user manual search engine - icraftshi:in°iowner's manual icraftshi:in i permanently lubricated...

48
Owner's Manual I CRAFTSHI:IN°I Permanently Lubricated Single Stage Portable AiR COMPRESSOR Model No. 919.167600 = Safety Guidelines = Assembly = Operation = Maintenance = Troubleshooting = Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman 1000002920 Rev. o 06/22/07

Upload: others

Post on 23-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Owner's Manual

    I CRAFTSHI:IN°I

    Permanently LubricatedSingle StagePortable

    AiR COMPRESSOR

    Model No.

    919.167600

    = Safety Guidelines

    = Assembly

    = Operation

    = Maintenance

    = Troubleshooting

    = Repair Parts

    CAUTION: Read the Safety Guidelinesand All Instructions Carefully BeforeOperating.

    Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.Visit our Craftsman website: www.sears.com/craftsman

    1000002920 Rev.o 06/22/07

  • WARRANTY ................................................ 2SPECiFiCATiON CHART ...................................... 3

    SAFETY GUiDELiNES ...................................... 3-8GLOSSARY ................................................ 9ACCESSORIES ............................................ 10

    DUTY CYCLE .............................................. 10ASSEMBLY ............................................... 10

    iNSTALLATiON ......................................... 10-12OPERATION ............................................ 12-14

    MAINTENANCE ......................................... 15-16SERVICE AND ADJUSTMENTS ............................ 17-18STORAGE ................................................ 18

    TROUBLESHOOTING GUIDE .............................. 19-21REPAIR PARTS ......................................... 22-25ESPANOL .............................................. 26-45

    NOTES/NOTAS ............................................ 46

    REPAIR PROTECTION AGREEMENTS ......................... 47HOW TO ORDER REPAIR PARTS ...................... back cover

    ONE YEAR FULL WARRANTYIf this product fails due to a defect in material or workmanship within one yearfrom the date of purchase, Sears will at its option repair or replace it free ofcharge. Contact Sears at 1-800-4-MY-HOME ®to arrange for repair, or return itto the place of purchase for replacement.

    If this product is used for commercial or rental purposes, this warranty appliesfor only ninety days from the date of purchase.

    This warranty gives you specific legal rights and you may have other rightswhich vary from state to state.

    Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179

    1000002920 2-ENG

  • Model No. 919.167600Running HP "1.6Bore 2.875"Stroke 1.45"

    Voltage-Single Phase 120V/60HZMinimum Branch Circuit Requirement 15 ampsFuse Type Time DelayAir Tank Capacity (gallons) 26Approx. Cut-In 130 PSIApprox. Cut-out 160 PSISCFM @ 40 psig *6.3SCFM @ 90 psig *4.9

    * Tested per ISO 1217Refer to Glossary for abbreviations.

    This manual contains information that is important for you to know andunderstand. This information relates to protecting YOUR SAFETY andPREVENTING EQUIPMENT PROBLEMS. To help you recognize thisinformation, we use the symbols below. Please read the manual and payattention to these symbols.

    _ Indicates animminently

    hazardous situation which, if notavoided, will result in death orserious in'uLU_.

    _ Indicates apotentiallyhazardous situation which, if notavoided, could result in death orserious in'_

    _ Indicates apotentially

    hazardous situation which, if notavoided, _ result in minor ormoderate injury.

    _Used without thesafety alert symbol

    indicates a potentially hazardoussituation which, if not avoided, mayresult in p_gperty damage_.

    " e

    _Some dust created by power sanding, sawing, grinding,drilling, and other construction activities contains chemicals

    known to the State of California to cause cancer, birth defects or otherreproductive harm. Some example of these chemicals are:

    • lead from lead-based paints• crystalline silica from bricks and cement and other masonry products• arsenic and chromium from chemically-treated lumberYour risk from these exposures varies, depending on how often you do thistype of work. To reduce your exposure to these chemicals: work in a wellventilated area, and work with approved safety equipment, always wearOSNA/MSNA/NIOSN approved, properly fitting face mask or respiratorwhen using such tools.When using air tools, basic safety precautions should always be followed toreduce the risk of of personal injury.

    _This product contains chemicals, known to the State ofCalifornia to cause cancer, and birth defects or other

    reproductive harm. Wash hands after handling.

    3-ENG 1000002920

  • _Do not operate this unit until you read and _understand this instruction manual for safety,operation and maintenance instructions.

    SAVE THESE iNSTRUCTiONS

    _ RiSK OF EXPLOSION OR FiRE

    HOW TO PREVENT iT

    = • Always operate the compressorin a well ventilated area free ofcombustible materials, gasoline, orsolvent vapors.

    WHAT CAN HAPPEN

    It is normal for electrical contactswithin the motor and pressureswitch to spark.

    If electrical sparks from compressorcome into contact with flammablevapors, they may ignite, causing fireor explosion.

    Restricting any of the compressorventilation openings will causeserious overheating and couldcause fire.

    Unattended operation d thisproduct could result in personalinjury or property damage. Toreduce the risk d fire, do notallow the compressor to operateunattended.

    o

    o

    If spraying flammable materials,locate compressor at least 20 feet(6.1 m) away from spray area. Anadditional length of air hose may berequired.Store flammable materials ina secure location away fromcompresso_:Never place objects against or ontop of compressor.Operate compressor in an openarea at least 12" (30.5 cm) awayfrom any wall or obstruction thatwould restrict the flow of fresh air tothe ventilation openings.Operate compressor in a clean, drywell ventilated area. Do not operateunit indoors or in any confined area.

    Always remain in attendance withthe product when it is operating.Always turn off and unplug unitwhen not in use.

    1000002920 4-ENG

  • __ RISK TO BREATHING (ASPHYXiATiON)

    HOW TO PREVENT iT

    = Air obtained directly from thecompressor should never beused to supply air for humanconsumption. In order to use airproduced by this compressor forbreathing, suitable filters and in-linesafety equipment must be properlyinstalled. In-line filters and safetyequipment used in conjunction withthe compressor must be capableof treating air to all applicable localand federal codes prior to humanconsumption.

    • Sprayed materials such as paint, Work in an area with good crosspaint solvents, paint remover, ventilation. Read and follow theinsecticides, weed killers, may safety instructions provided on thecontain harmful vapors and label or safety data sheets for thepoisons, materials you are spraying. Always

    use certified safety equipment:OSHA!MSHA!NIOSH respiratoryprotection designed for use withyour specific application.

    _ D D

    RiSKorBURSTING

    WHAT CAN HAPPEN

    The compressed air directly fromyour compressor is not safe forbreathing. The air stream maycontain carbon monoxide, toxicvapors, or solid particles fromthe air tank. Breathing thesecontaminants can cause seriousinjury or death.

    Air Tank: The air tank on your Air Compressor is designed and may be UM coded(for units with air tanks greater than 6" (152 mm) diameter) according to ASMESection VIII, Div. 1 rules. All pressure vessels should be inspected once every twoyears. To find your state pressure vessels inspector, look under the Division of Laborand Industries in the government section of a phone book.The following conditions could lead to a weakening of the air tank, and result in aviolent air tank explosion:

    WHAT CAN HAPPEN HOW TO PREVENT iT

    Failure to properly drain condensed • Drain air tank daily or after eachwater from air tank, causing rust use. If air tank develops a leak,and thinning of the steel air tank. replace it immediately with a

    new air tank or replace the entirecompresso_:

    Modifications or attempted repairs • Never drill into, weld, or make anyto the air tank. modifications to the air tank or its

    attachments. Never attempt torepair a damaged or leaking airtank. Replace with a new air tank.

    5-ENG 1000002920

  • • Unauthorized modifications to • The air tank is designed to

    the safety valve or any other withstand specific operatingcomponents which control air tank pressures. Never make adjustmentspressure, or parts substitutions to alter the

    factory set operating pressures.

    o

    Attachments & accessories:

    Exceeding the pressure rating ofair tools, spray guns, air operatedaccessories, tires, and otherinflatables can cause them toexplode or fly apart, and couldresult in serious injury.

    Tires:

    Follow the equipmentmanufacturers recommendationand never exceed the maximumallowable pressure rating ofattachments. Never use compressorto inflate small low pressure objectssuch as children's toys, footballs,basketballs, etc.

    Over inflation of tires could result in _ Use a tire pressure gauge to checkserious injury and property damage, the tires pressure before each use

    and while inflating tires; see the tiresidewall for the correct tire pressure.

    NOTE: Air tanks, compressors and similarequipment used to inflate tires can fillsmall tires similar to these very rapidly.Adjust pressure regulator on air supplyto no more than the rating of the tirepressure. Add air in small increments andfrequently use the tire gauge to preventover inflation.

    __ RISK OF ELECTRICAL SHOCK

    WHAT CAN HAPPEN

    Your air compressor is powered byelectricity. Like any other electricallypowered device, If it is not usedproperly it may cause electricshock.

    Repairs attempted by unqualifiedpersonnel can result in seriousinjury or death by electrocution.

    Electrical Grounding: Failure toprovide adequate grounding tothis product could result in seriousinjury or death from electrocution.Refer to "Grounding Instructions"paragraph in the "Installation"section.

    HOW TO PREVENT IT

    Never operate the compressoroutdoors when it is raining or in wetconditions.

    Never operate compressor withprotective covers removed ordamaged.

    Any electrical wiring or repairsrequired on this product should beperformed by authorized servicecenter personnell in accordancewith national and local electricalcodes.

    Make certain that the electricalcircuit to which the compressoris connected provides properelectrical grounding, correct voltageand adequate fuse protection.

    1000002920 6-ENG

  • __ RISK FROM FLYING OBJECTS

    WHAT CAN HAPPEN HOW TO PREVENT iT

    • The compressed air stream can Always wear certified safetycause soft tissue damage to equipment: ANSi Z87.1 eyeexposed skin and can propel dirt, protection (CAN/CSA Z94.3)chips, loose particles, and small with side shields when using theobjects at high speed, resulting in compressor.property damage or personal injury. Never point any nozzle or sprayer

    toward any part d the body or atother people or animals.Always turn the compressor offand bleed pressure from the airhose and air tank before attemptingmaintenance, attaching tools oraccessories.

