creating life long relationships

32
Creating life long relationships. Our Network Components keep your cable systems intact.

Upload: others

Post on 29-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Creating life long relationships

Creating life long relationships. Our Network Components keep your cable systems intact.

Page 2: Creating life long relationships

2 www.prysmiancable.com.au | www.prysmiancable.co.nz

Medium Voltage Accessories to link electrical infrastructuresAccessories play a vital role in a power system. Prysmian has gained expertise in the design, manufacture and testing of products across all voltages during many years of partnership with customers.

We can offer you a comprehensive range of accessories for glanding, jointing, connecting and terminating MV systems. The range includes joints (also transition, trifurcating and branch joints), terminations (both for indoor and outdoor use) and separable connectors.

In addition we can provide you with engineering services capable of fulfilling any power system specifications or requirements and of delivering customised solutions.

Our Network Components keep your cable systems intact.To link the cable systems and provide communities with a continuous flow of power, you not only need reliable cables, you need dependable components to keep it all together, too. Built on decades of experience we develop state-of-the-art joints, terminations and connectors that’ll give your MV network long-lived stability – and you peace of mind.

All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group.

Table of ContentsMedium Voltage Accessories to link electrical infrastructures 2

Network Components Locations 4

Evolution of the Technology & Design 5

CABLE JOINTS 7

ECOSPEED™ – COLD SHRINK JOINT 8

TERMINATIONS 11

TERMFIT™ – COLD SHRINK TERMINATION 12

CONNECTORS 15

STRAIGHT CONNECTOR – MSCS/EC-250-A 16

STRAIGHT CONNECTOR – MSCS/EC-400-B 18

STRAIGHT CONNECTOR – FMCS-400 20

ELBOW CONNECTOR – MSCE/EC-250-A 22

ELBOW CONNECTOR – FMCE-400 24

TEE CONNECTOR – MSCT/EC-630-C 26

ACCESSORIES FOR SERIES 400 28

INTERFACES 30

Page 3: Creating life long relationships

3www.prysmiancable.com.au | www.prysmiancable.co.nz

Prysmian Group is world leader in the energy and telecom cable systems industry. With almost 140 years of experience, sales exceeding €11 billion (pro-forma as of 31.12.2017), about 30,000 employees in over 50 countries and 112 plants, the Group is strongly positioned in high-tech markets and offers the widest possible range of products, services, technologies and know-how.

The Prysmian Group corporate brand operates in the market through three distinct commercial brands – Prysmian, Draka and General Cable. These are three of the global cable industry’s strongest brands, characterised by highly complementary products and services. We use our three commercial brands when talking about products and solutions, and each represents a specific part of the overall offering that Prysmian Group presents to its customers.

Page 4: Creating life long relationships

4 www.prysmiancable.com.au | www.prysmiancable.co.nz

SUZHOU / YIXING

Network Components LocationsSeven plants in Europe and two state-of-art plants in China.

MILAN – ITALY Headquarter and R&D Laboratories

QUATTORDIO – ITALY MV solutions & Compounds

LIVORNO – ITALY EPR, Click-Fit & Speed range

WREXHAM – UK Components

BISHOPSTOKE – UK HV & Subsea

SENS – FRANCE MV joints and terminations

CORNIMONT – FRANCE MV terminations

DELFT – THE NETHERLANDS HV Click-fit

SUZHOU – CHINA HV solutions

YIXING – CHINA MV solution

MV JointsProduction of the Compound and of the main body in Quattordio (IT).

Expansion, kitting & distribution in the APAC region in Yixing (CN).

MV TerminationsEngineering in Milan and France.

Production and Kitting in Yixing (CN).

QUATTORDIO

MILAN

DELFT

CORNIMONT

SENS

BISHOPSTOKE

WREXHAM

LIVORNO

Page 5: Creating life long relationships

5www.prysmiancable.com.au | www.prysmiancable.co.nz

Cold Shrink Technology Heat Shrink Technology

All components rebuilding the cable layers are assembled in the factory on the same carrier.

Different sleeves and tapes rebuilding the cable layers are supplied in a kit.

It is 100 % electrically tested in the factory like cables. These individual components cannot be pre-tested in factory.

Reduced parking length, it can be used in congested and tight trenches.

Long parking length needed in the trench to pre-position the different components on the cable.

Compact design embedded on a single carrier which can reduce installation errors and external contamination.

Requires multiple sleeves which can increase the risk of external contamination during installation.

Torch and hot work permit not required. No Fire Hazard. Overall safe installation process

Requires torch and hot work permit which can lead to fire hazard and HSE Risk

Ease & Reliability of installation. Integrity of the Joint installation will be uniform thanks to the elastic properties of material used.

Integrity of the Joint installation highly dependant on the Skill level of Jointer

Elastic material creates a dynamic seal, exerts a permanent pressure on the cable which ensures the accessory performances during service.

Non elastic layers can create static interfaces with the cable layers. Successive mechanical stresses (thermomechanical forces, manhole maintenance…) can lead to Leakage and watertightness issues; Voids development.

Evolution of the Technology & Design

• 1945

ACCESSORIES FOR PILC CABLE

Pre-impregnated paper tapes encapsulated in lead sleeves plumbed on site.

• 1975

HEAT SHRINK TECHNOLOGY

Use of prefabricated components based on thermoplastic polyole-fin materials heated up again on the field.

• Beg. 1980s

PREMOULDED ACCESSORIES

Use of pre-fabricated components based on EPR rubber.

• Beg. 1970s

TAPE INJECTED/CASTED ACCESSORIES

• Self-amalgamating tapes started to replace pre-impregnated paper tapes.

• Cast cold-curing resins rebuilt part of the insulation and the outer protection of the joint.

• 1994

COLD SHRINK TECHNOLOGY

• Use of prefabricated components, extrudes or moulded Ethylene Propylene Diene Monomer rubber (EPDM) or silicone rubber (SIR) components with elastic properties.

• They are radially expanded on a carrier.

Up to 60 % installation time savings can be achieved using Cold Shrink in comparison with other technologies.

Save up to

60 % installation

time.

Page 6: Creating life long relationships
Page 7: Creating life long relationships

7www.prysmiancable.com.au | www.prysmiancable.co.nz

CABLE JOINTS

Page 8: Creating life long relationships

ECOSPEED™ – COLD SHRINK JOINT

8 www.prysmiancable.com.au | www.prysmiancable.co.nz

Description

ECOSPEED™ cold shrink joint for Um up to 36 kV polymeric cables. For armoured cable, please contact us for further information.

Utilisation

• Jointing polymeric insulated cables of different specifications.

• Conductor sizes equal or unequal.

• May be directly buried.

• Jointing cables laid underground, in tunnels on horizontal, racks, or aerial.

• Transition joint between extruded and paper insulated cables.

Cables

• Single core polymeric insulation.

• Insulation voltage up to 36 kV (Um).

• Copper or aluminum conductor.

• Conductor sizes: 35 to 400 mm2.

• Tape, wire or polylam metallic screen.

• Non-armoured or AirbagTM armoured.

• Semi-conducting screen extruded.

Standards

Generally meets the requirements of IEC60502-4, ENEL, CENELEC HD 629-1-2, AS/NZS 4805.1, AS/NZS 4325.1.

Quality assurance

The company has been assessed by third party and found in conformity with the requirements of the standard ISO 9001 – EN 29001.

Installation features

• 100 % electrically tested in the factory.

• No special skills or long experience required.

• Easy assembling.

• No need for special tools or heating.

• Wide cables size range taking.

• Immediate energizing after completion of the joint.

• Great flexibility.

• Suitable and qualified for compact insulated cables.

– COLD SHRINK JOINT

CABLE JOINTS

SEPARABLE ELBOW CONNECTOR ASCA for polymeric cables – Deadbreak operation – Rating 250A

ECOPSEED COLD SHRINK JOINT for Um up to 24kV polymeric cables

PEOT/IJ-1-07/18 Technical information subject

to change without notice

APPLICATION Utilisation

Jointing polymeric insulated cables of different specifications

Conductor sizes equal or unequal May be directly buried Jointing cables laid underground, in tunnels on

horizontal, racks, or aerial Transition joint between extruded and paper insulated

cables

Cables

Single core polymeric insulation Insulation voltage up to 24 kV (Um) Copper or aluminum conductor Conductor sizes: 50 to 630 mm2 Tape, wire or polylam metallic screen Non-armoured or AirbagTM armoured Semi-conducting screen extruded

STANDARDS Generally meets the requirements of IEC 60502-4;

ENEL; CENELEC HD 629-1-2. AS4805.1

QUALITY ASSURANCE The Company has been assessed by third party and found in conformity with the requirements of the standard ISO 9001 - EN 29001.

INSTALLATION FEATURES 100% electrically tested in the factory No special skills or long experience required Easy assembling No need for special tools or heating Wide cables size range taking Immediate energizing after completion of the joint Great flexibility Suitable and qualified for compact insulated cables Technical information subject to change without

notice

REFERENCE: PEOTJ-24 / PEOIJ-24

SELECTION TABLE Cross Section

mm2

With Sealing Tape With Resin Filled

Singe Core Three Cores Singe Core Three Cores

35-150 PEOTJ-1C-24-A PEOTJ-3C-24-A PEOIJ-1C-24-A PEOIJ-3C-24-A

185-500 PEOTJ-1C-24-B PEOTJ-3C-24-B PEOIJ-1C-24-B PEOIJ-3C-24-B

630 PEOTJ-1C-24-C PEOTJ-3C-24-C PEOIJ-1C-24-C PEOIJ-3C-24-C

For armoured cable, please contact our sales for further information.

