UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES

www.2mkablo.com1

Instrumentation Cables

IntroductionSpecialty Cables

300V & 600V Instrumentation Cable TypesCertificates and Standards300V Applications and Description300V 105°C PVC Insulated, Unshielded Pairs ITC/PLTC300V 105°C PVC Insulated, Unshielded Triads ITC/PLTC300V 105°C PVC Insulated, Unshielded Pairs with Overall Shield ITC/PLTC300V 105°C PVC Insulated, Unshielded Triads with Overall Shield ITC/PLTC300V 105°C PVC Insulated, Individual Pairs with Overall Shield ITC/PLTC300V 105°C PVC Insulated, Individual Triads with Overall Shield ITC/PLTC600V Applications and Description600V PVC/Nylon/PVC Overall Shielded Pairs/Triads TC-ER Rated600V PVC/Nylon/PVC Individual and Overall Shielded Pairs TC-ER RatedNotice

::

::::::::::::

2 - 34

678 - 910 - 1213 - 1516 - 1819 - 2122 - 242728 - 2930 - 3134

INDEX

www.2mkablo.com 2

2M CABLE CO. INC. Founded in 1993, 2M CABLE is a high-technology cable manufacturer specializing in all types of Low Voltage cables. The company is headquartered in Istanbul, Turkey and operates in a 270.000 ft2 area. Our Sales office and a warehouse in Moscow/Russia has succesfully been active since year 2005.

2M CABLE has been a reliable manufacturer and supplier to the sectors such as; Construction (High rise, intelligent&semiintelligent buildings, hospitals, universities, residence projects, etc.), Oil & Gas, Petrochemical, Power Plant Projects,Automation, Fire & Security, Satellite, Broadcasting, Audio-Video … We export to more than 50 countries worldwide (Mostly to Europe, MEA Countries, CIS Countries and South East Asia).

Introduction

www.2mkablo.com3

Instrumentation Cables

2M CABLE manufactures instrumentation cable mostly for refineries and petrochemical plants. Our Engineering and Designing team have knowledge of supporting cable needs for large projects in USA, Europe, Middle East, South East Asia, South America and Far East.

TRAY CABLES Tray cable, made for Control and Signaling Systems (*NEC Article 336) are used in petrochemical refineries, industrial control systems, intercom systems, traffic controls relay, power extensions. The cable is recognized for use in Class 1 and 2, Division 2, hazardous locations and for installation in trays, wire ways, troughs, ducts, conduit and channels.

ITC/PLTC CABLESITC/PLTC Cables have a wide range of application in process control and data processes, in analogue and digital signal transmission and power limited circuits. Factories, burglar alarms, business machines, refineries, petrochemical plants, intercom systems, industrial control systems, power plants, natural gas filling plants and etc. make up the general areas that these cables are used.

internacional
Texto tecleado
INARI ELECTRICS Madrid. Spain

We are also capable of designingand manufacturing tailor madecables customized according to your specificneeds and as peryour requirements of application.Many types of cables are availableat your request.

Specialty Cables

www.2mkablo.com

300V & 600VINSTRUMENTATION CABLE TYPES

Instrumentation Cables

www.2mkablo.com

www.2mkablo.com

2M CABLE UL 300V Instrumentation Cable Meets All Applicable SpecificationsUL 13UL 2250UL 1685NEC Type PLTC per Article 725NEC Type ITC per Article 727

For International Projects, the quality certificates we have & the standards we follow; Certificates LPCBVDERINA

StandardsIECBSENGOSTTSE

300V Instrumentation Cables

www.2mkablo.com7

300V Instrumentation Cables

300V, PVC Insulated, 105°CType PLTC – UL 13 – NEC ART 725Type ITC – UL 2250 – NEC ART 727

ApplicationsSoft annealed bare or tinned copper conductors and PVC flame retardant insulations and jackets are the standard for 300V instrumentation installation. Constructions with PVC/PVC that have three or more conductors and 20 AWG or larger conductors may also be used for direct burial installations.

