DeMeo Residence % Percent & And @ At A/C Air Conditioning AB Anchor Bolt ACP Acoustic Ceiling Panel ACPNL Access Panel ACT Acoustic Ceiling Tile AD Area Drain ADD Addendum ADJ Adjustable ADMIN Administration, Administrator AE Architect-Engineer AFF Above Finished Floor AGG Aggregate AHU Air Handling Unit ALT Alternate ALUM Aluminum ANCH Anchor(age) ANOD Anodized APPD Approved APPROX Approximate ARCH Architect(ural) ASPH Asphalt ASSN Association AT Asphalt Tile AUTO Automatic AV Audiovisual AVG Average AWP Acoustic Wall Panel B Bathroom BATT Battery BCAB Base Cabinet BD Board BIT Bituminous BL Building Line BLDG Building BLKG Blocking BM Beam BMK Benchmark BOT Bottom BDRM Bedroom BRG Bearing BRGPL Bearing Plate BRK Brick BRKT Bracket BSMT Basement BTWN Between BVLD Beveled BW Both Ways C Courses C to C Center to Center CAB Cabinet CALK Caulking CB Catch Basin CBD Chalk Board CEM Cement CER Ceramic CF/CI Contractor Furnish/Contractor Install CFM Cubic Feet Per Minute CG Corner Guard CH Coat Hook CHAM Chamber CHAN Channel CI Cast Iron CIP Cast In Place CIR Circle, Circular, Circumference CJ Control Joint CL Center Line CLG Ceiling Line CLL Contract Limit Line CLO Closet CLR Clear, Clearance CMU Concrete Masonry Unit CNTR Counter CO Clean Out CO2 Carbon Dioxide COL Column COMP Company COMPO Composite, Composition COMPR Compress(ed), (OR), (ION), (IBLE) COMPT Compartment CONC Concrete COND Condition COND VT Conductive Vinyl Tile CONN Connection CONST Construction CONT Continue, Continuous CONTR Contractor CONV Convenience COR Corner CORR Corridor CPR Copper CPT Carpet CR Cold Rolled CRS Cold Rolled Sheet CSG Casing CSK Counter Sunk CSMT Casement CST Cast Stone CT Ceramic Tile CTR Center CU Cubic Feet CUB Cubicle CUFT Cubic Foot CUIN Cubic Inch CUYD Cubic Yard CW Cold Water CWK Casework DBANCH Deformed Bar Anchor DBL Double DEG Degree DEMO Demolish, Demolition DEPT Department DET Detail DF Drinking Fountain DH Double Hung DIA Diameter DIAG Diagonal DIFF Diffuser DIM Dimension DISP Dispenser DIST Distribute DIV Division DL Dead Load DMPR Damper DN Down DO Ditto DP Damp Proofing DPL Disposal DR Door DRN Drain DS Down Spout DW Dishwasher DWG Drawing DWR Drawer E East E to E End to End EA Each EDF Electronic Drinking Fountain EF Exhaust Fan EIFS Exterior Insulated Finish System EJ Expansion Joint EL Elevator ELAST Elastic ELEC Electric ELEV Elevation ELL Elbow EMERG Emergency ENCL Enclose, Enclosure ENGR Engineer ENT Entrance EQ Equal EQUIP Equipment EST Estimate EW Each Way EWC Electric Water Cooler EXC Excavate EXIST Existing EXP Exposed EXPAN Expansion EXT Exterior, Extension F Fahrenheit F to F Face to Face FA Fire Alarm FAI Fresh Air Intake FB Face Brick FBD Fiberboard FD Floor Drain FDC Fire Department Connection FDTN Foundation FE Fire Extinguisher FEC Fire Extinguisher FED Federal FF Finish Floor FG Fixed Glass FGL Fiberglass FH Fire Hose FHC Fire Hose Cabinet FHR Fire Hose Rack FHYD Fire Hydrant FIN Finish FIXT Fixture FLEX Flexible FLG Flashing FLR Floor FLRG Flooring FLUOR Fluorescent FOC Face of Concrete FOF Face of Finish FOM Face of Masonry FOS Face of Stud FOSTL Face of Steel FP Fireproof FPG Fireproofing FPL Floor Plate FPM Feet per Minute FPS Feet per Second FRM Frame FRMD Framed FRPL Fireplace FRT Fire Retardant Treated FS Full Size FT Foot, Feet FTG Footing FURN Furnish FURR Furring FW Full Width FWC Fabric Wall Covering G Gas GA Gauge GAL Gallon PVG Paving PVMT Pavement PWR Power QLTY Quality QT Quarry Tile QTB Quarry Tile Base QTF Quarry Tile Floor QTR Quarter QTY Quantity R Radius, Riser RAG Return Air Grill RAI Return Air Intake RB Rubber Base RCP Reinforced Concrete Pipe, Reflected Ceiling Plan RD Roof Drain RE Refer, Reference RECIR Re-circulate RECP Receptacle RECT Rectangle RED Reducer REFG Refrigerator REG Register, Regulator REINF Reinforce REPRO Reproduce REQD Required REQS Requirements RESIL Resilient RESIS Resistant RET Return RETG Retaining REV Revise, Revision RFG Roofing RFL Reflect(ed), (ive), (or) RFS Room Finish Schedule RH Right Hand RHR Right Hand Reverse RM Room RND Round RO Rough Opening ROW Right of Way RR Railroad RTG Rating RV Roof Vent RVS Reverse RWL Rainwater Leader S South S&S Stained & Sealed SAFB Sound Attenuation Fire Blanket SAG Supply Air Grille SC Solid Core SCHD Schedule SCRN Screen SD Storm Drain SEC Second SECT Section SEP Separate SERV Service SF, SFT Square Foot SFTY Safety SH Shelf, Shelves, Shelving SHT Sheet SHTHG Sheathing SHWR Shower SIM Similar SKLT Skylight SLNT Sealant SM Smooth SND Sanitary Napkin Dispenser SNK Sink SNR Sanitary Napkin Receptacle SP Stand Pipe SPEC(S) Specification(s) SPECD Specified SPKR Speaker SQ Square SS Standing Seam SSK Services Sink SSMH Sanitary Sewer Man Hole SSTL Stainless Steel ST Street STA Station STAG Staggered STD Standard STER Sterilizer STG Seating STIFF Stiffener STL Steel STOR Storage STR Structure(al) SUB Substitute SUP Supply, Support SUPP Supplement SUPT Superintendent SUR Surface SUS Suspend(ed) SVIN Sheet Vinyl SW Switch SWBD Switch Board SWK Sidewalk SYM Symmetrical SYS System T Tread T&B Top and Bottom T&G Tongue and Groove TANG Tangent TB Towel Bar TC Terra Cotta TD Towel Dispenser TDR Towel Dispenser with Receptacle TECH Technical TECHS Technicians TEL Telephone TEMP Temporary, Temperature TEMPER Tempered THD Thread THERMO Thermostat THK Thick(ness) THR Threshold THRU Through TKBD Tack Board TKPNL Tack Panel TOB Top of Beam TOC Top of Curb TOCD Top of Concrete Deck TOIL Toilet TOL Tolerance TOM Top of Masonry TOPL Top of Plate TOS Top of Slab TOST Top of Steel TOW Top of Wall