Specifications
Data Acquisition Unit
Description
The Data Acquisition Unit (DAU) is part of the S8000 Plus System. It
samples the signal inputs such as rotating speed, vibration, process
variables, converts them from analog to digital and transfers the data to
WEB8000 Plus.
It supports the TCP/IP protocol based on the Ethernet (10M/100M)standard, and transmits data via the enterprise network. In addition it is
characterized by high speed, high accuracy, high reliability, easy
installation and connection, maintenance-free.
Meanwhile, the DAU is the first field acquisition station in the world with
a WEB function. From a computer on the same network with the DAU, a
user can view spectrum and other data from the DAU with IE browser.
According to the application and capacity, there are 6 types of DAU. They
are NET8000 Plus, NET8000 Dual, PWR8000 Plus, PWR8000 Dual and
HYD8000 Plus, HYD8000 Dual.
Type of the DAU
Application NET8000 Plus
NET8000 Dual
PWR8000 Plus
PWR8000 Dual
HYD8000 Plus
HYD8000 Dual
Rotating
Speed
>4000 RPM
32000 RPM
>1000RPM
4000RPM
!12RPM
1000RPM
Industry
Petroleum
&chemical,
Steel & Aluminum
Coal Fired Power,
Nuclear PowerHydro Power
Number of Inputs of the DAU
Signal Type NET8000 Plus
PWR8000 Plus
HYD8000 Plus
NET8000 Dual
PWR8000 Dual
HYD8000 Daul
Rotating Speed 4 8
Vibration 24 48
Hard-Wired Process 12 24
Figure: PWR8000 Plus
Figure: PWR8000 Plus Rear View
-
7/24/2019 DAU Specification (Latest)
2/5
Page 2 of 5
Specifications of DAU
Inputs
Power Supply:
AC220V"10% 50Hz
AC110V"10% 50Hz
Power
Consumption:
Max. 80 Watts
Data Port
(Backboard):
Max. 19.2kbps Serial Communication (2
RS232 ports)
10Base-T/100Base-TEthernet (1 RJ45
port)
Outputs
Front Panel LEDs:
PWR LED:
Turn green when the DAU is powered on
OK LED:Turn green when the DAU is operating
properly
LAN LED:
Turn green if the communication with
WEB8000 Plus is fine via Ethernet
COM1 LED:
Turn green if the communication is fine
on COM1 port
COM2 LED:
Turn green if the communication is fine
on COM2 port
K1-K4/K8 LEDs:
Turn green if the corresponding rotating
speed signal is normal.
DYNAMIC
(1-24/48) LEDs:
Turn green if the corresponding vibration signal is
normalSTATIC
(1-12/24) LEDs:
Turn green if the corresponding process
signal is normal
Communications
Protocol:
MODBUS:
Communication with DCS system to
obtain process signals
HTTP:
Communication with WEB8000 Plus
server to transmit data
Backboard
Communications:
RS232
Protocol
Supported:
MODBUSBaud Rate:
Max. 19.2kbps
Cable Length:
Max.15meters
Connector:
DB9 serial cable
Backboard
Communications:
Ethernet, 10Base-T/100Base-TX
Protocol
Supported:
HTTP
Cable Length:
Max. 100 meters
Connector:
RJ45 (telephone jack style)
Data Collection
-
7/24/2019 DAU Specification (Latest)
3/5
Page 3 of 5
Rotating Speed Inputs:
Supports max. 8 rotating speed
signals, 1 rotating speed processing
cards, 8 A/D cards. The speed range
support is 12~32000rpm.Input Type: Differential DC Input
Input Resistance: 400K#
Input Range: "100V
Linear Range: "18V
Filter Performance: Filters AC
signals whose peak-peak value is
less than 20% of reference threshold
Volts.
Phase Delay:
-
7/24/2019 DAU Specification (Latest)
4/5
Page 4 of 5
-Frequency band 1 amplitude
-Frequency band 2 amplitude
-Residual amplitude
Automatic statistic learning to get
thresholds
Characteristics of Data Storage:
Time-driven
Event-driven
Data Type:
Real time data
Trend data
Previous hour data
8, previous day data
9, previous week data
10, previous month data
11, previous year data
13, startup/shutdown data
14, sensitive monitoring data
3, 4, 5, black box data
6, before sensitive monitoring data
7, load throw-off data
Data Upload
Under good network condition;
- Data upload frequency: up to1s/time
- With high ratio data compress
technology, narrow net band
needed: 2kbps/channel.
When network interrupted:
- Data be temporarily saved in
the memory
- Memory space can last for 15
days.
- Upload be continued
automatically when network
recovered
Environmental Requirement
Indoor use
Altitude up to 2000m
Temperature 5to 40
Max. relative humidity 80%
Main supply voltage fluctuations up
to "10% of the nominal voltage
Rated pollution degree II
Degree of protection IP 20
CE Mark Directives
EMC Compliance
Management Group Issued
Certificate No.:
EC10147
EC61326:
2006, Emissions
EN55011:
1998+A1: 1999, Radiated and
Conducted Emissions
EN61000-3-2:
2000, Harmonic Current Emissions
EN61000-3-3:
1995+A1:2001,Voltage Fluctuations
EC61326:
2006, Immunity
EN61000-4-2:
Edition 1.2(2001), Electrostatic
Discharger Immunity TestEN61000-4-3:
2002, Radiated, Radio-Frequency,
Electromagnetic Field Immunity Test
EN61000-4-4:
2004, EFT/Burst Immunity
EN61000-4-5:
Edition 1.1:2001, Surge Immunity Test
EN61000-4-6:
Edition 2.0(2003), Conducted Immunity
EN61000-4-8:
Edition 1.1(2001), Power Frequency
Magnetic Field Immunity Test
EN61000-4-11:
2004, Voltage Dips and Short
Interruptions Immunity Test
EC61010:
Safety requirement for electrical
-
7/24/2019 DAU Specification (Latest)
5/5
Page 5 of 5
equipment for measurement, control,
and laboratory use
Physical Parameters
Dimensions(HeightWidthDepth):
134mm$452mm$451mm
Weight:
17kg
Rack Installation
Requirement:
3U