    • _ m D

    RiSKOFHOTSURFACESWHAT CAN HAPPEN J HOW TO PREVENT iT

    I

    o Touching exposed metal such as J• Never touch any exposed metalthe compressor head, engine head, parts on compressor during orengine exhaust or outlet tubes, can immediately after operation.result in serious burns. Compressor will remain hot for

    several minutes after operation.• Do not reach around protective

    shrouds or attempt maintenanceunt un t has been a owed to coo.

    __ _RiSKFROMMOViNGPARTS

    WHAT CAN HAPPEN

    Moving parts such as the pulley,flywheel, and belt can causeserious injury if they come intocontact with you or your clothing.

    HOW TO PREVENT iT

    Never operate the compressorwith guards or covers which aredamaged or removed.Keep your hair, clothing, and glovesaway from moving parts. Looseclothes, jewelry, or long hair can becaught in moving parts.Air vents may cover moving partsand should be avoided as well.

    7-ENG 1000002920

  • • Attempting to operate compressorwith damaged or missing parts orattempting to repair compressorwith protective shrouds removedcan expose you to moving partsand can result in serious injury.

    _ m D

    I_ _:_ RISK OF UNSAFE OPERATION

    WHAT CAN HAPPEN

    Unsafe operation of your aircompressor could lead to seriousinjury or death to you or others.

    __ RiSK OF FALLING

    WHAT CAN HAPPEN

    • A portable compressor canfall from a table, workbench,or roof causing damage to thecompressor and could result inserious injury or death to theoperator.

    Any repairs required on this productshould be performed by authorizedservice center personnel.

    HOW TO PREVENT IT

    Review and understand allinstructions and warnings in thismanual.

    Become familiar with the operationand controls of the air compressor.Keep operating area clear of allpersons, pets, and obstacles.Keep children away from the aircompressor at all times.Do not operate the product whenfatigued or under the influence ofalcohol or drugs. Stay alert at alltimes.

    Never defeat the safety features ofthis product.Equip area d operation with a fireextinguisher.Do not operate machine withmissing, broken, or unauthorizedparts.

    = D

    HOW TO PREVENT iT

    Always operate compressor in astable secure position to preventaccidental movement of the unit.Never operate compressor on aroof or other elevated position.Use additional air hose to reachhigh locations.

    1000002920 8-ENG

  • [__ RiSK OF INJURY FROM LiFTiNG

    WHAT CAN HAPPEN I HOW TO PREVENT iTI

    o Serious injury can result from * The compressor is too heavy toattempting to lift too heavy an I be lifted by one person. Obtainobject, assistance from others before

    ftng.

    RISK FROM NOISE

    WHAT CAN HAPPEN

    Under some conditions andduration of use, noise from thisproduct may contribute to hearingloss.

    SAVE THESE INSTRUCTIONSFOR FUTURE USE

    HOW TO PREVENT IT

    Always wear certified safetyequipment: ANSI $12.6 ($3.19)hearing protection.

    Become familiar with these termsbefore operating the unit.CFM: Cubic feet per minute.SCFM: Standard cubic feet per min-ute; a unit of measure of air delivery.PSIG: Pounds per square inch gauge;a unit of measure of pressure.Code Certification: Products thatbear one or more of the followingmarks: UL, CUL, ETL, CETL, havebeen evaluated by OSHA certifiedindependent safety laboratories andmeet the applicable Standards forSafety.Cut-in Pressure: While the motoris off, air tank pressure drops as youcontinue to use your accessory. When

    the tank pressure drops to a certainlow level the motor will restart auto-matically. The low pressure at whichthe motor automatically restarts iscalled "cut-in" pressure.Cut-Out Pressure: When an air com-pressor is turned on and begins torun, air pressure in the air tank beginsto build. It builds to a certain highpressure before the motor automati-cally shuts off, protecting your air tankfrom pressure higher than its capacity.The high pressure at which the motorshuts off is called "cut-out" pressure.Branch Circuit: Circuit carrying elec-tricity from electrical panel to outlet.

    9-ENG 1000002920

  • This unit is capable of powering the following Accessories. The accessories areavailable through the current Power and Hand Tool Catalog or full-line Searsstores.Accessories Refer to the selection chart located on• In Line Filter the unit to select the tools this unit is

    Tire Air Chuck capable of powering.

    Quick Connector Sets (various _ The use of anysizes) "--- other accessoryAir Pressure Regulators not recommended for use with

    • Oil Fog Lubricators this tool could be hazardous. UseAir Hose: 1/4", 3/8" or 1/2" I.D. in only accessories rated equal tovarious lengths or higher than the rating of the air

    compressor.

    This air compressor pump is capable is, the air compressor pump shouldof running continuously. However, to not run more than 30-45 minutes inprolong the life of your air compressor, any given hour.it is recommended that a 50%-75%average duty cycle be maintained; that

    Unpacking1. Remove unit from carton and discard all packaging.

    HOW TO SET UP YOUR UNIT GROUNDING INSTRUCTIONSLocation of the Air Compressor

    Locate the air compressor in aclean, dry and well ventilatedarea.The air compressor should belocated at least 12" (30.5 cm)away from the wall or otherobstructions that will interferewith the flow of air.

    Place the air compressor on a flatlevel surface resting on the rub-ber bumpers and wheelsThe air compressor pump andshroud are designed to allow forproper cooling. The ventilationopenings on the compressor arenecessary to maintain properoperating temperature. Do notplace rags or other containers onor near these openings.

    _Risk of Electrical-- Shock. In the eventof a short circuit, grounding reducesthe risk of shock by providing anescape wire for the electric current.This air compressor must beproperly grounded.

    The portable air compressor isequipped with a cord having a ground-ing wire with an appropriate groundingplug (see following illustrations).1. The cord set and plug with this

    unit contains a grounding pin.This plug MUST be used with agrounded outlet.

    iMPORTANT." The outlet being usedmust be installed and grounded inaccordance with all local codes andordinances.

    1000002920 10-ENG

  • 2, Make sure the outlet being usedhas the same configuration as thegrounded plug. DO NOT USE ANADAPTER. See illustration.

    attaching another length of hose toits end. Attach additional lengths ofhose as needed. Always use an airhose rated 300 PSi or greater.

    g _(_.GroundedOutlets

    Grounding Pin

    3. Inspect the plug and cord beforeeach use. Do not use if there aresigns of damage.

    4. If these grounding instructions arenot completely understood, or if indoubt as to whether the compres-sor is properly grounded, have theinstallation checked by a qualifiedelectrician.

    _Risk of ElectricalShock. iMPROPERGROUNDING CAN RESULT INELECTRICAL SHOCK.

    Do not modify the plug provided. Ifit does not fit the available outlet, acorrect outlet should be installed bya qualified electrician.Repairs to the cord set or plugMUST be made by a qualifiedelectrician.

    EXTENSION CORDSIf an extension cord must be used, besure it is:

    • a 3-wire extension cord that hasa 3-blade grounding plug, and a3-slot receptacle that will acceptthe plug on the product

    • in good condition• no longer than 50 feet (15.2 m)• 12 gauge (AWG) or larger. (Wire

    size increases as gauge numberdecreases. 10 AWG and 8 AWGmay also be used. DO NOT USE14 OR 16 AWG.)

    The use of anundersized extension

    cord will cause voltage to dropresulting in power loss to the motorand overheating, instead of usingan extension cord, increase theworking reach of the air hose by

    11- ENG

    VOLTAGE AND CIRCUITPROTECTION

    Refer to the specification chart for thevoltage and minimum branch circuitrequirements.

    Certain aircompressors can be

    operated on a 15 amp circuit if thefollowing conditions are met.

    1. Voltage supply to circuit mustcomply with the National ElectricalCode.

    2. Circuit is not used to supply anyother electrical needs.

    3. Extension cords comply withspecifications.

    4. Circuit is equipped with a 15 ampcircuit breaker or 15 amp timedelay fuse. NOTE: If compressoris connected to a circuit protectedby fuses, use only time delayfuses. Time delay fuses should bemarked "D" in Canada and "T" inthe US.

    If any of the above conditions cannotbe met, or if operation of the compres-sor repeatedly causes interruptionof the power, it may be necessary tooperate it from a 20 amp circuit. It isnot necessary to change the cord set.

    TRANSPORTING

    When transporting the compressor in avehicle, trailer, etc., make sure the tankis drained and the unit is secured withstraps to prevent tipping. Use carewhen driving to prevent tipping the unitover in the vehicle. Damage can occurto the compressor or surroundingitems if the compressor is tipped.

    LiftingAlways use twopeople when lift-ing and lift fromthe recommendedlift points. DONOT lift by wheelsor shroud.

    1000002920

  • Moving

    The wheels andhandle do not provide

    adequate clearance, stability, orsupport for pulling the unit up anddown stairs or steps. The unit must belifted or pushed up a ramp.

    1. Grasp handle of compressor andtilt compressor back to rest onwheels.

    _Risk of UnsafeOperation. Ensure

    proper footing and use cautionwhen rolling compressor so thatunit does not tip or cause loss ofbalance.

    2, When location is reached slowlylower compressor to ground.Always store compressor in avertical position resting on therubber bumpers and wheels.

    KNOW YOUR AIR COMPRESSORREAD THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATINGYOUR UNIT. Compare the illustrations with your unit to familiarize yourself withthe location of various controls and adjustments. Save this manual for futurereference.

    Pressure Tank Pressure GaugeSwitch

    Regulator

    Description of OperationBecome familiar with these controlsbefore operating the unit.Auto (I)/Off (O) Switch: Turn thisswitch "Auto (I)" to provide automaticpower to the pressure switch and"Off (O)" to remove power at the endof each use.

    Pressure Switch: The pressure switchautomatically starts the motor whenthe air tank pressure drops below thefactory set "cut-in" pressure. It stopsthe motor when the air tank pressurereaches the factory set "cut-out" pres-sure.