Plastic net tape and resin

Armoured transparent adhesive PVC tape

Adhesive PVC tapeCopper mesh

Ecospeed joint sleeve High permittivity tape Resin injection valve

Mechanical connector

Page 9: Creating life long relationships

9www.prysmiancable.com.au | www.prysmiancable.co.nz

CABLE JOINTS

SELECTION GUIDE – ECOSPEED™

PEOTJ – sealing tape PEOIJ – resin filled

12 kVProduct code

12 kVProduct code

Single core Three core Single core Three core

95-150 PEOTJ-1C-12-A-T3 PEOTJ-3C-12-A-T3 95-150 PEOIJ-1C-12-A-T3 PEOIJ-3C-12-A-T3

185-240 PEOTJ-1C-12-B-T3 PEOTJ-3C-12-B-T3 185-240 PEOIJ-1C-12-B-T3 PEOIJ-3C-12-B-T3

300-400 PEOTJ-1C-12-C-T3 PEOTJ-3C-12-C-T3 300-400 PEOIJ-1C-12-C-T3 PEOIJ-3C-12-C-T3

24 kV Single core Three core 24 kV Single core Three core

35-70 PEOTJ-1C-24-A-T3 PEOTJ-3C-24-A-T3 35-70 PEOIJ-1C-24-A-T3 PEOIJ-3C-24-A-T3

95-240 PEOTJ-1C-24-B-T3 PEOTJ-3C-24-B-T3 95-240 PEOIJ-1C-24-B-T3 PEOIJ-3C-24-B-T3

300-400 PEOTJ-1C-24-C-T3 PEOTJ-3C-24-C-T3 300-400 PEOIJ-1C-24-C-T3 PEOIJ-3C-24-C-T3

36 kV Single core Three core 36 kV Single core Three core

95-300 PEOTJ-1C-36-C-T3 PEOTJ-3C-36-C-T3 95-300 PEOIJ-1C-36-C-T3 PEOIJ-3C-36-C-T3

Page 10: Creating life long relationships
Page 11: Creating life long relationships

11www.prysmiancable.com.au | www.prysmiancable.co.nz

TERMINATIONS

Page 12: Creating life long relationships

TERMFIT™ – COLD SHRINK TERMINATION

Description

Indoor/outdoor cold shrink termination for polymeric cables up to 36 kV.

Utilisation

• For connection of polymeric MV cables to overhead link, air insulated switchgear and transformers, etc.

Cables

• Single core or three core polymeric insulation (PE, XLPE, EPR).

• Copper or aluminium conductors, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of tape, wire or polylam type.

• Insulation voltage up to 36 kV.

• Conductor sizes: 35 to 630 mm2.

• With armour layer or without armour layer.

Standards

Generally meets the requirements of IEC60502-4, GB/T12076.4, AS/NZS 4805.1, AS/NZS 4325.1

Quality assurance

The company has been assessed by third party and found in conformity with the requirements of the standard ISO 9001 – EN 29001.

Installation features

• No need for special tools, no heating or filling.

• Vertical, angled or inverted position.

• Energizing may take place immediately after completion of termination.

– COLD SHRINK TERMINATION

CABLE TERMINATIONS

SEPARABLE ELBOW CONNECTOR ASCA for polymeric cables – Deadbreak operation – Rating 250A

INDOOR/OUTDOOR COLD SHRINK TERMINATION for polymeric cables up to 36kV

PCT-1-07/18Technical information subject

to change without notice

APPLICATION

Utilisation

For connection of polymeric MV cables to overhead link, air insulated switchgear and transformers, etc.

Cables

Single core or three core polymeric insulation (PE, XLPE, EPR ...).

Copper or aluminium conductors, solid or stranded. Semi-conducting screen either extruded or taped. Metallic screen of tape, wire or polylam type. Insulation voltage up to 36 kV. Conductor sizes: 25 to 630 mm2. With armour layer or without armour layer.

STANDARDS Generally meets the requirements of IEC60502-4,

GB/T12076.4 - AS4805.1, AS/NZS 4325.1

QUALITY ASSURANCE The Company has been assessed by third party and found in conformity the requirements of the standard ISO 9001 - EN 29001.

SELECTION TABLE

REFERENCE:INDOOR TERMINATION: PCTIOUTDOOR TERMINAITON: PCTO

Voltage Level (kV)

Cross section (mm2)

Indoor Termination Outdoor Termination Single Core Three Cores Single Core Three Cores

24

25-50 PCTI-1C-24-G PCTI-3C-24-G PCTO-1C-24-G PCTO-3C-24-G 70-120 PCTI-1C-24-H PCTI-3C-24-H PCTO-1C-24-H PCTO-3C-24-H

150-240 PCTI-1C-24-I PCTI-3C-24-I PCTO-1C-24-I PCTO-3C-24-I 300-400 PCTI-1C-24-J PCTI-3C-24-J PCTO-1C-24-J PCTO-3C-24-J 500-630 PCTI-1C-24-K PCTI-3C-24-K PCTO-1C-24-K PCTO-3C-24-K

36 25-120 PCTI-1C-36-L PCTI-3C-36-L PCTO-1C-36-L PCTO-3C-36-L

150-300 PCTI-1C-36-M PCTI-3C-36-M PCTO-1C-36-M PCTO-3C-36-M 400-630 PCTI-1C-36-O PCTI-3C-36-O PCTO-1C-36-O PCTO-3C-36-O

INSTALLATION FEATURES

No need for special tools, no heating or filling. Vertical, angled or inverted position. Energizing may take place immediately after

completion of termination.

Cable Lug

Cold ShrinkTermination Sleeve

Cold Shrink Core Sleeve

Cold Shrink Breakout

Cable lug

Cold shrink termination sleeve

Cold shrink core sleeve

Cold shrink breakout

12 www.prysmiancable.com.au | www.prysmiancable.co.nz

Page 13: Creating life long relationships

CABLE TERMINATIONS

SELECTION GUIDE – TERMFIT™

PCTI – Indoor termination PCTO – Outdoor termination

12 kVProduct code

12 kVProduct code

Single core Three core Single core Three core

35-50 PCTI-1C-12-A-T3 PCTI-3C-12-A-T3 35-50 PCTO-1C-12-A-T3 PCTO-3C-12-A-T3

70-120 PCTI-1C-12-B-T3 PCTI-3C-12-B-T3 70-120 PCTO-1C-12-B-T3 PCTO-3C-12-B-T3

150-185 PCTI-1C-12-C-T3 PCTI-3C-12-C-T3 150-185 PCTO-1C-12-C-T3 PCTO-3C-12-C-T3

240-300 PCTI-1C-12-D-T3 PCTI-3C-12-D-T3 240-300 PCTO-1C-12-D-T3 PCTO-3C-12-D-T3

400-630 PCTI-1C-12-E-T3 PCTI-3C-12-E-T3 400-630 PCTO-1C-12-E-T3 PCTO-3C-12-E-T3

24 kV Single core Three core 24 kV Single core Three core

35-50 PCTI-1C-24-G-T3 PCTI-3C-24-G-T3 35-50 PCTO-1C-24-G-T3 PCTO-3C-24-G-T3

70-150 PCTI-1C-24-H-T3 PCTI-3C-24-H-T3 70-150 PCTO-1C-24-H-T3 PCTO-3C-24-H-T3

185-300 PCTI-1C-24-I-T3 PCTI-3C-24-I-T3 185-300 PCTO-1C-24-I-T3 PCTO-3C-24-I-T3

400-500 PCTI-1C-24-J-T3 PCTI-3C-24-J-T3 400-500 PCTO-1C-24-J-T3 PCTO-3C-24-J-T3

630 PCTI-1C-24-K-T3 PCTI-3C-24-K-T3 630 PCTO-1C-24-K-T3 PCTO-3C-24-K-T3

36 kV Single core Three core 36 kV Single core Three core

35-150 PCTI-1C-36-L-T3 PCTI-3C-36-L-T3 35-150 PCTO-1C-36-L-T3 PCTO-3C-36-L-T3

185-300 PCTI-1C-36-M-T3 PCTI-3C-36-M-T3 185-300 PCTO-1C-36-M-T3 PCTO-3C-36-M-T3

400-630 PCTI-1C-36-N-T3 PCTI-3C-36-N-T3 400-630 PCTO-1C-36-N-T3 PCTO-3C-36-N-T3

13www.prysmiancable.com.au | www.prysmiancable.co.nz

Page 14: Creating life long relationships
Page 15: Creating life long relationships

CONNECTORS

15www.prysmiancable.com.au | www.prysmiancable.co.nz

Page 16: Creating life long relationships

16 www.prysmiancable.com.au | www.prysmiancable.co.nz

Description

Separable straight connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 12.7/22 (24) kV. Rating 250 A – Interface A.

Utilisation

• For connection to transformers, switch gear units, motors, etc.

• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.

• Continuous 250 A rms

• Overload 300 A rms (8 hours per 24-hour period).

• Dead-break operated.