TP Yield Point TPD Toilet Paper Dispenser TPH Toilet Paper Hanger TPTN Toilet Partition TR Transformer TREAT Treatment TRMPL Template TRR Terrazzo TRTD Treated TV Television TXT Texture(d) TYP Typical U/C Under Cut UC Under Counter UGRND Underground UH Unit Heater UL Underwriters Laboratories, Inc. ULT Ultimate UNFIN Unfinished UNI Unistrut UNO Unless Noted Otherwise UR Urinal UTIL Utility V Valve VA Vacuum VAR Variable VB Vapor Barrier VBX Valve Box VCT Vinyl Composition Tile VENT Ventilator VERT Vertical VEST Vestibule VIF Verify in Field VIN Vinyl VIT Vitreous VJ V-Jointed VNB Vinyl Base VNR Veneer VOL Volume VP Veneer Plaster VTR Vent Thru Roof VWC Vinyl Wall Covering W West, Width W/ With W/O Without WB Wood Base WC Water Closet WCAB Wall Cabinet WCH Wheelchair WD Wood WG Wire Glass WH Water Heater WHSE Warehouse WIN Window WL Water Line WM Wire Mesh WP Waterproofing WPT Working Point WR Waste Receptacle WRST Water Resistant WS Weather Stripping WSCT Wainscot WT Weight WWF Welded Wire Fabric YD Yard YS Yield Strength GALV Galvanized GB Grab Bar GC General Contractor GEN General GFRC Glass Fiber Reinforced Concrete GFRG Glass Fiber Reinforced Gypsum GI Galvanized Iron GL Glass, Glazed GLOPG Glass Opening GOVT Government GPM Gallons per Minute GR Grade GRDG Grading GST Glazed Structural Tile GWB Gypsum Wall Board H/C Handicap H2O Water HB Hose Bibb HC Hollow Core HDB Hard Board HDR Header HDRL Hand Rail HDWR Hardware HEX Hexagonal HJT Head Joint HM Hollow Metal HORZ Horizontal HP Horse Power HPT High Point HR Hour HT Height HTG Heating HTR Heater HVAC Heating, Ventilating & Air Condition. HVY Heavy HWC Handicapped Water Closet HWD Hardwood HWH Hot Water Heater HWY Highway ID Inside Diameter IMPR Impregnate IN Inch, Inches INC Incorporate(d) INCL Include(d), Including IND Industrial INFO Information INSUL Insulate, Insulation INT Interior, Internal INV Invert IPS Inside Pipe Size ISOL Isolation JAN Janitor JCT Junction JST Joist JT Joint K/O Knock Out KD Knock Down KIT Kitchen KPL Kick Plate L Length LAB Laboratory LAM Laminated LAT Lateral, Latitude LAV Lavatory LB Pound LBL Label LBR Lumber LCC Lead Coated Copper LDG Landing LF Linear Foot LG Long LGC Liquid Glaze Coating LH Left hand LHR Left Hand Reverse LINFT Linear Feet LIQ Liquid LKR Locker LL Live Load LP Liquid Propane LPT Low Point LT Light LTL Lintel LTWT Lightweight LVR Louver LWC Light Weight Concrete M Thousand MACH Machine MARB Marble MAS Masonry MATL Material MAX Maximum MC Medicine Cabinet MCW Metal Casework MECH Mechanical MED Medium MEMB Membrane MEMO Memorandum MEZZ Mezzanine MFD Manufactured MFG Manufacturing MFR Manufacturer MG Motor Generator MH Man Hole MIN Minimum MIR Mirror MIR/SH Mirror with Shelf MISC Miscellaneous MITR Mitered MK Mark ML Metal Lath MLDG Molding MO Masonry Opening MOD Model, Module MODBIT Modified Bitumen MON Monument, Monitor MPTN Movable Partitions MS Mop Sink MTD Mounted MTG Mounting MTL Metal MULL Mullion MULT Multiple MWK Millwork N North NAT Natural NC Non-corrosive NCX Non-combustible exterior NIC Not in Contract NIP Nipple NO Number NOM Nominal NOR Normal NRC Noise Reduction Coefficient NS Non-slip NTS Not to Scale O to O Out to Out OA Overall OC On Center OD Outside Diameter OF/CI Owner Furn'd/ Contractor Install'd OF/OI Owner Furnished/ Owner Installed OFF Office OH Overhead OPH Opposite Hand OPNG Opening OPP Opposite ORIG Original ORN Ornament OWNREP Owner's Representative OZ Ounce PA Public Address PAR Parallel PARA Paragraph PASS Passage PBD Particle Board PC Piece PCF Pounds per Cubic Foot PCP Pre-cast Concrete Panel PCST Pre-cast PCW Plastic Laminated Casework PED Pedestal PERF Perforate PERIM Perimeter PERM Permanent PERP Perpendicular PHOTO Photograph PKWY Parkway PL Plate PLAM Plastic Laminate PLAS Plaster PLAST Plastic PLAT Platform PLF Pound per Linear Foot PLMG Pluming PLYWD Plywood PNL Panel PNT Paint PNTD Painted POC Point of Curve POL Polish POLY Polyethylene PORT Portable POS Position PPGL Polished Plate Glass PR Pair PREFAB Prefabricated PREFIN Pre-finished PREP Preparation PRKG Parking PROD Product PROJ Projection PROJMGR Project manager PROP Property PRV Pressure Reducing Valve PSF Pound per Square Foot PSI Pound per Square Inch PT Point PTD Paper Towel Dispenser PTN Partition PTR Paper Towel Receptacle PTWD Pressure Treated Wood PVC Polyvinyl Chloride 2212 River Hills Road Austin, TX 78733
DETAIL CALLOUT. THIS SYMBOL INDICATES DETAIL DRAWING #1 ON SHEET A9.1.
AutoCAD SHX Text
WALL CALLOUT. THIS SYMBOL INDICATES A WALL WHICH IS FURTHER DESCRIBED ON THE WALL SECTION SHEET.
AutoCAD SHX Text
RISE/RUN CALLOUT. THIS SYMBOL INDICATES THE NUMBER OF INCHES OF THE SLOPES RISE (HERE 4") OVER THE SLOPES RUN (HERE 12").
AutoCAD SHX Text
WINDOW CALLOUT. THIS SYMBOL INDICATES A WINDOW WHICH IS FURTHER DESCRIBED WITHIN THE WINDOW SCHEDULE SHEET.
AutoCAD SHX Text
DOOR CALLOUT. THIS SYMBOL INDICATES A DOOR WHICH IS FURTHER DESCRIBED WITHIN THE DOOR SCHEDULE SHEET.
AutoCAD SHX Text
ELEVATION HEIGHT MARKER. THIS SYMBOL CALLS OUT A HEIGHT WHICH CORRESPONDS TO THE TOP OF THE ROOF.
AutoCAD SHX Text
1
AutoCAD SHX Text
A9.1
AutoCAD SHX Text
BREAK MARK.
AutoCAD SHX Text
MATCH LINE.
AutoCAD SHX Text
W1
AutoCAD SHX Text
4
AutoCAD SHX Text
12
AutoCAD SHX Text
A
AutoCAD SHX Text
D1
AutoCAD SHX Text
RIGID INSULATION
AutoCAD SHX Text
STEEL/OTHER METALS
AutoCAD SHX Text
STUCCO
AutoCAD SHX Text
INTERIOR ELEVATION CALLOUT. THIS SYMBOL INDICATES INTERIOR ELEVATION DRAWINGS #1-#4 ON SHEET A7.1.
AutoCAD SHX Text
SECTION CALLOUT. THIS SYMBOL INDICATES SECTION CUT DRAWING #8 ON SHEET A9.1.
