customer product release summary lfm server 4.4.0 · pdf fileplant review and navisworks is...

18
www.lfm-software.com Customer Product Release Summary LFM Server 4.4.0.23 Release Date: 26/05/2017 This document outlines all changes made in the above release of LFM software. Document Prepared by: Praveen Vankdoth Application Consultant Document Approved by: Jennifer Copple Senior Application Consultant Superseded software version: LFM Server 4.4.0.18 LFM Software version numbers: X.X.X.X First version field denotes general software series number. Second version field is incremented to track major new feature implementation. Third version field is incremented to track minor new feature implementation. Final (fourth) version field is incremented to track error fixes. PC minimum supported specification: Processor Intel Core 2 Duo Memory (4x1024) 667Mhz DDR2 Dual Channel ECC Hard Drive 80GB (7200RPM) Serial ATA11 Graphics card NVIDIA Quadro FX 2000 Operating system Windows 7 x64 Network 1GB Ethernet card

Upload: lamhuong

Post on 10-Mar-2018

290 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Customer Product Release Summary

LFM Server 4.4.0.23 Release Date: 26/05/2017

This document outlines all changes made in the above release of LFM software.

Document Prepared by: Praveen Vankdoth – Application Consultant

Document Approved by: Jennifer Copple – Senior Application Consultant

Superseded software version: LFM Server 4.4.0.18

LFM Software version numbers: X.X.X.X

First version field denotes general software series number.

Second version field is incremented to track major new feature implementation.

Third version field is incremented to track minor new feature implementation.

Final (fourth) version field is incremented to track error fixes.

PC minimum supported specification:

Processor Intel Core 2 Duo

Memory (4x1024) 667Mhz DDR2 Dual Channel ECC

Hard Drive 80GB (7200RPM) Serial ATA11

Graphics card NVIDIA Quadro FX 2000

Operating system Windows 7 x64

Network 1GB Ethernet card

Page 2: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Enhancements for this release:

Introducing the HyperBubble The HyperBubble is an advanced-rendering technique created to provide an immersive visualisation of point cloud data. The new HyperBubble flight mode allows you to step outside of the traditional BubbleView and move freely around a project with the ability to ‘park’ to a scan location where demolished data is hidden from the user. The HyperBubble is a standard, built-in feature of LFM Server 4.4 meaning no additional licensing is required for the feature and that you can use it simultaneously with the BubbleView and point cloud viewing modes.

Further information on HyperBubble, including pre-requisites, how to produce HyperBubble and how to use HyperBubble, can be found in the LFM Server help guide (see page 1 – “Additional Resources” (link to “HyperBubble Creation and Use”)).

Page 3: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Project Zoning One of LFMs strengths has always been the ability to manage an unlimited number of scans in a single project. Our unique, ‘InfiniteCore’ approach to managing and navigating laser datasets has allowed our customers to work seamlessly with enormous assets. The introduction of zoning functionality takes this process to the next level by allowing users to identify specific areas of interest as part of the project hierarchy. These zones of interest can be created and saved very simply using volume functionality offering the user tailorable point density and therefore much easier navigation around a project. The ability to create sub divisions of areas will allow companies to splice projects in keeping with their project teams, vastly simplifying the process of consuming the laser data alongside their CAD application. Unified Processes LFM have made general improvements to unify the measurement, volume, markup and object processes across the various viewing modes. This means users can now carry out measurements (point, distance, chained and pipe diameter), volume selection, markup creation and object modifications (pipe extension and tie-in creation) across all views (point cloud, BubbleView and HyperBubble). Streamlined Interface As a result of the unified processes the LFM interface has been streamlined to group logical features together. This also includes the new View toolbar which contains all the functions related to the control of the 3D window such as toggling points, scan sites, colour .lfds and Edge Mode. More OPEN than ever… Those familiar with LFM know that we strive to provide a neutrality to our solutions to enable our customers to benefit from having the freedom to choose the right solution for them, whether that be with capture device or CAD package, without impacting internal work processes. LFM Server allows data from any capture device to be put into a single dataset ready for consumption and this latest release will now facilitates:

- LAS compatibility (.las)

- Leica P20 (.prj) data, both intensity and colour

- Riegl project format (.rsp)

- Improved conversion of Dot Product data

- Handling unstructured E57 data

Page 4: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

In addition to working with a broader spectrum of data LFM Server also has improved connectivity with Intergraph products. We are now able to deliver the BubbleViews directly into Smart3D, showing objects in BubbleViews and importing tie-ins. Smart Plant Review and Navisworks is now also able to integrate the HyperBubble. New for LFM Server 4.4.0.18!