• Voltage detection through an integrated capacitive voltage divider.

Cables

• Single core polymeric insulation (PE, XLPE, EPR).

• Copper or aluminium conductor, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of copper tape, copper wires or polylam type.

• Insulation voltage up to 12.7/22 (24) kV.

• Conductor sizes: 25 to 95 mm². For cables with other sizes, please contact us.

Standards

Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051, C 33-001.

Interfaces: CENELEC EN 50180 & EN 50181.

Mechanical conductor contact: IEC 61238-1 class A.

Packing

Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx.) of kit: 3 kg/0.006 m3.

Other products

• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.

• Separable elbow connector MSCE/EC-250-A.

Installation features

• For voltage class 24 kV, one product reference only allows to cover cross from 25 mm² to 95 mm², copper or aluminium conductor.

• No need for special tools, no heating, taping or filling.

• Vertical, angled or inverted position.

• No minimum distance between phases.

• Individual clamping by stainless steel brace.

• The three phases may also be locked together and to the equipment by use of metallic rings (supplied on request, separately or already fitted onto the molded groove).

• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.

• An unplugged connector must never be energized.

STRAIGHT CONNECTOR – MSCS/EC-250-A

DEADBREAK SEPARABLE CONNECTORS

A mark of

FT N

°358

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

250

- V2

May

201

8

Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A

Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A

1/3

EC

INTERFACEA/250 A

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.

Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.

Product Application and Design

A mark of

FT N

°358

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

250

- V2

May

201

8

Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A

Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A

1/3

EC

INTERFACEA/250 A

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.

Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.

Product Application and Design

Page 17: Creating life long relationships

17www.prysmiancable.com.au | www.prysmiancable.co.nz

SELECTION GUIDE – MSCS/EC-250-A

VoltageUm

Diameter over insulation (mm) Conductor size (mm2)*1

Kit referenceMin. Max. Min. Max.

12 kV 11.8 23.2 25 95 MSCS/EC-250-A-12-25/95*2

17 kV 11.8 23.2 25 95 MSCS/EC-250-A-17-25/95*2

24 kV 17.2 25.0 25 95 MSCS/EC-250-A-24-25/95

*1 For guidance only. *2 Models with adapters.

EARTHING DEVICE

Type of metallic screen of cable Reference

Polyam T1

Copper tape T2

Copper wires T3

INTERFACE FOR SEPARABLE CONNECTORS – TYPE A

According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)

Insulator voltage: 24 kV

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Continuous current: 250 A

D1 Bore: Ø 7.9 mm, depth 32 mm

D2 Ø 31 mm

D3 Ø 32.5 mm

D4 Ø 48.5 mm

L1 48 mm

Utilisation250 A Sliding contact 12 & 24 kV

1. Select the kit corresponding to the insulation voltage Um

in kV and to the diameter over cable insulation.

2. Select suitable earthing device.

Example: 1x50 mm², 22 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCS/EC-250-A-24-T3-25/95.

DEADBREAK SEPARABLE CONNECTORS

Page 18: Creating life long relationships

18 www.prysmiancable.com.au | www.prysmiancable.co.nz

Description

Separable straight connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 400 A – Interface B.

Utilisation

• For connection to transformers, switch gear units, motors, etc.

• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.

• Continuous 400 A rms.

• Overload 600 A rms (8 hours per 24-hour period).

• Dead-break operated.

• Voltage detection through an integrated capacitive voltage divider.

Cables

• Single core polymeric insulation (PE, XLPE, EPR).

• Copper or aluminium conductor, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of copper tape, copper wires or polylam type.

• Insulation voltage up to 19/33 (36) kV.

• Conductor sizes: 25 to 240 mm². For cables with other sizes, please contact us.

Standards

Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, IEEE 386, C 33-051.

Interfaces: CENELEC EN 50180 & EN 50181.

Mechanical conductor contact: IEC 61238-1 class A.

Packing

Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx.) of kit: 4.5 kg/0.01 m3.

Other products

• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400 A, interface B.

• Separable elbow connector MSCE/EC-400-B.

Installation features

• The screen break design enables cable outer sheath testing without removing or dismantling the connector.

• No need for special tools, no heating, taping or filling.

• No minimum distance between phases.

• Individual clamping by stainless steel brace.

• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.

• An unplugged connector must never be energized.

STRAIGHT CONNECTOR – MSCS/EC-400-B

DEADBREAK SEPARABLE CONNECTORS

INTERFACEB/400 A

A mark of

FT N

°359

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

400

- V1

May

201

8

Medium Voltage (MV)Up to 19/33 (36) kVMV separable connectors rating 400 A (interface B) Reference : MSCS/EC-400-B

Separable straight connector with mechanical conductor contact (interface B / 400 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of C 33-051 - CENELEC HD 629.1 S2 – IEC 60502-4 - IEEE 386Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A.

1/3

EC

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc.• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 400 A rms.• Overload 600 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductors, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen copper tape, copper wires or polylam type.• Insulation voltage up to 19/33 (36) kV.• Conductor sizes: 25 to 240mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 4.5 kg / 0.01 m3.

Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A, interface B.• Separable Elbow Connector MSCE/EC-400-B.

Product Application and Design

A mark of

FT N

°358

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

250

- V2

May

201

8

Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A

Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A

1/3

EC

INTERFACEA/250 A

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.

Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.

Product Application and Design

Page 19: Creating life long relationships

19www.prysmiancable.com.au | www.prysmiancable.co.nz

SELECTION GUIDE – MSCS/EC-400-B

VoltageUm

Diameter over insulation (mm) Conductor size (mm2)*Kit reference

Min. Max. Min. Max.

12 kV13.0 22.3 25 120 MSCS/EC-400-B-12-rA-25/120

16.1 26.3 95 240 MSCS/EC-400-B-12-rB-95/240

17 kV

13.0 22.3 25 70 MSCS/EC-400-B-17-rA-25/70

16.1 26.3 35 120 MSCS/EC-400-B-17-rB-35/120

20.2 30.8 95 240 MSCS/EC-400-B-17-rC-95/240

24 kV

16.1 26.3 25 150 MSCS/EC-400-B-24-rB-25/150

16.1 26.3 70 185 MSCS/EC-400-B-24-rB-70/185

20.2 30.8 95 240 MSCS/EC-400-B-24-rC-95/240

22.7 33.0 95 240 MSCS/EC-400-B-24-rD-95/240

36 kV

20.2 30.8 25 95 MSCS/EC-400-B-36-rC-25/95

22.7 33.0 35 120 MSCS/EC-400-B-36-rD-35/120

25.6 35.3 70 240 MSCS/EC-400-B-36-rE-70/240

* For guidance only.

INTERFACE FOR SEPARABLE CONNECTORS – TYPE B2

According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)

Insulator voltage: 36 kV

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Continuous current: 400 A

D1 Bore: Ø 14 mm, depth 40 mm

D2 Ø 46 mm

D3 Ø 56 mm

D4 Ø 70 mm

L1 90 mm

Utilisation400 A Sliding contact 12, 24 & 36 kV

1. Select the kit corresponding to the insulation voltage Um

in kV and to the diameter over cable insulation.

2. Select suitable earthing device.

Example: 1x50 mm², 20 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCS/EC-400-B-24-rB-T3-25/150.

DEADBREAK SEPARABLE CONNECTORS

EARTHING DEVICE

Type of metallic screen of cable Reference

Polyam T1

Copper tape T2

Copper wires T3

Page 20: Creating life long relationships

20 www.prysmiancable.com.au | www.prysmiancable.co.nz

INTERFACEB/400 A

A mark of

FT N

°359

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

400

- V1

May

201

8

Medium Voltage (MV)Up to 19/33 (36) kVMV separable connectors rating 400 A (interface B) Reference : MSCS/EC-400-B

Separable straight connector with mechanical conductor contact (interface B / 400 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of C 33-051 - CENELEC HD 629.1 S2 – IEC 60502-4 - IEEE 386Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A.

1/3

EC

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc.• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 400 A rms.• Overload 600 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductors, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen copper tape, copper wires or polylam type.• Insulation voltage up to 19/33 (36) kV.• Conductor sizes: 25 to 240mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 4.5 kg / 0.01 m3.

Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A, interface B.• Separable Elbow Connector MSCE/EC-400-B.

Product Application and Design

Description

Separable straight connector. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 400 A – Interface B.

Utilisation

• For connection to transformers, switch gear units, motors, etc.

• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.

• Continuous 400 A rms.

• Overload 600 A rms (8 hours per 24-hour period).

• Dead-break operated.

• Voltage detection through an integrated capacitive voltage divider.

Cables

• Single core polymeric insulation (XLPE).

• Copper or aluminium conductor, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of copper tape, copper wires or polylam type.

• Insulation voltage up to 19/33 (36) kV.

• Conductor sizes: 25 to 300 mm². For cables with other sizes, please contact us.

Standards

Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051.

Interfaces: CENELEC EN 50180 & EN 50181.

Packing

Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4.5 kg/0.01 m3.

Other products

• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400 A, interface B.

Installation features

• No need for special tools, no heating, taping or filling.

• Vertical, angled or inverted position.

• No minimum distance between phases.

• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.

• Individual clamping by stainless steel brace.

• An unplugged connector must never be energized.