Construction

ConductorBare, Tin-Coated, annealed copper, in solid, 7-strand, or 19-strand configurations from 20 AWG to 12 AWG.

InsulationPolyvinyl chloride in accordance with UL 13 and UL 2250, flame retardant, 105°C temperature rating.

Insulation Shield (on shielded pair/triad constructions):2M Cable provides many options for shielding to prevent EMI (electro-magnetic interference) within the twisted pairs, triads and for the overall cable using Overall Foil Shield, Aluminum/Polyester Foil and Aliminum Foil.

JacketUL listed sunlight and moisture resistant, black, flame retardant polyvinyl chloride material.

Features• UL approved Type PLTC and ITC, 300V• UL approved insulated conductors• Cables pass UL 1685 and IEEE 383 vertical fire tests at 70,000 BTU/hr• Temperature rating 105°C• Sunlight and moisture resistant jacket• UL 13 and 2250: The overall jackets of these cables are a “gas/vapour tight continuous sheath”• in Class 2 and Class 3 Circuits, as defined in NEC ART 725 for Type PLTC cables.

www.2mkablo.com 8

300V Instrumentation Cables

300V 105°CPVC Insulated Unshielded Pairs ITC/PLTC

Construction

Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8) Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer) Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C) colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250

Technical and Electrical Properties (20 °C)

Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests

Oil Resistance

:: :: : : ::::

:

300 VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft) 6.95 Ω/kft 10.92 Ω/kft20.08 14.97 14.97 11.82100.1 at 15.6°C fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)

www.2mkablo.com9

300V Instrumentation Cables

12461012182450

12461012182450

12461012182450

12461012182450

*14/7

*16/7

*18/7

*20/7

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0200.0200.0200.0200.0200.0200.0200.0200.020

0.0150.0150.0150.0150.0150.0150.0150.0150.015

0.0150.0150.0150.0150.0150.0150.0150.0150.015

0.0120.0120.0120.0120.0120.0120.0120.0120.012

0.510.510.510.510.510.510.510.510.51

0.380.380.380.380.380.380.380.380.38

0.380.380.380.380.380.380.380.380.38

0.30.30.30.30.30.30.30.30.3

0.0400.0500.0600.0600.0700.0700.0800.0800.090

0.0350.0500.0500.0600.0600.0700.0700.0800.090

0.0350.0500.0500.0500.0600.0600.0700.0700.080

0.0350.0400.0500.0500.0600.0600.0600.0700.070

1.021.271.521.521.781.782.032.032.29

0.891.271.271.521.521.781.782.032.29

0.891.271.271.271.521.521.781.782.03

0.891.021.271.271.521.521.521.781.78

0.3130.4780.5720.6830.8880.9161.0931.2781.735

0.2550.3990.4620.5690.7140.7580.8841.0501.417

0.2310.3600.4150.4900.6350.6590.7860.9121.235

0.2000.2890.3480.4070.5290.5450.6310.7500.991

3057

113169280302503671

1394

193772

108177213319424882

12234668

112134200266553

81529437185

126168347

7.9412.1414.5417.3422.5623.2627.7632.4644.08

6.4810.1411.7414.4418.1419.2622.4626.6635.98

5.889.14

10.5412.4416.1416.7419.9623.1631.36

5.087.348.84

10.3413.4413.8416.0419.0625.16

4485

168251417450749998

2075

2955

107160264317474631

1312

183468

101166200298396823

12224364

105126187250517

80181305447758854

125716973346

51122194296481562803

21642606

3893

144208355400589790

1546

275899

139239265374521985

119270454665

11281271187025254979

76182289440716837

119532203878

57139215310529596877

11762301

4086

147207355395556775

1466

www.2mkablo.com 10

300V Instrumentation Cables

300V 105°CPVC Insulated Unshielded Triads ITC/PLTC

Construction

Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, red continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer) Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250

Technical and Electrical Properties (20 °C)

Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests

Oil ResistanceSunlight Resistance

:: :: : : ::::

::

