-------Data Center 2012TIER 4
Data Center
![Page 2: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/2.jpg)
-------
-------Data Center 2012TIER 4
Data Center
A True CloudData Center
The largest, most sophisticated & Most
advanced in Israel
![Page 3: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/3.jpg)
-------
-------Data Center 2012TIER 4
Data Center
The largest in terms ofEnergy.
The most sophisticated in terms of .Technology
The most advanced in terms of Cloud Computing.
![Page 4: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/4.jpg)
-------
-------Data Center 2012TIER 4
Electricity – Maximum power output 5MW
Two high voltage feeds: 2x22KV
Two transformation stations: 2x2.5MW
Redundant electrical panels for redundant feeds
2X(N+1) UPS systems
2N generator systems
Data Center
![Page 5: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/5.jpg)
-------
-------Data Center 2012TIER 4
Air-conditioning – 800 tons of refrigerant
Equivalent to cooling a Triple C building 55 stories high
N+1 redundant chiller configuration
Redundant cold water supply system
N+1 redundant rack cooling
N+1 redundant perimeter floor air-conditioning
Data Center
![Page 6: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/6.jpg)
-------
-------Data Center 2012TIER 4
Green Computing – Energy saving
Server consolidation and high density hosting
Economical and green computing equipment
Water cooled to a temperature of 15°C
Water cooling towers for efficiency and energy savings
In-Row Rack cooling
for maximum efficiency and green cooling
Data Center
![Page 7: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/7.jpg)
-------
-------Data Center 2012TIER 4
Production floor – 12KW or 64A per rack
Approx. 500 racks spread over three levels
An underground level with 150 racks
Two above ground levels with 340 racks
Racks connected to redundant power feeds
Control and management rooms on the ground floor
Work rooms for customers
Data Center
![Page 8: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/8.jpg)
-------
-------Data Center 2012TIER 4
UPS – Redundant systems for redundant feeds
Two clusters of UPS systems for redundancy
Four rows of batteries per system for redundancy
Every UPS cluster in an N+1 configuration
for redundancy
Data Center
![Page 9: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/9.jpg)
-------
-------Data Center 2012TIER 4
Generator – Redundant systems for redundant feeds
Maximum power output: 2x2.5MW
Two clusters of generator systems for redundancy
Each generator cluster in an N+1 configuration
for redundancy
Data Center
![Page 10: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/10.jpg)
-------
-------Data Center 2012TIER 4
TIER IV
Data Center
Level
TIERRedundancy level
Reliability level
Downtime
Cost to KW)USA prices(
Underground level
TIER IV
X(N+1)2
99.995%
0.4
$22,000
Upper Level
TIER II
N+1
99.749%
22
$11,000
![Page 11: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/11.jpg)
-------
-------Data Center 2012TIER 4
![Page 12: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/12.jpg)
-------
-------Data Center 2012TIER 4
Networking - WAN
Network Level Protection
Dynamic packet filtering
Application level attack
Security zones
Data Center
![Page 13: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/13.jpg)
-------
-------Data Center 2012TIER 4
Networking – 10 GB LAN
Layer 2 and layer 3 switching capabilities
Virtual Chassis technology
10/100/1000BASE-T ports
Simplified Management and Operations,
Port security features including, snooping
DAI and MAC limiting
Data Center
![Page 14: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/14.jpg)
-------
-------Data Center 2012TIER 4
![Page 15: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/15.jpg)
-------
-------Data Center 2012TIER 4
Information security
SSL VPN
Network level protection
Dynamic packet filtering
Application level attack
Security zones
IPS
Data Center
![Page 16: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/16.jpg)
-------
-------Data Center 2012TIER 4
Building management & Control system
Building control system
Entry control system
CCTV system
24x7 control, management and monitoring room
Data Center
![Page 17: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/17.jpg)
-------
-------Data Center 2012TIER 4
Monitoring & Control of computing
Computing control system
LAN and WAN communications control system
Rack surveillance and locking system
Rack temperature and humidity control system
24X7 Help Desk for service and support
Data Center
![Page 18: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/18.jpg)
-------
-------Data Center 2012TIER 4
Services
Cloud computing services
Colocation & Hosting services
Disaster Recovery (DR) services
Data Center
![Page 19: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/19.jpg)
-------
-------Data Center 2012TIER 4
Cloud computing services
Immediate availability No need to invest in infrastructure purchases Hardware and software No administration and maintenance costs Payment for use of services only! The ability to regulate the computing power
Data Center
Disk Cloud SaaS PaaS IaaS
![Page 20: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/20.jpg)
-------
-------Data Center 2012TIER 4
Services
Cloud services
Colocation & Hosting services
Disaster Recovery (DR) services
Data Center
![Page 21: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/21.jpg)
-------
-------Data Center 2012TIER 4
Placing a replication of an alternative site at your disposal
Definition of the SLA: RPO (Recovery Point Objective): the maximum loss of data acceptable to an organization in the event of a disaster RTO (Recovery Time Objective): the maximum length of time that the computing systems can be out of actionThe work environment in a DR emergency
Data CenterDisaster Recovery service
![Page 22: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/22.jpg)
-------
-------Data Center 2012TIER 4
Advanced added value services
Advanced data security
Data storage
Backup and restore
Monitoring and reporting services
IT Managed Services
Data Center
![Page 23: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/23.jpg)
-------
-------Data Center 2012TIER 4
24/7 Support
24/7 Help Desk
On-site hardware maintenance
On-site software support
IT managed services
Basic remote operations
Data Center
![Page 24: Data center 2012 en](https://reader034.vdocuments.us/reader034/viewer/2022051609/54806076b4af9fbe158b5e4a/html5/thumbnails/24.jpg)
-------
-------Data Center 2012TIER 4
Security
Advanced measures
Round-the-clock access control
Biometric login
Monitoring and documentation by cameras
Site staffed round-the-clock
Data Center