- instrumentation cables

3
For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected] This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA Grey, Black or Light blue Colors Fire retardant thermoplastic compound R16 PVC-based H.R. and O.R. suitable for CPR (R16 quality) Material SHEATH 70 °C Max operating temperature 160 °C Max short circuit temperature 10 x Diam. Min. bending radius Mechanical and Installation: Electrical: >= 100 MOhm x km Insulation resistance 3000 V a.c. x 10 min Dielectric test cond/cond 450/750 V Voltage rating CHARACTERISTICS Cores are twisted in pair with optimal lay length Type PRIMARY CABLING Al/polyester tap, Al in continuos contact with stranded tinned copper cl.2 Material TOTAL SCREEN Pairs are cabled together with optimal lay length Type TOTAL CABLING On Request Colors Fire retardant thermoplastic compound S17 PVC-based (S17 quality) Material INSULATION Flexible annealed bare copper cl.5 Material CONDUCTOR CABLE CONSTRUCTION AND SPECIFICATIONS IDENTIFICATION AND REACTION TO FIRE FS17XOHR16 - 450/750 V - PAIR Cca-s3,d1,a3 DRAWING IS ONLY ILLUSTRATIVE CPR cable - INSTRUMENTATION CABLES FORELIND ® Special Electrical Cables

Upload: others

Post on 01-Oct-2021

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: - INSTRUMENTATION CABLES

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

Grey, Black or Light blueColors

Fire retardant thermoplastic compound R16 PVC-based H.R. and O.R. suitable for CPR (R16 quality)

MaterialSHEATH

70 °CMax operating temperature

160 °CMax short circuit temperature

10 x Diam.Min. bending radiusMechanical and Installation:

Electrical:

>= 100 MOhm x kmInsulation resistance

3000 V a.c. x 10 minDielectric test cond/cond

450/750 VVoltage rating

CHARACTERISTICS

Cores are twisted in pair with optimal lay lengthTypePRIMARY CABLING

Al/polyester tap, Al in continuos contact with stranded tinned copper cl.2 MaterialTOTAL SCREEN

Pairs are cabled together with optimal lay lengthTypeTOTAL CABLING

On RequestColors

Fire retardant thermoplastic compound S17 PVC-based (S17 quality)MaterialINSULATION

Flexible annealed bare copper cl.5MaterialCONDUCTOR

CABLE CONSTRUCTION AND SPECIFICATIONS

IDENTIFICATION AND REACTION TO FIRE

FS17XOHR16 - 450/750 V - PAIR Cca-s3,d1,a3

DRAWING IS ONLY ILLUSTRATIVE

CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

Page 2: - INSTRUMENTATION CABLES

For.El.Ind. SpA reserve the right to modify product characteristics at any time without notice, based on its commercial needs. It is forbidden to sell and publish this data sheet without written authorization by For.El.Ind. SpA

FOR.EL.IND S.p.A. - Via Europa, 6 - 24055 Cologno al Serio (BG) ITALY - Phone +39 035 899191 - Fax +39 035 4819224 - www.forelind.com - E-mail: [email protected]

This is a part of our products range. For any technical information or change of cable type do not hesitate to contact our sales department. Issued: DT // Approved: QA

8000

8001

8004

8006

8008

8018

8019

8022

8024

8026

8027

8028

8031

8033

8035

78

157

288

500

903

104

217

415

758

1382

145

319630

1158

2151

7,33

10,53

14,26

18,71

25,67

8,19

11,94

16,33

21,79

29,96

8,53

14,3419,74

26,45

36,76

-

-

-

-

-

-

--

-

-

-

--

--

-

26

26

26

26

26

13,3

13,3

13,3

13,3

13,3

7,98

7,987,98

7,98

7,98

FS17XOHR16 - 450/750 V - 1X2x0,75 mm2

FS17XOHR16 - 450/750 V - 2X2x0,75 mm2

FS17XOHR16 - 450/750 V - 6X2x0,75 mm2

FS17XOHR16 - 450/750 V - 12X2x0,75 mm2

FS17XOHR16 - 450/750 V - 24X2x0,75 mm2

FS17XOHR16 - 450/750 V - 1X2x1,5 mm2

FS17XOHR16 - 450/750 V - 2X2x1,5 mm2

FS17XOHR16 - 450/750 V - 6X2x1,5 mm2

FS17XOHR16 - 450/750 V - 12X2x1,5 mm2

FS17XOHR16 - 450/750 V - 24X2x1,5 mm2

FS17XOHR16 - 450/750 V - 1X2x2,5 mm2

FS17XOHR16 - 450/750 V - 2X2x2,5 mm2FS17XOHR16 - 450/750 V - 6X2x2,5 mm2

FS17XOHR16 - 450/750 V - 12X2x2,5 mm2

FS17XOHR16 - 450/750 V - 24X2x2,5 mm2

Ohm/km mm mm kg/km

Max conductorresistance at 20°C

Nom. Underarmour Ø

Nom. Outer Ø Nom. Weight P/NIDENTIFICATION ( * )

CEI 20-11/0-1;V1 - -Insulating, sheathing and covering materials for low-voltage energy cables (CPR)

CEI 46-143 - EN 50288-7(CEI EN 50288-7)

Multi-element metallic cables used in analogue and digital communication and control. Part 7: Sectional specification for instrumentation and control cables (where applicable)

CEI 20-29 IEC 60228 EN 60228(CEI EN 60228)

Conductors of insulated cables

STANDARDS OR SPECIFICATIONS CONSTRUCTION

CEI 20-35/1-2 IEC 60332-1-2 EN 60332-1-2(CEI EN 60332-1-2)

Test on electric and optical fibre under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

CEI 20-108 - EN 50399(CEI EN 50399)

Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results

STANDARDS OR SPECIFICATIONS TEST

DATASHEET

PAGE 02CPR cable - INSTRUMENTATION CABLES

FORELIND®

Special Electrical Cables

( * ) Any other identification on request. Please contact our technical department

Page 3: - INSTRUMENTATION CABLES

Via Europa, 6 - 24055 Cologno al Serio (BG - ITALY)Phone + 39 035 899191 - Fax + 39 035 4819224www.forelind.com E-mail: [email protected]

FOR.EL.IND S.p.A.

Special Electrical Cables