    Safety Valve: If the pressure switchdoes not shut off the air compressorat its "cut-out" pressure setting, thesafety valve will protect against high

    1000002920

    pressure by "popping out" at its fac-tory set pressure (slightly higher thanthe pressure switch "cut-out" setting).Outlet Pressure Gauge: The outletpressure gauge indicates the air pres-sure available at the outlet side of theregulator. This pressure is controlled bythe regulator and is always less than orequal to the tank pressure.Tank Pressure Gauge: The tank pres-sure gauge indicates the reserve airpressure in the tank.Regulator: Controls the atr pressureshown on the outlet pressure gauge.Pull the knob out and turn clockwiseto increase pressure and counterclock-wise to decrease pressure. When thedesired pressure is reached push knobin to lock in place.

    12- ENG

  • Universal Quick-Connect Body: Theuniversal quick-connect body acceptsthe three most popular styles of quick-connect plugs: Industrial, automotive(Tru-flate), and ARC. One hand push-to-connect operation makes connec-tions simple and easy.Drain Valve:The drain valve islocated at thebase of the airtank and is usedto drain conden-sation at the end of each use.Cooling System (not shown): Thiscompressor contains an advanceddesign cooling system. At the heart ofthis cooling system is an engineeredfan. It is perfectly normal for this fan toblow air through the vent holes in largeamounts. You know that the coolingsystem is working when air is beingexpelled.Air Compressor Pump (not shown):Compresses air into the air tank.Working air is not available until thecompressor has raised the air tankpressure above that required at the airoutlet.Check Valve:When the aircompressor isoperating, thecheck valve is"open", allowingcompressed air toenter the air tank. When the air

    compressor reaches "cut-out"pressure, the check valve "closes",allowing air pressure to remain insidethe air tank.PressureRemease Valve:The pressurerelease valvelocated on theside of the pres-sure switch, isdesigned toautomatically release compressed airfrom the compressor head and the out-let tube when the air compressor reach-es "cut-out" pressure or is shut off. Thepressure release valve allows the motorto restart freely. When the motor stops

    running, air will be heard escaping fromthis valve for a few seconds. No airshould be heard leaking when the motoris running or after the unit reaches "cut-out" pressure.Air intake Filter:This filter isdesigned to cleanair coming into thepump, This filtermust always beclean and ventila-tion openings freefrom obstructions, See "Maintenance",Motor Overload Protector: The motorhas a thermal overload protector. Ifthe motor overheats for any reason,the overload protector will shut off themotor. The motor must be allowed tocool down before restarting. To restart:1. Set the Auto/Off switch to "Off"

    and unplug unit.2. Allow the motor to cool.

    3. Plug the power cord into thecorrect branch circuit receptacle.

    4. Set the Auto/Off lever to "Auto"position.

    HOW TO USE YOUR UNIT

    Now to Step1. Set the Auto/Off switch to "Off".NOTE: When the unit has been turnedoff, it is normal to hear a short hiss ofair being released.

    Before Starting

    _Bo not operate thisunit until you read

    and understand this instructionmanual for safety, operation andmaintenance instructions.

    Break-in Procedure

    _Risk of propertydamage. Serious

    damage may result if the followingbreak-in instructions are not closelyfollowed.

    This procedure is required before theair compressor is put into service andwhen the check valve or a completecompressor pump has been replaced.1. Make sure the Auto/Off switch is

    in the "Off" position.

    13-ENG 1000002920

  • NOTE: Push coupler back until itclicks to prevent air from escapingthrough the quick connect.2. Plug the power cord into the

    correct branch circuit receptacle.(Refer to Voltage and CircuitProtection paragraph in theInstallation section of thismanual.)

    3. Open the drain valve (counter-clockwise) fully to permit air toescape and prevent air pressurebuild up in the air tank during thebreak-in period.

    _Risk from FlyingObjects. Always

    wear certified safety equipment:ANSI Z87.t eye protection (CAN/CSA Z94.3} with side shields asdebris can be kicked up into face.

    4. Move the Auto/Off switch to"Auto" position. The compressorwill start.

    5. Run the compressor for 15minutes. Make sure the drainvalve is open and there isminimal air pressure build-up intank.

    6. After 15 minutes, close the drainvalve by turning clockwise. Theair receiver will fill to "cut-out"pressure and the motor willstop.

    The compressor is now ready for use.

    Before Each Start-Up1. Place Auto/Off switch to "Off".

    2. Pull regulator knob out, turncounter-clockwise until it stops.Push knob in to lock in place.

    3. Attach hose and accessories.NOTE: The hose or accessory willrequire a quick connect plug if theair outlet is equipped with a quickconnect.

    _Risk of unsafeoperation. Firmly

    grasp air hose in hand wheninstalling or disconnecting toprevent hose whip.

    Risk of unsafeoperation. Do not

    use damaged or worn accessories.

    _Too much airpressure causes a

    hazardous risk of bursting. Checkthe manufacturer's maximumpressure rating for air tools andaccessories. The regulator outletpressure must never exceed themaximum pressure rating.

    _Risk of unsafeoperation.

    Compressed air from the unit maycontain water condensation andoil mist. Do not spray unfiltered airat an item that could be damagedby moisture. Some air tools andaccessories may require filteredair. Read the instructions for the airtools and accessories.

    How to Start1. Turn the Auto/Off switch to

    "On/Auto" and allow tank pres-sure to build. Motor will stopwhen tank pressure reaches "cut-out" pressure.

    2. Pull the regulator knob out andturn clockwise to increasepressure. When the desiredpressure is reached push knob into lock in place. The compressoris ready for use.

    Risk of fire or'_° - ""_=-- explosion. Always

    operate the air compressor in well-ventilated areas free of gasolineor other combustible vapors. Ifthe compressor is being used tooperate a sprayer DO NOT placenear the spray area.

    _lf any unusualnoise or vibrationis noticed, stop the compressorimmediately and have it checked bya trained service technician.

    The compressor is ready for use.

    1000002920 14-ENG

  • CUSTOMER RESPONSIBILITIES

    Procedure Daily Daily Weeklyor aftereach use

    Check safety valve X

    Inspect air filter X1

    Drain air tank X

    Check for unusual noise/vibration X

    Check for air leaks* X

    Clean compressor exterior X

    To check for air leaks apply a solution of soapy water around joints.While compressor is pumping to pressure and after pressure cutsout, look for air bubbles to form.

    1 - more frequent in dusty or humid conditions

    Risk of Unsafe"--- Operation. Unit

    cycles automatically when poweris on. When servicing, you maybe exposed to voltage sources,compressed air, or moving parts.Before servicing unit unplug ordisconnect electrical supply tothe air compressor, bleed tankof pressure, and allow the aircompressor to cool.

    To ensure efficient operation and lon-ger life of the air compressor, a routinemaintenance schedule should be pre-pared and followed. The above routinemaintenance schedule is geared to anair compressor in a normal workingenvironment operating on a daily basis.If necessary, the schedule should bemodified to suit the conditions underwhich your air compressor is used.The modifications will depend uponthe hours of operation and the work-ing environment. Compressors in anextremely dirty and/or hostile environ-ment will require a greater frequency ofall maintenance checks.

    NOTE: See "Operation" section for thelocation of controls.

    TO CHECK SAFETY VALVE

    _Risk of Bursting.-- If the safety valvedoes not work properly, over-pressurization may occur, causingair tank rupture or an explosion.

    _Risk from FlyingObjects. Alwayswear certified safety equipment:ANSI Z87.1 eye protection (CAN/CSA zg4.3) with side shields.

    Before starting compressor, pull thering on the safety valve to make surethat the safety valve operates freely, ifthe valve is stuck or does not operatesmoothly, it must be replaced with thesame type of valve.

    TO DRAIN TANK

    _Risk of UnsafeOperation. Risk

    from noise. Air tanks contain highpressure air. Keep face and otherbody parts away from outlet ofdrain. Use ANSi Z87.1 eye protection(CAN/CSA Z94.3) when draining asdebris can be kicked up into face.Use ear protection [ANSi $12.6($3.1g) hearing protection] as airflow noise is loud when draining.

    15-ENG 1000002920

  • NOTE: All compressed air systemsgenerate condensate that accumulatesin any drain point (e.g., tanks, filter, after-coolers, dryers). This condensate con-tains lubricating oil and/or substanceswhich may be regulated and must bedisposed d in accordance with local,state, and federal laws and regulations.1. Set the Auto/Off switch to "Off"

    and unplug unit.2. Pull the regulator knob out and

    turn counterclockwise to set theoutlet pressure to zero.

    3. Remove the air tool or accessory.4. Pull ring on safety valve allowing

    air to bleed from the tank untiltank pressure is approximately 20psi. Release safety valve ring.

    5. Drain water from air tank by open-ing drain valve (counter-clockwise)on bottom of tank.

    _Risk of bursting.Water will condense

    in the air tank. if not drained, waterwill corrode and weaken the air tankcausing a risk of air tank rupture.

    _Risk of propertydamage. Drain

    water from air tank may contain oiland rust which can cause stains.

    6. After the water has been drained,close the drain valve (clockwise).The air compressor can now bestored.

    NOTE: Ifdrain valve is plugged,release all air pressure. The valve canthen be removed, cleaned, the rein-stalled.

    AiR FILTER

    _Not surfaces. Risk__ of burn. Outlettube, pump head, and surroundingparts are very hot, do not touch.Allow compressor to cool prior toservicing.

    1. Place Auto/Off switch to "Off".2. Allow unit to cool.3. Remove filter cover from base.4. Remove element from filter base.5. Place new element back in filter

    base. Purchase replacement partsfrom your local dealer or autho-rized service center. Always useidentical replacement parts.

    6. Snap filter cover to filter base.

    _Risk of property__ damage. Do notoperate without air inlet filter

    1000002920 16-ENG

  • _Risk of unsafeoperation. Unit

    cycles automatically when power ison. When doing Maintenance, youmay be exposed to voltage sources,compressed air or moving parts.Personal injuries can occur.

    Before servicing:= Unplug or disconnect

    electrical supply to the aircompressor.

    • Bleed tank of pressure.• Allow the air compressor to

    coolALL MAINTENANCE AND REPAIROPERATIONS NOT LISTED MUSTBE PERFORMED BY TRAINEDSERVICE TECHNICIAN.

    TO REPLACE CHECK VALVE

    1. Release all air pressure from airtank. See "To Drain Tank" in theMaintenance section.

    2. Unplug outfit.3. Remove the shroud on the outlet

    tube side. NOTE: Remove screwwith T-20 Torx screwdriver andloosen all the tabs on the shroudwith a flat screwdriver beforeremoving.

