A central boiler running on natural gas or LPG, heats water; this then circulates through a network of pipes to a series of radiator panels. The hot water heats these radiator panels before returning to the boiler to be reheated and re-circulated. The radiators heat quickly to provide radiated and convected heat. This results in a clean, silent, draught free and very comfortable form of whole house heating. In other words ‘A Better Heating Solution’.
What is Radiator Central Heating?
Efficient - Delivers high efficiency at all times The high efficiency ratings of the Immergas range of boilers (up to 98%) means Radiator Central Heating is one of the most efficient ways to heat your home. Water transfers heat at a much higher rate than air, so radiators can heat a room in a matter of minutes. Most importantly, performance is maintained irrespective of the temperature outside, unlike some other heating alternatives.
* forced air can circulate allergies and dust
Comparison - Common forms of heating?
Why Choose Radiator (Whole House) Central Heating?
3
Comfortable & Healthy – Gentle ambient heatRadiant heating is widely accepted as the most comfortable form of heating. Naturally silent it delivers consistent warmth, and as it doesn’t rely on forced air, it provides a gentle ambient form of heat for the whole house*.
Controllable - Heat where and when you need itCompared to alternative single-source heating options that may only heat one room (often over heating), Radiator Central Heating is highly efficient and able to heat your whole house. A fully programmable thermostatically controlled Radiator Central Heating system gives you the flexibility to heat the whole house, or heat different rooms, to different temperatures, at different times of the day.
DOMESTICHOT WATER
Single heating appliance Under floorForced air Radiator
Immergas Boiler Range Immergas is the brand leader in Europe for both domestic condensing and traditional boilers. Immergas boilers are much more than just quality, functionality and reliability, they are also designed with elegant lines and a minimalist look.
Heating Instantaneous
Hot water
Stored Hot Water Option
Boiler Location
Fan Flued Typical
InstallationCondensing
Mini Eolo
X24 3 Yes * Internal ** 3Heating only small to medium sized house
24 3 3 Internal ** 3Heating and hot water to a small house with one bathroom
28 3 3 Internal ** 3Heating and hot water to a medium sized house with one bathroom
Eolo Extra
24kW 3 3External
(and Internal***) 3Heating and hot water to a small home with one bathroom
HP 30 3 3External
(and Internal ***) 3Heating and hot water to a medium sized home with one or two bathrooms 3
Victrix Superior
32kW X 3 Yes * Internal ** 3 Heating only to a large home 3 * Immergas boilers provides hot water to a hot water cylinder (hot water storage connection kit required).
** Can be located externally provided it is in a partially protected area like a carport.
*** An external boiler can also be located internally and flued externally. Flue kit required.
4
Mini Eolo Combi and heating only wall-hung compact boilers, room-sealed.
GENERAL CHARACTERISTICS• Available heat outputs of 24 and 28kW• EOLO: room-sealed, combi and heating only (X version)• Compact dimensions• Boiler diagnostic by display• Copper primary exchanger and stainless steel plates secondary exchanger• Combinable with external probe• Adjustable by-pass• Combinable with Immergas solar systems
Eolo Xtra Technical Data Unit of Measurement Mini Eolo 24 3 E Mini Eolo 28 3 E Mini Eolo X24 3 E
Hydroflow CodeN.GL.P.G
IB3.020853IB3.020853GPL
IB3.020856IB3.020856 GPL
IB3.020855IB3.020855GPL
Max heat output kW 24 28 24
Minimum heat output kW 9.3 11.2 9.3
Efficiency at 100% heat output % 93.6 94.3 93.6
Efficiency at 30% heat output % 90.3 91.1 90.3
Gas flow rate (N.G) max/min m3/h 2.71/0.88 3.14/1.02 2.71/0.88
LPG consumption Kg/h 2.03/0.83 2.35/1.00 2.03/0.83
DHW continuous flow rate at (30 deg rise) Lit/ min 11.5 13.4 N/A
Adjustable central heating temperature degrees c 35-85 35-85 35-85
Central heating expansion vessel capacity litre 6 8 6
Protection index IPX5D IPX5D IPX5D
Appliance weight (empty) Kg/h 34.5 40.8 33.9
NO
N C
ON
DE
NS
ING
Key:
G Gas supply
AC Domestic hot water outlet
AF Domestic cold water inlet
ACV Solar valve domestic hot water inlet (option)
R System return
M System flow
V Electric supply
A Inlet/outlet
B Inlet
MINI EOLO X24/24/28 3E
HYDRAULIC CONNECTIONS
Gas System D.H.W.