STRAIGHT CONNECTOR – FMCS-400

DEADBREAK SEPARABLE CONNECTORS

FT N

°345

Sep

arab

le S

trai

ght C

onne

ctor

FM

CS 4

00 -

V1 M

ay 2

018

Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400

Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181

Utilisation• For connection of polymeric MV cables to transformers, switchgear units,

motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a

watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage

divider.

Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.

Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3

Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,

interface B.

1/2

Product Application and Design

INTERFACEB / 400 A

®

Prysmian Group Sales department - mail : [email protected]

A mark of

Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end

plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized

Page 21: Creating life long relationships

21www.prysmiancable.com.au | www.prysmiancable.co.nz

EARTHING DEVICE LUG

Type of metallic screen of cable Reference Type of

conductor Reference

Polyam T1 Copper C + conductor size in mm2

Copper tape T2 Aluminium A + conductor size in mm2

Copper wires T3 Aluminium* + lug for hexagonal crimping required

A + conductor size in mm2

+ DIN

SELECTION GUIDE – FMCS-400

Kit referenceDiameter over insulation

(mm)

Voltage Um

12 kV 17.5 kV 24 kV 36 kV

Conductor size (mm2)*1

Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

FMCS-400-Z 18.5 20.5 70 95 50 70 35 50 – –

FMCS-400-A 19.9 21.9 95 120 70 95 50 70 – 25

FMCS-400-B 21.4 23.5 120 150 95 120 70 95 25 35

FMCS-400-C 22.9 25.1 150 185 120 150 95 120 35 50

FMCS-400-D 24.4 26.6 185 240 150 185 120 150 50 70

FMCS-400-E 26.0 28.3 240 300* 185 240 150 185 70 95

FMCS-400-F 27.8 30.4 300*2 – 240 300* 185 – 95 120

FMCS-400-G 29.8 32.7 – – 300*2 – 240 240 120/150 150

FMCS-400-H 31.8 35.3 – – – – 300*2 300*2 185 240

FMCS-400-J 34.1 38.3 – – – – – – 240 300*2

*1 For guidance only. *2 For 300 sqmm, please contact us.

Note! For cables with bonded outer semi-conducting layer: carefully check the diameter over insulation after removal of the outer semi-conducting layer.

INTERFACE FOR SEPARABLE CONNECTORS – TYPE B2

According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)

Insulator voltage: 36 kV

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Continuous current: 400 A

D1 Bore: Ø 14 mm, depth 40 mm

D2 Ø 46 mm

D3 Ø 56 mm

D4 Ø 70 mm

L1 90 mm

Utilisation400 A Sliding contact 12, 24 & 36 kV

1. Select the kit corresponding to the diameter over cable insulation.

2. Specify the insulation voltage Um in kV.

3. Select suitable earthing device.

4. Select suitable lug.

Example: 1x95 mm², 33 kV polymeric cable, diameter over insulation 29.3 mm, with copper wire screen, aluminium conductor: FMCS-400-F-36-T3-A95.

DEADBREAK SEPARABLE CONNECTORS

*available for deep indenting a hexagonal crimping. Unless other wise stated, standard delivery will be with deep indenting. Suitable tooling to be used.

Page 22: Creating life long relationships

22 www.prysmiancable.com.au | www.prysmiancable.co.nz

A mark of

FT N

°360

MSC

E/EC

-250

-A (i

nter

face

A /

250

A) -

V2M

ay 2

018

Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCE/EC -250-A

Separable elbow connector with mechanical conductor contact (interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - EC 60502-4 - C 33-051 -C 33-001Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A

1/3

EC

INTERFACEA/250 A

Prysmian Group Sales department - mail : [email protected]

Utilisation • For connection of polymeric MV cables to transformers, switchgear units, motors,

etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight

conductive envelope connected to earth. • Continuous 250 A rms. • Overload 300 A rms (8 hours per 24-hour period). • Deadbreak operation.• Voltage detection through an integrated capacitive voltage divider.

Cables • Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminum conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.

Other products• Associated products such as bushing FMBOm-250, FMBOh-250 and accessories for separable connectors 250A, interface B.• Separable straight connector MSCS/EC-250-A.

Product Application and Design

Description

Separable elbow connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 12.7/22 (24) kV. Rating 250 A – Interface A.

Utilisation

• For connection to transformers, switch gear units, motors, etc.

• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.

• Continuous 250 A rms

• Overload 300 A rms (8 hours per 24-hour period).

• Dead-break operated.

• Voltage detection through an integrated capacitive voltage divider.

Cables

• Single core polymeric insulation (PE, XLPE, EPR).

• Copper or aluminium conductor, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of copper tape, copper wires or polylam type.

• Insulation voltage up to 12.7/22 (24) kV.

• Conductor sizes: 25 to 95 mm². For cables with other sizes, please contact us.

Standards

Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051, C 33-001.

Interfaces: CENELEC EN 50180 & EN 50181.

Mechanical conductor contact: IEC 61238-1 class A.

Packing

Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 3 kg/0.006 m3.

Other products

• Associated products such as bushing FMBOm-250, FMBOh-250 and accessories for separable connectors 250A, interface A.

• Separable straight connector MSCS/EC-250-A.

Installation features

• For voltage class 24 kV, one product reference only allows to cover cross from 25 mm² to 95 mm², copper or aluminium conductor.

• No need for special tools, no heating, taping or filling.

• Vertical, angled or inverted position.

• No minimum distance between phases.

• Individual clamping by stainless steel brace.

• The three phases may also be locked together and to the equipment by use of metallic rings (supplied on request, separately or already fitted onto the molded groove).

• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.

• An unplugged connector must never be energized.

ELBOW CONNECTOR – MSCE/EC-250-A

DEADBREAK SEPARABLE CONNECTORS

A mark of

FT N

°358

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

250

- V2

May

201

8

Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A

Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A

1/3

EC

INTERFACEA/250 A

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.

Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.

Product Application and Design

Page 23: Creating life long relationships

23www.prysmiancable.com.au | www.prysmiancable.co.nz

SELECTION GUIDE – MSCE/EC-250-A

VoltageUm

Diameter over insulation (mm) Conductor size (mm2)*1

Kit referenceMin. Max. Min. Max.

12 kV 11.8 23.2 25 95 MSCE/EC-250-A-12-25/95*2

17 kV 11.8 23.2 25 95 MSCE/EC-250-A-17-25/95*2

24 kV 17.2 25.0 25 95 MSCE/EC-250-A-24-25/95

*1 For guidance only. *2 Models with adapters.

EARTHING DEVICE

Type of metallic screen of cable Reference

Polyam T1

Copper tape T2

Copper wires T3

INTERFACE FOR SEPARABLE CONNECTORS – TYPE A

According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)

Insulator voltage: 24 kV

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Continuous current: 250 A

D1 Bore: Ø 7.9 mm, depth 32 mm

D2 Ø 31 mm

D3 Ø 32.5 mm

D4 Ø 48.5 mm

L1 48 mm

Utilisation250 A Sliding contact 12 & 24 kV

1. Select the kit corresponding to the insulation voltage Um

in kV and to the diameter over cable insulation.

2. Select suitable earthing device.

Example: 1x50 mm², 22 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCE/EC-250-A-24-T3-25/95.

DEADBREAK SEPARABLE CONNECTORS

Page 24: Creating life long relationships

24 www.prysmiancable.com.au | www.prysmiancable.co.nz

Description

Separable elbow connector. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 400 A – Interface B.

Utilisation

• For connection to transformers, switch gear units, motors, etc.

• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.

• Continuous 400 A rms.

• Overload 600 A rms (8 hours per 24-hour period).

• Dead-break operated.

• Voltage detection through an integrated capacitive voltage divider.

Cables

• Single core polymeric insulation (XLPE).

• Copper or aluminium conductor, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of copper tape, copper wires or polylam type.

• Insulation voltage up to 19/33 (36) kV.

• Conductor sizes: 25 to 240 mm². For cables with other sizes, please contact us.

Standards

Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051, C 33-001.

Interfaces: CENELEC EN 50180 & EN 50181.

Packing

Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 6 kg/0.013 m3.

Other products

• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400 A, interface B.

Installation features

• No need for special tools, no heating, taping or filling.

• Vertical, angled or inverted position.

• No minimum distance between phases.

• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.

• Individual clamping by stainless steel brace.

• An unplugged connector must never be energized.

ELBOW CONNECTOR – FMCE-400

DEADBREAK SEPARABLE CONNECTORS

FT N

°324

Sep

arab

le E

lbow

Con

nect

or F

MCE

400

- V1

May

201

8

Medium Voltage (MV)Up to 19/33 (36) kVMV Separable connectors rating 400A (Interface B)Rating 400A (interface B) Reference: FMCE 400

A mark of

Separable elbow connector(interface B/400A)For polymeric cables - Deadbreak - OperationGenerally meets the requirements of C 33-051 - C 33-001 - HD629.1 S2 - IEC 60502-4 Interfaces: CENELEC EN 50180 – EN 50181

1/3

INTERFACEB/400A

®

Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end

plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized.

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors,

etc...• Indoor and outdoor installation. The connector is entirely protected by a watertight

conductive envelope connected to earth.• Continuous 400 A rms.

overload 600 A rms (8 hours per 24-hour period).• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 240 mm2 (or 300) mm2.

Packing • Supplied as a kit for 3 single connectors containing all the necessary components.