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
EXTERIOR ELEVATION CALLOUT. THIS SYMBOL POINTS TO VIEW #1 ON SHEET A3.1
AutoCAD SHX Text
3
AutoCAD SHX Text
A7.1
AutoCAD SHX Text
1
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
2
AutoCAD SHX Text
4
AutoCAD SHX Text
1
AutoCAD SHX Text
SYMBOLS:
AutoCAD SHX Text
SYMBOL:
AutoCAD SHX Text
1
AutoCAD SHX Text
A3.1
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
BRICK (PLAN)
AutoCAD SHX Text
EARTH
AutoCAD SHX Text
COMPACT FILL
AutoCAD SHX Text
CONCRETE MASONRY UNIT (CMU)
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
FINISH WOOD
AutoCAD SHX Text
PROJECT DATA:
AutoCAD SHX Text
PLYWOOD SHEATHING
AutoCAD SHX Text
MASONRY (ELEVATION)
AutoCAD SHX Text
BRICK (ELEVATION)
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
GLASS
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
SLOPE FINISH GRADING AWAY FROM ALL BUILDING FACES TO PROVIDE POSITIVE DRAINAGE . ALL TREES AT THE SITE, EXCEPT THOSE SPECIFICALLY DESIGNATED FOR REMOVAL, ARE TO BE PROTECTED. VEHICLES MAY NOT UNDER ANY CIRCUMSTANCES ENTER THE AREA WITHIN THE DRIP LINE OF A TREE, NOR MAY ANY MATERIALS BE EVEN TEMPORARILY STORED IN THE AREA WITHIN THE DRIP LINE OF A TREE. WRITTEN DIMENSIONS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY IN THE FIELD AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS PRIOR TO FABRICATION AND CONSTRUCTION, AND CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THE DRAWINGS PRIOR TO COMMENCING WORK. SHOP DETAILS SHALL BE SUBMITTED TO OWNER FOR APPROVAL PRIOR TO FABRICATION. REFER TO SPECIFICATIONS FOR INFORMATION NOT SHOWN IN DRAWINGS. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SAFETY PRECAUTIONS, METHODS, SEQUENCES, AND PROCEDURES REQUIRED TO PERFORM THE WORK. ALL WORK, MATERIALS, AND METHODS SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, REGULATIONS, LAWS, AND AGENCIES. CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK AMONG ALL TRADES TO ASSURE A SMOOTH AND HARMONIOUS FLOW OF WORK ON THE JOB. CONTRACTOR SHALL, PRIOR TO BEGINNING FOUNDATION WORK, COORDINATE EXACT LOCATION OF STRUCTURES AT THE SITE WITH OWNER AND ARCHITECT. CONTACT ARCHITECT FOR APPARENT CONTRADICTION OF DRAWINGS AND OR DETAILS. CONTACT ARCHITECT FOR ANY CLARIFICATIONS OF DRAWINGS. GENERAL CONTRACTOR TO CONFIRM WHAT SUBMITTALS AND SAMPLES ARE REQUIRED TO BE REVIEWED AND APPROVED BY OWNER PRIOR TO WORKING.
AutoCAD SHX Text
MASONRY (PLAN)
AutoCAD SHX Text
STEEL LINTEL CALLOUT. THIS SYMBOL INDICATES A STEEL LINTEL WHICH IS FURTHER DESCRIBED WITHIN THE STEEL LINTEL SCHEDULE SHEET.
AutoCAD SHX Text
8
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
A2.2
AutoCAD SHX Text
SECTIONS AND DETAILS
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
ROOF FRAMING PLAN
AutoCAD SHX Text
DRAWING INDEX:
AutoCAD SHX Text
A2.4
AutoCAD SHX Text
A2.3
AutoCAD SHX Text
ELECTRICAL PLAN
AutoCAD SHX Text
TOTAL SQUARE FOOTAGE OF HOUSE: 2,917 S.F. 2,917 S.F. 2,917 S.F. MAIN FLOOR not INCLUDING THE SCREENED IN PORCH 2,685 S.F. SCREENED IN PORCH 232 S.F. 232 S.F. TOTAL A.C. SQUARE FOOTAGE 2,685 S.F. 2,685 S.F.
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text
A3.1
AutoCAD SHX Text
FOUNDATION PLAN AND DETAILS
AutoCAD SHX Text
S1.1
AutoCAD SHX Text
SITE UTILITY PLAN
AutoCAD SHX Text
A1.2
AutoCAD SHX Text
LOW VOLTAGE PLAN
AutoCAD SHX Text
A2.5
AutoCAD SHX Text
ADD #1 - 08.23.06
AutoCAD SHX Text
1
AutoCAD SHX Text
IMPERVIOUS CALCULATIONS: TOTAL BUILDING COVERAGE: -NEW HOUSE AND EXISTING OUT BUILDINGS: 3534 SQUARE FEET -DRIVEWAY 1705 S.F. -SIDEWALKS AND WALKWAYS 183 S.F. -UNCOVERED PATIOS 2711 S.F. -AC PAD 30 S.F. ----------------- TOTAL COVERAGE 8163 S.F. 8163 S.F. TOTAL LOT 201,792 S.F. TOTAL IMPERVIOUS COVERAGE .04% BUILDING ZONING - LA - LA
B E A R I N G B A S I S
HELD-TO-HELD
AutoCAD SHX Text
0.6'off
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
0.7'off
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
1.1'off
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
1.0'off
AutoCAD SHX Text
20.0'x10.4'
AutoCAD SHX Text
Metal Shed
AutoCAD SHX Text
On Dirt
AutoCAD SHX Text
20.0'x19.5'
AutoCAD SHX Text
Wood Shed
AutoCAD SHX Text
On Conc.
AutoCAD SHX Text
Conc.
AutoCAD SHX Text
On Conc.
AutoCAD SHX Text
Wood
AutoCAD SHX Text
Well House
AutoCAD SHX Text
4.5'x6.0'
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
RIVER HILLS ROAD
AutoCAD SHX Text
Lot 1
AutoCAD SHX Text
Lot 2
AutoCAD SHX Text
7720/663
AutoCAD SHX Text
JOHN M.
AutoCAD SHX Text
AND
AutoCAD SHX Text
Access Easement
AutoCAD SHX Text
Exist. 50' Private
AutoCAD SHX Text
Vol. 6336, Pg. 786
AutoCAD SHX Text
(Per Plat)
AutoCAD SHX Text
Drain. Esm't. (Plat)
AutoCAD SHX Text
40' Drain. Esm't. (Plat)
AutoCAD SHX Text
(Per Plat)
AutoCAD SHX Text
& Drainage Esm't.
AutoCAD SHX Text
Year Flood Plain
AutoCAD SHX Text
Limits of 100
AutoCAD SHX Text
Centerline of Eanes Creek
AutoCAD SHX Text
25' B.L. (Plat)
AutoCAD SHX Text
Limits of 100 Year
AutoCAD SHX Text
Fllod Plain (Plat)
AutoCAD SHX Text
(111.81')
AutoCAD SHX Text
10' P.U.E. (Plat)
AutoCAD SHX Text
B.L.
