1 Xtralis VESDA VFT-15 Sales and Technical Sales and Technical Presentation Extending the VESDA Range The Xtralis VESDA VFT-15 is a unique and versatile high sensitivity ASD that can pinpoint the source of an incipient smoke incident Minimises business disruption and downtime Speeds response Enhances investigation Two variants are available – VFT-15 (0.01 – 20% Obs/m or 0.003 – 6.10% Obs/ft) – VFT-15-C (1 – 20% Obs/m or 0.3 – 6.10% Obs/ft) VESDA VFT-15 Value Proposition The only ASD product available on today’s market to provide: Pinpoint location of the source and location of an incipient smoke incident, therefore minimising investigation and downtime Intelligent addressability to identify up 15 protected areas respectively via microbore air sampling tubes respectively , via microbore air sampling tubes High sensitivity ranging from 0.01 to 20 % obs/m (0.003 – 6.10% obs/ft) Optional CO gas sensor The VFT-15 is complementary to the existing range and provides pinpoint addressability at a more compelling price than multiple VLS units with single hole pipes.

Upload: arith-krishnanandan

Post on 14-Apr-2015

35 views

Category:

Documents


2 download

DESCRIPTION

control system of alarm

TRANSCRIPT

Page 1: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

1

Xtralis VESDA VFT-15Sales and TechnicalSales and Technical Presentation

Extending the VESDA Range

The Xtralis VESDA VFT-15 is a unique and versatile high sensitivity ASD that can pinpoint the source of an incipient smoke incident

– Minimises business disruption and downtime

– Speeds response

– Enhances investigation

Two variants are available

– VFT-15 (0.01 – 20% Obs/m or 0.003 – 6.10% Obs/ft)

– VFT-15-C(1 – 20% Obs/m or 0.3 – 6.10% Obs/ft)

VESDA VFT-15 Value Proposition

The only ASD product available on today’s market to provide:

Pinpoint location of the source and location of an incipient smoke incident, therefore minimising investigation and downtime

Intelligent addressability to identify up 15 protected areas respectively via microbore air sampling tubesrespectively, via microbore air sampling tubes

High sensitivity ranging from 0.01 to 20 % obs/m (0.003 –6.10% obs/ft)

Optional CO gas sensor

The VFT-15 is complementary to the existing range and provides pinpoint addressability at a more compelling price than multiple VLS units with single hole pipes.

Page 2: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

2

Product Positioning

Area

Sensitivity

400m2 800m2 1200m2 1600m2 2000m2

High

(EN54-20 Class A)

VFT-15

(VEW)

Enhanced

(EN54-20 Class B)

(EW)

Normal

(EN54-20 Class C)

VLPVLS

VLF250

VLF500

VLC

VFT-15-C

Matching Models With EnvironmentsEnvironment VLP VLS VLC VLF VFT-15

Aircraft Hangars x xAtria xAuditorium xCable Tunnels/Trays x x xCasinos x xClean Rooms x x x x xCold Rooms x xComputer Rooms x x x x xControl Rooms x x x x xDormitories x x xEDP Environments x x x x xElect/Switching Cabinets x x xElect/Switching Cabinets x x xEquipment Cabinets x x xHistorical Buildings x x x x xHospitals x x x x xHotels x x x x xLaboratories x x x x xLibraries/Archival Storage x x x xManufacturing Facilities x xMuseums/Art Galleries x x xOffices x x x xPrison cells x x x xSchools x xStorage Areas x x xSubstations x x xTelecommunications x x x x xTheatres x x

Transportation x x x

Site conditions and pipe network design will determine the final choice of detector.