Shipping weight and volume (approx) of kit: 6 kg / 0,013 m3.

Other products• Associated products such as bushing FMBOm-400 and accessories for separable

connectors 400A, interface B.

Product Application and Design

FT N

°345

Sep

arab

le S

trai

ght C

onne

ctor

FM

CS 4

00 -

V1 M

ay 2

018

Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400

Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181

Utilisation• For connection of polymeric MV cables to transformers, switchgear units,

motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a

watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage

divider.

Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.

Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3

Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,

interface B.

1/2

Product Application and Design

INTERFACEB / 400 A

®

Prysmian Group Sales department - mail : [email protected]

A mark of

Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end

plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized

Page 25: Creating life long relationships

25www.prysmiancable.com.au | www.prysmiancable.co.nz

EARTHING DEVICE LUG

Type of metallic screen of cable Reference Type of

conductor Reference

Polyam T1 Copper C + conductor size in mm2

Copper tape T2 Aluminium A + conductor size in mm2

Copper wires T3 Aluminium* + lug for hexagonal crimping required

A + conductor size in mm2

+ DIN

SELECTION GUIDE – FMCE-400

Kit referenceDiameter over insulation

(mm)

Voltage Um

12 kV 17.5 kV 24 kV 36 kV

Conductor size (mm2)*1

Min. Max. Min. Max. Min. Max. Min. Max. Min. Max.

FMCE-400-Z 18.5 20.5 70 95 50 70 35 50 – –

FMCE-400-A 19.9 21.9 95 120 70 95 50 70 – 25

FMCE-400-B 21.4 23.5 120 150 95 120 70 95 25 35

FMCE-400-C 22.9 25.1 150 185 120 150 95 120 35 50

FMCE-400-D 24.4 26.6 185 240 150 185 120 150 50 70

FMCE-400-E 26.0 28.3 240 300* 185 240 150 185 70 95

FMCE-400-F 27.8 30.4 300*2 – 240 300*2 185 – 95 120

FMCE-400-G 29.8 32.7 – – – – 240 240 120/150 150

FMCE-400-H 31.8 35.3 – – – – 300*2 300*2 185 240

FMCE-400-J 34.1 38.3 – – – – – – 240 300*2

*1 For guidance only. *2 For 300 sqmm, please contact us.

Note! For cables with bonded outer semi-conducting layer: carefully check the diameter over insulation after removal of the outer semi-conducting layer.

INTERFACE FOR SEPARABLE CONNECTORS – TYPE B2

According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)

Insulator voltage: 36 kV

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Continuous current: 400 A

D1 Bore: Ø 14 mm, depth 40 mm

D2 Ø 46 mm

D3 Ø 56 mm

D4 Ø 70 mm

L1 90 mm

Utilisation400 A Sliding contact 12, 24 & 36 kV

1. Select the kit corresponding to the diameter over cable insulation.

2. Specify the insulation voltage Um in kV.

3. Select suitable earthing device.

4. Select suitable lug.

Example: 1x95 mm², 33 kV polymeric cable, diameter over insulation 29.5 mm, with copper wire screen, aluminium conductor: FMCE-400-F-36-T3-A95.

DEADBREAK SEPARABLE CONNECTORS

*available for deep indenting a hexagonal crimping. Unless other wise stated, standard delivery will be with deep indenting. Suitable tooling to be used.

Page 26: Creating life long relationships

26 www.prysmiancable.com.au | www.prysmiancable.co.nz

A mark of

FT N

°362

Sep

arab

le T

ee C

onne

ctor

MSC

T EC

630

C -

V1 M

ay 2

018

Medium Voltage (MV)Up to 19/33 (36) kVMV separable connectors rating 630 A (interface C) Reference : MSCT/EC-630-C

Separable elbow connector with mechanical conductor contact (interface C / 630 A)For polymeric cables – Deadbreak operation Generally meets the requirements of C 33-051 - CENELEC HD 629.1 S2 – IEC 60502-4Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A.

1/4

EC

INTERFACEC/630 A

Installation features• The screen break design enables cable outer sheath testing without removing or dismantling the connector.• No need for special tools, no heating, taping or filling.• Vertical, angled or inverted position.• No minimum distance between phases.• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug . • An unplugged connector must never be energized.

Prysmian Group Sales department - mail : [email protected]

UtilisationFor connection of polymeric MV cables to transformers, switchgear units,motors, etc.• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 630 A rms.• Overload 900 A rms (8 hours per 24-hour period).• Deadbreak operation.• Voltage detection through an integrated capacitive voltage divider.

Cable• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 19/33 (36) kV.• Conductor sizes: 25 to 300 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 6 kg / 0,013 m3.

Other productsAssociated products such as bushing FMBOS 400 and accessories for separable connectors 630A, interface C.

Product Application and Design

Description

Separable tee connector with mechanical conductor contact. For polymeric medium voltage (MV) cables up to 19/33 (36) kV. Rating 630 A – Interface C.

Utilisation

• For connection to transformers, switch gear units, motors, etc.

• Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.

• Continuous 630 A rms.

• Overload 900 A rms (8 hours per 24-hour period).

• Dead-break operated.

• Voltage detection through an integrated capacitive voltage divider.

Cables

• Single core polymeric insulation (PE, XLPE, EPR).

• Copper or aluminium conductor, solid or stranded.

• Semi-conducting screen either extruded or taped.

• Metallic screen of copper tape, copper wires or polylam type.

• Insulation voltage up to 19/33 (36) kV.

• Conductor sizes: 25 to 300 mm². For cables with other sizes, please contact us.

Standards

Generally meets the requirements of CENELEC HD 629.1 S2, IEC 60502-4, C 33-051.

Interfaces: CENELEC EN 50180 & EN 50181.

Mechanical conductor contact: IEC 61238-1 class A.

Packing

Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 6 kg/0.013 m3.

Other products

• Associated products such as bushing FMBOm-400 and accessories for separable connectors 630 A, interface C.

Installation features

• The screen break design enables cable outer sheath testing without removing or dismantling the connector.

• No need for special tools, no heating, taping or filling.

• Vertical, angled or inverted position.

• No minimum distance between phases.

• Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end plug.

• An unplugged connector must never be energized.

TEE CONNECTOR – MSCT/EC-630-C

DEADBREAK SEPARABLE CONNECTORS

A mark of

FT N

°358

Sep

arab

le S

trai

ght C

onne

ctor

MSC

S EC

250

- V2

May

201

8

Medium Voltage (MV)Up to 12.7/22 (24) kVMV separable connectors rating 250 A (interface A) Reference : MSCS/EC-250-A

Separable straight connector with mechanical conductor contact(interface A / 250 A)For polymeric cables – Deadbreak operationGenerally meets the requirements of CENELEC HD 629.1 S2 - IEC 60502-4 - C 33-051 - C 33-001 Interfaces: CENELEC EN 50180 – EN 50181Mechanical conductor contact: IEC 61238-1 class A

1/3

EC

INTERFACEA/250 A

Prysmian Group Sales department - mail : [email protected]

Utilisation• For connection of polymeric MV cables to transformers, switchgear units, motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a watertight conductive envelope connected to earth.• Continuous 250 A rms overload 300 A rms (8 hours per 24-hour period).• Dead-break operated.• Voltage detection through an integrated capacitive voltage divider.

Cables• Single core polymeric insulation (PE, XLPE, EPR …).• Copper or aluminium conductor, solid or stranded.• Semi-conducting screen either extruded or taped.• Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 12.7/22 (24) kV.• Conductor sizes: 25 to 95 mm².

Packing Supplied as a kit of 3 single connectors containing all the necessary components.Shipping weight and volume (approx) of kit : 3 kg / 0,006 m3.

Other products• Associated products such as bushing FMBOm-250, FMBOh-250 for separable connectors 250 A and accessories interface A.• Separable elbow connector MSCE/EC-250-A.

Product Application and Design

Page 27: Creating life long relationships

27www.prysmiancable.com.au | www.prysmiancable.co.nz

INTERFACE FOR SEPARABLE CONNECTORS – TYPE C1

According to CENELEC EN 50180 & EN 50181. Medium Voltage (MV)

Insulator voltage: 36 kV

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Continuous current: 630 A

D1 Thread: M16, depth 29 mm

D2 Ø 46 mm

D3 Ø 56 mm

D4 Ø 70 mm

L1 90 mm

Utilisation630 A Bolted contact 12, 24 & 36 kV

SELECTION GUIDE – MSCT/EC-630-C

VoltageUm

Diameter over insulation (mm) Conductor size (mm2)*Kit reference

Min. Max. Min. Max.

12 kV

13.0 22.3 25 120 MSCT/EC-630-C-12-rA-25/120

16.1 26.3 95 240 MSCT/EC-630-C-12-rB-95/240

22.7 33.0 185 300 MSCT/EC-630-C-12-rD-185/300

17 kV

13.0 22.3 25 70 MSCT/EC-630-C-17-rA-25/70

16.1 26.3 35 120 MSCT/EC-630-C-17-rB-35/120

20.2 30.8 95 240 MSCT/EC-630-C-17-rC-95/240

25.6 35.3 185 300 MSCT/EC-630-C-17-rE-185/300

24 kV

16.1 26.3 25 150 MSCT/EC-630-C-24-rB-25/150

16.1 26.3 70 150 MSCT/EC-630-C-24-rB-70/150

20.2 30.8 95 240 MSCT/EC-630-C-24-rC-95/240

22.7 33.0 95 240 MSCT/EC-630-C-24-rD-95/240

25.6 35.3 185 300 MSCT/EC-630-C-24-rE-185/300

36 kV

20.2 30.8 25 95 MSCT/EC-630-C-36-rC-25/95

22.7 33.1 35 120 MSCT/EC-630-C-36-rD-35/120

25.6 35.3 70 240 MSCT/EC-630-C-36-rE-70/240

30.5 40.6 150 300 MSCT/EC-630-C-36-rF-150/300

* For guidance only.