300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft20.08 14.97 14.97 11.82100.1 at 15.6°Cfixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)UL 1581 section 1200

www.2mkablo.com11

300V Instrumentation Cables

*14/7

*16/7

*18/7

12468101216182450

12468101216182450

12468101216182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGTriad

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015

0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015

0.510.510.510.510.510.510.510.510.510.510.51

0.380.380.380.380.380.380.380.380.380.380.38

0.380.380.380.380.380.380.380.380.380.380.38

0.0400.0500.0600.0700.0700.0700.0700.0800.0800.0900.090

0.0400.0500.0500.0600.0600.0700.0700.0700.0700.0800.090

0.0350.0500.0500.0600.0600.0600.0600.0700.0700.0700.080

1.021.271.521.781.781.781.782.032.032.292.29

1.021.271.271.521.521.781.781.781.782.032.29

0.891.271.271.521.521.521.521.781.781.782.03

0.3280.5290.6350.7820.8800.9911.0301.1641.2271.4601.960

0.2810.4430.5130.6310.7100.8210.8490.9390.9911.1801.609

0.2430.3990.4580.5650.6310.7100.7340.8330.8801.0261.388

4284

168252335419503670754

10052091

2754

107160213266319425477636

1322

173468

101134167200266299398827

8.3413.4416.1419.8622.3625.1626.1629.5631.1637.0849.78

7.1411.2413.0416.0418.0420.8621.5623.8625.1629.9640.88

6.1810.1411.6414.3416.0418.0418.6421.1622.3626.0635.26

63125250375499623749997

112214953112

4080

159238317396475632710946

1967

2550

101150199248297396445593

1231

103243414632816

103811821549173623864667

69163263403518679770989

110615233004

49122194296381480544719800

10832135

154362616940

1215154417592305258435516945

103243391599771

101111461472164622674470

73181289441567714810

1070119116123177

www.2mkablo.com 12

300V Instrumentation Cables

12468101216182450

*20/7

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGTriad

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.012

0.30.30.30.30.30.30.30.30.30.30.3

0.0350.0400.0500.0500.0500.0600.0600.0700.0700.0700.080

0.891.021.271.271.271.521.521.781.781.782.03

0.2080.3170.3830.4540.5060.5880.6080.6710.7060.8411.132

1121426384

105126167188250519

5.288.049.74

11.5412.8414.9415.4417.0417.9421.3628.76

16316294

125157187249280372773

3476

130186241319359456508707

1382

50113193277358475534678756

10522056

www.2mkablo.com13

300V Instrumentation Cables

300V 105°C PVC Insulated,Unshielded Pairs with Overall ShieldITC/PLTC

Construction

Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer)Overall shield : Plastic coated aluminum tape in contact with tinned copper drain wire.Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250

Technical and Electrical Properties (20 °C)

Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft)Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests

Oil Resistance

:: :: : : ::::::

:

300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 ( VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS4066 part 1&3), EN 50266-2-2 ASTM No 2 oil 70°C 4 (ICEA S-73-532)