AutoCAD SHX Text
(Plat)
AutoCAD SHX Text
Wall
AutoCAD SHX Text
Rock
AutoCAD SHX Text
(N 84°09'00" W 178.83')
AutoCAD SHX Text
(S 87°45'00" W 73.50')
AutoCAD SHX Text
(N 88°41'00" W 361.92')
AutoCAD SHX Text
(N 81°19'00" E 163.00')
AutoCAD SHX Text
(N 72°40'00" E 172.00')
AutoCAD SHX Text
(S 85°59'00" E 331.90')
AutoCAD SHX Text
(N 87°45'00" E 74.97')
AutoCAD SHX Text
(S 84°09'00" E 184.00')
AutoCAD SHX Text
(S 80°25'00" E 111.30')
AutoCAD SHX Text
(N 86°38'00" E 149.40')
AutoCAD SHX Text
(N 79°11'00" E 200.00')
AutoCAD SHX Text
(S 01°31'00" W 50.50')
AutoCAD SHX Text
(N 80°25'00" W 116.76')
AutoCAD SHX Text
(S 00°07'00" W 224.86')
AutoCAD SHX Text
0.4'off
AutoCAD SHX Text
(N 77°10'00" W 351.99')
AutoCAD SHX Text
1.1'off
AutoCAD SHX Text
(S 83°50'00" W 363.61')
AutoCAD SHX Text
(N 33°25'00" E 15.15')
AutoCAD SHX Text
(N 25°55'00" E 129.30')
AutoCAD SHX Text
Dirt Driveway
AutoCAD SHX Text
94.8'
AutoCAD SHX Text
76.0'
AutoCAD SHX Text
95.0'
AutoCAD SHX Text
94.3'
AutoCAD SHX Text
136.0'
AutoCAD SHX Text
139.4'
AutoCAD SHX Text
77/181
AutoCAD SHX Text
INUNDATED BY THE WATERS OF EANES CREEK
AutoCAD SHX Text
KATHERYN BERARDON
AutoCAD SHX Text
EXISTING SEPTIC FIELD TO REMAIN
AutoCAD SHX Text
EXISTING SEPTIC FIELD TO REMAIN
AutoCAD SHX Text
EXISTING PARKING
AutoCAD SHX Text
25'-0" SIDE YARD SET BACK
AutoCAD SHX Text
40'-0" FRONT YARD SET BACK
AutoCAD SHX Text
NEW HOUSE
AutoCAD SHX Text
25'-0" SIDE YARD SET BACK
AutoCAD SHX Text
24" DIA ELM TREES
AutoCAD SHX Text
21" DIA PECAN TREES
AutoCAD SHX Text
23" DIA SYCAMORE TREE
AutoCAD SHX Text
20" DIA PECAN TREES
AutoCAD SHX Text
36" DIA OAK TREES
AutoCAD SHX Text
EXISTING PATIO
AutoCAD SHX Text
EXISTING PATIO
AutoCAD SHX Text
25'-0" SIDE YARD SET BACK
AutoCAD SHX Text
Subject to Restrictions as Stated in: Vol. 930, Pg. 527 and Per Plat in Book 77, Pg. 181.
AutoCAD SHX Text
BLOCK:
AutoCAD SHX Text
SUBDIVISION
AutoCAD SHX Text
LOT:
AutoCAD SHX Text
COUNTY:
AutoCAD SHX Text
CITY:
AutoCAD SHX Text
1
AutoCAD SHX Text
TRAVIS
AutoCAD SHX Text
AUSTIN
AutoCAD SHX Text
DEER CREEK
AutoCAD SHX Text
BOOK
AutoCAD SHX Text
STREET ADDRESS
AutoCAD SHX Text
REFERENCE NAME
AutoCAD SHX Text
STATE OF TEXAS
AutoCAD SHX Text
77
AutoCAD SHX Text
2212 RIVER HILLS ROAD
AutoCAD SHX Text
WILLIAM J. DAMEO and DIANE DAMEO
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
PLAT RECORDS
AutoCAD SHX Text
181
AutoCAD SHX Text
08.24.06
AutoCAD SHX Text
A1.1
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
1'-0" = 60'-0"
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
HOUSE LOCATION
AutoCAD SHX Text
AHU #2
AutoCAD SHX Text
AHU #1
AutoCAD SHX Text
W/D
AutoCAD SHX Text
SHELVES
AutoCAD SHX Text
2868
AutoCAD SHX Text
2868
AutoCAD SHX Text
CUSTOM GLASS
AutoCAD SHX Text
POCKET
AutoCAD SHX Text
2240
AutoCAD SHX Text
2868
AutoCAD SHX Text
3068
AutoCAD SHX Text
3068
AutoCAD SHX Text
POCKET
AutoCAD SHX Text
SLIDER 12068
AutoCAD SHX Text
LIVING ROOM CONCRETE
AutoCAD SHX Text
DINING ROOM CONCRETE
AutoCAD SHX Text
KITCHEN CONCRETE
AutoCAD SHX Text
GALLERY CONCRETE
AutoCAD SHX Text
SCREENED-IN PORCH CONCRETE
AutoCAD SHX Text
BEDRM.#2/OFFICE WOOD
AutoCAD SHX Text
BEDRM. #3 WOOD
AutoCAD SHX Text
B. RM. CONCRETE
AutoCAD SHX Text
M. BEDRM. WOOD
AutoCAD SHX Text
MECH. RM. CONCRETE
AutoCAD SHX Text
M. BATHRM. TILE
AutoCAD SHX Text
1/2BATH. BATH. TILE
AutoCAD SHX Text
SLIDER 8068 W/TRANSOM 8020
AutoCAD SHX Text
H.B.
AutoCAD SHX Text
H.B.
AutoCAD SHX Text
W.H. #1
AutoCAD SHX Text
W.H. #2
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
SLIDER 6020
AutoCAD SHX Text
SLIDER 8068
AutoCAD SHX Text
SLIDER 6020
AutoCAD SHX Text
AWNING 3028
AutoCAD SHX Text
AWNING
AutoCAD SHX Text
VERIFY - EGRESS W/MANUFACTURE
AutoCAD SHX Text
SLIDER 6020
AutoCAD SHX Text
SLIDER 6020
AutoCAD SHX Text
AWNING 3028
AutoCAD SHX Text
SLIDER 8068
AutoCAD SHX Text
SLIDER 8068
AutoCAD SHX Text
FIXED 8020
AutoCAD SHX Text
FIXED 8020
AutoCAD SHX Text
(ELFA- MANUFACTURER)
AutoCAD SHX Text
SECONDARY DRAINLINE FOR AHU #1 AND WH #1 TO MAIN DRAIN
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
NEW STEPS, G.C. TO VERIFY HEIGHT AND NUMBER OF STEPS, TYP.-12" TREAD/7"RISERS
AutoCAD SHX Text
DN
AutoCAD SHX Text
CUT BACK EXISTING RETAINING WALLL AND COORDINATE NEW WALL AND FOUNDATION
AutoCAD SHX Text
2X4WALL
AutoCAD SHX Text
2X4WALL
AutoCAD SHX Text
2X4WALL
AutoCAD SHX Text
2X4WALL
AutoCAD SHX Text
2X4WALL
AutoCAD SHX Text
2X4WALL - 8'-0" TALL
AutoCAD SHX Text
HALLWAY WOOD
AutoCAD SHX Text
FIX 5220 (VIF W/STL. TRUSS/ELEV. 2/A3.1
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
MAIN DRAIN LINE
AutoCAD SHX Text
FLATWORK, G.C. TO VERIFY SIZE SLOPE TO DRAIN " PER FOOT18" PER FOOT
STONE WALL PER OWNER (STACK STONE) TO MEET W/EXISTING ROCK WALL 16'-0" +/- TO THE EAST
AutoCAD SHX Text
(2) AC UNITS, G.C. TO VERIFY SIZE AND FINAL LOCATION
AutoCAD SHX Text
6" CURB 24" OPENING
AutoCAD SHX Text
8.5"x12" DOG DOOR
AutoCAD SHX Text
HALF DOOR W/PUSH LATCH HARDWARE, PAINT TO MATCH WALL - OPEN WOOD SHELVES ABOVE, TYP.
