versalab cryo-free vsm system electronics vsm linear motor sample drive magnet power supply 3 tesla...
TRANSCRIPT
![Page 1: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/1.jpg)
51.5” (1.31m)
VersaLab Cryo-free VSMVersaLab Cryo-free VSM
System System ElectronicsElectronics
VSM linear VSM linear motor sample motor sample drivedrive
Magnet power Magnet power SupplySupply
3 Tesla 3 Tesla Niobium-Niobium-Titanium Titanium superconducting superconducting magnetmagnet
Sumitomo 4K Sumitomo 4K CryoCoolerCryoCooler
![Page 2: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/2.jpg)
VersaLab Cryo-free VSM OverviewVersaLab Cryo-free VSM Overview
Cryo-free using small Sumitomo 4 K CryoCoolerCryo-free using small Sumitomo 4 K CryoCooler Offers sensitivity of better than 1 x 10Offers sensitivity of better than 1 x 10-6-6 emu emu 3 tesla superconducting magnet3 tesla superconducting magnet
Temperature Range: 50 to 400 KTemperature Range: 50 to 400 K Cooling Down Time: ~ 90 minutesCooling Down Time: ~ 90 minutes VSM Sample Space: 6 mm (and an optional 1.2 cm)VSM Sample Space: 6 mm (and an optional 1.2 cm)
![Page 3: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/3.jpg)
VersaLab Cryo-free VSM Field ControlVersaLab Cryo-free VSM Field Control Magnet Design: Conductively-cooled NbTi Magnet Design: Conductively-cooled NbTi
SuperconductingSuperconducting Magnetic Field Range: -30 kOe to +30 kOeMagnetic Field Range: -30 kOe to +30 kOe Field Uniformity: 0.1% over 2.4 cmField Uniformity: 0.1% over 2.4 cm Field Charging Rate: 0.1 Oe/sec to 300 Oe/secField Charging Rate: 0.1 Oe/sec to 300 Oe/sec Field Setting Resolution: 60 mOe Field Setting Resolution: 60 mOe
![Page 4: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/4.jpg)
SensitivitySensitivity
NiFe thin film from NISTNiFe thin film from NIST RMS noise < 10RMS noise < 10-6-6 emu @ 1 sec averaging emu @ 1 sec averaging
![Page 5: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/5.jpg)
SensitivitySensitivity
![Page 6: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/6.jpg)
NoiseNoise
![Page 7: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/7.jpg)
Field ControlField Control
![Page 8: VersaLab Cryo-free VSM System Electronics VSM linear motor sample drive Magnet power Supply 3 Tesla Niobium- Titanium superconducting magnet Sumitomo 4K](https://reader036.vdocuments.us/reader036/viewer/2022062516/56649e385503460f94b282c5/html5/thumbnails/8.jpg)
VersaLab Cryo-free VSM VersaLab Cryo-free VSM Future OptionsFuture Options
1000 K Oven1000 K Oven Heat Capacity MeasurementsHeat Capacity Measurements AC Transport Electrical MeasurementsAC Transport Electrical Measurements Sample RotationSample Rotation