www.2mkablo.com 14

300V Instrumentation Cables

*14/7

*16/7

*18/7

12468101216182450

12468101216182450

12468101216182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015

0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015

0.510.510.510.510.510.510.510.510.510.510.51

0.380.380.380.380.380.380.380.380.380.380.38

0.380.380.380.380.380.380.380.380.380.380.38

0.0400.0500.0600.0600.0700.0700.0700.0700.0800.0800.090

0.0350.0500.0500.0600.0600.0600.0700.0700.0700.0800.090

0.0350.0500.0500.0500.0600.0600.0600.0700.0700.0700.080

1.021.271.521.521.781.781.781.782.032.032.29

0.891.271.271.521.521.521.781.781.782.032.29

0.891.271.271.271.521.521.521.781.781.782.03

0.3170.4820.5760.6870.7900.8920.9201.0221.0971.2821.739

0.2590.4030.4660.5720.6390.7180.7620.8450.8881.0541.420

0.2350.3640.4190.4940.5720.6390.6630.7500.7900.9161.239

2956

113167223279335447503669

1394

183671

107142177212282318424882

1223466789

111134177200265552

8.0412.2414.6417.4420.0622.6623.3625.9627.8632.5644.18

6.5810.2411.8414.5416.2418.2419.3621.4622.5626.7636.08

5.989.24

10.6412.5414.5416.2416.8419.0620.0623.2631.46

4384

168249332415499665748996

2074

2754

105159211263316420473631

1312

183468

100132165199264297395821

86188312454605767863

1106126617083360

56128200303388489570726812

11172177

4499

151214289362407536597799

1558

128280465676901

114112841646188425425000

83191298451577727848

1080120816633239

65148224319430538606798889

11892318

www.2mkablo.com15

300V Instrumentation Cables

*20/7

12468101216182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.012

0.30.30.30.30.30.30.30.30.30.30.3

0.0350.0400.0500.0500.0500.0600.0600.0700.0600.0700.070

0.891.021.271.271.271.521.521.781.521.781.78

0.2040.2930.3520.4110.4580.5330.5490.6040.6350.7540.994

8152842566983

111125167346

5.187.448.94

10.4411.6413.5413.9415.3416.1419.1625.26

1222426283

103124165186248515

3263

105144183245271343382529995

4794

156215272365404511569787

1480

www.2mkablo.com 16

300V Instrumentation Cables

300V 105°C PVC Insulated,Unshielded Triads with Overall ShieldITC/PLTC

Construction

Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3) Core Colors : Black, white, red continuously numberedon white core (1,2,3) for multielement Separator : Polyester tape (at least 1 layer)Overall Shield : Plastic coated aluminum tape in contactwith tinned copper drain wire Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250

Technical and Electrical Properties (20 °C)

Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests

Oil ResistanceSunlight Resistance

:: :: : : ::::

:

::

300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)UL 1581 section 1200

www.2mkablo.com17

300V Instrumentation Cables

*14/7

*16/7

*18/7

12468101216182450

12468101216182450

12468101216182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGTriad

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015

0.0150.0150.0150.0150.0150.0150.0150.0150.0150.0150.015

0.510.510.510.510.510.510.510.510.510.510.51

0.380.380.380.380.380.380.380.380.380.380.38

0.380.380.380.380.380.380.380.380.380.380.38

0.0400.0500.0600.0700.0700.0700.0700.0800.0800.0900.090

0.0400.0500.0500.0600.0600.0700.0700.0700.0700.0800.090

0.0350.0500.0500.0600.0600.0600.0600.0700.0700.0700.080

1.021.271.521.781.781.781.782.032.032.292.29

1.021.271.271.521.521.781.781.781.782.032.29

0.891.271.271.521.521.521.521.781.781.782.03

0.3320.5330.6390.7860.8840.9981.0341.1681.2311.4641.964

0.2850.4460.5170.6350.7140.8250.8530.9430.9941.1831.602

0.2470.4030.4620.5690.6350.7140.7380.8370.8841.0301.392

4284

167251335419503669754

10052091

2754

107159213265319424477635

1322

173467

101134167200265298398827

8.4413.5416.2419.9622.4625.3626.2629.6631.2637.1849.88

7.2411.3413.1416.1418.1420.9621.6623.9625.2630.0640.68

6.2810.2411.7414.4416.1418.1418.7421.2622.4626.1635.36

63125249374499623748996

112214953112

4080

159237317395474631710945

1967

255099

150199248297395444592

1230

109251423642828

105011931562175024034688

75170271411528691781

1001111915373022

54128200305390491553730813

10962151

162373629955

1232156317762324260535766976

111253403612786

102811631490166522884497

80190298454580730823

1086121016313201

www.2mkablo.com 18

300V Instrumentation Cables

*20/7

12468101216182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGTriad

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0.0120.0120.0120.0120.0120.0120.0120.0120.0120.0120.012