LFM Server 4.4.0.18 introduces support for Navisworks 2017 and Revit 2017.

Page 5: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Known Issues:

Internal Reference

Description

LFM-942 FARO SDK is not getting installed though the relevant option selected on the installer while installation process. This means this version of LFM Server cannot be used to convert FARO scans on machines that have not had a previous version of LFM Server installed. Follow the below workaround if you want to use this version of LFM Server to convert fls scans. Alternatively please upgrade to the LFM Server 4.4.1 series where this issue is fixed.

1. Install the latest FARO SDK from the FARO website - http://www.faro.com/products/faro-software/scene/downloads

2. Run a command window that is opened via "run as Administrator"

3. Navigate into the folder with the FARO SDK. Navigate to the latest 64bit installation of the FARO SDK, e.g. C:\Windows\winsxs\amd64_faro.ls_1d23f5635ba800ab_1.1.503.3_none_34818da5032c9ddb

4. Then enter the command “regsvr32 iQOpen.dll” and press return. You

should now get the message “DllRegisterServer in iqopen.dll succeeded” and the scan import should now be successful.

B5195 LFM Server: Gateway Mode expects and supports the following variant of .ptx file:

LFM are aware of some instances of .ptx files that do not match the format above. LFM will look to incorporate support for these variants as and when they become known. However, any variations on this format are susceptible to problems (including crashes or failure to convert). This includes failure to convert with the error "Failed to create a .zfc file, Intensity and Image files PATH.int ! Disk Full?"

Page 6: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

B5504 The option to import .las format files has been removed from LFM Server 4.4.0.18 and 4.4.0.23 due to measurement/display inaccuracies with large .las format files. We have resolved these issues in the LFM Server 4.4.1 series. If you wish to use .las data, please upgrade to the LFM Server 4.4.1 series.

B3692 Importing an .lfm project file into another .lfm project file gives the wrong target positions resulting in red traffic lights for all targets. To get around this please update the scan headers in the source projects and add the updated .zfcs to a new project. This will result in one project containing all scans that are registered correctly.

Page 7: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

General/Server Mode error fixes for this release: 4.4.0.23

Internal Reference

Description Solution

B5508 SmartPlant Review (SPR) CAD link hangs on connection.

The issue is fixed. SPR link is now working fine when connecting to LFM Server 4.4.0.23.

B5531 Adjusting an existing volume creates a new volume rather than reflecting the change in the adjusted volume.

The issue is fixed, volume adjustment is now working as expected.

B4804 Application hangs while running volume based clash check in AutoCAD CAD link.

The issue is fixed and now volume based clash check is working fine in AutoCAD CAD link.

B5483 “Mask demolished areas” checkbox is not enabled on Publish LFM NetView Project window.

The issue is fixed and now “Mask demolished areas” checkbox is enabled on Publish LFM NetView Project window.

B5398 3D Markups disappear while setting Display Objects (.RVM Objects) to “All” and 3D Markups appear on setting the display Objects to “None”.

The issue is fixed and now Display Objects to All/None is not have any effect on 3D Markups and working as expected.

B5303 CAD Objects not displayed in 3D View when clash check is run through AutoCAD.

The issue is fixed and now CAD objects are displayed in 3D View when clash check is run through AutoCAD.

B5457 Point cloud data and HyperBubble views are merged while accessing “Toggle Low Density Points”, “Toggle Points”, “Toggle Edge Mode”, “Toggle HyperBubble” and “Optimise Contrast” from Point Controls toolbar in the Navisworks CAD link.

The issue is fixed. Now point cloud data and HyperBubble views will not merge while accessing the Point Controls toolbar in the Navisworks CAD link.

B3431 AutoCAD CAD link produces clash report for all objects rather than for objects in selected volumes.

The issue is fixed. Now user can produce clash report for objects in selected volumes.