    5,

    6,

    7,

    Using anadjust-ablewrenchloosen

    pressurerelieftube nutat airtank.Carefully Pressure Relief Tubemove pressure relief tube awayfrom check valve

    Unscrew the check valve (turncounterclockwise) using a 7/8"open end wrench. Note the orien-tation for reassembly.Using a screwdriver, carefully pushthe valve disc up and down.

    positionnothing isvisible.

    In closed positiondisc is visible.

    Using an adjustable wrench, loos-en outlet tube nut at air tank andpump head. Carefully move outlettube away from check valve.

    NOTE: The valve disc should movefreely up and down on a spring whichholds the valve disc in the closed posi-tion; if not the check valve needs to bereplaced.8. Install the new check valve (turn

    clockwise).9. Replace the pressure release tube.

    Tighten nut.10. Replace the outlet tube and tight-

    en nuts.

    11. Replace the shroud.12. Perform the Break-in Procedure.

    See "Break-in Procedure" in theOperation section.

    17-ENG 1000002920

  • TO REPLACE REGULATOR

    1. Release all air pressure from airtank. See "To Drain Tank" in theMaintenance section.

    2. Unplug compressor.3. Remove shrouds.

    4. Remove the outlet pressure gaugeand quick connect from theregulator.

    7. Assemble quick connect to newregulator and tighten.

    Connect

    5,

    6.

    OutletPressure

    ,,Gauge

    QuickConnect

    Remove the regulator.Reapply pipe sealant to outletpressure gauge and quickconnect.

    8. Apply pipe sealant tape to thenipple.

    9. Assemble the regulator. NOTE:Arrow indicates flow of air. Makesure it is pointing in the directionof air flow.

    10. Use the hex on quick connectto tightening regulator. Orient asshown.

    11. Assemble outlet pressure gauge.Orient outlet pressure gauge toread correctly.

    12. Replace shrouds.

    Before you store the air compressor,make sure you do the following:1. Review the "Maintenance" sec-

    tion on the preceding pages andperform scheduled maintenanceas necessary.

    2. Set the Auto/Off lever to "Off".3. Turn the regulator counterclock-

    wise and set the outlet pressureto zero.

    4. Remove the air tool or accessory.5. Pull ring on safety valve allowing

    air to bleed from the tank untiltank pressure is approximately 20PSI. Release safety valve ring.

    6. Drain water from air tank byopening drain valve on bottom oftank.

    _ Water will condensein the air tank. If

    not drained, water will corrode andweaken the air tank causing a riskof air tank rupture.

    7. After the water has been drained,close the drain or drain valve.

    NOTE: If drain valve is plugged,release all air pressure. The valve canthen be removed, cleaned, then rein-stalled.

    8. To protect the electrical cordfrom damage wind electrical cordloosely around the compressorhandle.

    Store the air compressor in a cleanand dry location.

    1000002920 18-ENG

  • _Risk of Unsafe Operation. Unit cycles automatically whenpower is on. When servicing, you may be exposed to

    voltage sources, compressed air, or moving parts. Before servicing unitunplug or disconnect electrical supply to the air compressor, bleed tank ofpressure, and allow the air compressor to cool

    PROBLEM CAUSE CORRECTION

    Excessive Pressure switch does not Move Auto/Off lever to thetank pressure shut off motor when "Off" position, if the outfit- safety valve compressor reaches does not shut off contact apops off. "cut-out" pressure. Trained Service Technician.

    Pressure switch "cut-out" Contact a Trained Servicetoo high. Technician.

    Air leaks at fit- Tube fittings are not tighttings, enough.

    Check valve seat damaged.Air leaks at orinside checkvalve.

    Air leaks atpressure switchrelease valve.

    Air leaks in airtank or at airtank welds.

    Defective pressure switchrelease valve.

    Defective air tank.

    Air leaks Leaking seal.between headand valve plate.

    Tighten fittings where air canbe heard escaping. Check fit-tings with soapy water solu-tion, Do Not Overtighten.

    A defective check valve resultsin a constant air leak at thepressure release valve whenthere is pressure in the tankand the compressor is shutoff. Replace check valve.Refer to the "To ReplaceCheck Valve" in the Serviceand Adjustment section.

    Contact a Trained ServiceTechnician.

    Air tank must be replaced. Donot repair the leak.

    Risk of-- BurstingDo not drill into, weld orotherwise modify air tank orit will weaken. The tank canrupture or explode.

    Contact a Trained ServiceTechnician.

    19-ENG 1000002920

  • PROBLEM CORRECTION

    Pressure read-ing on the regu-lated pressuregauge dropswhen an acces-sory is used.

    CAUSE

    It is normal for "some"aressure drop to occu£

    Knocking Noise. Possible defect in safetyvalve.

    Defective check valve.

    Compressor is Prolonged excessive use ofnot supplying air.enough airto operateaccessories. Compressor is not large Check the accessory air

    enough for air requirement, requirement. If it is higherthan the SCFM or pressuresupplied by your aircompressor, you need alarger compressor.

    Hole in hose. Check and replace if required.

    Check valve restricted. Replace check valve.

    Air leaks. Tighten fittings.

    Restricted air intake filter. Clean or replace air intakefilter. Do not operate theair compressor with the fil-ter removed. Refer to the"Air Filter" paragraph in theMaintenance section.

    Regulator knob Damaged regulator. Replace.has continuousair leak.

    Regulator will Damaged regulator. Replace.not shut off airoutlet.

    If there is an excessiveamount of pressure drop whenthe accessory is used, adjustthe regulator following theinstructions in the "Descriptionof Operation" paragraph in theOperation section.NOTE: Adjust the regulatedpressure under flowconditions (while accessory isbeing used).

    Operate safety valve manuallyby pulling on ring. If valve stillleaks, it should be replaced.

    Replace check valve.

    Decrease amount of air usage.

    1000002920 20-ENG

  • PROBLEM

    Motor will notrun.

    CAUSE

    Motor overload protectionswitch has tripped.

    Tank pressure exceeds3ressure switch "cut-in"pressure.

    Extension cord is wronglength or gauge.

    Check valve stuck open.

    Loose electrical connections.

    Possible defective motor.

    Paint spray on internal motor3arts.

    Pressure release valve on9ressure switch has notunloaded head pressure.

    Fuse blown, circuit breakertripped.

    Compressor is trippingthe Ground Fault CurrentInterrupt (GFCI) switch.

    Faulty pressure switch

    21- ENG

    CORRECTION

    Refer to "Motor OverloadProtection" under Operation.If motor overload protectiontrips frequently, contact aTrained Service Technician.

    Motor will start automaticallywhen tank pressure dropsbelow "cut-in" pressure ofpressure switch.

    Check for proper gauge wireand cord length.

    Replace check valve.

    Have checked by a TrainedService Technician.

    Have checked by a TrainedService Technician.

    Have checked by a TrainedService Technician. Do notoperate the compressor in thepaint spray area. See flam-mable vapor warning.

    Bleed the line by pushing thelever on the pressure switch tothe "Off" position; if the valvedoes not open, replace switch.

    Check fuse box for blownfuse and replace asnecessary. Reset circuitbreaker. Do not use a fuseor circuit breaker withhigher rating than thatspecified for your particu-lar branch circuit.Check for proper fuse.You should use a timedelay fuse.

    3. Check for low voltageconditions and/or properextension cord.

    4. Disconnect the otherelectrical appliances fromcircuit or operate thecompressor on its ownbranch circuit.

    Have checked by a TrainedService Technician.

    Have checked by a TrainedService Technician.

    1000002920

  • Air Compressor Model Number 919.167600

    PARTS SHOWN FOR REFERENCE ONLY

    29

    _P

    2

    876856

    1000002920 Air Compressor - MODEL NUMBER 9t9.16760 06/oTTs

    1000002920 22-ENG

  • Air Compressor Model Number 919.167600

    iTEM PARTNO. NO. DESCRiPTiON QTY

    2 SST-5314-1 Rubber Bumper 23 91895680 Screw 34 CAC-60 Bolt 25 D23138 Wheel 26 SSF-8111-ZN Nut 2

    7 1000001808 Handle Assembly 18 D21172 Screw 49 D26615 Power Cord (14ga) 110 A19122 Tube 111 5130039-00 Sleeve 112 SSP-7811 Assembly Nut Sleeve 1/4 113 A19715 Check Valve 1

    14 SSP-7812 Nut Sleeve Assembly 1/2 115 1000001958 Nipple 116 D20114 Safety Valve 117 1000000274 Manifold Assy, 118 Z-D21929 Gauge 119 SSP-6021 Bushing Reducer 120 1000001952 Pressure Switch 121 A17326 Cover 122 AC-0716 Isolator 3

    23 D24263 Inlet Filter (Incl, Filter) 123 D24322 Filter Replacement 124 A03857 Washer 125 SUDL-9-1 Screw 426 ACG-18 Saddle Mount Cup 127 A02425 Motor Cord 128 ACG-408 Screw 329 A13364 Rear Shroud 130 1000000249 Pump Assembly, 131 AC-0781 O-ring 132 AC-0780 Nut 133 1000001588 Outlet Tube 134 A13363 Front Shroud 138 LA-3027 Drain Tank Label 144 LA-3108 Hot Surface Label 145 LA-2876 Power Cord Label 1

    46 1000003082 Warning Label 147 1000003008 Name Plate 1

    48 LA-3021 Warning Label 150 A06891 Drain Valve 1

    59 Z-D27212 Gauge 160 SS-2071 Nipple 169 A10157 Brush 2856 1000000543 Blow Gun Kit 1856 875-191182 Wrench 1856 919-18288-B Ratchet 1856 A14264 Air Hose 1856 AC-0625 Teflon Tape 1856 D20597 Quick Connect Plug 1876 D29185 Inflate/Deflate Kit 1