Principle of Operation

Actively draws air from the protected area through a network of flexible pipes

Filters and conditions the air where necessary

Analyses the air for low levels of smoke

Id tifi th i hi h th Identifies the pipe on which the incident occurred

Sets alarms on four programmable thresholds

Reports the alarm via relay outputs or communication network

Page 3: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

3

Detection Principle VFT

Sensitivity from 0.01% - 20% obs/m (0.003 – 6.10% obs/ft) for VFT-15 or 1% -20% obs/m (0.3 – 6.10% obs/ft) for VFT-15-C

A laser illuminates smoke particles in an optical chamber with 360 degree lightoptical chamber with 360 degree light guide collector

Unique field serviceable optical chamber separates optics from sampled air

Removable chamber includes particle filter

6 mm micro bore air sampling High or normal sensitivity laser

detection 15 pipes 50 m pipe length each pipe 4 Alarms - Alert, Action, Fire 1, Fire 2 Powerful suction rotary vane vacuum

0 7 B ith iti i fl

VFT- 15 Micro Bore 15 Pipe Detector

pump – 0.7 Bar with sensitive airflow monitor

Large, clear display panel Onboard Modbus RS232 and RS485 TCP/IP Ethernet Modular relay output units PSU, battery charger and battery

optional

What’s inside VFT-15?

15 Sector inputs

Display/

Programmer

0.7 Bar Vacuum pump

Battery Compartment

Power Supply (if required)

I/O modules when the display is lowered

Page 4: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

4

Sampling Components

Powerful 0.7 Bar suction rotary vane vacuum pump.

15 way rotary valve incorporating pressure sensor.– Trace mode of operation: samples overall from all pipes

• 30 sec to detection

– Selection mode: Scans sectors when smoke detected

• +/ 9 sec/pipe• +/- 9 sec/pipe

– Self test mode: every 20 min

• 1/1 dilution (no dilution of smoke sample)

VFT-15 Microbore Sampling

The VFT-15 requires microbore, which is 6 mm OD and 4mm ID flexible nylon tube.

All lengths should be equal with a maximum allowable length of 50 m per tube.

Other materials may be used such as Stainless Steel with suitable adaptors for harsh environments.

Never glue to the inlets of the detector.

Unused inputs should be looped to one another using short lengths of microbore.

VFT-15 - Accessories

Part Number Description

VFT-15 Xtralis VESDA VFT‐15, 24v DC with Display & TCP/IP

VFT-15-C Xtralis VESDA VFT‐15, 24v DC with Display & TCP/IP ‐ Class C Sensitivity

01-E921-15 Remote Display

01-EP02-02 Mains PSU/Battery Charger 230VAC  

01-E606-01 Relay Module 4 Channel FT series

01-E624 Re‐Transmission Module 8 Channel 4‐20mA

01-E922-01 Mini RDU RS485 ‐ 19" rack mount

Page 5: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

5

Power Supply

Optional 230V AC supply and battery charger (EN54)

2 x 12V (18 AH) batteries inside housing or 2 x 12 V (40 AH) batteries outside the housing

I/O Modules

Optional I/O modules

– 4 Channel relays

– 8 Channel 4-20 mA Analogue Out

VFT Series Display Panel

Display may be used to program the detector

Page 6: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

6

Remote Display Options

Remote Display Panel– Remote display & keypad

– One per detector up to 1km away

– RS485 connected.

Rack Mounted Remote Display Unit– 19” rack mount - 12 per rack

– Accept / reset / isolate

– Bar graph, alarms and faults

– RS485 connected via CN6 on i602 board (Termination Board)

– Up to 16 per detector– Up to 16 per detector

VSC Configuration andcontrol of all Xtralis VESDAdevices

Sophisticated but intuitive support tools

Supporting Software

VSM4 Remote monitoringand control of multipledevice networks in fullgraphical context, includingemail/SMS messaging andfire policy prompts

Remote Access & Networking

Page 7: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

7

Typical VFT-15 Applications

Electronic data processing equipment

High sensitivity

Micro bore pipes forMicro bore pipes for individual cabinet identification

Unaffected by high air speeds

Optional integral hydrogen monitoring of UPS rooms

A highly addressable solution for fully-enclosed cabinets

Extending the VLP-VLS solution

Typically a VLP would be used to protect the open environment of the modern high density data centre.

Addressability to a particular area might be possible by using a VLS pipe per isle or per grille but this can be economically challenging

Extending the VLP/VLS solution

The application of VFT-15 provides fully addressable coverage of the mission critical cabinets while the VLP detects less critical environments such as across the return air grille and hot isles.