AutoCAD SHX Text
T.O.W. 6'-8" CAP W/TILE
AutoCAD SHX Text
6" CURB
AutoCAD SHX Text
WATER FROM WELL
AutoCAD SHX Text
WATER FROM WELL
AutoCAD SHX Text
T.O.W. 6'-8" CAP W/TILE
AutoCAD SHX Text
ROOM NAME
AutoCAD SHX Text
FLOORS
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
GALLERY
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
EXPOSED TRUSSES
AutoCAD SHX Text
LIVING ROOM
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
EXPOSED TRUSSES
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
EXPOSED TRUSSES
AutoCAD SHX Text
DINING ROOM
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
EXPOSED TRUSSES
AutoCAD SHX Text
MASTER BATH
AutoCAD SHX Text
MR GWB/TILE
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
GWB
AutoCAD SHX Text
GWB
AutoCAD SHX Text
GWB
AutoCAD SHX Text
GWB
AutoCAD SHX Text
CONCRETE - SEE OWNER, SHOWER TILE
AutoCAD SHX Text
MASTER BED
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
GWB
AutoCAD SHX Text
SCREENED PATIO
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
BOARD & BATTEN
AutoCAD SHX Text
T&G CEDAR
AutoCAD SHX Text
CEILING - CLR. SEAL
AutoCAD SHX Text
WALK-IN-CLOSET
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
EXPOSED STL
AutoCAD SHX Text
OFFICE/BEDRM
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
GWB
AutoCAD SHX Text
BATH 2
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
WOOD WILL BE USED AS BASEBOARD, TILE IN SHOWER
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
BED 2
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
GWB
AutoCAD SHX Text
12 BATH
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
MR GWB
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
IN ALL BATHROOMS TRIM WILL BE PAINTED WOOD, TYP. ALL TILE WILL BE AMERICAN OLEAN UNGLAZED MOSAIC SQUARE 1X1 RANDOM PATTERN. ALL GROUT TO BE LATICRETE SPECTRA LOCK. ALL SHOWERS WILL BE TILE, REF. OWNER/G.C. ALL WALLS/CEILINGS SHALL BE MOISTURE RESISTANT GYPSUM BOARD (MR GWB) IN BATHROOMS AND LAUNDRY ONLY ALL WOOD FLOORING SHALL BE T&G " ELM FBO 34" ELM FBO ALL CONCRETE FLOORS SHALL BE GROUND SMOOTH AND SEALED ALL TRIM WILL BE PINE (FBO) PAINTED AND MAPLE DOORS WILL BE CLEAR SEALED GRINDING OF CONCRETE BY AMERICAN CONCRETE TECHNOLOGIES AND OR APPROVED EQAUL
AutoCAD SHX Text
ROOM FINISH SCHEDULE
AutoCAD SHX Text
FINISHED MAPLE PLYWOOD " THICK IN CEILING BAY14" THICK IN CEILING BAY
AutoCAD SHX Text
FINISHED MAPLE PLYWOOD " THICK IN CEILING BAY14" THICK IN CEILING BAY
AutoCAD SHX Text
FINISHED MAPLE PLYWOOD " THICK IN CEILING BAY14" THICK IN CEILING BAY
AutoCAD SHX Text
FINISHED MAPLE PLYWOOD " THICK IN CEILING BAY14" THICK IN CEILING BAY
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
GWB
AutoCAD SHX Text
FINISHED MAPLE PLYWOOD " THICK IN CEILING BAY14" THICK IN CEILING BAY
AutoCAD SHX Text
EXPOSED STL
AutoCAD SHX Text
FINISHED MAPLE PLYWOOD " THICK IN CEILING BAY14" THICK IN CEILING BAY
AutoCAD SHX Text
GYPSUM WALLBOARD IN CEILING BAY
AutoCAD SHX Text
EXPOSED STL
AutoCAD SHX Text
GYPSUM WALLBOARD IN CEILING BAY
AutoCAD SHX Text
EXPOSED STL
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. ALL EXTERIOR WALLS AND PLUMBING WALLS ARE 2X6, TYP. 2. CONTRACTOR TO COORDINATE W/OWNER REGARDING THE STEPS FROM THE SCREENED IN PORCH. STEPS ARE PER CODE. STONE IS TO BE REUSED, SEE OWNER. 3. GRANITE COUNTERTOPS ARE IN THE KITCHEN, AND ALL BATHROOMS, OWNER TO CHOOSE SAMPLE 4. VERIFY ALL LOCATIONS OF BATHROOM ACCESSORIES W/OWNER. 5. ALL TILE IN BATHROOMS WILL ALIGN W/THE TOP OF THE WOOD TRIM @ THE DOORS AND WINDOWS, TYP. ALL WALLS THAT HAVE TILE ON THEM SHALL HAVE A TILE CAP. 6. ALL CABINETRY BY OWNER AND INSTALLED BY GENERAL CONTRACTOR 7. G.C. TO COORDINATE FINISH FLOOR ELEVATIONS. 8. ALL HOSE BIBS SHALL BE FREEZE-PROOF, TYP.
AutoCAD SHX Text
08.24.06
AutoCAD SHX Text
A2.1
AutoCAD SHX Text
MAIN FLOOR PLAN
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
MAIN FLOOR PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
ADD #1 - 08.23.06
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
PLUG STRIP
AutoCAD SHX Text
PLUG STRIP
AutoCAD SHX Text
PLUG STRIP
AutoCAD SHX Text
ELECT. PANEL
AutoCAD SHX Text
WIRING PANEL
AutoCAD SHX Text
3
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
E
AutoCAD SHX Text
M
AutoCAD SHX Text
F
AutoCAD SHX Text
M
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
GFIC
AutoCAD SHX Text
GFIC
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
G
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
J
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
H
AutoCAD SHX Text
G
AutoCAD SHX Text
GFIC
AutoCAD SHX Text
WP
AutoCAD SHX Text
I
AutoCAD SHX Text
I
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
J
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
WP
AutoCAD SHX Text
GFIC
AutoCAD SHX Text
GFIC
AutoCAD SHX Text
GFIC
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
F
AutoCAD SHX Text
EE
AutoCAD SHX Text
K
AutoCAD SHX Text
K
AutoCAD SHX Text
K
AutoCAD SHX Text
LIGHT LOCATIONG- NEX TO STEP, VERIFY WITH OWNER
AutoCAD SHX Text
LIGHT LOCATION PER OWNER
AutoCAD SHX Text
LIGHT LOCATION PER OWNER
AutoCAD SHX Text
P
AutoCAD SHX Text
LIGHT LOCATION PER OWNER
AutoCAD SHX Text
J
AutoCAD SHX Text
J
AutoCAD SHX Text
EE
AutoCAD SHX Text
EE
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
(1) 20 AMP CIRCUIT
AutoCAD SHX Text
(1) 20 AMP CIRCUIT BEHIND TV, G.C. TO TO COORDINATE LOCATION, TYP.
AutoCAD SHX Text
POWER IN MILLWORK
AutoCAD SHX Text
220
AutoCAD SHX Text
SEPTIC PUMP AND ALARM POWER FROM HOUSE TO ALARM PANEL IN MECH. RM., G.C. TO COORDINATE
AutoCAD SHX Text
WATER
AutoCAD SHX Text
WP
AutoCAD SHX Text
WP
AutoCAD SHX Text
WP
AutoCAD SHX Text
WP
AutoCAD SHX Text
SEPTIC ALARM/ PANEL
AutoCAD SHX Text
POWER FOR JET TUB, G.C. TO COOR. POWER LOCATION, TYP.