    23- ENG 1000002920

  • Air Compressor Model Number 919.167600

    75

    84

    90

    87¸¸¸̧¸

    1000002920 24- ENG

  • Air Compressor Model Number 919.167600

    ITEM PART

    NO. NO, DESCRIPTION QTY

    74 A12210 Belt 1

    75 Al1031 Fan 176 A08547 Screw 1

    79 A10811 Flywheel 180 A17572 Connection Rod & Piston

    Assembly 181 A08454 Screw 1

    84 A12204 Cylinder Sleeve 185 A09819 Valve Plate Assembly 186 A12477 Head 187 AC-0798 Screw 4

    89 ACG-45 O-ring 190 A03856 O-ring 1

    NOT SHOWN1000002920 Owner's Manual

    25-ENG 1000002920

  • GARANTiA ....................................................... 26

    CUADRO DE ESPEClFICACIONES ................................... 27

    DEFINICIONES DE NORMAS DE SEGURIDAD .......................... 27

    IMPORTANTES INSTRUCCIONES DE SEGURIDAD .................... 27-33

    GLOSARIO ....................................................... 33

    ACCESORIOS .................................................... 33

    ClCLO DE SERVlClO .............................................. 34

    ENSAMBLADO ................................................... 34

    INSTALAClON .................................................. 34-35

    OPERACION ................................................... 36-38

    MANTENIMIENTO ............................................... 39-40

    SERVICIOS Y REGULACIONES .................................... 41-42

    ALMACENAJE .................................................... 42

    GULP, DE DIAGNOSTICO DE PROBLEMAS ........................... 43-45

    NOTES/NOTAS ................................................... 47

    LISTA DE PARTES ............................................... 22-25

    COMO SOMClTAR PIEZAS PARA REPARACION ................. contratapa

    GARANTiA TOTAL DE UN A_IOSi esta unidad fallase debido a defectos de materiales o de fabricaci6n dentrodel afio de su fecha de compra, Sears, a su opci6n, Io reparara o reemplazarasin costo alguno. Comuniquese con Sears al 1-800-4-MY-HOMP paracoordinar su reparaci6n, o devuelva la unidad al lugar donde Io compr6 paraque Io cambien.

    Si esta unidad se usase con fines comerciales o para alquiler, esta garantfa seaplica s61o durante los primeros noventa dfas a partir de su fecha de compra.

    Esta garantia le otorga derechos especfficos y usted podria tenet otrosderechos que varian de un estado a otro.

    Sears, Roebuck and Co., Dept. 817WA, Hoffrnan Estates, IL 60179

    1000002920 26-SP

  • Modelo N°

    HP de TrabajoDi_metro interiorCarreraTensi6n monof_sica

    Circuito minimo requeridoTipo de fusibleCapacidad de aire en el tanquePresi6n de corte de entradaPresi6n de corte de salida

    SCFM a 40 psig

    SCFM a 90 psig

    919.167600

    "1,62,875 pulg. (73,0 mm)1,45 pulg. (36,8 mm)120V/60HZ15AAcci6n retardada

    26 Galones (98,4 litros)130 PSI160 PSI

    *6,3 Calibre de libras por pulgada cuadrada

    *4,9 Calibre de libras per pulgada cuadrada

    * Probado seg0n la norma ISO 1217RefiSrase al glosario para descifrar las abreviaturas.

    Este manual contiene informaci6n que es impoC_ante que usted conozca y comprenda. Estainformaci6n se relaciona con la protecci6n de SU SEGURIDAD y LA PREVENClON DEPROBLEMAS A SU EQUIPO. Para ayudarle a reconocer esta informaci6n, usamos lossimbolos indicades m_s abajo. Sirvase leer el manual y prestar atenci6n a estas secciones.

    _ Indica una situaci6n denesgo inminente, que si

    no se evita, causar_ Ja muerte o lesJonesserias.

    Indica unasituaci6npotencialmente riesgosa, que si no seevita, podria causar la muerte o lesienesserJas.

    _ Indica una situaci6npotencJalmente

    peligrosa, que si no se evita, puedecausar Jesiones meneres o moderadas.

    _ Usado sin el simbolode seguridad de

    aleC_aindica una situaci6n potencialmenteriesgosa la que, si no se evita, podriacausar da_os en la prepiedad.

    _ Algunas partJculas originadas al lijar, aserrar, amelar, taladrar yrealizar otras actividades de construcci6n contienen productosquimieos reconocidos pot el Estado de California como causantes de c,_ncer, defectosde nacimiento u otros problemas reproductives. Algunos ejemplos de estos productosquimicos son:

    • el plomo de las pinturas de base plomo" la silice cristalina de ladrillos, cemento y otros productos de mamposteria,, el ars_nico y cromo de madera con tratamiento quimico.

    El riesgo derivade de estas e×pesiciones varia seg=3n la frecuencia con la que serealice este tipo de trabajo. Para reducir la exposici6n a estos productos quimicos:trabaje en &teas bien ventiladas y con equipes de seguridad aprobados, use siem-pre mascarilla facial o de respiraci6n adecuada y aprebada per OSHA/MSHA/NIOSHcuando use este tipo de herramientas.Cuando se utilizan herramientas neum_ticas, siempre se deben respetar las precau-cienes de seguridad para reducir el riesgo de lesiones personales.

    _Este producto contiene sustancias quimicas, reconocidas potel Estade de California como causantes de c_ncer, defectos de

    nacimiento u otros preblemas reproductivos. L_vese las manes despu_s de utilizarlo.

    ,,, . , , La operaci6n o el mantenimiento inadecuados deeste producto podrJan ocasJenar lesiones serias y

    dales a la propiedad. Lea y comprenda todas las advertencias einstrucciones de funcionamiento antes de utilizar este equipo.

    27- SP 1000002920

  • CONSERVE ESTAS |NSTRUCCIONES

    ___ RIESGO DE EXPLOSION O INCENDIO

    _,QU_: PUEDE SUCEDER? COMO EVITARLO

    • Es normal que los contactos el6ctricos • Opere siempre el compresor en undentro del motor y el interruptor de Area bien ventilada libre de materialespresi6n produzcan chispas, combustibles, gasolina o vapores de

    solventes.

    Si las chispas el_ctricas del compresorentran en contacto con vaporesinflamables, pueden encenderse,provocando un incendio o una explosi6n.

    o Restringir cualquiera de las aberturasde ventilaci6n del compresor puedeproducir un sobrecalentamiento grave ypodr[a provocar un incendio.

    o El funcionamiento sin atenci6n de esteproducto podr[a provocar lesionespersonales o da_os a la propiedad.Para disminuir el riesgo de incendio, nopermita que el compresor funcione sinque alguien Io controle.

    Si se pulverizan materiales inflamables,ubique el compresor al menos a 6,1 m(20 pies) del Area de pulverizaci6n. Sepuede necesitar manguera adicional.Guarde los materiales inflamables enlugar seguro lejos del compresor.

    Nunca coloque objetos contra o sobre elcompresor.Opere el compresor en un lugarabierto con una distancia de al menos30,5 cm (12 pulg.) a cualquier pared uobstrucci6n que pudiera restringir elflujo de aire fresco a las aberturas deventilaci6n.

    Opere el compresor en un _rea limpia,seca y bien ventilada. No opere la unidaddentro de la casa o en un Area muycerrada.

    Permanezca siempre controlandoel producto cuando est_ enfuncionamiento.

    Siempre apague y desenchufe la unidadcuando no est_ en uso.

    __ RIESGO RESPIRATORIO (ASFIXlA)

    _,QU_: PUEDE SUCEDER?

    El aire comprimido que sale de sucompresor no es seguro para respirarlo.El flujo de aire puede contener mon6xidode carbono, vapores t6xicos o particulass61idas del tanque de aire. Respirar estoscontaminantes puede provocar lesionesgraves o la muerte.

    COMO EVITARLO

    El aire que se obtiene directamente delcompresor no se debe usar nunca paraconsumo humano. Para poder utilizar elaire producido por este compresor pararespirar, se deben instalar correctamentefiltros y equipos en I[nea adecuados.Los filtros y los equipos de seguridaden I[nea que se usan junto con elcompresor deben ser capaces de tratarel aire segLin todos los c6digos localesy federales antes de que sea consumidopor seres humanos.

    1000002920 28- SP

  • Los materiales pulverizados como * Trabaje en un Area con buena ventilaci6npintura, solventes para pinturas, I cruzada. Lea y siga las instruccionesremovedor de pintura, insecticidas y I de seguridad que se proveen en laherbicidas pueden contener vapores I etiqueta o en la ficha tecnica de losda_inos y venenos, materiales que est_ utilizando. Utilice

    siempre equipo de seguridad certificado:protecci6n respiratoria aprobada porNIOSH/OSHA y dise_ada para usar paraos f nes que usted requ ere.

    RIESGODEEXPLOSI6N

    Tanque de aire: El tanque de aire de su compresor de aire estA dise_ado y puedetener c6digo UM (para unidades con tanques de aire de m_s de 152 mm (6 pulgadas)de diAmetro) segOn las normas de la ASME, Secci6n VIII, Div. 1. Todos los recipientes depresi6n se deben inspeccionar cada dos a_os. Para encontrar al inspector de recipientesde presi6n de su estado, busque en la Divisi6n Trabajo e Industrias de la secci6n guber-namental de la gu[a telef6nica para obtener ayuda.Las siguientes condiciones podr[an Ilevar a un debilitamiento del tanque de aire, y provo-car una explosi6n violenta del tanque:

    &QUE PUEDE SUCEDER?

    o No drenar correctamente el aguacondensada del tanque de aire, queprovoca 6xido y adelgazamiento deltanque de aire de acero.

    • Modificaciones o intento de reparaci6ndel tanque de aire.

    Las modificaciones no autorizadas dela v_lvula de seguridad o cualquier otrocomponente que controle la presi6n deltanque.

    Elementos y accesorios:

    ,, Exceder las indicaciones de presi6npara las herramientas neumaticas, laspistolas pulverizadoras, los accesoriosneumAticos, los neum_ticos y otrosart[culos inflables puede hacer queexploten o revienten, y puede provocarlesiones graves.

    COMO EVITARLO

    Drene el tanque diariamente o luegode cada use. Si un tanque de airepresenta una p_rdida, reemplaceloinmediatamente con un tanque nuevo oreemplace todo el compresor.

    Nunca perfore, suelde o haga ningunamodificaci6n al tanque de aire o a suselementos. Nunca intente reparar untanque de aire da_ado o con perdidas.Reemplacelo con un tanque de airenuevo.

