dau specification (latest)

Upload: kevin-ngo

Post on 23-Feb-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/24/2019 DAU Specification (Latest)

    1/5

    Page 1 of 5

    Specifications

    Data Acquisition Unit

    Description

    The Data Acquisition Unit (DAU) is part of the S8000 Plus System. It

    samples the signal inputs such as rotating speed, vibration, process

    variables, converts them from analog to digital and transfers the data to

    WEB8000 Plus.

    It supports the TCP/IP protocol based on the Ethernet (10M/100M)standard, and transmits data via the enterprise network. In addition it is

    characterized by high speed, high accuracy, high reliability, easy

    installation and connection, maintenance-free.

    Meanwhile, the DAU is the first field acquisition station in the world with

    a WEB function. From a computer on the same network with the DAU, a

    user can view spectrum and other data from the DAU with IE browser.

    According to the application and capacity, there are 6 types of DAU. They

    are NET8000 Plus, NET8000 Dual, PWR8000 Plus, PWR8000 Dual and

    HYD8000 Plus, HYD8000 Dual.

    Type of the DAU

    Application NET8000 Plus

    NET8000 Dual

    PWR8000 Plus

    PWR8000 Dual

    HYD8000 Plus

    HYD8000 Dual

    Rotating

    Speed

    >4000 RPM

    32000 RPM

    >1000RPM

    4000RPM

    !12RPM

    1000RPM

    Industry

    Petroleum

    &chemical,

    Steel & Aluminum

    Coal Fired Power,

    Nuclear PowerHydro Power

    Number of Inputs of the DAU

    Signal Type NET8000 Plus

    PWR8000 Plus

    HYD8000 Plus

    NET8000 Dual

    PWR8000 Dual

    HYD8000 Daul

    Rotating Speed 4 8

    Vibration 24 48

    Hard-Wired Process 12 24

    Figure: PWR8000 Plus

    Figure: PWR8000 Plus Rear View

  • 7/24/2019 DAU Specification (Latest)

    2/5

    Page 2 of 5

    Specifications of DAU

    Inputs

    Power Supply:

    AC220V"10% 50Hz

    AC110V"10% 50Hz

    Power

    Consumption:

    Max. 80 Watts

    Data Port

    (Backboard):

    Max. 19.2kbps Serial Communication (2

    RS232 ports)

    10Base-T/100Base-TEthernet (1 RJ45

    port)

    Outputs

    Front Panel LEDs:

    PWR LED:

    Turn green when the DAU is powered on

    OK LED:Turn green when the DAU is operating

    properly

    LAN LED:

    Turn green if the communication with

    WEB8000 Plus is fine via Ethernet

    COM1 LED:

    Turn green if the communication is fine

    on COM1 port

    COM2 LED:

    Turn green if the communication is fine

    on COM2 port

    K1-K4/K8 LEDs:

    Turn green if the corresponding rotating

    speed signal is normal.

    DYNAMIC

    (1-24/48) LEDs:

    Turn green if the corresponding vibration signal is

    normalSTATIC

    (1-12/24) LEDs:

    Turn green if the corresponding process

    signal is normal

    Communications

    Protocol:

    MODBUS:

    Communication with DCS system to

    obtain process signals

    HTTP:

    Communication with WEB8000 Plus

    server to transmit data

    Backboard

    Communications:

    RS232

    Protocol

    Supported:

    MODBUSBaud Rate:

    Max. 19.2kbps

    Cable Length:

    Max.15meters

    Connector:

    DB9 serial cable

    Backboard

    Communications:

    Ethernet, 10Base-T/100Base-TX

    Protocol

    Supported:

    HTTP

    Cable Length:

    Max. 100 meters

    Connector:

    RJ45 (telephone jack style)

    Data Collection

  • 7/24/2019 DAU Specification (Latest)

    3/5

    Page 3 of 5

    Rotating Speed Inputs:

    Supports max. 8 rotating speed

    signals, 1 rotating speed processing

    cards, 8 A/D cards. The speed range

    support is 12~32000rpm.Input Type: Differential DC Input

    Input Resistance: 400K#

    Input Range: "100V

    Linear Range: "18V

    Filter Performance: Filters AC

    signals whose peak-peak value is

    less than 20% of reference threshold

    Volts.

    Phase Delay:

  • 7/24/2019 DAU Specification (Latest)

    4/5

    Page 4 of 5

    -Frequency band 1 amplitude

    -Frequency band 2 amplitude

    -Residual amplitude

    Automatic statistic learning to get

    thresholds

    Characteristics of Data Storage:

    Time-driven

    Event-driven

    Data Type:

    Real time data

    Trend data

    Previous hour data

    8, previous day data

    9, previous week data

    10, previous month data

    11, previous year data

    13, startup/shutdown data

    14, sensitive monitoring data

    3, 4, 5, black box data

    6, before sensitive monitoring data

    7, load throw-off data

    Data Upload

    Under good network condition;

    - Data upload frequency: up to1s/time

    - With high ratio data compress

    technology, narrow net band

    needed: 2kbps/channel.

    When network interrupted:

    - Data be temporarily saved in

    the memory

    - Memory space can last for 15

    days.

    - Upload be continued

    automatically when network

    recovered

    Environmental Requirement

    Indoor use

    Altitude up to 2000m

    Temperature 5to 40

    Max. relative humidity 80%

    Main supply voltage fluctuations up

    to "10% of the nominal voltage

    Rated pollution degree II

    Degree of protection IP 20

    CE Mark Directives

    EMC Compliance

    Management Group Issued

    Certificate No.:

    EC10147

    EC61326:

    2006, Emissions

    EN55011:

    1998+A1: 1999, Radiated and

    Conducted Emissions

    EN61000-3-2:

    2000, Harmonic Current Emissions

    EN61000-3-3:

    1995+A1:2001,Voltage Fluctuations

    EC61326:

    2006, Immunity

    EN61000-4-2:

    Edition 1.2(2001), Electrostatic

    Discharger Immunity TestEN61000-4-3:

    2002, Radiated, Radio-Frequency,

    Electromagnetic Field Immunity Test

    EN61000-4-4:

    2004, EFT/Burst Immunity

    EN61000-4-5:

    Edition 1.1:2001, Surge Immunity Test

    EN61000-4-6:

    Edition 2.0(2003), Conducted Immunity

    EN61000-4-8:

    Edition 1.1(2001), Power Frequency

    Magnetic Field Immunity Test

    EN61000-4-11:

    2004, Voltage Dips and Short

    Interruptions Immunity Test

    EC61010:

    Safety requirement for electrical

  • 7/24/2019 DAU Specification (Latest)

    5/5

    Page 5 of 5

    equipment for measurement, control,

    and laboratory use

    Physical Parameters

    Dimensions(HeightWidthDepth):

    134mm$452mm$451mm

    Weight:

    17kg

    Rack Installation

    Requirement:

    3U