1. Select the kit corresponding to the insulation voltage Um

in kV and to the diameter over cable insulation.

2. Select suitable earthing device.

Example: 1x95 mm², 20 kV polymeric cable, diameter over insulation 21.5 mm, with copper wire screen, aluminium conductor: MSCT/EC-630-C-24-rC-T3-95/240.

DEADBREAK SEPARABLE CONNECTORS

EARTHING DEVICE

Type of metallic screen of cable Reference

Polyam T1

Copper tape T2

Copper wires T3

Page 28: Creating life long relationships

Sep

arab

le C

onn

ecto

rsA

CC

ES

SO

RIE

S F

OR

40

0A

TE

E C

ON

NE

CT

OR

S

Section 5 :Seperable Connectors

All

pri

ces

are

sub

ject

to

our

Ter

ms

and

Co

ndit

ions

of

Sal

e -

see

insi

de

fro

nt c

ove

r fo

r m

ore

det

ails

Pag

e 69

Prod

ucts

with

pric

es in

BO

LDar

e m

ade

to o

rder

and

are

sub

ject

to a

min

imum

ord

er q

uant

ity •

All

othe

r ite

ms

are

norm

ally

exs

tock

, sub

ject

to re

mai

ning

uns

old.

Con

firm

atio

n w

ill be

mad

e at

tim

e of

ord

er

INSU

LATI

NG P

LUG

Expo

xy re

sin

mou

ld w

hich

pro

vide

s de

ad-e

nd fa

cilit

y fo

r sep

arab

le te

e co

nnec

tors

.

Insu

latin

g P

lug

12

kV

- r

atin

g 4

00

AF

MP

I-4

00

-12

29

.23

Insu

latin

g P

lug

24

kV

- r

atin

g 4

00

AF

MP

I-4

00

-24

29

.23

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

Sta

nd

Off

Plu

g 1

2kV

- r

atin

g 4

00

AF

MP

S-4

00

-12

12

1.6

0

Sta

nd

Off

Plu

g 2

4kV

- r

atin

g 4

00

AF

MP

S-4

00

-24

12

1.6

0

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

STAN

D OF

F PL

UGED

PM m

ould

ing

whi

ch is

des

igne

d to

pro

ivde

sup

port

and

dead

-end

sep

arab

le c

onne

ctor

whe

n re

mov

ed fr

om th

e eq

uipm

ent.

Str

aig

ht

Co

nn

ectio

n P

lug

12

kV

- r

atin

g 4

00

AF

MP

Cs-4

00

-12

14

1.2

0

Str

aig

ht

Co

nn

ectio

n P

lug

24

kV

- r

atin

g 4

00

AF

MP

Cs-4

00

-24

14

1.2

0

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

STRA

IGHT

CON

NECT

ION

PLUG

Expo

xy re

sin

mou

ldin

g ov

er a

cop

per r

od fo

r con

nect

ing

two

sepa

rabl

e te

e co

nnec

tors

FM

CTs-

400.

Ea

rth

ing

Plu

g -

ra

tin

g 4

00

AF

MP

E-4

00

22

8.3

3

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

EART

HING

PLU

GED

PM m

ould

ing

desi

gned

to s

uppo

rt an

d ea

rth s

epar

able

con

nect

ors

whe

n re

mov

ed fr

om th

e eq

uipm

ent.

12

05

0F

MC

Ts-6

00

/12

50

-A2

08

.92

15

07

0F

MC

Ts-6

00

/12

50

-B2

12

.18

-9

5F

MC

Ts-6

00

/12

50

-C2

09

.64

18

51

20

FM

CT

s-6

00

/12

50

-D2

12

.18

24

01

50

FM

CT

s-6

00

/12

50

-E2

08

.92

30

01

85

FM

CT

s-6

00

/12

50

-G2

09

.64

-2

40

FM

CT

s-6

00

/12

50

-H2

08

.92

40

03

00

FM

CT

s-6

00

/12

50

-J2

14

.76

50

04

00

FM

CT

s-6

00

/12

50

-L2

14

.76

63

0-

FM

CT

s-6

00

/12

50

-M2

21

.47

-5

00

FM

CT

s-6

00

/12

50

-N2

22

.15

-6

30

FM

CT

s-6

00

/12

50

-Q2

21

.47

Co

nd

uc

tor

Siz

e

mm

2 1

2k

V

Co

nd

uc

tor

Siz

e

mm

2 2

4k

VR

ef.

No

.P

ric

e £

ea

ch

SEPA

RABL

E TE

E CO

NNEC

TORS

TEE

CONN

ECTO

RTo

sui

t pol

ymer

ic c

able

s up

to 2

4kV

- non

-load

brea

k op

erat

ion

- rat

ing

1250

A (w

ith c

lam

ping

scr

ew).

Volta

ge C

lass

: kV

Earth

ing

Kit :

T1

(Pol

ylam

) T2

(Cop

per T

ape)

T3

(Cop

per W

ire)

Cond

ucto

r Typ

e an

d si

ze in

mm

2: “

A”(A

lum

iniu

m) -

mm

2 "C

" (C

oppe

r) - m

m2

To s

elec

t - R

ef.n

o +

Volta

ge c

lass

+ E

arth

ing

kit +

Con

duct

or ty

pe &

siz

e m

m2

Note

: Ty

pica

l exa

mpl

e fo

r a 2

4kV

tee

conn

ecto

r for

300

mm

2 ,cop

per w

iresc

reen

cab

le a

lum

iniu

m c

ondu

ctor

: FM

CTs-

600/

1250

-J-2

4-T3

-A30

0Sep

arab

le C

onn

ecto

rsA

CC

ES

SO

RIE

S F

OR

40

0A

& 6

00

/12

50

A T

EE

CO

NN

EC

TO

RS

www.pirelli.co.uk

Pag

e 70

Pire

lli C

ompo

nent

s U

nit

Com

mer

cial

Enq

uirie

s:te

l 015

1 43

0 36

55

fax

0151

430

363

6

No

rma

l B

ush

ing

- 1

2kV

ra

tin

g 6

00

/12

50

A in

oil

FM

BO

s-6

00

/12

50

-12

14

3.9

6

No

rma

l B

ush

ing

- 2

4kV

ra

tin

g 6

00

/12

50

A in

oil

FM

BO

s-6

00

/12

50

-24

14

3.9

6

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

CABL

E BU

SHIN

GSFo

r use

in o

il ap

plic

atio

ns u

p to

24k

V - n

on-lo

adbr

eak

oper

atio

n - r

atin

g 60

0/12

50A

(scr

ew c

onta

ct).

ACCE

SSOR

IES

FOR

600/

1250

A TE

E CO

NNEC

TORS

Str

aig

ht

Co

nn

ectio

n P

lug

12

kV

- r

atin

g 6

00

/12

50

A

FM

PC

s-6

00

/12

50

-12

13

2.3

0

Str

aig

ht

Co

nn

ectio

n P

lug

24

kV

- r

atin

g 6

00

/12

50

AF

MP

Cs-6

00

/12

50

-24

13

2.3

0

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

STRA

IGHT

CON

NECT

ION

PLUG

Expo

xy re

sin

mou

ldin

g ov

er a

cop

per r

od fo

r con

nect

ing

two

sepa

rabl

e te

e co

nnec

tors

.

Insu

latin

g P

lug

12

kV

- r

atin

g 6

00

/12

50

AF

MP

I-6

00

/12

50

-12

41

.90

Insu

latin

g P

lug

24

kV

- r

atin

g 6

00

/12

50

AF

MP

I-6

00

/12

50

-24

41

.90

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

INSU

LATI

NG P

LUG

Epox

y re

sin

mou

ld w

hich

pro

vide

s de

ad-e

nd fa

cilit

y fo

r sep

arab

le te

e co

nnec

tors

.

Re

du

cin

g P

lug

12

kV

- r

atin

g 6

00

AF

MP

R-6

00

-12

18

1.2

0

Re

du

cin

g P

lug

24

kV

ra

tin

g 6

00

AF

MP

R-6

00

-24

18

1.2

0

De

sc

rip

tio

nR

ef.

No

.P

ric

e £

ea

ch

REDU

CING

PLU

G FM

PR -6

00Ep

oxy

resi

n m

ould

whi

ch a

llow

s a

sepa

rabl

e te

e co

nnec

tor F

MCT

s-60

0/12

50 to

acc

ept c

onne

ctor

s of

the

250A

ser

ies.