0.30.30.30.30.30.30.30.30.30.30.3

0.0350.0400.0500.0500.0500.0600.0600.0600.0600.0700.080

0.891.021.271.271.271.521.521.521.521.782.03

0.2120.3200.3870.4580.5090.5920.6120.6750.7100.8451.136

1121426284

105125167188249519

5.388.149.84

11.6412.9415.0415.5417.1418.0421.4628.86

16316293

125156186248280371773

3882

136193248327368465516719

1394

57122202287369487547692768

10702075

www.2mkablo.com19

300V Instrumentation Cables

300V 105°C PVC Insulated,Individual Pairs with Overall ShieldITC/PLTC

Construction

Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3)Core Colors : Black, white, continuously numberedon white core (1,2,3) for multielement Individual Shield : Plastic coated aluminum tape in contact with tinned copper drain wire.Separator : Polyester tape (at least 1 layer)Overall shield : Plastic coated aluminum tape in contactwith tinned copper drain wire.Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C),colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250

Technical and Electrical Properties (20 °C)

Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft)Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests

Oil Resistance

:: :: : : ::::::

:

300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2 ASTM No 2 oil 70°C 4 (ICEA S-73-532)

www.2mkablo.com 20

300V Instrumentation Cables

*14/7

*16/7

*18/7

246101218202450

246101218202450

246101218202450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0,0200,0200,0200,0200,0200,0200,0200,0200,020

0,0150,0150,0150,0150,0150,0150,0150,0150,015

0,0150,0150,0150,0150,0150,0150,0150,0150,015

0,510,510,510,510,510,510,510,510,51

0,380,380,380,380,380,380,380,380,38

0,380,380,380,380,380,380,380,380,38

0,0500,0600,0600,0700,0700,0700,0800,0800,090

0,0500,0500,0600,0600,0600,0700,0700,0800,090

0,0500,0500,0500,0600,0600,0700,0700,0700,080

1,271,521,521,781,781,782,032,032,29

1,271,271,521,521,521,781,782,032,29

1,271,271,271,521,521,781,781,782,03

0,5290,6350,7610,9911,0261,1991,2901,4311,944

0,4460,5130,6350,8010,8280,9911,0461,1801,594

0,4030,4660,5530,7180,7420,8840,9351,0341,400

56112167279335503558670

1394

3671

106177212318353424882

224467

110132198220265550

13,4416,1419,3425,1626,0630,4632,7636,3649,38

11,3413,0416,1420,3421,0425,1626,5629,9640,48

10,2411,8414,0418,2418,8422,4623,7626,2635,56

83166249415498748831997

2075

53105158263316473526631

1312

336699

164197295328394819

218362527897

10071445164319953926

152238357585658968

107513322605

119182261445498732810983

1920

324538785

133514992151244529695842

226354532870979

1441160019823876

177271389662741

1089120614632857

www.2mkablo.com21

300V Instrumentation Cables

*20/7

246101218202450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0,0120,0120,0120,0120,0120,0120,0120,0120,012

0,30,30,30,30,30,30,30,30,3

0,0400,0500,0500,0600,0600,0600,0700,0700,070

1,021,271,271,521,521,521,781,781,78

0,3280,3950,4660,6080,6240,7260,9351,0261,144

1428426984

125139167346

8,3410,0411,8415,4415,8418,4423,7626,0629,06

214262

103125186207248515

79130185312348490548682

1297

117194275464518729815

10151930

www.2mkablo.com 22

300V Instrumentation Cables

300V 105°C PVC Insulated, Individual Triadswith Overall Shield ITC/PLTC

Construction

Conductor : Plain annealed copper wires (7-stranded)size : AWG 14, AWG 16, AWG 18, AWG 20(ASTM B-3, Class B stranding per ASTM B-8)Insulation : Heat resistant PVC (UL 1581 class 105°C, EN 50363-3 TI3 ) Core Colors : Black, white, red continuously numberedon white core (1,2,3) for multielement Individual Shield : Plastic coated aluminum tape in contact with tinned copper drain wire. Separator : Polyester tape (at least 1 layer)Overall Shield : Plastic coated aluminum tape in contactwith tinned copper drain wire. Communication Wire : Stranded plain annealed copper wire,size AWG 22, PVC insulated colored orange Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 105°C)colour : Black, Blue [other colors upon request] Reference Standard : UL 13 - UL 2250 Technical and Electrical Properties (20 °C)

Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft)L/R ratio (max.μH/Ω)Insulation Thickness (mils)Insulation Resistance (MΩxkft) Capacitance (800 Hz) pF/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests

Oil ResistanceSunlight Resistance

:: :: : : ::::

:

::

300VCore-Core: 1500V Core-Screen: 1500VAWG 14 AWG 16 AWG 18 AWG 202.71 Ω/kft 4.36 Ω/kft 6.95 Ω/kft 10.92 Ω/kft60 40 25 2520.08 14.97 14.97 11.82100.1 at 15.6°C51.8fixed: -40°C ......+105°C during installation: -5°C ......+50°C7.5 x Cable diameterMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)UL 1581 section 1200

www.2mkablo.com23

300V Instrumentation Cables

*14/7

*16/7

*18/7

2468101216182450

2468101216182450

24681012182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGTriad

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0,0200,0200,0200,0200,0200,0200,0200,0200,0200,020

0,0150,0150,0150,0150,0150,0150,0150,0150,0150,015

0,0150,0150,0150,0150,0150,0150,0150,0150,015

0,510,510,510,510,510,510,510,510,510,51

0,380,380,380,380,380,380,380,380,380,38

0,380,380,380,380,380,380,380,380,38

0,0500,0600,0600,0700,0700,0700,0700,0800,0800,090

0,0500,0500,0600,0600,0600,0700,0700,0700,0800,090

0,0500,0500,0500,0600,0600,0600,0700,0700,080

1,271,521,521,781,781,781,782,032,032,29

1,271,271,521,521,521,781,781,782,032,29

1,271,271,271,521,521,521,781,782,03

0,5840,6980,8400,9671,0971,1361,2621,3531,5892,168

0,4940,5720,7060,7930,8990,9511,0541,1131,3251,798

0,4430,5090,6080,7020,7970,8200,9831,1481,561

84167251335419503669753

10052090

53106159212264318423476634

1321

3467

100133165199298397827

14,8417,7421,3424,5627,8628,8632,0634,3640,3655,08

12,5414,5417,9420,1422,8424,1626,7628,2633,6645,68

11,2412,9415,4417,8420,2420,8424,9629,1639,66

125249374499623748996

112114953111

79158236315393473630708944

1966

5099

149198246296443591

1230

288482710948

120413641753199927135369

196312474612779906

1161130017883516

155239347468591665976

13252595

429718

10561411179220302609297540387990

291465706911

116013491728193526615233

230355516696879990

145319723862

www.2mkablo.com 24

300V Instrumentation Cables

*20/7

2468101216182450

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGTriad

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

0,0120,0120,0120,0120,0120,0120,0120,0120,0120,012

0,30,30,30,30,30,30,30,30,30,3

0,0400,0500,0500,0500,0600,0600,0600,0600,0700,070

1,021,271,271,271,521,521,521,521,781,78

0,3560,4310,5090,5690,6630,6830,7571,0380,9511,262

21426383

104124166187249519

9,0410,9412,9414,4416,8417,3419,2426,3624,1632,06

316294

124155185247278370772

100167241309405455578646899

1723

149249359460602677860962

13382564

Instrumentation Cables

www.2mkablo.com

Instrumentation Cables

www.2mkablo.com

www.2mkablo.com27

600V Instrumentation Cables

600V, PVC/Nylon Insulated, 90°CType TC – UL 1277 – NEC ART 336