B3462 Failure to export box and cylinder Markup in .csv file format.

The issue is fixed. Now user can export box and cylinder Markup in .csv file format successfully.

B5247 Ability to Toggle low density points when HyperBubble is active in AutoCAD.

The issue is fixed. Now user can toggle Low Density points on/off while HyperBubble is active in AutoCAD.

Page 8: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

B5514 “Unable to open the Attribute Data File – FNF: File not found %AVEVA_DESIGN_EXE%/attlib.bat” error always appears upon launching "AVEVA PDMS 12.1.SP5 CAD link"

The issue is fixed and now user can launch AVEVA PDMS 12.1.SP5 CAD link successfully.

B4409 Clicking on “Show BubbleView at point” button on LFM Server control toolbar and picking point in 3D View Fails to return BubbleView or returning the wrong one.

The issue is fixed and now LFM server returns correct BubbleView while clicking on “Show BubbleView at point” button and on LFM Server control toolbar and picking point in 3D View.

LFM-911 Running entire/volume based clash check sometimes fails to return the clash list in MicroStation CAD Link.

The issue is fixed and now both clash checks (entire/volume based) are working fine in MicroStation CAD link.

LFM-905 Running volume based clash check in AutoCAD CAD link takes much time to generated the clash list.

The issue is fixed and now volume based clash list generation process takes normal time in AutoCAD CAD link.

LFM-327 Application crashes when adjusting Zones.

The issue is fixed and now the user can adjust Zones normally.

LFM-451 Projects opened in LFM Server 4.4.1.0 onwards display an “Unknown Entity” when opened in LFM Server 4.4.0.18 or earlier

LFM Server 4.4.0.23 now hides these entities if a project has been opened in LFM Server 4.4.1.0 or later.

Gateway Mode error fixes for this release: 4.4.0.23

Internal Reference

Description Solution

B2515 Volume selection does not work with pts data - no points are shows.

The issue is fixed. Volume selection is now working fine with pts data and now points are displayed.

B4290 Super-high colour mapping fails if location for converted scan files and imported scans directories are same.

The issue is fixed. Now LFM Server won’t allow the user to place converted scan files in imported scans directory.

B5556 Should be able to manipulate scan if Group North or East [or up] is set.

The issue is fixed. Now able to do manipulation when Control points are set to North or East or Up.

B3287 Unable to create volume in 3D View using “Get Volume at Point” button from Volumes tab (Cursor remains struck showing as “Select Point in BubbleView” and volume Selection dialogue will not open).

The issue is fixed and now user can create Volume using 'Get volume at point' button from Volumes tab in 3D View.

Page 9: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

General/Server Mode error fixes for previous release: 4.4.0.18

Internal Reference

Description Solution

B2379 Volumes exported as .lfx or .lfv do not import in the correct position when imported into a different project.

Volumes exported as .lfx now import in the correct position when imported into a different project. The .lfv format for volumes export is no longer required and has been removed.

B4737 The LFM NetView project publishing process does not copy the Config directory into the LFM NetView dataset directory.

The issue is fixed and now the Config folder is copied under the LFM NetView dataset directory during publishing.

B5215 Running the AutoCAD link via a network also takes a Revit link licence.

The Revit licence request has been removed and now running the AutoCAD link via a network will not consume Revit licence.

B5268 Only five images for each floorplan are created during LFM NetView project publishing.

All floorplan images are now being generated as they should during the LFM NetView publish.

B5294 Plant3D 2017 crashes after using the Show Objects function.

The issue is fixed and objects are now successfully passed from Plant3D 2017 to LFM Server without crashing.

B5275 PDMS is slow to respond on mouse clicks when connected to LFM Server.

The issue is fixed and the PDMS is now able respond properly on mouse clicks when connected to LFM Server.

B5248 Reset volume in AutoCAD doesn't restore the low-resolution points when HyperBubble is active.

The issue is fixed and clicking the Reset Volume command in LFM Server/AutoCAD will restore the low-resolution points.

B5277 LFM Server toolbar does not appear in Navisworks 2015/2016 CAD link.

The user is now able to see the LFM Server toolbar with point cloud data loaded. Hence, the issue is fixed.

B5408 During LFM NetView project publishing, floorplans not being created with sufficient depth.