Separable ConnectorsT E E C O N N E C T O R S & A C C E S S O R I E S F O R 4 0 0 A T E E C O N N E C T O R S

ww

w.p

ire

lli.

co

.uk

Page 68 Pirelli Components Unit Commercial Enquiries: tel 0151 430 3655 fax 0151 430 3636

70 35 FMCTs-400/1250-Z 160.94

120 50 FMCTs-400/1250-A 157.68

150 70 FMCTs-400/1250-B 160.94

- 95 FMCTs-400/1250-C 158.40

185 120 FMCTs-400/1250-D 160.94

240 150 FMCTs-400/1250-E 157.68

300 185 FMCTs-400/1250-G 158.40

- 240 FMCTs-400/1250-H 157.68

400 300 FMCTs-400/1250-J 163.52

500 400 FMCTs-400/1250-L 163.52

- 500 FMCTs-400/1250-N 170.23

- 630 FMCTs-400/1250-Q 170.23

Conductor Size

mm2 12kV

Conductor Size

mm2 24kVRef. No.

Price £each

Normal Bushing - 12kV rating 400A in oil FMBOm-400-12 141.46

Normal Bushing - 24kV 400A in oil FMBOm-400-24 141.76

Ref. No.Price £each

Description

DEAD END RECEPTACLEEDPM moulding which provides a dead-end facility for insulating bushings.

Dead End Receptacle 12kV - rating 400A FMR-400-12 79.69

Dead End Receptacle 24kV - rating 400A FMR-400-24 79.69

Description Ref. No.Price £each

TEE CONNECTORTo suit polymeric cable up to 24kV - non-loadbreak operation - 400 series for 630A (with clamping screw).

ACCESSORIES FOR 400A TEE CONNECTORS

CABLE BUSHINGSFor use in oil applications up to 24kV - non-loadbreak operation - rating 400A.

70 - FMCTs-400-Z 134.32

95 - FMCTs-400-A 133.56

120 25 FMCTs-400-B 133.56

150 35 FMCTs-400-C 133.56

185 50 FMCTs-400-D 133.95

240 70 FMCTs-400-E 137.37

300 95 FMCTs-400-F 135.75

- 120/150 FMCTs-400-G 133.56

- 185 FMCTs-400-H 133.95

- 240 FMCTs-400-J 137.37

Conductor Size

mm2 12kV

Conductor Size

mm2 36kVRef. No.

Price £each

TEE CONNECTORTo suit polymeric cable up to 36kV - non-loadbreak operation - 400 series for 630A (with clamping screw).

Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire) Conductor Type and size in mm2 : “A” (Aluminium) - mm2 "C" (Copper) - mm2

To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2

Note : Typical example for a 12kV tee connector for 95mm2, copper wire screen cable aluminium conductor and socket contact: FMCT-400-A-12-T3-A95.24kV available on request.

Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire)Conductor Type and size in mm2: “A” (Aluminium) - mm2 "C" (Copper) - mm2

To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2

Note : Typical example for a 24kV tee connector for 300mm2, copper wire screen cable aluminium conductor : FMCTs-400/1250-J-24-T3-A300

28 www.prysmiancable.com.au | www.prysmiancable.co.nz

STRAIGHT CONNECTING PLUG – FMPCs-400

• Epoxy resin moulded over a copper rod. For connection of two tee connectors FMCT-400, FMCTs-400 or FMCTXs-630/C in combinations such as disconnectable joint, tee off or dual cable supply.

• Connection to rod by the clamping screws of the connectors. Integral reconstitution of insulation. Protection through screen continuity of connected items.

• Operated when de-energized.

• Packing: per piece.

ACCESSORIES FOR SERIES 400

SEPARABLE CONNECTORS

SELECTION GUIDE – FMPCs-400

VoltageUm

Reference

Interface C/C Interface B/B Interface B/C

12 kV FMPCs-400-C/C-12 FMPCs-400-B/B-12 FMPCs-400-C/C-12

24 kV FMPCs-400-C/C-24 FMPCs-400-B/B-24 FMPCs-400-C/C-24

36 kV FMPCs-400-C/C-36 – –

FT N

°345

Sep

arab

le S

trai

ght C

onne

ctor

FM

CS 4

00 -

V1 M

ay 2

018

Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400

Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181

Utilisation• For connection of polymeric MV cables to transformers, switchgear units,

motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a

watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage

divider.

Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.

Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3

Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,

interface B.

1/2

Product Application and Design

INTERFACEB / 400 A

®

Prysmian Group Sales department - mail : [email protected]

A mark of

Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end

plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized

Description

Accessories for medium voltage separable connectors for series 400, rating 400 A and 630 A. Interfaces B and C.

DEAD-END RECEPTACLE – FMR-400 / FMRs-400

• EPDM moulding with semi-conducting EPDM jacket. Provides a dead-end facility for insulating bushings.

• Operated when de-energized.

• Watertight, slipped on with silicone grease.

• Supplied with locking brace.

• Packing: per piece.

INSULATING PLUG – FMPI-400

• Epoxy resin moulding which provides a dead-end facility for separable tee connectors type FMCT-400 or FMCTs-400.

• Operated when de-energized.

• Includes a capacitive voltage divider that is protected by a cap of semi-conducting EPDM during normal use.

• Packing: per piece.

SELECTION GUIDE – FMR-400 / FMRs-400

VoltageUm

Reference

Interface B Interface C

12 kV FMR-400-12 FMRs-400-12*

24 kV FMR-400-24 FMRs-400-24*

36 kV FMR-400-36 FMRs-400-36*

*Suffix "s" = screw type (for bushings with interface type C).

SELECTION GUIDE – FMPI-400

VoltageUm

Reference

12 kV FMPI-400-12

24 kV FMPI-400-24

36 kV FMPI-400-36

Note! Before using these products, you must check if it is suitable for your intended application. You assume all risks and liability associated with such use. If any doubt, please consult us.

Page 29: Creating life long relationships

Separable ConnectorsA C C E S S O R I E S F O R 4 0 0 A T E E C O N N E C T O R S

Sec

tion

5 :Sepera

ble

Connecto

rs

All prices are subject to our Terms and Conditions of Sale - see inside front cover for more details Page 69Products with prices in BOLD are made to order and are subject to a minimum order quantity • All other items are normally exstock, subject to remaining unsold. Confirmation will be made at time of order

INSULATING PLUGExpoxy resin mould which provides dead-end facility for separable tee connectors.

Insulating Plug 12kV - rating 400A FMPI-400-12 29.23

Insulating Plug 24kV - rating 400A FMPI-400-24 29.23

Description Ref. No.Price £each

Stand Off Plug 12kV - rating 400A FMPS-400-12 121.60

Stand Off Plug 24kV - rating 400A FMPS-400-24 121.60

Description Ref. No.Price £each

STAND OFF PLUGEDPM moulding which is designed to proivde support and dead-end separable connector when removed from the equipment.

Straight Connection Plug 12kV - rating 400A FMPCs-400-12 141.20

Straight Connection Plug 24kV - rating 400A FMPCs-400-24 141.20

Description Ref. No.Price £each

STRAIGHT CONNECTION PLUGExpoxy resin moulding over a copper rod for connecting two separable tee connectors FMCTs-400.

Earthing Plug - rating 400A FMPE-400 228.33

Description Ref. No.Price £each

EARTHING PLUGEDPM moulding designed to support and earth separable connectors when removed from the equipment.

120 50 FMCTs-600/1250-A 208.92

150 70 FMCTs-600/1250-B 212.18

- 95 FMCTs-600/1250-C 209.64

185 120 FMCTs-600/1250-D 212.18

240 150 FMCTs-600/1250-E 208.92

300 185 FMCTs-600/1250-G 209.64

- 240 FMCTs-600/1250-H 208.92

400 300 FMCTs-600/1250-J 214.76

500 400 FMCTs-600/1250-L 214.76

630 - FMCTs-600/1250-M 221.47

- 500 FMCTs-600/1250-N 222.15

- 630 FMCTs-600/1250-Q 221.47

Conductor Size

mm2 12kV

Conductor Size

mm2 24kVRef. No.

Price £each

SEPARABLE TEE CONNECTORS

TEE CONNECTORTo suit polymeric cables up to 24kV - non-loadbreak operation - rating 1250A (with clamping screw).

Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire) Conductor Type and size in mm2 : “A” (Aluminium) - mm2 "C" (Copper) - mm2

To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2

Note : Typical example for a 24kV tee connector for 300mm2, copper wirescreen cable aluminium conductor : FMCTs-600/1250-J-24-T3-A300

Separable ConnectorsA C C E S S O R I E S F O R 4 0 0 A T E E C O N N E C T O R S

Sec

tion

5 :Sepera

ble

Connecto

rs

All prices are subject to our Terms and Conditions of Sale - see inside front cover for more details Page 69Products with prices in BOLD are made to order and are subject to a minimum order quantity • All other items are normally exstock, subject to remaining unsold. Confirmation will be made at time of order

INSULATING PLUGExpoxy resin mould which provides dead-end facility for separable tee connectors.

Insulating Plug 12kV - rating 400A FMPI-400-12 29.23

Insulating Plug 24kV - rating 400A FMPI-400-24 29.23

Description Ref. No.Price £each

Stand Off Plug 12kV - rating 400A FMPS-400-12 121.60

Stand Off Plug 24kV - rating 400A FMPS-400-24 121.60

Description Ref. No.Price £each

STAND OFF PLUGEDPM moulding which is designed to proivde support and dead-end separable connector when removed from the equipment.