    El tanque est_ dise_ado para soportardeterminadas presiones de operaci6n.Nunca realice ajustes ni sustituya piezaspara cambiar las presiones de operaci6nfijadas en la f_brica.

    • Siga la recomendaci6n del fabricante del

    equipo y nunca exceda el nivel mAximode presi6n aceptable para los elementos.Nunca utilice el compresor para inflarobjetos peque_os de baja presi6n, talescomo juguetes de ni_os, pelotas defOtbol o de basquetbol, etc.

    29-SP 1000002920

  • Neum_ticos:

    o El inflado excesivo de los neum_ticospodr[a causar lesiones graves y dado ala propiedad.

    ,, Utilice un medidor de presi6n deneum_ticos para controlar la presi6nde 6stos antes de cada use y mientraslos infla; observe el flanco para ver lapresi6n correcta del neumAtico.

    NOTA: Los tanques de aire, los com-presores y el equipo similar que se usa parainflar neum_ticos pueden Ilenar neum_ticospequedos como estos con mucha rapidez.Ajuste el regulador de presi6n en el sumin-istro de aire a un valor que no supere el dela presi6n del neumAtico. Agregue aire enforma gradual y use con frecuencia el medi-dor de presi6n de neumAticos para evitarinflarlos.

    _ RIESGO DE DESCARGA ELI_CTRICA

    _,QUE PUEDE SUCEDER?

    o Su compresor de aire funcionacon electricidad. Come cualquierotro mecanismo que funcionacon electricidad, si no se Io utilizacorrectamente puede provocardescargas el6ctricas.

    • Que personal no calificado intenterealizar reparaciones puede provocarlesiones graves o muerte porelectrocuci6n.

    Puesta a tierra: La no colocaci6n dela puesta a tierra adecuada para esteproducto puede provocar lesionesgraves o muerte por electrocuci6n."Consulte las Instrucciones de Conexi6na tierra" en "lnstalaci6n".

    COMO EVITARLO

    Nunca haga funcionar el compresor alaire libre cuando est_ Iloviendo o encondiciones de humedad.

    Nunca haga funcionar el compresor sinlas cubiertas de protecci6n o si est_ndadadas.

    Cualquier cableado electrico o lasreparaciones requeridas para esteproducto deben ser realizadas por uncentre de servicio de un centro demantenimiento autorizado de acuerdocon los c6digos el_ctricos nacionales ylocales.

    AsegLirese de que el circuito electrico alque se conecta el compresor suministrela conexi6n a tierra adecuada, el voltajeadecuado y el fusible de protecci6nadecuado.

    1000002920 30- SP

  • __ RIESGO DE OBJETOS DESPEDIDOS

    _,QUE PUEDE SUCEDER?

    La corriente de aire comprimido puedeprovocar lesiones en los tejidos blandosde la piel expuesta y puede impulsarsuciedad, astillas, particulas sueltas yobjetos peque_os a gran velocidad, quepueden producir da_os en la propiedad ylesiones personales.

    COMO EVITARLO

    Utilice siempre equipo de seguridadcertificado: anteojos de seguridad ANSIZ87.1 (CAN/CSA Z94.3) con protecci6nlateral al usar el compresor.Nunca apunte ninguna boquilla nipulverizador a ninguna parte del cuerpoo a otras personas o animales.Apague siempre el compresor y drenela presi6n de la manguera de aire y deltanque de aire antes de intentar hacermantenimiento, conectar herramientas oaccesorios.

    " O

    _,QUE PUEDE SUCEDER?

    • Tocar metal expuesto come el cabezaldel compresor, el cabezal del motor, elescape del motor, o los tubes de salidapuede provocar quemaduras graves.

    RIESGO DE SUPERFiCiES CALIENTES

    RIESGO&QUE PUEDE SUCEDER?

    = Las piezas m6viles como la polea, elvolante y la correa pueden provocarlesiones graves si entran en contactocon usted o con sus ropas.

    Intentar hacer funcionar el compresorcon partes da_adas o faltantes, ointentar reparar el compresor sin lascubiertas protectoras puede exponerloa piezas m6viles Io que puede provocarlesiones graves.

    COMO EVITARLO

    Nunca toque ninguna parte metalicaexpuesta del compresor duranteo inmediatamente despu6s de sufuncionamiento. El compresor continuarAcaliente durante varies minutos despu_sde su funcionamiento.

    No toque las cubiertas protectoras niintente realizar mantenimiento hasta quela unidad se haya enfriado.

    " O

    POR PIEZAS M6VILES

    COMO EVITARLO

    Nunca haga funcionar el compresorsin los protectores o cubiertas o si losmismos estAn da_ados.

    Mantenga el cabello, la ropa y losguantes alejados de las piezas enmovimiento. Las ropas holgadas, lasjoyas o el cabello largo pueden quedaratrapados en las piezas m6viles.Los orificios de ventilaci6n puedencubrir piezas en movimiento, per Io quetambien se deben evitar.

    Cualquier reparaci6n requerida poreste producto debe ser realizada porun centre de servicio de un centro deservicio autorizado.

    31-SP 1000002920

  • _ RIESGO DE OPERACION INSEGURA

    _,QUE PUEDE SUCEDER? COMO EVITARLO

    " La operaci6n insegura de su compresor Revise y comprenda todas lasde aire podria producir lesiones graves instrucciones y advertencias de esteo la muerte, a usted mismo o a otras manual.personas. Familiaricese con la operaci6n y los

    controles del compresor de aire.Mantenga el area de operaciones librede personas, mascotas y obst_culos.Mantenga a los ni_os alejados delcompresor de aire en todo momento.No opere el producto cuando est6cansado o bajo la influencia de alcoholo drogas. Mant6ngase alerta en todomomento.Nunca anule las caracterfsticas deseguridad de este producto.Equipe el area de operaciones conun extintor de incendios.

    No opere la maquina si faltanpiezas, siestas estan rotas o si noson las autorizadas.

    __ RIESGO DE CAiDAS

    _,QUE PUEDE SUCEDER?

    Un compresor po_&til se puede caer deuna mesa, banco o techo, provocandodaSos al compresor y puede producirlesiones graves o la muerte del operador.

    COMO EVITARLO

    o Opere siempre el compresor en unaposici6n estable y segura para evitar quela unidad se mueva accidentalmente.Nunca opere el compresor sobre untecho u otra ubicaci6n elevada. Utiliceuna manguera de aire adicional paraalcanzar las ubicaciones elevadas.

    [__ RIESGO DE LESION POR LEVANTARMUCHO PESO

    _,QUE PUEDE SUCEDER? COMO EVITARLO

    o El intento de levantar un objeto muy o El compresor es dernasiado pesadopesado puede provocar lesiones graves, como para que Io levante una sola

    persona. Consiga ayuda de otraspersonas para levantarlo.

    1000002920 32-SP

  • RIESGO POR RUIDOS

    &QUE PUEDE SUCEDER? COMO EVITARLO

    En determinadas condiciones y segQn el ,, Utilice siempre equipo de seguridadperiodo de uso, el ruido provocado pot certificado: protecci6n auditiva ANSIeste producto puede originar perdida de $12.6 ($3.19).audici6n.

    CONSERVE ESTAS INSTRUCCIONESPAPA FUTURAS CONSULTAS

    Esta unidad es suficiente para abastecer de energia electrica a los siguientes accesorios.Estos se encuentran disponibles a trav_s del cat,logo para herramientas electricas y man-uales, en cualquiera de los comercios que mantiene la linea completa de SEARS.

    Aecesorios• Filtro en linea,, Entrada de aire a neum_ticos

    ,, Juegos de conectores rapidos (variostama_os)

    ,_ Reguladores de presi6n de aireo Lubricadores de niebla de aceite

    ,, Manguera de aire: 1/4 plug., 3/8 plug.o 1/2 plug. D.I. en varias medidas

    Refierase al grafico de selecci6n ubicadosobre la unidad, para elegir el tipo de her-ramienta que esta unidad es capaz dehacer funcionar.

    usoaecesorlos no

    recomendados para utilizar con estaherramienta puede resultar peligroso. Usesolamente accesorios con una capacidadnominal igual o superior a la de lacompresor de aire.

    Familiaricese con los siguientes t6rminos,antes de operar la unidad:CFM: (Cubic feet per minute) Pies cObicospor minuto.SCFM: (Stardard cubic feet per minute) PiescObicos estAndar por minuto; una unidad demedida que permite medir la cantidad deentrega de aire.PSIG: (Pound per square inch) Libras por pul-gada cuadrada.C6digo de certificaci6n: Los productosque usan una o m_s de las siguientesmamas: UL, CUL, ETL, CETL, han sidoevaluados por OSHA, laboratorios inde-pendientes certificados en seguridad, yreLinen los estAndares suscriptos por los ala certificaci6n de la seguridad.Presibn minima de corte: Cuando elmotor estA apagado, la presi6n del tanquede aire baja a medida que usted continLiausando su accesorio. Cuando la presi6ndel tanque baja al valor fijado en fabricacomo punto bajo, el motor volver_ a

    arrancar autom_ticamente. La presi6nbaja a la cual el motor arranca autom_ti-camente, se llama presi6n "minima decorte".Presi6n maxima de corte: Cuando uncompresor de aire se enciende y comien-za a funcionar, la presi6n de aire en eltanque comienza a aumentar. Aumentahasta un valor de presi6n alto fijado enfAbrica antes de que el motor automAti-camente se apague protegiendo a sutanque de aire de presiones m_s altas quesu capacidad. La presi6n alta a la cual elmotor se apaga se llama presi6n "mAximade "corte".

    Ramal: Circuito electrico que transportaelectricidad desde el panel de controlhasta el tomacorriente.

    33-SP 1000002920

  • Esta bomba compresora de aire es capaz 50% y el 75%; ello significa que la bombade funcionar continuamente, sin embargo compresora no deberia trabajar m_s de 30para prolongar la vida Litil de su compresor a 45 minutes por hora.de aire se recomienda mantener un ciclopromedio de servicio que oscile entre el

    DI_BALLAGE

    1. Retirez I'appareil de sa boTte et jeteztout I'emballage.

    COMO PREPARAR LA UMDAD

    Lubicaci6n del cempresor de aire'_ Ubicar el compresor de aire en un

    lugar limpio, seco y bien ventilado.o El compresor de aire debe colo-

    carse alejado per Io menos 30,5 cm(12 pulg.) de las paredes u de cualqui-er otra obstrucci6n que interfiera conel flujo de aire.