The issue was with the floorplan zoom level value at the source which was adjusted and now the user is able to zoom in properly.

B4405 Ability to double click on a Markup to open the best BubbleView in LFM NetView for markups imported into LFM Server via a .csv file.

The user is now able to double click on a Markup in LFM NetView and the best BubbleView will automatically be opened.

Page 10: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

B4562 LFM Server fails to publish colour BubbleViews for LFM NetView projects if the .lfp files are not present and the colour .jpgs are not in the same folder as the .zfc files at the time of project publishing.

LFM Server now checks whether the LFM Server BubbleViews are colour or not at the start of the publishing process. If they are and the colour .jpgs are not in the same folder as the .zfc files, LFM Server asks the user to locate the colour .jpgs so the LFM NetView BubbleViews are created in colour.

B690 AutoCAD crashed when unloading the .arx file.

The issue is fixed and the user is now able to unload .arx and .dbx files successfully from AutoCAD.

B5338 Unable to load unsigned datasets. The user is now able to load unsigned datasets. Note that if a dataset is unsigned it cannot be loaded alongside another dataset. This is the intended behavior for unsigned datasets.

B5321 Setting the Mouse Mode option to Wheel does not lock out roll rotation as intended.

Setting the Mouse Mode option to Wheel now locks roll rotation as intended.

B5342 Zoom Extents function in AutoCAD link zooms to an area that encompasses the extents of the point cloud and 0,0,0. This can make the view zoom out too far, particularly for datasets at large coordinates.

Zoom Extents function in AutoCAD link now zooms only to the extents of the dataset. It does not incorporate 0,0,0 in the extents.

B5136 CAD objects in BubbleView cannot be toggled off.

The issue is fixed and the user is now able to toggle on/off the objects sent from CAD to LFM Server.

B5329 Toggle HyperBubble is not working in Navisworks.

The issue is fixed and the user is now able to toggle the HyperBubble in Navisworks.

B5289 Unable to toggle objects using F4 hotkey.

The issue is fixed and the user is now able to toggle on/off the CAD objects with F4 hotkey.

B5091 Selecting a volume in AutoCAD, adjusting the volume in LFM Server and adding the adjusted volume to the Volumes Manager automatically added the volume under a category.

The selected volume in AutoCAD is now being added as a single volume (without a category) after its adjustment in LFM Server.

B5322 Zoom to Extents with a volume selected in SmartPlant 3D zooms to the extents of the project, not the extents of the volume.

Zoom to Extents with a volume selected in SmartPlant 3D now zooms correctly to the extents of the volume.

Page 11: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

B5140 No ability to link multiple session of LFM Server simultaneously with SmartPlant 3D for database detect clashing purposes.

The user is now able to open multiple instances of SmartPlant 3D/LFM Server and able to load a different dataset into each. Please see Appendix 1 at the end of this document for further information.

B4878 Support Database Detect for clashing in SmartPlant 3D.

Database Detect clashing is now possible in SmartPlant 3D. Please see Appendix 2 at the end of this document for further information.

B5274 Fitting a pipe via the LFM Server toolbar in AutoCAD can sometimes be inaccurate.

The pipe fitting function now asks the user to pick on both the start and end point of the pipe (as opposed to clicking just one point on the pipe as in previous versions) which indicates the length of the pipe to LFM Server, making the fitting algorithm more accurate.

Gateway Mode error fixes for previous release: 4.4.0.18

Internal Reference

Description Solution

B5273 Volume selection in BubbleView crashes the LFM Server (Gateway Mode only).

The user is now able to create volumes in BubbleView while in LFM Server: Gateway mode.

B2866 Targets picked on the seam of the scan are visually not in the correct position in the BubbleView.

The visual position of targets picked on the seam of the scan is now correct in both the 3D view and the BubbleView.

B5238 FARO SDK is not up to date meaning some (new) FARO scans cannot be successfully converted in LFM Server.

The FARO SDK has been updated. All FARO scans should now convert successfully.

Page 12: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Product QA cycle: The LFM Software development philosophy uses AGILE principles to ensure a high quality product which evolves to match customer requirements. Throughout the development cycle, test and evaluation is used to guide the process and minimise the final test overhead. The final test process has three stages, and this document has been prepared after these have been completed. These stages are outlined below.

