Page 1: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

workplace6

Anika SpearsDesign Project Manager

Breakfast with the Stars

Page 2: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

2

If we were building your standard premium grade office building…

Energy= 87 kgCO2/m2

= 309 cars*

Water= 31,100,000L= 15.5 olympic pools*

• * based on a car producing 4.5t CO2/ year• ** based on an olympic pool capacity of 2 mega L

Page 3: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

3

Today

Ñ Overview

Ñ What made us 6 Green Star?

Ñ Computer fly through

Ñ Questions

Page 4: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

4

WE ARE HERE!

Page 5: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

5

How the project began…

Expression of interest

Building owner

Developer

D&C contractor

Page 6: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

6

How the project began…

Architect

Electrical, mechanicalhydraulics, lifts services & ABGR, daylight, PMV modeling

Structural Engineers

ESD advice

Page 7: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

7

Light shelves/sun hoods

Greenstructure

Operable windows Reused

materials

Low eglass

Page 8: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

8

75m

Typical Floor Plate

Ñ NLA 3,600m2

75m24m

Page 9: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

9

22Waste Man.MAN 7

11Commissioning AgentMAN 411Building Users GuideMAN 523Environmental Man.MAN 6

12

122

Points Available

Points Achieved

TitleCredit No

11Total

1Building TuningMAN 32Commissioning ClausesMAN 22GS Accredited ProfessionalMAN 1

ManagementWhat made us 6 Green Star?

Page 10: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

10

ManagementÑ We are all accredited professionals

Ñ CIBSE commissioning/ on going services tuning

Ñ Good construction management

CLASS ELECTRICAL SERVICES

Page 11: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

11

11Tenant Exhaust RiserIEQ 16

11Formaldehyde Min.IEQ 1411Mould PreventionIEQ 15

22Thermal ComfortIEQ 902Individual Temp. ControlIEQ 10

NaNaAsbestosIEQ 1112Internal Noise LevelsIEQ 1233VOCIEQ 13

12External ViewsIEQ 811Electric Lighting LevelsIEQ 7

03DaylightIEQ 401Daylight Control GlareIEQ 511High Frequency BallastsIEQ 6

26

123

Points Available

Points Achieved

TitleCredit No

16Total

1Carbon Dioxide MonitoringIEQ 32Air Change EffectivenessIEQ 21Ventilation RatesIEQ 1

Indoor Environment Quality

Page 12: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

12

External views

Good noise levelsInter-connecting

tenancy stair

Internal atrium

Natural daylight

Low VOCspaints, carpets,

adhesives & sealants

Page 13: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

13

External views

50% greater fresh air rates

Low VOC

Good air distribution

CO2monitoring

Comfortable noise levels

Mould prevention Good lighting design

Max 400 lux

High frequency ballasts

Chilled beams forthermal comfort

Page 14: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

14

34Office Lighting Power Den.ENE 511Office Lighting ZoningENE 622Peak Energy Demand Red.ENE 7

11Tenancy Sub meteringENE 4

24

115

Yes

Points Available

Points Achieved

TitleCredit No

21Total

1Electrical Sub meteringENE 313Energy ImprovementENE 2

YesEnergyENE 1

Energy

Page 15: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

15

efficient air conditioning

alternative energy

good lighting design

ABGR = 5 star + 40% improvement

Page 16: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

16

55Commuting Public TransportTRA 411

312

Points Available

Points Achieved

TitleCredit No

9Total

3Cyclist FacilitiesTRA 31Small Parking SpacesTRA 20Provision of Car ParkingTRA 1

Transport

Page 17: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

17

44Cooling Tower WaterWAT 411Fire Systems WaterWAT 5

13

125

Points Available

Points Achieved

TitleCredit No

13Total

1Landscape Irrigation WAT 32Water MetersWAT 25Potable Water EfficiencyWAT 1

Water

Page 18: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

18

Saving Water

Ñ 4 star water fixtures6 star urinals

Ñ Extensive water metering

Ñ No cooling towers16.5 million L/ yearsaved

Page 19: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

19

Ñ Produces 40,000L/ day

Recycle Water Factory

Ñ Sewer mining

Ñ On display for publicviewing

Page 20: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

20

Giving Back to the Community

Ñ Saving 31.1 million L of drinking water/ year!!

Ñ All site and park irrigation water

15,500L

15,500L

9,000L

Ñ Exceeding GreenStar benchmarks

Ñ All building grey water

workplace6

Page 21: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

21

33Recycled Content ConcreteMAT 522Recycled Content SteelMAT 622PVC MinimisationMAT 7

03Shell and Core/ Int. FitoutMAT 4

22Sustainable TimberMAT 814

NaNa2

Points Available

Points Achieved

TitleCredit No

11Total

NaRe-use StructureMAT 3NaRe-use FaçadeMAT 22Recycling Waste StorageMAT 1

Materials

Page 22: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

22

14Change in Eco ValueECO 401Topsoil and Fill RemovalECO 5

8

21

Yes

Points Available

Points Achieved

TitleCredit No

4Total

2Contaminated Land ECO 31Reuse of LandECO 2

YesEcological Value of SiteECO 1

Land Use and Ecology

Page 23: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

23

11Cooling TowersEMI 811Insulant ODPEMI 9

11Light PollutionEMI 7

22Watercourse PollutionEMI 544Reduced Flow to SewerEMI 6

11Refrigerant RecoveryEMI 4

14

112

Points Available

Points Achieved

TitleCredit No

13Total

1Refrigerant Leak DetectionEMI 30Refrigerant GWPEMI 22Refrigerant ODPEMI 1

Emissions

Page 24: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

24

5

5

Points Available

Points Achieved

TitleCredit No

3Total2Environment Design InitiativesINN 31Exceeding BenchmarksINN 2

Innovation

6 star = 75Workplace 6 = 83 points

Page 25: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

25

If we were standard…

Energy= 87 kgCO2/m2

= 309 cars*

Water= 31,100,000L= 15.5 olympic pools**

• * based on a car producing 4.5t CO2/ year• ** based on an olympic pool capacity of 2 mega L

but we are not!

Energy= 39 kgCO2/m2

= 138 cars

Water= 2,100,000L= 1 olympic pool

ZERO IMPACT

Page 26: workplace6 Presentation BWTS2 Presentation BWTS3.pdf · IEQ 16 Tenant Exhaust Riser 1 1 IEQ 14 Formaldehyde Min. 1 1 IEQ 15 Mould Prevention 1 1 IEQ 9 Thermal Comfort 2 2 IEQ 10 Individual

Panel question time

?