AutoCAD SHX Text
G
AutoCAD SHX Text
F
AutoCAD SHX Text
I
AutoCAD SHX Text
I
AutoCAD SHX Text
3
AutoCAD SHX Text
Q
AutoCAD SHX Text
Q
AutoCAD SHX Text
Q
AutoCAD SHX Text
Q
AutoCAD SHX Text
EE
AutoCAD SHX Text
FLOOR MOUNT FIXTURE AS CLOSE TO WALL AS POSSIBLE
AutoCAD SHX Text
MOUNTED ABOVE LIGHT FIXTURE W/IN TRUSS, REF. TO OWNER
AutoCAD SHX Text
MOUNT W/IN TRUSS TYP., REF. TO OWNER
AutoCAD SHX Text
A - LITHONIA 2 LIGHT F34T12 - MODEL# C240 E5
AutoCAD SHX Text
C - SPIRO MODEL 516 PENDANT FIXTURE, MODEL# FB0 MOUNTED TO " EMT TREADED CONDUIT34" EMT TREADED CONDUIT
AutoCAD SHX Text
D - SURFACE MOUNT PULL CHAIN FIXTURE
AutoCAD SHX Text
E - CEILING FAN/LIGHT
AutoCAD SHX Text
F - WALL SCONCE
AutoCAD SHX Text
G - NUTRON COMBINATION FAN
AutoCAD SHX Text
H - HALO AIRTIGHT 4" RECESSED CEILING W/SHOWER LENS FIXTURE
AutoCAD SHX Text
I - HALO TRACK HEAD ON NONOPOINT ADAPTER - WATER PROOF FIXTURE AT ALL BATHROOM LOCATIONS
AutoCAD SHX Text
J- HALO TRACK SINGLE CIRCUIT TRACK
AutoCAD SHX Text
K - 250 WATT METAL HALIDE OUTDOOR FIXTURE ALL LIGHTS ON DAYLIGHT SENSORS
AutoCAD SHX Text
M - CEILING MOUNT FIXTURE
AutoCAD SHX Text
N - EXTERIOR GRADE JELLY-JAR FIXTURE
AutoCAD SHX Text
S
AutoCAD SHX Text
O - SMOKE DETECTOR
AutoCAD SHX Text
- DUPLEX OUTLET UNLESS NOTED
AutoCAD SHX Text
P - POLE MOUNT LIGHT FIXTURE
AutoCAD SHX Text
EE - CEILING FAN ONLY
AutoCAD SHX Text
- SWITCH PLATE
AutoCAD SHX Text
Q - EXTERIOR SURFACE MOUNT FIXTURE BOTTOM OF FIXTURE LOCATED 6'-8" A.F.F.
AutoCAD SHX Text
1
AutoCAD SHX Text
MAIN FLOOR POWER PLAN AND LIGHTING PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. INSTALL ALL ELECTRICAL SWITCHES, OUTLETS, DEVICES, AND EQUIPMENT PER THE UBC 2000. IN AREAS WHERE THERE ARE EXPOSED TRUSSES ALL WIRES WILL BE IN CONDUIT AND COORDINATED W/OTHER TRADES AND G.C. TO MAKE AN ORDERLY ARRANGEMENT, TYP. 2. OWNER TO PROVIDE ALL LIGHT FIXTURES AND EQUIPMENT TO G.C.. 3. G.C. TO COORDINATE ANY IN SLAB UTILITIES AS NEEDED. 4. OWNER AND G.C. TO COORDINATE ALL SPEAKER WIRE AND CONTROL LOCATIONS. 5. DIMMER SWITCHES LOCATED AT 1. MASTER BEDROOM, 2. MASTER BATHROOM, 3. KITCHEN, 4. DINING ROOM, 5. LIVING ROOM, 6. GALLERY, 7. OFFICE/BEDROOM. 6. ALL FIXTURES ARE CENTERED W/IN THE ROOM. 2X2X " STL. ANGLES 14" STL. ANGLES WELDED TO TOP OF BOTTOM CHORD OF TRUSSES TO SUPPORT FANS OR LIGHTS, TYP. G.C. TO COORDINATE LOCATONS
AutoCAD SHX Text
08.24.06
AutoCAD SHX Text
A2.2
AutoCAD SHX Text
MAIN FLOOR
AutoCAD SHX Text
ELECTRICAL PLAN
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
LIGHT SCHEDULE
AutoCAD SHX Text
ADD #1 - 08.23.06
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
GUTTER, TYP.
AutoCAD SHX Text
EDGE OF PARAPET WALL, TYP.
AutoCAD SHX Text
DOWN SPOUT TO LOWER ROOF, TYP.
AutoCAD SHX Text
DOWN SPOUTS, TYP.
AutoCAD SHX Text
EDGE OF PARAPET WALL, TYP.
AutoCAD SHX Text
LINE OF WALL BELOW, TYP.
AutoCAD SHX Text
EDGE OF PARAPET WALL, TYP.
AutoCAD SHX Text
METAL ROOF, TYP.
AutoCAD SHX Text
METAL ROOF, TYP.
AutoCAD SHX Text
METAL ROOF, TYP.
AutoCAD SHX Text
METAL ROOF, TYP.
AutoCAD SHX Text
LINE OF WALL BELOW,TYP.
AutoCAD SHX Text
LINE OF WALL BELOW,TYP.
AutoCAD SHX Text
LINE OF WALL BELOW,TYP.
AutoCAD SHX Text
LINE OF WALL BELOW, TYP.
AutoCAD SHX Text
AWNING OVER DOOR PER OWNER
AutoCAD SHX Text
AWNING OVER DOOR
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
DOWN SPOUT, TYP.
AutoCAD SHX Text
DOWN SPOUT, TYP.
AutoCAD SHX Text
2
AutoCAD SHX Text
A2.3
AutoCAD SHX Text
2
AutoCAD SHX Text
A2.3
AutoCAD SHX Text
2
AutoCAD SHX Text
A2.3
AutoCAD SHX Text
2
AutoCAD SHX Text
A2.3
AutoCAD SHX Text
OPP.
AutoCAD SHX Text
OPP.
AutoCAD SHX Text
AWNING UNDER ROOF OVERHANG SLOPE " PER FOOT116" PER FOOT
AutoCAD SHX Text
ROOF BEYOND
AutoCAD SHX Text
STUCCO WALL
AutoCAD SHX Text
6" GUTTER
AutoCAD SHX Text
4" ROUND DOWN SPOUT
AutoCAD SHX Text
WATER COLLECTION COLLAR W/MESH SCREEN G.C. TO VERIFY THAT COLAR ELEVATION HIGHER THEN TANK FILL ELEVATION
AutoCAD SHX Text
4" PVC - RUN TO WATER COLLECTION WRAP PLASTIC DOWNSPOUT TO MATCH 4" DOWN SPOUT ABOVE, TYP.
AutoCAD SHX Text
NOTE: -DIAGRAM OF WATER COLLECTION SYSTEM - G.C. TO COORDINATE W/ WATER SPECIALIST- VERIFY ALL MATERIALS AND DETAILS
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. ALL PENETRATIONS SHALL BE ON THE SOUTH SIDE OF THE ROOF. CONTRACTOR TO COORDINATE. 2. ALL GUTTERS ARE 6" GALVALUM BOX SHAPED AND DOWNSPOUTS ARE 4" ROUND GALVALUM, TYP. 3. ALL DOWNSPOUTS SHALL CONNECT TO UNDERGROUND LINE THAT FLOWS TO WATER COLLECTION. G.C. AND OWNER TO COORDINATE ALL UNDERGROUND CONNECTIONS, U.N.O. 4. CONTRACTOR/OWNER TO COORDINATE FINAL LOCATION OF WATER COLLECTION CONTAINER.
