIO per marchi piccoli (ha il �lo ingrossato)

ITALO 2 | TECHNICAL DATA SHEET | 5

PROTECTION AGAINST OVERVOLTAGE

A lighting device installed in

a standard electrical system

may be subjected to voltage

fluctuations and external

disturbances due to different

factors such as discontinuous

loads on the line, faults on the

lines (upstream or downstream)

and atmospheric electrical

discharges (in outdoor

installations).

In those LED installations where

the electronic components are

predominant, an adequate

resistance to surges is

synonymous with reliability and

proper functionality.

Thanks to the research and

the experimentation performed

in its own laboratories, AEC

offers its customers customized

solutions according to every

specific installation.

CLASS I: protection up to 10kV.

CLASS II: protection from 6kV

up to 10kV.

For more information about the

protection against overvoltage,

please download the technical

report at

www.aecilluminazione.com.

Page 6: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

I TA LO 2 - op t i c s

ITALO 2

AVAILABLE OPTICSNAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS

STE-M

SUBURBAN STREET OPTICAsymmetrical optic for street and motorway lighting. Specifi c optic for roadways where the width is

equivalent to the pole height.

STE-M

Coordinate system C-Gamma, polar graph.

Gamma Angles

cd/klm

180 120

105

90

75

60

45

105

90

75

60

45

30 3015 150

100

100

200

300

400

500ITALO STE-M (Polare)

STE-S

SUBURBAN STREET OPTICAsymmetrical optic for street and motorway lighting. Specifi c optic

for roadways where the width corresponds to 0,75 times the pole

height.

STE-S

Coordinate system C-Gamma, polar graph.

Gamma Angles 180 120

105

90

75

60

45

105

90

75

60

45

30 3015 150

150

150

300

450

600

750ITALO STE-S (Polare)cd/klm

STU-M

URBAN STREET OPTICAsymmetrical optic for street and cycle path lighting. Specifi c optic for roadways where the width is

equivalent to the pole height.

STU-M

Coordinate system C-Gamma, polar graph.

Gamma Angles 180 120

105

90

75

60

45

105

90

75

60

45

30 3015 150

150

150

300

450

600

750ITALO STU-M (Polare)cd/klm

STU-S

URBAN STREET OPTICAsymmetrical optic for street and cycle path lighting. Specifi c optic

for roadways where the width corresponds to 0,75 times the pole

height.

STU-S

Coordinate system C-Gamma, polar graph.

Gamma Angles 180 120

105

90

75

60

45

105

90

75

60

45

30 3015 150

150

150

300

450

600

750ITALO STU-S (Polare)cd/klm

STW

WIDE EMISSION STREET OPTICAsymmetrical optic for wide streets

and wet asphalt.Specifi c optic for roadways where

the width corresponds to 1,25times the pole height.

STW

Coordinate system C-Gamma, polar graph.

Gamma Angles 180 120

105

90

75

60

45

105

90

75

60

45

30 3015 150

90

90

180

270

360

450ITALO STW (Polare)cd/klm

SV

STREET JUNCTIONS OPTICAsymmetrical optic for motorway

junctions and narrow street lighting.Specifi c optic for roadways where the width corresponds to 0,5 times

the pole height.

SV

Coordinate system C-Gamma, polar graph.

Gamma Angles 180 120

105

90

75

60

45

105

90

75

60

45

30 3015 150

150

150

300

450

600

750ITALO SV (Polare)cd/klm

Page 7: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

ITALO 2 | TECHNICAL DATA SHEET | 7

NERO e GRIGIO per marchi piccoli (ha il �lo ingrossato)

SELECTION OF THE OPTICS ACCORDING TO UNI EN 13201 LIGHTING CATEGORIES

Installation rep.L/H

ITALO 2 ITALO 2 ITALO 2

H

L1.5 STW

H

L1.25 STW

STU-M STW

H

L1 STE-M STU-M

H

L0.75 STE-S STU-S

STU-S STE-M

H

L0.5 SV

H

L0.25 SV

UNI EN 13201Lighting categories

CEO ME1

CE1

ME2

CE2

ME3

CE3

ME4

CE4

ME5

CE5

ME6

CE6 S1 S2 S3 S4 S5 S6

MEW 1

MEW 2

MEW 3

MEW 4

MEW 5

Street Application Cycle path ApplicationStreet Application

WET Class

Page 8: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

Dimming op t ion s

LED technology offers easy and reliable light fl ux adjustment. The devices are equipped with an electronic power supply capable

of adjusting light emission by directly regulating the optical assembly LED input current. The standard version of the device is

supplied with a constant LED input current of 525mA or 700mA.

The following options are available:

LCU

The Light Control Unit offers fl exible system control. The reduction profi le can be customised

with simple local or remote programming. Devices can be divided into sub-groups with different

dimming profi les. Option of using an astronomical clock or interfacing with external switching

devices. Simplifi ed installation, wiring and testing. Programming software free of charge.

