Page 1: AIR COOLED MINI CHILLER - Acson · PDF fileexpansion system. Mini chiller is more eco ... the length of the piping. This allows more flexibility in system design and ... Amp Amp M

AIR COOLEDMINI

CHILLER

AP/AMAC01703ISO 9002

REGISTERED

Page 2: AIR COOLED MINI CHILLER - Acson · PDF fileexpansion system. Mini chiller is more eco ... the length of the piping. This allows more flexibility in system design and ... Amp Amp M

The mini chiller is a new innovation in air conditioning technology. It is an alternative for large chiller system or multi split direct expansion system. Mini chiller is more eco friendly as only a small quantity of refrigerant is needed and refrigerant is pre-charged in the factory using sophisticated charging machine under strict quality control. Thus eliminate refrigerant charging in the field at the same time ensuring safety and reliability.

Acson mini chiller is equipped with intelligently designed safety control to ensure continuous safety operation. The refrigerant is confined in the outdoor condensing unit making it safe and hazard-free for the inhabitant.

Eco Friendly And Safety

The mini chiller is ideal for office, shopping complexes, hotels, etc which required zone control or individual cooling operation as the fan coil unit can be controlled separately.

Zone Control

F e a t u r e s • • •

Maximum Flexibility

Safety Control

The mini chiller is complete with intelligent micro processor controller to provide accurate temperature control and system safety protection. The controller also provides simple self diagnosis to simplify trouble shooting process.

Mini chiller can be installed anywhere and even far away from the fan coil units allowing maximum flexibility for site installation. It can be placed anywhere in a building to suit individual building design and requirement.

There is no pipe length limitation as water pump can be changed to accommodate

the length of the piping. This allows more flexibility in system design and

installation.

F e a t u r e s • • •

Page 3: AIR COOLED MINI CHILLER - Acson · PDF fileexpansion system. Mini chiller is more eco ... the length of the piping. This allows more flexibility in system design and ... Amp Amp M

The light weight condenser and fan coil units are designed for ease of installation. The condenser unit is compact and light, enable easy handling and transportation.

The standard water circuit kit which consist of water pump; heat insulated water storage tank; brazed plate heat exchanger; controls is designed and sized to reduce the design and installation time.

Installation Friendly

Capacity Versatility

Acson mini chiller can be couple with different types of fan coil units. This allows maximum flexibility for interior design.

Page 4: AIR COOLED MINI CHILLER - Acson · PDF fileexpansion system. Mini chiller is more eco ... the length of the piping. This allows more flexibility in system design and ... Amp Amp M

HEAT PUMP MODELS

36540

42490

145000

31500

36630125000

AMAC040AR AMAC050AR AMAC058AR AMAC075BR AMAC100BR AMAC125BR

COOLI NG ONLY MODELS AMAC040A AMAC050A AMAC058A AMAC075B AMAC100B AMAC125B

NOMI NAL COOLI NG CAPACI TY

NOMI NAL HEATI NG CAPACI TY

kcal/h

kcal/h

W

W

Btu/hr

Btu/hr

7560

8790

30000

8060

9380

32000

10840

12600

43000

12600

14650

50000

23440

27250

93000

25200

29300

100000

10080

11720

40000

12100

14060

48000

20160

23440

80000

23690

27540

94000

31500

36630NOMI NAL COOLI NG CAPACI TY

CASI NG

TOTAL UNI T DI MENSI ON

PUMP

PI PI NG

TANK

TOTAL WEI GHTNOI SE LEVEL

TYPEWATER VOLUME

NOMI NAL WATER FLOW

EVAPORATOR

WATER LI NE ( HYDRAULI C KI T)

CONDENSER COI L

CONDENSER FAN

COMPRESSOR

REFRI GERANT

MATERI ALFI NI SHTHI CKNESSHEI GHT (H)WI DTH (W)DEPTH (D)

TYPE

POWER SUPPLY

RUNNI NG CURRENT

WATER FLOW RATE

I NSTALLATI ON PI PE CONNECTI ON

HEAD

MATERI AL

CAPACI TY/VOLUME

kcal/hW

Btu/hr

mmmm(in)mm(in)mm(in)

m3

l/s

V/Ph/Hz

Amp

GPM (l/s)

mm(in)

m

litres

kg

dBA

7560

8790

10080

11720

11342(52.8)1032(40.6)558(22.0)

12600

14650

ELECTRO-GALVANI SED MI LD STEEL

POLYESTER POWDER

STAI NLESS STEEL BRAZED PLATE HEAT EXCHANGER

HORI ZONTAL MULTI STAGE END-SUCTI ON

380-415/3/50

42mm BSP (11/4")

BLACK MI LD STEEL

CROSS FI NNED TUBESSEAMLESS COPPER

0.35(0.014)