G R M AC AF
3/4” 3/4” 3/4” 1/2” 1/2”
5
Eolo Extra 24kWEolo Extra 24kW is an instantaneous wall-hung room sealed, fan assisted boiler, approved for working outdoors in the open using a special top cover kit, leaving more living space inside the house. It is compact and fits in well if installed outdoors thanks to its modern design.
GENERAL CHARACTERISTICS• Antifreeze system protects against temperatures as low as -15˚• Remote control used to easily and immediately control the boiler from inside
the home.• Complete and comprehensive range of air intake and outlet kits available, all
with a push-fit coupling system and silicone seals.• Copper primary exchanger and stainless steel plates secondary exchanger • Adjustable by-pass
AB B
Eolo Extra 24kW Technical Data Unit of Mmeasurement Eolo Extra 24kW
Hydroflow CodeNGLPG
IB3.018925IB3.018925GPL
Max heat output kW 24
Minimum heat output kW 9.3
Efficiency at 100% heat output % 92.8
Efficiency at 30% heat output % 90.7
Gas flow rate (N.G) max/min m3/h 2.74/1.01
LPG consumption Kg/h 2.04/0.84
DHW continuous flow rate at (30 deg rise) Lit/ min 11.1
Adjustable central heating temperature degrees c 35-85
Central heating expansion vessel capacity litre 5.1
Protection index IPX5D
Appliance weight (empty) Kg/h 44
NO
N C
ON
DE
NS
ING
Key:
G Gas Supply
AC Domestic Hot water outlet
AF Domestic Cold Water Inlet
ACV Solar valve domestic hot water inlet (option)
R System return
M System flow
V Electric supply
A Inlet/outlet
B Inlet
CONNECTIONS
Gas System D.H.W.
G R M AC AF
1/2” 3/4” 3/4” 1/2” 1/2”
6
7
Victrix Superior 32kW XWall-hung heating only condensing boiler.
GENERAL CHARACTERISTICS • Modulating heat output from 6.4 to 32kW• High efficiency and low pollutant emissions thanks to condensing technology• 3 star marking of sanitary comfort• Stainless steel condensing module• Adjustable system by-pass• Stainless steel domestic hot water heat exchanger• Electronic control board microprocessor driven• Electronic ignition and modulation
Victrix Superior 32kW X Technical Unit of Measurement Victrix Superior 32kW X
Hydroflow CodeN.G
L.P.GIB3.019104
IB3.019104GPL
Max heat output kW 32
Minimum heat output kW 6.4
Efficiency at 100% heat output % 98
Efficiency at 30% heat output % 100.6
Gas flow rate (N.G) max/min m3/h 3.46/0.70
LPG consumption max/min Kg/h 2.58/0.52
DHW continuous flow rate at (30 deg rise) Lit/ min N/A
Adjustable central heating temperature degrees c 35-85
Central heating expansion vessel capacity litre 8
Protection index IPX5D
Appliance weight (empty) Kg/h 47.5
A BB
Key:
G Gas supply
AC Domestic hot water outlet
AF Domestic cold water inlet
R System return
M System flow
V Electric supply
SC Condensate draining
CONNECTIONS
Gas System D.H.W.
G R M AC AF
1/2” 3/4” 3/4” 1/2” 1/2”
CO
ND
EN
SIN
G
Key:
G Gas supply
AC Domestic hot water outlet
AF Domestic cold water inlet
R System return
M System flow
V Electric supply
SC Condensate draining 25mm
ACV Solar valve domestic hot water inlet (option)
A Inlet/Outlet
B Inlet
HYDRAULIC CONNECTIONS
Gas System D.H.W.
G R M AC AF
1/2” 3/4” 3/4” 1/2” 1/2”
Eolo Extra kW HP 30Eolo Extra kW HP 30 is an instantaneous wall-hung combi condensing boiler for outdoor installation, for high temperature systems.