PLM OPTION

Light fl ux regulation using power line communication

Light fl ux reduction can be associated with punctual and

remote monitoring of the individual device via the power line

communication remote control. This option, used in conjunction

with an LCU (Light Control Unit), makes it possible to control an

individual lighting point, allowing the creation of customised

lighting scenarios. More complex remote control panels can be

used as part of a wireless or GSM/GPRS network, to remotely

monitor the energy consumption of the system and provide fault

indications as necessary without the need for on-site maintenance

procedures.

*Saving in relation to the fi xed power version.

LCU

DA (DIM-AUTO) OPTIONAutomatic light fl ux regulation

The power supply is confi gured using an automatic dimming

profi le which fully utilises the maximum light intensity during the

fi rst and last few hours of system operation, thereby reducing

energy consumption in the middle of the night when a lower

level of illumination is often suffi cient. The reduction profi le

automatically adapts to the duration of the night-time period

during the year.

DAC OPTION (DIM-AUTO CUSTOM PROFILE)

The power supply is confi gured using a dimming profi le totally

customizable by the user (up to 5 levels in 4 steps).

L1:100%

L2: 70%

Tdim: 6hr

Saving*: 15%

100%100% 100%

70%

0.00 6.0060%

20%

80%

40%

0%17 19 2218 20 2321 0 1 3 52 4 6 7

Page 9: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

NERO e GRIGIO per marchi piccoli (ha il �lo ingrossato)

ITALO 2 | TECHNICAL DATA SHEET | 9

OPTIONS ON REQUEST (SUBJECT TO FEASIBILITY CHECK)

D10 (DIM-10) OPTIONFlux adjustment via 1-10V analogue controlAllows lighting device adjustment via an analogue voltage signal between 1V and 10V, the minimum and maximum brightness levels respectively. The device is designed for connection of L-N-1/10V cables.

LN1-10V

LNPILOT CABLE

LNDALI

DALI (DIGITAL ADDRESSABLE LIGHTING INTERFACE) OPTIONFlux adjustment via digital interfaceDALI is the standard digital technology for the management of luminaires; it is based on a digital signal capable of univocally addressing up to 64 modules on the same bus. The device is designed for connection of L-N-DALI cables.

LN1-10V

LNPILOT CABLE

LNDALI

DB (DIM-BIP) OPTIONBi-power light fl ux adjustment with pilot cableOption mainly designed for underpasses or small systems where a simple and synchronised fl ux reduction is required. The device is supplied with a bi-power switch which will stablish an operating regime at full or reduced power, depending on whether in additional conductor (pilot cable) is also present or not.

LN1-10V

LNPILOT CABLE

LNDALI

DR (DIM-REG) OPTIONLight fl ux adjustment with fl ux controllersLED retrofi t systems may include a discharge lamp fl ux controller. This option allows the LED device to follow up the voltage adjustment carried out within the system, varying the LED input current as a result. This means both HID and LED devices can be installed within the same system, thereby fully utilising existing energy saving systems. Operation is only guaranteed if amplitude modulation controllers are used instead of phase cut controllers.

FLUX CONTROLLER

ADDITIONAL OPTIONS:(Can be combined with all other fl ux reduction options, subject to feasibility check)

FLC OPTION - LED light fl ux recoveryThe natural depreciation of the light fl ux produced by the LEDs can be offset by progressively increasing the input current of the LEDs during operation. This option guarantees a virtually constant light fl ux output.The ligh-ting system can therefore be designed while taking account of a maintenance factor which is higher than that usually used with the standard product, offering instant savings in terms of the energy consumed and/or the initial cost of the system. The FLC option also means the useful life of the system can be extended.

LUMINOUS FLUX at constant current

LUMINOUS FLUX with FLC

Luminaire wattage at �xed current

Luminaire wattage with FLC

100%

85%

120%100%

80%

80%80%

FR (FULL RANGE) OPTION - Extended input voltage rangeOption of supplying the device with an extended input voltage (example: 120-277V). This option maintains device operation even in systems where the power supply voltage is adjusted by fl ux controllers.

120 - 277 VAC50 / 60 Hz

FC (PHOTOCELL) OPTIONPossibility to install a twilight switch that allows to automatically turn the unit on at sunset and to turn it off at sunrise.

SYSTEM FEATURES AND ADJUSTMENT SYSTEM INSTALLATION:

DA/DAC PLM & LCU PLM DB DR DALI D10Independent adjustment system xCentral adjustment system (switch / control unit / cabinet) x x x x x xRemote reduction profi le change x x x x x xUse of additional cables x x xRemote management software required xFree confi guration software (LED and electronic HID systems only) x

Interfacing with external regulation systems (e.g. PIR sensors, traffi c sensors, switches) x x x x

Commissioning by specialist personnel x x x x

Page 10: LED luminaire for street lighting ITALO 2 · 2019. 11. 23. · ITALO 2 - optics ITALO 2 AVAILABLE OPTICS NAME DESCRIPTION DRAWING PHOTOMETRY OPERATING ENVIRONMENTS STE-M SUBURBAN

NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

The information contained in this catalogue aren’t binding.

In order to guarantee a continuos updating of its products,

AEC reserves itself the right to modify the contents without notice.

AEC Illuminazione SrlI-52010 Subbiano - Arezzo - Italy

Via Righi, 4 - Zona Industriale CastelnuovoTel. +39 0575 041110Fax +39 0575 420878

[email protected]