Straight Connection Plug 12kV - rating 400A FMPCs-400-12 141.20

Straight Connection Plug 24kV - rating 400A FMPCs-400-24 141.20

Description Ref. No.Price £each

STRAIGHT CONNECTION PLUGExpoxy resin moulding over a copper rod for connecting two separable tee connectors FMCTs-400.

Earthing Plug - rating 400A FMPE-400 228.33

Description Ref. No.Price £each

EARTHING PLUGEDPM moulding designed to support and earth separable connectors when removed from the equipment.

120 50 FMCTs-600/1250-A 208.92

150 70 FMCTs-600/1250-B 212.18

- 95 FMCTs-600/1250-C 209.64

185 120 FMCTs-600/1250-D 212.18

240 150 FMCTs-600/1250-E 208.92

300 185 FMCTs-600/1250-G 209.64

- 240 FMCTs-600/1250-H 208.92

400 300 FMCTs-600/1250-J 214.76

500 400 FMCTs-600/1250-L 214.76

630 - FMCTs-600/1250-M 221.47

- 500 FMCTs-600/1250-N 222.15

- 630 FMCTs-600/1250-Q 221.47

Conductor Size

mm2 12kV

Conductor Size

mm2 24kVRef. No.

Price £each

SEPARABLE TEE CONNECTORS

TEE CONNECTORTo suit polymeric cables up to 24kV - non-loadbreak operation - rating 1250A (with clamping screw).

Voltage Class : kVEarthing Kit : T1 (Polylam) T2 (Copper Tape) T3 (Copper Wire) Conductor Type and size in mm2 : “A” (Aluminium) - mm2 "C" (Copper) - mm2

To select - Ref. no + Voltage class + Earthing kit + Conductor type & size mm2

Note : Typical example for a 24kV tee connector for 300mm2, copper wirescreen cable aluminium conductor : FMCTs-600/1250-J-24-T3-A300

29www.prysmiancable.com.au | www.prysmiancable.co.nz

STAND-OFF PLUG – FMPS-400 / FMPSs-400

• EPDM moulding designed to support and dead-end separable connectors when removed from the equipment.

• The stand-off plug is equipped with a metallic bracket. The part in semi-conducting EPDM provides the electrical continuity with the outer envelope of the separable connector.

• Operated when de-energized.

• Packing: per piece.

EARTHING PLUG – FMPE-400 / FMPEs-400

• EPDM moulding designed to support and earth separable connectors when removed from the equipment

• The earthing-plug is equipped with a metallic bracket.

• Packing: per piece.

SEPARABLE CONNECTORS

SELECTION GUIDE – FMPS-400 / FMPSs-400

VoltageUm

Reference

Interface B Interface C

12 kV FMPS-400-12 FMPSs-400-12*

24 kV FMPS-400-24 FMPSs-400-24*

36 kV FMPS-400-36 FMPSs-400-36*

*Suffix "s" = screw type (for interface type C).

SELECTION GUIDE – FMPE-400 / FMPEs-400

Reference

Interface B Interface C

FMPE-400 FMPEs-400*

*Suffix "s" = screw type (for interface type C).

FT N

°345

Sep

arab

le S

trai

ght C

onne

ctor

FM

CS 4

00 -

V1 M

ay 2

018

Medium Voltage (MV)Up to 19/33 (36) kVMV Separable Connectors rating 400A (Interface B) Reference: FMCS-400

Separable straight connector FMCS-400(Interface B / 400A) For polymeric cables -Deadbreak - Operation Generally meets the requirement C 33-051 - HD 629.1.S2 - IEC 60502-4 Interface: CENELEC EN50180 - EN50181

Utilisation• For connection of polymeric MV cables to transformers, switchgear units,

motors, etc. • Indoor and outdoor installation. The connector is entirely protected by a

watertight conductive envelope connected to earth. • Continuous 400 A rms overload 600 A rms (8 hours per 24-hour period). • Dead break operation.• Voltage detection through an integrated capacitive voltage

divider.

Cables• Single core polymeric insulation (XLPE). • Copper or aluminum conductor. • Semi-conducting screen either extruded or taped. • Metallic screen of copper tape, copper wires or polylam type.• Insulation voltage up to 36 kV. • Conductor sizes: 25 mm2 to 300) mm2.

Packing Supplied as a kit of three single connectors containing all the necessary components. Shipping weight and volume (approx) of kit: 4,5 kg / 0,01 m3

Other products• Associated products such as bushing FMBOm-400 and accessories for separable connectors 400A,

interface B.

1/2

Product Application and Design

INTERFACEB / 400 A

®

Prysmian Group Sales department - mail : [email protected]

A mark of

Installation features• No need for special tools, no heating, taping or filling. • Vertical, angled or inverted position. • No minimum distance between phases. • Energizing may take place immediately after the connector is plugged on its mating bushing, dead-end

plug... • Individual clamping by stainless steel brace.• An unplugged connector must never be energized

TEST ROD – FMTR-400

• For testing or earthing of cables equipped with separable tee connectors.

• Screwed onto threaded part of contact pin or on clamping screw of tee connectors.

• Packing: per piece.

SELECTION GUIDE – FMTR-400

VoltageUm

Reference

12 and 24 kV FMTR-400

Page 30: Creating life long relationships

30 www.prysmiancable.com.au | www.prysmiancable.co.nz

INTERFACE FOR SEPARABLE CONNECTORS

According to CENELEC EN 50180 & EN 50181 Prysmian specific

Type: A B2 C1 D1 / D2 E1 / E2 Z

Drawings:

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

A mark of

FT N

°334

Inte

rfac

es fo

r sep

arab

le c

onne

ctor

s -

May

201

8

Medium Voltage (MV)Up to 36 kV

R E A C H

Interfaces for separable connectors

1/1

According CENELEC* EN 50180 et EN 50181

Type A B2 C1 D1/D2 E1/E2Z

(Propre à PRYSMIAN)

Drawings

Insulator voltage 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1Bore

Ø 7,9 mm, Depth:32 mm

BoreØ 14 mm,

Depth: 40 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

Thread M16, Depth: 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39,9 mm Ø 39,9 mm Ø 49,9 mm

D3 Ø 32,5 mm Ø 56 mm Ø 56 mm Ø 52,1 mm Ø 61,5 mm Ø 56 mm

D4 Ø 48,5 mm Ø 70 mm Ø 70 mm Ø 76,2 mm Ø 76,2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103,7 mm 55 mm

Utilisation250 ASliding contact12 & 24 kV

400 ASliding contact12,24&36kV

630 ABolted contact12,24 & 36 kV

1250 ABolted contact12 & 24 kV

1250 ABolted contact36 kV

630 ABolted contact12,24 & 36 kVSpecial interface

Remarks Same dimensions as interface C

Same dimen-sions as Inter-face B

N.A in Prysmian product range

Profile identical to the interface C, but shortened (the angle is the same)

* Except for Interface Z which is a Prysmian specific size

Prysmian Group Sales department - mail : [email protected]

© PRYSMIAN 2018. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.

Insulator voltage: 24 kV 36 kV 36 kV 24 kV 36 kV 36 kV

Continuous current: 250 A 400 A 630 A 1 250 A 1 250 A 630 A

D1 Bore: Ø 7.9 mm, depth 32 mm

Bore: Ø 14 mm, depth 40 mm

Thread: M16, depth 29 mm

Thread: M16, depth 29 mm

Thread: M16, depth 29 mm

Thread: M16, depth 29 mm

D2 Ø 31 mm Ø 46 mm Ø 46 mm Ø 39.9 mm Ø 39.9 mm Ø 49.9 mm

D3 Ø 32.5 mm Ø 56 mm Ø 56 mm Ø 52.1 mm Ø 61.5 mm Ø 56 mm

D4 Ø 48.5 mm Ø 70 mm Ø 70 mm Ø 76.2 mm Ø 76.2 mm Ø 70 mm

L1 48 mm 90 mm 90 mm 81 mm 103.7 mm 55 mm

Utilisation:250 A Sliding contact 12 & 24 kV

400 A Sliding contact 12, 24 & 36 kV

630 A Bolted contact 12, 24 & 36 kV

1 250 A Bolted contact 12 & 24 kV

1 250 A Bolted contact 36 kV

630 A Bolted contact 12, 24 & 36 kV Special interface

Remarks: –Same dimensions as interface C.

Same dimensions as Interface B.

– N.A in Prysmianproduct range.

Profile identical to the interface C, but shortened (the angle is the same).

Description

Interfaces for separable connectors. Medium voltage (MV). Up to 36 kV.

INTERFACES

SEPARABLE CONNECTORS

Page 31: Creating life long relationships

31www.prysmiancable.com.au | www.prysmiancable.co.nz

Page 32: Creating life long relationships

© A

ll rights reserved by Prysmian Group 20

18-11 | V.2

Prysmian Australia Pty Ltd

1 Heathcote Road, Liverpool 2170 NSW, Australia Ph: 1300 300 304 Fx: 1300 300 307 E-mail: [email protected] www.prysmiancable.com.au

Prysmian New Zealand Ltd

30 Binsted Road, New Lynn 0600 Auckland, New Zealand Ph: (09) 827 3109 Toll Free: 0800 492 225 E-mail: [email protected] www.prysmiancable.co.nz

Connect with us

Prysmian Australia & New Zealand

Prysmian Group

Linking the future