GENERAL CHARACTERISTICS • Modulating heat output up to 10.5kW• Heat output of 30kW• Designed for high temperature heating systems• Control board equipped with functional knobs• Automatic system by-pass
Eolo Extra kW HP 30 Technical Data Unit of Measurement Eolo Extra kW HP 30
Hydroflow CodeN.G
L.P.GIB3.021038
IB3.021038GPL
Max heat output kW 30
Minimum heat output kW 10.5
Efficiency at 100% heat output % 96.4
Efficiency at 30% heat output % 95.7
Gas flow rate (N.G) max/min m3/h 3.29/1.22
LPG consumption max/min Kg/h 2.46/0.90
DHW continuous flow rate at (30 deg rise) Lit/ min 14.3
Adjustable central heating temperature degrees c 35-85
Central heating expansion vessel capacity litre 8
Protection index IPX5D
Appliance weight (empty) Kg/h 45
CO
ND
EN
SIN
G
8
9
Boiler Flues and Accessories
n Blue Series - 60/100mm diameter
CodeFor use with non condensing boilers only Mini Eolo X24, 24, 28 & Eolo Extra 24kW
IB3.017736 Concentric horizontal complete kit
IB3.015631
Concentric vertical outlet (red ochre colour) to be combined with flange stub for vertical outlet
IB3.018277 1m
Extension pipe
IB3.010739 2m
IB3.011141Flanged stub pipe (vertical outlet adaptor)
IB3.010950 45˚ bend
IB3.010949 90˚ bend
IB3.011570Flanged stub-pipes for use with external boiler
IB3.011488Wind stop outlet for use with external boiler
n Green Series - 60/100mm diameter
CodeFor use with condensing boilers only Eolo Extra kW HP 30 and Victrix Superior 32kW X
IB3.012000Concentric horizontal complete kit
IB3.018501Concentric vertical outlet Complete kit.
IB3.012089 1m Extension pipe
IB3.016364Flanged stub-pipe for use with external boiler
IB3.015256Wind stop outlet for use with external boiler
IB3.012095 45˚ bend
IB3.012093 90˚ bend
Boiler Flues and Accessories continued
Code Controllers
IB3.021395 CAR V2Programmable room thermostat (modulating)Condensing and non condensing
IB3.021622 Crono 7On/Off programmable room thermostatCondensing and non condensing
Code Misc
IB3.019213 Storage tank connection kitVictrix Superior 32kWCondensing
IB3.020934 Storage tank connection kitMini EoloNon condensing
IB3.018911 Solar valve Condensing and non condensing
IB3.016304 Cover kit for Eolo Extra 24kW Non condensing
IB3.016022 Cover kit for Eolo Extra kW HP 30 Condensing
IB1.027190 Cillit inhibitor Anticorrosive and antiscaling fluid used to protect heating systems to be installed upon installation
NB: Failure to add inhibitor upon installation may invalidate warranties.
10
11
Immergas radiators can be installed in both high and low temperature heating systems. Immergas radiators are ideal in combination with Immergas boilers.
In order to obtain maximum thermal emission, the radiators should be installed using the following minimum recommended distances:
• 4cm from the wall• 12cm from the floor• 10cm from the top of a niche
Immergas radiators are protected during transportation by individual packaging using purpose-designed protection. All components required for assembly are included with each radiator.
Construction: 1.2mm thick steel panelsWorking Pressure: Up to 10 barMax Temperature: 110°CColour: White – RAL9010Standards: Manufactured in accordance with EN442. European Standard using latest generation
computer-controlled production techniques
Quality Assurance: UNI EN ISO 9001:2000Warranty: 10 years – with approved oxygen Barrier
Pipe system fitted and appropriate inhibitor added to the water.
Radiators
Design & InnovationOther radiator options are available on request, they include plastic, aluminium and towel radiators. These options are available in a range of colours, sizes and style options to suit your individual requirements.
Please contact your local Hydroflow representative for more information, [email protected].
Aluminium RadiatorsWith their elegant styling and contemporary design, our range of Ragall Aluminium radiators will complement any modern living space.
Immergas Radiators
12
Plastic Radiators : the latest innovation in home heating• Light, very easy to mount and use, even on prefab or plasterboard walls. Safe
during seismic activity • Clean, the characteristics of the raw material and the convection cycle prevent
dust deposits forming on or around the radiator.• Versatile, available in a range of sizes and colours• Quiet, unlike traditional radiators. Harmos radiators are virtually noise free during
their operation, due to their innovative material and construction.• Ecologically friendly, 100% recyclable. • Safe, produced using shockproof material with no sharp corners for maximum
safety for children and elderly people. • Durable, rust proof and resistant to saline corrosion.
Towel RadiatorsComplete your home heating with a stylish ladder style towel rail. These rails are designed with the contemporary home in mind and will ensure your towels are always warm and dry. Available in multiple widths and heights to ensure we have the perfect fit for your home.
Plastic radiator
Towel rail
Common Radiator Piping Configurations
STANDARD 1
Air release valve
STANDARD 3
STANDARD 2
COMPACT 1
Radiators
Standard Model Standard models are production equipped with four side hydraulic connections and fixing brackets.