9.52(3/8)

ALUMI NI UM

0.127(0.0005)

PROPELLER/DI RECT

380-415/3/50

OVERLOAD PROTECTI ON, FLOW SWI TCH AND H/L PRESSURE SWI TCHON/OFF

R22

THERMOSTATI C EXPANSI ON VALVE

FLARE VALVE FI TTI NGS

2

20160

23440

25200

2930012500030000 40000 50000 80000 100000

380150 155 160 350 3507458 58 71 65 65

0.0030.00075 0.001 0.0014 0.00143 0.00191.750.42 0.56 0.70 1.12 1.40

1.51.02 1.02 1.05 1.5 1.5

18

762(30)

24

14

22

32

0.87(9.36)

ACRYL STYRENE RESI N609.6(24)

99/3500

RECI PROCATI NG

220-240/1/50

20 27

16

23

150

2.95(31.75)

ALUMI NI UM

660.4(26)

380-415/3/50

27.75(1.751)6.66(0.421) 8.89(0.561) 11.10(0.7) 17.78(1.122) 22.22(1.402)

7.403.10 3.00 2.90 5.50 5.50

8.602.10 2.38 2.50 7.90 7.90

23.05.34 7.11 8.29 14.7 15.322.0/23.35.52/5.62 7.50/7.24 7.90/8.20 15.6/15.7 17.5/17.2

132202983 4343 4681 7700 901012832/138823212/3187 4373/4084 4341/4656 8200/8500 9410/9174

19845

9.52(3/8) 12.7(1/2)

62

19.05(3/4)

74 125 167

NI LNI L NI L

NI LNI L NI L

68 8 6 6 63.61.09 1.09 1.8 1.4 1.4

1250145 145 400 588 5881978

297/10500241 241 420

127/4500

640

176/6200

SCROLL

640

1.5

1739(68.5)1089(42.9)1288(50.7)

TYPE

TUBE

FI N

FACE AREA

TYPE/DRI VE

TYPE

POWER SUPPLYRATED RUNNI NG CURRENT-COOLI NG ONLY

RATED I NPUT-COOLI NG ONLYRATED I NPUT-HEATI NG PUMP (COOLI NG/HEATI NG)

BLADE MATERI AL

BLADE DI AMETERPOWER SUPPLY

MOTOR POLE

RATED RUNNI NG CURRENT

MATERI AL

THI CKNESS

OUTER DI AMETER

MATERI AL

THI CKNESS

ROWS

FI N PER I NCH

DI SCHARGE

SUCTI ON

COOLI NG ONLY

HEAT PUMP

mm(in)

mm(in)

mm(in)

mm(in)

mm(in)

mm(in)

kg

kg

V/Ph/Hz

V/Ph/Hz

Amp

Amp

MAX STARTI NG CURRENTPROTECTI ON DEVI CESTAGE OF CAPACI TY CONTROL

TYPE

CONTROL

REFRI GERANT PI PE CONNECTI ON

PI PE SI ZE

CHARGI NG MASS

Amp

RATED RUNNI NG CURRENT-HEAT PUMP (COOLI NG/HEATI NG) Amp

RATED OUTPUTRATED I NPUT

WattWatt

WattWatt

AI R VOLUME cmm/cfm

m2(ft2)

S P E C I F I C AT I ON S

1. ALL SPECI FI CATI ONS ARE SUBJECT TO CHANGE BY MANUFACTURER WI THOUT PRI OR NOTI CE.2. NOMI NAL VALUES ARE BASED ON ENTERI NG/LEAVI NG CHI LLED WATER TEMPERATURE 12 C̊/7 C̊ AND AI R AMBI ENT TEMPERATURE 35 C̊.3. NOMI NAL VALUES ARE BASED ON ENTERI NG/LEAVI NG HOT WATER TEMPERATURE 40 C̊/45 C̊ AND AI R AMBI ENT TEMPERATURE 7 C̊.

Head Office:Jalan Pengapit 15/19, P.O.Box 7072, 40702 Shah Alam, Selangor Darul Ehsan, Malaysia - Tel: (603) 55194922 - Fax: (603) 55106980, 55101567 - www.acson-international.comEurope Office:C/O J&E Hall Limited, 40-41 Questor Estate, Pearson Way, Dartford, DA1 1JN, United Kingdom - Tel: +44 1322 428085 - Fax: +44 1322 428086Americas:C/O McQuay Latin America L. C., 7205 N.W., 19st, suite 408, Miami, Florida 33126, USA - Tel: +1 - 305 - 7168631 - Fax: +1 - 305 - 7161148 Middle East:C/O AAF McQuay L.L.C, P.O.Box 28564, Dubai, U.A.E. - Tel: (9714) 3388545 - Fax: (9714) 3391009