ApplicationsThe 600V Instrumentation Cables are listed as Type TC per UL 1277. Suitable for installations as described in NEC ART 336.Construction ConductorBare, annealed copper conforming to ASTM B-3 and Class B stranded in accordance to ASTM B-8.InsulationPVC/Nylon Type Flame retardant, 90°C temperature rating.Insulation Shield (Shielded pair/triad constructions)Aluminum foil/polyester shield helically wrapped to provide 100 % coverage with a tinned copper drain wire that is two gaugesizes smaller than the circuit conductorsJacketUL listed sunlight and moisture resistant, sequentially length marked, black, flame retardant polyvinyl chloride material. A Nylon ripcord can be included for ease of jacket removal.Features• UL approved Type TC, 600V• UL approved insulated conductors• UL 1685 and IEEE 383 vertical fire tests at 70,000 BTU/hr• Temperature rating 90°C dry• Sunlight and moisture resistant jacket• For use within Class 1 Division 2 and Class 2 Division 2 Hazardous Locations and Intrinsically Safe applications as permitted by NEC ART 392, 501, 502, 504 and 505.• Cables are rated for Direct Burial applications• For use in cable trays, raceways, conduit or for aerial applications where installed with a messenger• Cables may be used In Class 1 Circuits, as defined in NEC Section 336.10 and ART 725 for Type TC cables• The Nylon jacket provides excellent oil and gasoline protection.Specifications• UL 1277 Rated 90°C / 600V• UL requirements for Type TC• Designated Type TC per NEC ART 336

www.2mkablo.com 28

600V Instrumentation Cables

600V PVC/Nylon/PVCOverall Shielded Pairs/Triads TC-ER Rated

Construction

Conductor : Plain annealed stranded copper wires (ASTM B3, Class B stranding per ASTM B-8 IEC/EN 228, HD 383, BS 6360, VDE 0295)Insulation : Heat resistant PVC (UL 1581 class 90°C, EN 50363-3 TI3) with clear Polyamide (Nylon) Separator : Polyester tape (at least 1 layer)Drain Wire : Solid tinned copper wire AWG 18 : 7x0.0152 Inc.AWG 16 : 7x0.02 Inc.Shield : AL-PES foil, Aluminum contact with stranded tinnedcopper drain wire Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 90°C)Reference Standard : UL 1277

Technical and Electrical Properties (20 °C)

Max. Operating Voltage Conductor Resistance (Ω/kft)Insulation Thickness (mils)

Min. Bending Radius (fixed) Temperature RateOxygen Index Flame Tests

Oil Resistance

:: :

::::

:

600V AWG 16: 14.3 (4.36 Ω/kft) AWG 18: 22.7 (6.95 Ω/kft) AWG 16: 0.39 mils PVC + 0.12 mm NylonAWG 18: 15.36 mils PVC + 4.73 mils Nylon7.5 x Cable DiameterDry: 90°CMin. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1,IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2 ASTM No 2 oil 70°C 4 (ICEA S-73-532)

www.2mkablo.com29

600V Instrumentation Cables

11 TRI

23457121620243650

11 TRI

23457121620243650

*16/7

*18/7

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.510.510.510.510.510.510.510.510.510.510.510.510.51