    • Coloque el compresor de aire en unasuperficie plana apoyado sobre protec-tores de goma y ruedas.

    • La bomba del compresor de airey su carcasa han sido dise_adaspara permitir un enfriamiento adec-uado. Las aberturas de ventilaci6ndel compresor resultan - entonces- necesarias para el mantenimientode una adecuada temperatura defuncionamiento. No coloque g6neroso contenedores, encima, ni en lasproximidades de dichas aberturas.

    INSTRUCCIONES PARACONECTAR A TIERRA

    Riesgo de cheque-- el_ctrico, Antela eventualidad de un cortocircuito, lacone×i6n a tierra reduce el riesge deelectrocuci6n proveyendo un conductorde escape para la cerriente el_ctrica,Este compreeor de aire debe estaradecuadamente conectado a tierra,

    El compresor port_til de aire est_ equipadocon un cable que tiene un conductor des-tinado a tierra, con una espiga apropiadapara su conexi6n (ver las siguientes ilus-traciones).1. El cable que acompada a esta unidad

    tiene una espiga para conexi6n atierra. Esta DEBE ser utilizada con untomacorriente conectado a tierra.

    IMPORTANTE: El tomacorriente que serAutilizado deberA haber sido conectado atierra conforme a todos los c6digos localesy ordenanzas.2. AsegLirese de que el tomacorriente

    que serA utilizado tenga la mismaconfiguraci6n que el enchufe deconexi6n a tierra. NO UTILICE UNADAPTADOR. Ver figura.

    Enchufe _ Toma-

    I _ corrientes

    I _ J/ corlectados

    a tierra

    Espiga de conexiSn a tierra

    3. Inspeccione el enchufe y su cord6nantes de cada uso. No use si existi-eran signos de dar_os.

    4. Si las instrucciones de conexi6n a tierrano fueran completamente compren-didas, o si se estuviera ante la dudaacerca de que el compresor estuvieseadecuadamente conectado a tierra,haga verificar la instalaci6n per unelectricista competente.

    _ Riesgo de choque oel_ctrico. LA CONEXION

    INADECUADA A TIERRA PUEDEDETERMINAR UNA DESCARGAELECTRICA,

    No modifique el enchufe provisto, Si elmismo no penetrara el tomacorrientedisponible, un electricista cempetentedeber_ instalar une apropiado.La reparaci6n del cable o del enchufeDEBERA set efectuada per un electri-cista competente.

    1000002920 34-SP

  • CABLES PROLONGADORESSi - no obstante - debe utilizarse una exten-si6n de cable, asegLirese de que:o La extensi6n el6ctrica de 3 conduc-

    tores, tenga un enchufe de conexi6na tierra de 3 hojas, y que exista unrecept_culo que acepte el enchufedel producto.

    ,_ Est_ en buenas condiciones.

    No m_s largo que 15,2 m (50 pies).,_ Calibre 12 (AWG) o mayor. (La medida

    de los cables se incrementa a medidaque su nLimero ordinal decrece.10 y 8 AWG pueden ser usados tam-bi6n. NO USE 14 NI 16 AWG).

    _EI uso de cables deextensibn el_ctrica

    originar_ una caida de tensi6n, Io quedeterminar_ una p_rdida de potencia delmotor asi como su recalentamiento. Enlugar de utilizar un cable de extensi6nel_ctrica, incremente el alcance de lamanguera de aire dentro de la zonade trabajo, aSadi_ndole otto largo demanguera a su e×tremo. Conecte loslargos adicionales de manguera deacuerdo a su necesidad. Utilice siempreuna manguera de aire caiificada para300 PSi o m_s.

    PROTECCION DEL VOLTAJE Y DELCIRCUITO

    Acerca del voltaje y la minima cantidad decircuitos requeridos, refi@ase al cuadro deespecificaciones.Ciertos compresores de aire pueden seroperados en un cimuito de 15 A, siempreque se cumplan las siguientes condiciones:1. Que el voltaje suministrado a traves de

    los ramales del circuito sea de 15A.

    2. Que el circuito no sea utilizado paraalimentar ninguna otra necesidad el6c-trica (iluminaci6n, artefactos, etc.)

    3. Que los cables de extensi6n cumplancon las especificaciones.

    4. El cimuito cuenta con un disyuntor de15 amperios o un fusible de acci6nretardada de 15 amperios. NOTA: Siel compresor esta conectado a un cir-cuito protegido por fusibles, use s61ofusibles de acci6n retardada. Los fus-ibles de acci6n retardada deben estarmarcados con la letra "D" en Canaday "T" en EE.UU.

    Si cualquiera de las condiciones enumera-das no pudiese ser cumplida, o si el funcio-namiento del compresor causara reiteradasinterrupciones de la energia con la que seIo alimenta, podria ser necesario operaral mismo desde un circuito de 20A. Paraello no sera necesario cambiar su cable delimentaci6n.

    TRANSPORTE

    AI transportar el compresor en un vehfculo,remolque, etc., asegLirese de que el tanquese haya drenado y que la unidad est6 asegu-rada y colocada. Maneje con cuidado paraevitar que la unidad se incline en el vehiculo.El compresor o los elementos cimundantesse pueden da5ar si el compresor se inclina.

    Levantar ia Unidad

    Utilice siempre dospersonas cuandolevante la unidad ylevAntela desde lospuntosrecomendados. NOLEVANTE tomandola unidad de lasruedas o la cubierta.

    Ttasladar ia Unidad

    Riesgo de daSo a-- la propiedad. Lasruedas y la agarradera no brindan espacio,estabilidad ni apoyo adecuados parasubir o bajar la unidad per escaleras oescalones. La unidad se debe levantar, o

    empujar, sobre una rampa.

    1. Tome la agarradera del compresor eincline el compresor de nuevo a restoen las ruedas.

    _ Riesgo.deoperacl6n insegura.

    Asegure el punto de apoyo adecuadoy tenga precauci6n al desplazar elcompresor de manera que ia unidad nose incline ni pierda ei equiiibrio.

    2. Cuando Ilegue al lugar deseado, bajelentamente del compresor hacia elpiso. Conserve siempre el compresoren vertical posici6n sobre las patas yruedas de goma.

    35-SP 1000002920

  • CONOZCA SU COMPRESOR DE AIRELEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DEOPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarsecon la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para ref-erencias futuras.

    DESCRIPClON DE OPERAClONESFamiliaricese con estos controles antes deoperar la unidad.Interrupter Auto (I}/Off(O}: Mueva esteinterrupter a la posici6n "Auto (I)" paradar contacto autom_tico al interrupterde presi6n, y "Off (O)" para interrumpir laenergfa el6ctrica al termino del use.Interrupter de presi6n: El interrupter depresi6n permite el arranque automAticodel motor cuando la presi6n del tanquedisminuye per debajo del valor de lapresi6n de conexi6n regulada en f_brica.El motor se detendrA cuando la presi6ndel tanque alcance los valores de presi6nde corte, regulado en fabrica para sudesconexi6n.

    V&lvula de seguridad: Si el interrupterde presi6n dejara de cortar el suministrode presi6n del compresor conforme alos valores prefijados para la presi6n decooke, la vAIvula de seguridad protegeracontra la presi6n elevada, "saltando" deacuerdo a los valores prefijados en fabrica(ligeramente superiores a los de presi6n deco¢(e de la Ilave interruptora.)Man6metro para centrolar la presi6nde salida, Este man6metro indicar_ lapresi6n de aire disponible a la salida delregulador. Esta presi6n est_ controlada perel regulador yes siempre menor o igualque la presi6n del tanque de aire.Man6metro de la presi6n del tanque:El man6metro que controla la presi6n deltanque indica la reserva de presiOn deltanque de aire.

    Regulador: Controla la presi6n de airemostrada en el man6metro de salida. Tirede la perilla y girela en sentido horario paraincrementar la presi6n, y h_galo en sentidoinverse para disminuirla. Cuando se Iogrela presi6n deseada, presione la perilla parabloquearla.Cuerpo universal de eonexi6n r_pida:El cuerpo universal de conexi6n r_pidaacepta los tres estilos m_s comunes deconexi6n universal: industrial, automotor(Tru-flate) y ARe. La operaci6n conuna sola mane permite efectuar lasconexiones en forma simple y sencilla.V_lvula dedrenaje: La v&lvulade drenaje seencuentra ubicada

    sobre la base del drenajetanque de aire y seusa para drenar la condensaci6n al fin decada use.

    Sistema de enfriamiento (nomestrado}: Este compresor contieneun sistema de avanzada para elcontrol de enfriamiento. En el nL_cleode este sistema de enfriamiento hayun ventilador especialmente diseSado.Resulta perfectamente normal - paraeste ventilador - soplar aire en grandescantidades a trav6s de los orificios deventilaci6n. De tal manera se podr_ saberque el sistema de enfriamiento trabajacuando el aire esta siendo expelido.Bomba de compresi6n del aire (nomostrada): Comprime el aire dentro del

    1000002920 36-SP

  • tanque. El aire de trabajo no se encuentradisponible hasta que el compresor hayaalcanzado a Ilenar el tanque hasta un nivelde presi6n per encima del requerido parala salida del aire.

    V_lvula reguladora:Cuando elcompresor de airese encuentrafuncionando, lav_lvula reguladoraesta "abieC_a",permitiendo laentrada del aire comprimido al tanque deaire. Cuando el nivel de presi6n del tanquealcanza el punto de "coOke", la valvulareguladora "se cierra", reteniendo lapresi6n del aire dentro del tanque.V_lvulaaliviadora depresibn: Lav_lvula aliviadora

    de presi6n seencuentraubicada en elcostado del

    interrupter depresi6n; ha side disedada para liberarautom_ticamente el aire comprimido de lacabeza compresora y el tube de salida,cuando el compresor de aire alcanza lapresi6n de "co¢(e" o es apagado. Lav&lvula aliviadora de presi6n permite elarranque libre del motor. Cuando el motorse detiene, deber[a escucharse el escapedel aire a trav6s de dicha v_lvula duranteunos segundos. No debe escucharseescape alguno mientras el motor est_ enmarcha, ni p_rdidas continuas una vez quese alcanz6 la presi6n "de corte".Filtro para laentrada del aire:Este filtro est_

    diseSado para limpiarel aire que entra a labomba. Dicho filtrodebe estar siemprelimpio y los orificiosde ventilaci6n libresde obstrucciones. Vea "Mantenimiento".