Code Panel Fins Height (mm)Radiator Depth
(mm)Length (mm)
Heat Output
IS11600600 1 1 600 51 600 563w
IS11600800 1 1 600 51 800 751w
IS116001000 1 1 600 51 1000 939w
IS116001200 1 1 600 51 1200 1127w
IS116001400 1 1 600 51 1400 1315w
IS116001600 1 1 600 51 1600 1502w
IS21600800 2 1 600 76 800 1063w
IS216001000 2 1 600 76 1000 1329w
IS216001200 2 1 600 76 1200 1595w
IS216001400 2 1 600 76 1400 1861w
IS22400800 2 2 400 100 800 961w
IS224001000 2 2 400 100 1000 1201w
IS224001200 2 2 400 100 1200 1441w
IS22600400 2 2 600 100 400 675w
IS22600600 2 2 600 100 600 1012w
IS22600800 2 2 600 100 800 1350w
IS226001000 2 2 600 100 1000 1687w
IS226001200 2 2 600 100 1200 2024w
IS226001400 2 2 600 100 1400 2362w
IS226001600 2 2 600 100 1600 2699w
Compact Model The Compact models are production equipped with four side and two lower hydraulic connections, thermostatic valve, blind plugs and fixing brackets.
Code Panel Fins Height (mm) Depth (mm) Length (mm) Heat Output
IC11600600 1 1 600 51 600 551w
IC11600800 1 1 600 51 800 735w
IC116001000 1 1 600 51 1000 919w
IC116001200 1 1 600 51 1200 1103w
IC116001400 1 1 600 51 1400 1287w
IC116001600 1 1 600 51 1600 1470w
IC21600800 2 1 600 76 800 1057w
IC216001000 2 1 600 76 1000 1321w
IC216001200 2 1 600 76 1200 1585w
IC216001400 2 1 600 76 1400 1849w
IC216001600 2 1 600 76 1600 2114w
IC216002000 2 1 600 76 2000 2642w
IC22600400 2 2 600 100 400 658w
IC22600600 2 2 600 100 600 987w
IC22600800 2 2 600 100 800 1316w
IC226001000 2 2 600 100 1000 1645w
IC226001200 2 2 600 100 1200 1974w
IC226001400 2 2 600 100 1400 2303w
IC226001600 2 2 600 100 1600 2632w
1 fin and 1 panel
2 fins and 2 panels
1 fin and 2 panels
Technical Data
13The outputs are in accordance with EN442 standard. Working temperatures at 75/65, room temperature at 20 degrees C.
Radiator John Guest Valves and AccessoriesFor use with John Guest Pipe
Hydroflow Code Product Image
SPSC15 15mm x 1/2” SPSC22 22mm x 3/4”
Copper to speedfit adaptor
SPT10 10mmSPT15 15mmSPT22 22mm
Tee
SPM2210RK 22 X 10mm Rocket manifold
SPM2210 22mm X 10mmSPM2215 22mm X 15mm
Rail manifold
SP1050 10mm Pex barrier pipe coil 50m
SP155B 15mm Pex barrier pipe 5m (20 lengths)
SP225B 22mm Pex barrier pipe 5m (20 lengths)
LRV10
Angled radiator valve with lockshield head
10mmSuitable for speedfit pipe
LRV1515mmSuitable for speedfit pipe
LRV1090Angled radiator valve with lockshield head(complete with 90 degree stem elbow)
10mmSuitable for speedfit pipe
LRV159015mmSuitable for speedfit pipe
14
Boiler
Tee
to more radiators
22mminlet
Rocket manifold
Copper to barrier pipe connector
4 x 10mm outlers
Lockshield radiator valve
Thermostatic radiator valve
15
Hydroflow Code Product Image
TRV10
Angled radiator valve with thermostatic head
10mmSuitable for speedfit pipe
TRV1515mmSuitable for speedfit pipe
TRV1090Angled radiator valve with thermostatic head (complete with 90 degree stem elbow)
10mmSuitable for speedfit pipe
TRV1590 15mmSuitable for speedfit pipe
WRV1090Angled radiator valve with wheel head (complete with 90 degree stem elbow)
10mmSuitable for speedfit pipe
WRV159015mm Suitable for speedfit pipe
WRV10
Angled radiator valve with wheel head
10mmSuitable for speedfit pipe
WRV1515mm Suitable for speedfit pipe
TC66 metre head, circulating pump, cast iron body with 130mm across the union faces
PA1 Pump unions 1 inch BSP (pair)
Radiator John Guest Valves and AccessoriesFor use with John Guest Pipe
Radiator Itap Valves And AccessoriesValves for use with Copper, Pex and Steel
Hydroflow Code Product Image
I891Itap thermostatic control head with oil filled element
I995-12V Itap radiator valve angle male with handle
I997-12 Itap radiator valve angle male lockshield
I894-12V Itap radiator valve straight female with handle
I895-12V Itap radiator valve straight male with handle
I896-12 Itap radiator valve lockshield straight female
I897-12 Itap radiator valve lockshield straight male
I994-12v Itap radiator valve angle female with handle
I996-12 Itap radiator valve lockshield angle female
I595-1215 Itap nut and olive 1/2 inch x 15mm
I595-1216 Itap nut & olive 1/2 inch x 16mm
I305 Itap straight to pipe valve
16
Design serviceIf required, Hydroflow offers a heating design service based on house plans.This design and quote will ensure the most effective and efficient heating system customised for individual living conditions.