0.510.510.510.510.510.510.510.510.510.510.510.510.51

0.0450.0450.0450.0450.0600.0600.0600.0600.0800.0800.0800.0800.080

0.0450.0450.0450.0450.0450.0600.0600.0600.0800.0800.0800.0800.080

1.141.141.141.141.521.521.521.522.032.032.032.032.03

1.141.141.141.141.141.521.521.522.032.032.032.032.03

0.2680.4610.4330.4610.5350.5830.6300.8230.9531.0551.1651.3311.555

0.2800.2950.3940.4170.4530.5280.5710.7360.8540.9451.0431.1891.382

182635527088

123211281352422633880

11 16 22 33 44 55 77

132 176 220 264 396 550

6.811.7

1111.713.614.8

1620.924.226.829.633.839.5

7.17.5

10.0010.6011.5013.4014.5018.7021.7024.0026.5030.2035.10

26395279

105131183314419524628943

1310

162533496682

115197262328393590819

56 87 97

123 169 199 254 400 548 662 776

10911464

46557493

113151189294406488570790

1052

83131145184252297378596816986

115616252180

6983

111139168225282438606727849

11761567

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

www.2mkablo.com 30

600V Instrumentation Cables

600V PVC/Nylon/PVCIndividual and Overall Shielded PairsTC-ER Rated

Construction

Conductor : Plain annealed stranded copper wires (ASTM B3, Class B stranding per ASTM B-8 IEC/EN 228, HD 383, BS 6360, VDE 0295)Insulation : Heat resistant PVC (UL 1581 class 90°C, EN 50363-3 TI3) with clear Polyamide (Nylon) Individual Separator : Polyester tapeIndividual Drain Wire : Solid tinned copper wire AWG 18 : 7x0.0152 Inc.AWG 16 : 7x0.02 Inc.Individual Shield : AL-PES foil, Aluminum contact with strandedtinned copper drain wire General Separator : Polyester tape (at least 1 layer)General Drain Wire : Solid tinned copper wire AWG 18 : 7x0.0152 Inc.AWG 16 : 7x0.02 Inc. General Shield : AL-PES foil, Aluminum contact with strandedtinned copper drain wire Sheath : Heat resistant and sunlight resistant PVC(UL 1581 class 90°C)Technical and Electrical Properties (20 °C)

Max. Operating Voltage Conductor Resistance (Ω/kft)Insulation Thickness (mils)

Min. Bending Radius (fixed) Temperature RateOxygen Index Flame Tests

Oil Resistance

:: :

::::

:

600VAWG 16: 14.3 (4.36 Ω/kft) AWG 18: 22.7 (6.95 Ω/kft) AWG 16: 0.39 mm PVC + 0.12 mm. NylonAWG 18: 15.36 mils PVC + 4.73 mils Nylon7.5 x Cable diameterDry: 90°C Min. 27%UL 1685 (vertical tray), UL 13 (VW-1), IEC/EN 60332-1, IEC 60332-3-22 (CAT-A), (BS 4066 part 1&3), EN 50266-2-2ASTM No 2 oil 70°C 4 (ICEA S-73-532)

www.2mkablo.com31

600V Instrumentation Cables

234578121620243650

23457121620243650

*16/7

*18/7

Min. AVGInsulation Thickness

Min. AVGJacket Thickness Nominal O.D.Conductor

AWGPair

NumberApproximate

Copper WeightApproximateCable Weight

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.0200.0200.0200.0200.0200.0200.0200.0200.0200.0200.020

0.510.510.510.510.510.510.510.510.510.510.510.51

0.510.510.510.510.510.510.510.510.510.510.51

0.040.040.040.060.060.060.060.080.080.080.080.08

0.040.040.040.060.060.060.080.080.080.080.08

1.141.141.141.521.521.521.522.032.032.032.032.03

1.141.141.141.521.521.522.032.032.032.032.03

0.490.520.570.660.710.800.931.081.201.331.521.78

0.440.470.510.590.640.830.961.071.201.351.58

35537088

123141211282352422634880

2233445577

132176220264396550

12.3813.1814.4816.6418.0420.2423.7427.4630.4633.7638.6645.26

11.1811.8812.9814.9416.2421.1424.4627.1630.4634.3640.06

5279

105131183210314419524628943

1310

33496682

115197262328393590819

154199252323418496714956

1187143820362816

115147

183.90238

305.80520698867

104714772036

230296374481622737

106314231766214030304191

171219274355455774

10391290155821983029

Inches(mm)

(±0.02) Inches(mm)

(±0.05) Inches(mm)(±%5)

(kg/km)(±%5)

(kg/km)(±%5)

LBS/1000 FT

LBS/1000 FT

Instrumentation Cables

www.2mkablo.com

Instrumentation Cables

www.2mkablo.com

NOTICE2M CABLE ensures the accuracy of the all data in this publication,however we cannot be liable for the consequences of errors or omissions.The installer and/or user assumes all liability for the consequencesof the installation and/or use of any of our products in contraventionof any applicable law, regulation or code.

Instrumentation Cables

www.2mkablo.com

internacional
Texto tecleado
around a world of cables
internacional
Texto tecleado
around a world of cables
internacional
Texto tecleado
around a world of cables
internacional
Texto tecleado
INARI ELECTRICS Madrid. SPAIN +34 91 635 39 17 [email protected]