AutoCAD SHX Text
08.24.06
AutoCAD SHX Text
A2.3
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
2
AutoCAD SHX Text
WATER COLLECTION DIAGRAM
AutoCAD SHX Text
1/2" = 1'-0"
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
TS 4X4X1/4
AutoCAD SHX Text
BAR JOIST: 14'- " DEPTH 14" DEPTH REFER TO OWNER, G.C. TO VERIFY FINAL LENGTH
AutoCAD SHX Text
W FLANGE 13" DEEP REFER TO OWNER, G.C. TO VERIFY FINAL LENGTH
AutoCAD SHX Text
STEEL ANGLE 4"x4"x3/8"
AutoCAD SHX Text
STEEL ANGLE 4"x7"x3/8"
AutoCAD SHX Text
2-2X12 LVLS
AutoCAD SHX Text
SLOPE TO MATCH MASTER SUITE SO, SIP PANEL ALIGNS
AutoCAD SHX Text
8'6" FINSHED CEILING IN THE HALLYWAY, MECHANICAL ROOM, BATHROOM AND MASTER SUITE, STRUCTURE TO SLOPE
AutoCAD SHX Text
OPEN TO STRUCTURE
AutoCAD SHX Text
WALL TO UNDERSIDE OF DECKING
AutoCAD SHX Text
FURR OUT AREA TO COVER COLUMN
AutoCAD SHX Text
BATHROOM CEILING HEIGHT TO BE LEVEL, MAXIMUM HEIGHT TO ACCOMADATE, STRUCTURE, LIGHTS, ETC... G.C. TO VERIFY
AutoCAD SHX Text
STEEL TRUSS, VERIFY W/OWNER
AutoCAD SHX Text
8" SIP PER MANUFACTURES SPECIFICATIONS, G.C. TO COORDINATE SIZE AND LAYOUT, TYP.
AutoCAD SHX Text
8" SIP PER MANUFACTURES SPECIFICATIONS, G.C. TO COORDINATE SIZE AND LAYOUT, TYP.
AutoCAD SHX Text
8" SIP PER MANUFACTURES SPECIFICATIONS, G.C. TO COORDINATE SIZE, TYP.
AutoCAD SHX Text
TS 8X8X1/4
AutoCAD SHX Text
TS 8X8X1/4
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X4X3/16 (ABOVE)
AutoCAD SHX Text
TS 8X8X1/4
AutoCAD SHX Text
TS 8X4X1/4
AutoCAD SHX Text
4
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
C-CHANNEL BY OWNER, REF. ELEV.
AutoCAD SHX Text
C-CHANNEL BY OWNER, REF. ELEV.
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
TS 8X4X3/16
AutoCAD SHX Text
TS 8X3X3/16 (ABOVE)
AutoCAD SHX Text
TS 2X3X3/16 (TOP)
AutoCAD SHX Text
C-CHANNEL BY OWNER, REF. ELEV.
AutoCAD SHX Text
STEEL ANGLE 4"x7"x3/8"
AutoCAD SHX Text
STEEL ANGLE 4"x4"x3/8"
AutoCAD SHX Text
1
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
ROOF FRAMING MEMBERS: UNLESS OTHERWISE NOTED, ALL FRAMING MEMBERS ARE #2YP SIZED AND SPACED AS FOLLOWS: - RAFTERS - 2X6 @ 24"O.C. - LOOKOUT RAFTERS - 2X4 ON FLAT @ AS SHOWN - HIPS, RIDGES, VALLEYS - 2X8 - PURLINS - 2X6 AS SHOWN - STRUTS - 2X6 @48"O.C. CEILING JOISTS SCHEDULE, IF NEEDED: UNLESS OTHERWISE NOTED, ALL CEILING JOISTS ARE #2YP @ 24" O.C., W/JOISTS SIZES AS FOLLOWS. - 2X4 FOR UP TO 7'-8" SPANS - 2X6 FOR 7'-9' TO 10'-0" SPANS - 2X8 FRO 10'-11" TO 13'-10" SPANS - 2X10 FOR 13'-11" TO 16'-5" SPANS HEADER SCHEDULE; 2-2X4'S = 4' MAX 2-2X6'S = 6' MAX 2-2X8'S = 8' MAX 2-2X10'S = 10' MAX 2-2X12'S = 12' MAX
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. ALL RAFTER TAILS WILL BE 2X6 CEDAR SCABBED ONTO SIP PANELS 2. G.C. TO COORDINATE ALL STRUCTURE 3. PROVIDE BLOCKING IN ALL WALLS FOR PLUMBING, MECHANICAL, ELECTRICAL, MILLWORK AND ALL OTHER HANGING DEVICES, REFER TO OWNER 4. CONTINOUS PHILLET WELDING W/CERTIFICATION BY WELDER 5. ALL LOAD BEARING WALLS TO BE METAL STUD, 16 GUAGE, 6" WIDTH
AutoCAD SHX Text
08.24.06
AutoCAD SHX Text
A2.4
AutoCAD SHX Text
ROOF FRAMING
AutoCAD SHX Text
PLANS
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
1
AutoCAD SHX Text
ROOF FRAMING PLAN
AutoCAD SHX Text
1/14" = 1'-0"
AutoCAD SHX Text
ADD #1 - 08.23.06
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
PLUG STRIP
AutoCAD SHX Text
PLUG STRIP
AutoCAD SHX Text
PLUG STRIP
AutoCAD SHX Text
ELECT. PANEL
AutoCAD SHX Text
WIRING PANEL
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
LIGHT LOCATIONG- NEX TO STEP, VERIFY WITH OWNER
AutoCAD SHX Text
LIGHT LOCATION PER OWNER
AutoCAD SHX Text
LIGHT LOCATION PER OWNER
AutoCAD SHX Text
LIGHT LOCATION PER OWNER
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
(1) 20 AMP CIRCUIT
AutoCAD SHX Text
(1) 20 AMP CIRCUIT BEHIND TV, G.C. TO TO COORDINATE LOCATION, TYP.
AutoCAD SHX Text
POWER IN MILLWORK
AutoCAD SHX Text
SEPTIC PUMP AND ALARM POWER FROM HOUSE TO ALARM PANEL IN MECH. RM., G.C. TO COORDINATE
AutoCAD SHX Text
WATER
AutoCAD SHX Text
SEPTIC ALARM/ PANEL
AutoCAD SHX Text
POWER FOR JET TUB, G.C. TO COOR. POWER LOCATION, TYP.
AutoCAD SHX Text
3
AutoCAD SHX Text
FLOOR MOUNT FIXTURE AS CLOSE TO WALL AS POSSIBLE
AutoCAD SHX Text
MOUNTED ABOVE LIGHT FIXTURE W/IN TRUSS, REF. TO OWNER
AutoCAD SHX Text
MOUNT W/IN TRUSS TYP., REF. TO OWNER
AutoCAD SHX Text
A - LITHONIA 2 LIGHT F34T12 - MODEL# C240 E5
AutoCAD SHX Text
C - SPIRO MODEL 516 PENDANT FIXTURE, MODEL# FB0 MOUNTED TO " EMT TREADED CONDUIT34" EMT TREADED CONDUIT
AutoCAD SHX Text
D - SURFACE MOUNT PULL CHAIN FIXTURE
AutoCAD SHX Text
E - CEILING FAN/LIGHT
AutoCAD SHX Text
F - WALL SCONCE
AutoCAD SHX Text
G - NUTRON COMBINATION FAN
AutoCAD SHX Text
H - HALO AIRTIGHT 4" RECESSED CEILING W/SHOWER LENS FIXTURE
AutoCAD SHX Text
I - HALO TRACK HEAD ON NONOPOINT ADAPTER - WATER PROOF FIXTURE AT ALL BATHROOM LOCATIONS
AutoCAD SHX Text
J- HALO TRACK SINGLE CIRCUIT TRACK
AutoCAD SHX Text
K - 250 WATT METAL HALIDE OUTDOOR FIXTURE ALL LIGHTS ON DAYLIGHT SENSORS
AutoCAD SHX Text
M - CEILING MOUNT FIXTURE
AutoCAD SHX Text
N - EXTERIOR GRADE JELLY-JAR FIXTURE
AutoCAD SHX Text
S
AutoCAD SHX Text
O - SMOKE DETECTOR
AutoCAD SHX Text
- DUPLEX OUTLET UNLESS NOTED
AutoCAD SHX Text
P - POLE MOUNT LIGHT FIXTURE
AutoCAD SHX Text
EE - CEILING FAN ONLY
AutoCAD SHX Text
- SWITCH PLATE
AutoCAD SHX Text
Q - EXTERIOR SURFACE MOUNT FIXTURE BOTTOM OF FIXTURE LOCATED 6'-8" A.F.F.