Page 8: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

8

Typical VFT-15 Applications

Mines and Electrical Substations

Operates in dusty environments

Individual protection of high-voltage switchgear cabinetsvoltage switchgear cabinets

HV cabinets are bolted and cannot be opened easily

PLC and control rooms

Electrical substations

Extending the VLP-VLS solution

The current solution for protecting low heat load vented cabinets is to sample at the top of the cabinet using capillary tubes placed into the various cabinets from a main branch pipe.

The disadvantage is that only aThe disadvantage is that only a global alarm will be generated, requiring visual inspection of each cabinet to determine the source

Use of a VLS provides enhanced addressability per main branch pipe but still does not provide individual cabinet identification

Extending the VLP-VLS solution

The VFT-15 offers an extremely competitive and more elegant solution for identifying up to 15 individual cabinets.

Page 9: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

9

Typical VFT-15-C Applications

Prisons and Correctional Institutions

Tamper proof air sampling

Individual monitoring of up to 15 cells

High speed reaction time High speed reaction time

Central maintenance facility

Typical VFT-15-C Applications

Exclusive Residences, Shops & Apartments

Aesthetic, invisible

Unique low profile stainlessUnique low profile stainless steel sampling point!

– Only Ø 33 mm x 4 mm height

Programming Tools

VSC/VSM4

VFT Display Panel

Page 10: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

10

Programming with VFT Display

Programming Keys

Log on to the DetectorUsing the Admin Code 693

1. Alert 0.08%2. Action 0.14%3. Fire 1 0.2%4. Fire 2 1.5%

5. Set the fan speed to 76. Normalize the Detector7. Set the High Flow to 135%8. Set the low flow to 75%

Menus Available1. Faults2. Operator3. Engineering4. Configure5. Sector Alarms6. Time + Date7. Web8. Setup9. Laser Cal10. Load Defaults11. Maintenance12. Test Outputs

Basic Programming Exercise

VFT RS485 Communications

Three Options:

– Up to 30 Detectors communicate to a PC

– 1 Detector communicates with one Remote Display Panel

– Up to 16 Detectors communicate 16 R t Di l U itRemote Display Units

Cannot combine any of the three options.

VFT RS485 Communications

Connect shielded twisted pair to CN6

Ensure length doesn’t exceed 1km

CN6 CN6 CN6 CN6

Set Jumper to “End” for End of Line Detectors

Page 11: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

11

VFT RS485 Communications

Connect a Remote Display Panel using connector under the Display Panel.

Ensure length doesn’t exceed 1km

Note: The configuration of the detector needs to be changed to expect the Remote Display Panel.

VFT Relays

On-board Relays Relay Modules

VFT Relay Assignments

Page 12: 16200_00_VFT-15_Sales and Technical Presentation [Compatibility Mode].pdf

12

VFT Faults

General Fault

Mains Fault

Flow Fault

Battery Fault y

Aspirator Fault

Detector Fault

Comms Fault

If faults not rectified on site when referring to trouble shooting guide contact Xtralis

VFT Spare Parts List

Part Number DescriptionVFT-15 Xtralis VESDA VFT‐15, 24v DC with Display & TCP/IP

VFT-15-C Xtralis VESDA VFT‐15, 24v DC with Display & TCP/IP ‐ Class C Sensitivity

01-E921-15 Remote Display

01-EP02-02 Mains PSU/Battery Charger 230VAC  

01-E606-01 Relay Module 4 Channel

01-E624 Re‐Transmission Module 8 Channel 4‐20mA , FT series

01-E922-01 Mini RDU RS485 ‐ 19" rack mount

01-E922-99 19” sub rack for 12 Mini RDU 

01-E922-00 Blind plate for sub rack

02-2001-30 Micro Bore 6mm sampling tube ‐ 30m reel  

02-2002-01P Straight Union for Micro Bore 6mm Tube  (Pack of 10) 

02-2003-01P Tee Union for Micro Bore 6mm Tube  (Pack of 10) 

02-3000-06 Stainless steel sampling point 6mm

02-FL01-01 Scintered EOL Filter for Micro Bore 6mm Tube  

End of presentation