Individual Function Test All LFM desktop functionality is examined for correct responses. Functions called from the Main Menubar, Main Toolbar, Modelling Toolbars, and Component Browser are tested in turn. This ensures that the functionality matches the design intent, and previously recorded errors have been fixed.

Destructive Test This section of the test schedule is aimed at investigating to see if a software product exhibits proper behaviour when subjected to improper usage, or improper input. The tests are applied to different data samples, machines, and in a random manner to try to replicate 'real world' variations in user conditions.

Software Acceptance Tests LFM Software concludes the LFM test cycle with a series of controlled examples

aimed at simulating real life use situations. The finished models are QA checked against calibrated historical data, to ensure that the product maintains the previous output standard.

Page 13: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Appendix 1: Machine Setup to allow multiple sessions of

Smart 3D and LFM to run on the same machine

Requirement:

Win7 SP1 or greater

LFM Server 4.3.0.30 / 4.4.0.18 or greater IMPORTANT: Once LFM Server/Smart 3D (S3D) has been setup to allow multiple connections on the same machine you will no longer be able to manually open LFM and get S3D to connect to that instance of LFM Server. S3D will always open a new session of LFM Server automatically. Steps: To enable multiple connections between LFM Server and S3D:

1. Open the registry (regedit.exe) 2. Navigate to "HKey_Local_Machine\Software\Wow6432Node\LFM

Software\lfmServerAPI.dll\[version]\s3dhost.exe 3. Select the Key CadlinkMultiConnection 4. Set value to "1"

To disable this setting:

1. Repeat steps 1-3 as above 2. Set value to "0"

Page 14: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Appendix 2: Settings for Database Clash Detection in S3D

CAD link

SmartPlant 3D (S3D) is able to run a database clash detection service on any S3D project to allow the user to identify issues in there model. This steps below will detail the steps that are required in order to run the SmartPlant database clash detection with an LFM Server point cloud. It will be assumed you are already familiar with setting up a standard S3D clash detection server and that you already have some projects setup with LFM Server point clouds attached.

1. Stop the IFC service

Note: The S3D Database clash detection is unable to clash point cloud data when it is being run as a standard service. To allow it to clash point cloud data it needs to be run as a process instead:

Navigate to “Control Panel > All control Panel Items > Administrative Tools >

Services”

Turn off “SmartPlant 3D Interference Detection Service”

2. Create IFC process batchfile

Navigate to “C:\Program Files (x86)\Smart3D\FoulCheck\Middle\bin”

Create a batch file called “IFCStart.bat” with the following contents:

IfcNtSvc.exe /Auto /0

pause

Page 15: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

3. Run the IFC process batchfile

Run “IFCStart.bat” as Administrator (this can be setup as a scheduled task if

required)

If you open the task manager you should see 1 instance of the “IfcNtSvc.exe

*32” running which indicates that the S3D clash detection is ready

4. Configure the Database Clash Settings

Open S3D Project Management

Select “[project] > Interference Server > properties”

Setup the “Interference Server Settings” as you wish but ensure that the “SP3D

– PointCloud” box is checked

Page 16: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Click “Start”

After a few moments an “IfcProcess.exe” with start running, then LFM Server

will start

5. Allow multiple clash detections on 1 Server (optional)

Page 17: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

Requirements: LFM Server 4.3.0.31/4.4.0.15 or greater

Note: This last step is only valid if you want to use one server to run the clash detection for multiple S3D projects with LFM Server point cloud data

Open Regedit.exe

Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\LFM

Software\lfmserverAPI.dll\4.4.0.0\IfcProcess.exe

Change the “CadlinkMultiConnection” key to “1”

Page 18: Customer Product Release Summary LFM Server 4.4.0 · PDF filePlant Review and Navisworks is now also able to integrate the HyperBubble. ... series. If you wish to use ... launch AVEVA

www.lfm-software.com

This will instruct LFM Server to allow multiple S3D-LFM pairs so that the several clash detections can be run in parallel. Note: Although there should be no limitation on how many instances of LFM Server can be run on one machine, be aware that the database clash detection can take a lot of resources so choose a server appropriate for the amount of projects you wish to run at once.