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1.
AutoCAD SHX Text
07.17.06
AutoCAD SHX Text
A2.5
AutoCAD SHX Text
MAIN FLOOR
AutoCAD SHX Text
LOW VOLTAGE PLAN
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
LIGHT SCHEDULE
AutoCAD SHX Text
1
AutoCAD SHX Text
LOW VOLTAGE PLAN
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text
2X T&G CEDAR CLEAR SEAL, TYP.
AutoCAD SHX Text
CONT. MTL. FLASHING AROUND PARAPET WALL, TYP.
AutoCAD SHX Text
STUCCO
AutoCAD SHX Text
12" C-CHANNEL, CLEANED AND PAINTED, PROVIDED BY OWNER. REF. SECTION FOR ATTACHMENT DETAIL. WELD AND GRIND SMOOTH ATTACHED PIECES FOR REQUIRED LENGTH.
AutoCAD SHX Text
SCREENED IN PORCH, G.C. TO COORDINATE
AutoCAD SHX Text
GERKIN WINDOW SYSTEM
AutoCAD SHX Text
T.O. WALL
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text
T.O.S.
AutoCAD SHX Text
T.O.S.
AutoCAD SHX Text
T.O.S.
AutoCAD SHX Text
STUCCO
AutoCAD SHX Text
STUCCO
AutoCAD SHX Text
SOFFIT
AutoCAD SHX Text
REMOVE ALL OUTSIDE DIAGONAL AND VERTICAL TRUSS MEMBERS TO ACCEPT WINDOW SYSTEM, OWNER TO VERIFY SIZE
AutoCAD SHX Text
METAL ROOF
AutoCAD SHX Text
WIDOW TO ALIGN W/ NORTH FACADE
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
SCREENED IN PORCH, FOLLOW PROFILE OF TRUSS, G.C. TO COORDINATE
AutoCAD SHX Text
BREAK METAL TO FOLLOW CURVE, G.C. TO COORDINATE
AutoCAD SHX Text
TRUSS, PER OWNER
AutoCAD SHX Text
BUILDING BEYOND
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text
REMOVE ALL OUTSIDE DIAGONAL AND VERTICAL TRUSS MEMBERS TO ACCEPT WINDOW SYSTEM, OWNER TO VERIFY SIZE
AutoCAD SHX Text
AWING SIMILIAR DETAIL OVER MASTER SUITE DOOR
AutoCAD SHX Text
MTL. ROOF
AutoCAD SHX Text
MTL. ROOF
AutoCAD SHX Text
AC LOCATION
AutoCAD SHX Text
MTL. ROOF
AutoCAD SHX Text
DOWN SPOUT ATTACHED TO LINES FOR WATER COLLECTION, G.C. TO COORDINATE PROPER SLOPE AND SIZE, TYP.
AutoCAD SHX Text
DOWN SPOUT ATTACHED TO LINES FOR WATER COLLECTION, G.C. TO COORDINATE PROPER SLOPE AND SIZE, TYP.
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text
12" C-CHANNEL, CLEANED AND PAINTED, PROVIDED BY OWNER. REF. SECTION FOR ATTACHMENT DETAIL. WELD AND GRIND SMOOTH ATTACHED PIECES FOR REQUIRED LENGTH.
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
08.24.06
AutoCAD SHX Text
A3.1
AutoCAD SHX Text
ELEVATIONS
AutoCAD SHX Text
SHEET:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT MGR:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHKD. BY:
AutoCAD SHX Text
Fax.
AutoCAD SHX Text
Tel.
AutoCAD SHX Text
(512) 474-8643
AutoCAD SHX Text
(512) 474-8548
AutoCAD SHX Text
Interiors
AutoCAD SHX Text
Project Management
AutoCAD SHX Text
Architecture
AutoCAD SHX Text
Planning
AutoCAD SHX Text
Austin, Texas 78701
AutoCAD SHX Text
702 San Antonio
AutoCAD SHX Text
Hatch Partnership llp
AutoCAD SHX Text
A. I. A.
AutoCAD SHX Text
Architects
AutoCAD SHX Text
DeMeo
AutoCAD SHX Text
Residence
AutoCAD SHX Text
-
AutoCAD SHX Text
LIMITED
AutoCAD SHX Text
-
AutoCAD SHX Text
2212 River Hills Road
AutoCAD SHX Text
Austin, TX 78733
AutoCAD SHX Text
TOM HATCH
AutoCAD SHX Text
DJH
AutoCAD SHX Text
TH
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text
DOCUMENTS
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. DOWNSPOUTS ARE TO BE COORDINATED W/G.C. FOR FINAL COORDINATION OF UNDERGROUND CONNECTIONS. TYP. 2. ALL FLASHING TO BE GALVANIZED
AutoCAD SHX Text
1
AutoCAD SHX Text
NORTH ELEVATION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
3
AutoCAD SHX Text
SOUTH ELEVATION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
2
AutoCAD SHX Text
EAST ELEVATION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
4
AutoCAD SHX Text
WEST ELEVATION
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
12
AutoCAD SHX Text
CONT. MTL. CAP FLASHING TYP. AT ALL PARAPET WALLS
AutoCAD SHX Text
STUCCO
AutoCAD SHX Text
1
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
1X FACIA TRIM PAINTED
AutoCAD SHX Text
CEDAR SOFFIT
AutoCAD SHX Text
1X TRIM
AutoCAD SHX Text
CON'T. 4X4X3/8 STL. ANGLE ATTACHED TO MTL. STUD BEARING PLATE
AutoCAD SHX Text
58" GYP. TO UNDERSIDE OF SIP PANEL, TYP. IN ALL BEDROOMS, PROVIDE J-MOLD TRIM AROUND STRUCTURE
AutoCAD SHX Text
W-FLANGE WELDED TO CON'T. STEEL ANGLE, TYP. G.C. TO COORDINATE LENGTH OF MEMBER - MEMBER TO BE CLEANED AND PAINTED
BASE PLATE TO FOUNDATION CONNECTION NOTE: 34"DIA. x 9" LONG B7 THREADED ROD W/HEX NUT AND WASHER EPOXIED 6" INTO EXISTING FOUNDATION W/RAWL FOILFAST OR HILTI HY-150
AutoCAD SHX Text
J ANCHORS WELDED TO BOTTOM OF PLATE ONLY IN NEW FOUNDATION AREAS - THREADED ROD IN LOCATIONS OF TOPPING SLAB, VERIFY W/G.C.
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. OWNER AND CONTRACTOR TO COORDINATE FINAL LOCATION OF DRIVEWAY AND THE EXACT MATERIAL. 2. OWNER TO DETERMINE FINAL LOCATION FOR RETAINING WALLS, SEE PLANS FOR LOCATION OF RETAINING WALLS AT HOUSE. 3. ALL EXPOSED CONCRETE FLOORS WILL BE STAINED AND SCORED, PER OWNER 4. CONTRACTOR TO VERIFY ALL SLOPES FOR PROPER DRAINAGE.