For more information please contact a Hydroflow representative, [email protected]
17
The Plumbers ClubPurchase Immergas and accumulate Plumbers Club rewards points.For more details about The Plumbers Club contact:
Phone: 0800 600 648
Email: [email protected]
Web: www.theplumbersclub.co.nz
Small house approx 150
square metres
Medium house approx 200
square metres
Large house approx 250
square metre
Boiler and Accessories Hydroflow Code Qty Qty Qty
Immergas Boiler Mini Eolo X24 3 E IB3.020855 1 1 1
Immergas Horizontal Concentric Flue Kit IB3.017736 1 1 1
Immergas Remote Digital Control IB3.016362 1 1 1
Immergas Cillit HS23 System Cleaner IB1.027190 1 1 1
Radiators
Immergas Standard 11 H600 L=1200 IS116001200 1 1 1
Immergas Standard 11 H600 L=1000 IS116001000 3
Immergas Standard 11 H600 L=1400 IS116001400 1
Immergas Standard 21 H600 L=800 IS21600800 1
Immergas Standard 22 H600 L=600 IS22600600 1 2 2
Immergas Standard 22 H600 L=1200 IS226001200 1 1
Immergas Standard 22 H600 L=1400 IS226001400 1 1
Immergas Standard 22 H600 L=1000 IS226001000 3 3
Immergas Standard 22 H600 L=1600 IS226001600 1
Radiators Valves
JG Thermostatic Radiator Valve 10mm TRV10 5 7 9
JG Wheelhead Radiator Valve 10mm WRV10 1 1 1
JG Lockshield Radiator Valve 10mm LRV10 6 8 10
Pipework and Fittings
Speedfit Pex Pipe 15mm x 5m (1 Length only) SP155 4
Speedfit Pex Pipe 22mm x 5m (1 Length only) SP225 6 8 10
Speedfit Pex Pipe 10mm x 50m COIL SP1050 2 2 2
Speedfit Manifold 4 Port Rail 22 x 10 SPM2210 4
Speedfit Manifold 4 Way Rocket SPM2210RK 1 4
Speedfit Equal Tee 22mm SPT22 2 4 2
Speedfit Reducing Tee 22 x 10 x 22mm SPRT221022 4
Speedfit Reducing Tee 22 x 15 x 22mm SPRT221522 4
Speedfit Reducing Tee 22 x 22 x 15mm SPRT222215 2
Speedfit Equal Elbow 15mm SPE15 4
Speedfit Equal Elbow 22mm SPE22 4 6 4
Speedfit Reducing Connector 15 x 10mm SPRC1510 4
Speedfit Copper Connector 22mm SPSC22 2 2 2
Speedfit Pipe Insert 22mm SPI22 22 30 36
Speedfit Pipe Insert 10mm SPI10 18 16 20
Speedfit Pipe Insert 15mm SPI15 18
Speedfit Clippets 10mm SPCL10 40 50 50
Speedfit Clippets 15mm SPCL15 12
Speedfit Clippets 22mm SPCL22 10 20 20
18
PackagesThese packages are our suggested list of radiators, boilers and components required for whole house heating for various house sizes. These packages may vary depending on the construction and layout of the house.
Typical boiler applicationSealed System (Heating Only)
Sealed System (Heating & Stored Hot Water)
Instantaneous Hot Water (Combination Boiler)
Radiator Radiator Radiator
Return
Return
Radiator RadiatorRadiator
Radiator
Calorifier
19
Boiler
Boiler
Flow
Flow
Heating FlowH/W out
By-pass (optional)
By-pass (optional)
By-pass (optional)Cold mains inHeating Return