    Protector de sobrecarga del motor: Elmotor tiene un protector de sobrecarga tSr-mica. Si el motor se recalienta per algunaraz6n, el protector de sobrecarga apagar_el motor. Se debe permitir que el motor seenfr[e antes de volver a encenderlo. Paravolver a encenderlo:

    1. Coloque la palanca Auto/Off(En cendido/Autom_tico/Apagad o) enla posici6n "Off" y desenchufe la uni-dad.

    2. Espere que el motor se enfrie.3. Enchufe el cable el6ctrico en el recep-

    t_culo apropiado del circuito de deri-vaci6n.

    4. Coloque la palanca Auto/Off en laposici6n "Auto".

    come UTILIZAR SU UNIDAD

    Cbmo detenerla

    1. Coloque la posici6n de la Ilave inter-ruptora Auto/Off en la posici6n "Off".

    NOTA: Cuando se apag6 la unidad, es nor-mal que se escuche un silbido breve queindica la salida de aire.

    Antes de ponerlo en marcha

    _No opere estaunidad hasta que

    haya leido y comprendide este manualde instrucciones de seguridad, operaci6ny mantenimiento.

    Procedimiento de asentamiento

    =. , =, Rieego da_o ala propiedad. Si

    las siguientes instrucciones no fueeenseguidas estrictamente, pedr_n ecurrirseries da_os.

    1. AsegLirese que la palanca Auto/Offest8 en la posici6n "Off".

    NOTA: Tire del acoplamiento hacia atr_shasta percibir el "clic" que impide el escapedel aire de la conexi6n r_pida.2. Enchufe el cable de alimentaci6n en el

    receptaculo del ramal del circuito cor-recto. (Referirse al p_rrafo "Protecci6ndel voltaje y del circuito" en la secci6n"lnstalaci6n" de este manual).

    3. Abra completamente la valvula dedrenaje (sentido antihorario) a fin depermitir la salida del aire e impedirel aumento de la presi6n dentro deltanque de aire durante el periodo deasentamiento.

    _ Riesgo de objetosdespedidos.

    Utilice siempre equipo de seguridadcertificado: anteejos de seguridad ANSIZ87.1(CAN/CSA 2:94.3) con pretecci6nlateral ee pueden desprender residueshacia la cara.

    4. Mueva la palanca Auto/Off a laposici6n "Auto". El compresor se pon-dra en marcha.

    37- SP 1000002920

  • 5. Haga funcionar el compresor durante15 minutes. AsegQrese de que lav_lvula de drenaje est6 abierta y quela presi6n de aire acumulado en eltanque sea minima.

    6. Luego de 15 minutes, cierre la v_lvulade drenaje (sentido horatio). El airerecibido ir_ Ilenando hasta el puntode "corte" de presi6n, y el motor sedetendr&

    El compresor estara ahora listo para ser usado.

    Antes de eada puesta en marcha1. Coloque el interrupter Auto/Off en la

    posici6n "Off" y cierre el regulador deaire.

    2. Tire de la perilla del regulador, gireen sentido antihorario hasta el I[mite.Empuje la perilla hasta su posici6nblocante.

    3. Conecte la manguera y accesorios.NOTA: Tanto la manguera come losaccesorios requeriran un enchufe deconexi6n r_pida si la salida del aireest_ equipada con un z6calo de con-exi6n rapid&

    _ Riesgo.deeperaclen

    insegura. Sostenga la manguerafirmemente con las manes al instalarla odeseoneetarla para evitar la desconexibnrepentina de la manguera.

    _Riesgo.deoperation

    insegura, No utilioeJos aceesoriosda_ados o usados.

    _ Demasiada presi6nde aire podra ser

    la causa de riesgo de explosi6n. Verifiquelos vaiores de m_xima presi6n dados per elfabricante de las herramientas neumaticasy los accesorios. La presi6n de salida delregulador jamas debe exceder los vaiores dem_xima presi6n especificades.

    insegura. El aire comprimido de la unidadpuede contener condensaci6n de aguay emanaci6n de aceite. No pulvericeaire no filtrado sobre un articulo quepedria da6arse con la humedad. Algunosdispositives o herramientas neum&ticaspueden requerir aire filtrado. Lealas instruceienes del dispositivo o laherramienta neum&tica.

    C6mo porter en marcha1. Mueva la palanca Auto/Off a la

    posici6n "Auto" y deje que se incre-mente la presi6n del tanque. El motorse detendrA una vez alcanzado el valorde presi6n "de corte" del tanque.

    2. Tire de la perilla del regulador y gireen sentido horario para incrementar lapresi6n. Cuando el valor deseado depresi6n sea Iogrado, presione la perillahasta su posici6n blocante. El com-presor estar_ listo para ser usado.

    _ Riesgo de explosi6ne incendio. Opere

    siempre el compresor de aire en _reasbien ventiladas, libres de gasolina u otrasemanaciones combustibles. Si el compreserser_ utilizado para utilizar un rociador, NOIo coloque en las cercanias de la zona dereciado.

    _Si observa alg_nruido o vibraci6n

    inusuales, apague el compresor ycontacte a un t_cnico calificado enservicio.

    El compresor estar_ listo para ser usado.

    1000002920 38- SP

  • RESPONSABILIDADES DEL CLIENTE

    Procedimiento Diariamente Diariamente o luego Semanalmentede cada uso

    Controlar la v_lvula de Xsequridad

    Inspeccionar el filtro de X_aire

    Drenar el tanque de aire XControlar ruidos o vibra- Xclones inusuales

    Verificar si hay perdidas Xde aire*

    Limpiar el exterior del Xcompresor

    Para verificar si hay p6rdidas de aire aplique una soluci6n de agua jabonosa alred-edor de las juntas. Mientras el compresor bombea para generar presi6n y luego deque la presi6n se corte, vea si se forman burbujas de aire.M_s frecuente en condiciones polvorientas o hLimedas.

    _,b = , , L_ unidad funcionaautom_ticamente

    en ciclos cuande est_ conectada a laenergia. Cuando se realizan trabajosde mantenimiento, usted puede estarexpuesto a fuentes de voltaje, airecomprimide o piezas en movimiento.Pueden ecurrir lesiones personales.Antes de realizar cualquier trabajode mantenimiento o reparaci6n,desconecte la fuente de energia delcompreser y purgue toda la presi6n deaire.

    Para asegurar una operaci6n eficiente yuna vida Qtil m_s prolongada del com-presor de aire, debe prepararse y seguirseun programa de mantenimiento rutinario.El programa de mantenimiento rutinarioprecedente est_ diseSado para un equipoque funciona diariamente en un ambientenormal de trabajo. Si fuese necesario,debe modificarse el programa para adap-tarlo alas condiciones bajo las cuales seusa su compresor. Las modificacionesdepender_n de las horas de operaci6n ydel ambiente de trabajo. Los compresoresque funcionan en un ambiente sumamentesucio y/u hostil requeriran que hagantodas las inspecciones de mantenimientocon mayor frecuencia.NOTA: Vea en la secci6n "Operaci6n" laubicaci6n de los controles.

    COMO VERIFICAR LA VALVULA DE

    SEGURIDAD

    _ Riesgo deExplesi6n. Si

    la v;_lvula de seguridad no trabajaadecuadamente, ello petit& determinarla sobrepresibn del tanque, creando elriesgo de su ruptura o e×plosi6n.

    _ Riesgo de objetesdespedidos.

    Utilice siempre equipo de seguridadcertificado: anteojos de seguridad ANSI7_..87.1(CAN/CSA Z94.3) con pretecci6nlateral.

    Antes de poner en marcha el motor, tiredel anillo de la v_lvula de seguridad paraconfirmar la seguridad de que la mismaopera libremente, si la v_lvula quedase tra-bada o no trabajara c6modamente, deber_ser reemplazada por el mismo tipo dev_lvula.

    COMO DRENAR EL TANQUE

    Riesgo deoperacibn

    insegura. Riesgo per ruidos. Los tanquesde aire contienen aire de alta presi6n.Mantenga la cara y otras partes delcuerpo lejos de la salida del drenaje.Utilice anteojos de seguridad ANSIZ87.1(CAN/CSA Z94.3}, ya que al drenarse pueden desprender residues haciala eara. Utiliee protecei6n auditiva ANSIS12.6 (S3.19}, ya que el ruido del flujo deaire es alto durante el drenaje,

    39-SP 1000002920

  • 1. Coloque la palanca Auto/Off en laposici6n "Off".

    2. Tire de la perilla del regulador y gire ensentido contrario alas agujas de relopara establecer la salida de presi6n encero.

    3. Remueva la herramienta neumAtica oel accesorio.

    4. Tire del are de la valvula de seguri-dad dejando purgar el aire del tanquehasta que este reduzca su presi6naproximadamente a 20 PSI. Suelte elare de la vAIvula de seguridad.

    5. Drene el agua contenida en el tanquede aire, abriendo la vAIvula de drenajeubicada en la base del tanque (en sen-tido contrario alas agujas de reloj).

    se condensa dentro del tanque de aire.Si no se la drena, Io eorroer_ debilitandesus paredes, poniende en riesgo laruptura del tanque de aire.

    Riesge de da5o-- a la propiedad.Drene el agua del tanque de aire puedecontener aceite y 6xido, Io que puedeprovecar manchas,

    6. Una vez drenada el agua, cierre lav&lvula de drenaje (girando en sentidohorario). Ahora el compresor de airepodr_ ser guardado.

    NOTA: Si la vAIvula de drenaje fuera deltipo enchufe, elimine toda la presi6n deaire. La vAIvula podrA entonces ser extraida,limpiada y finalmente reinstalada.

    CONTROLAR EL ELEMENTO DELFILTRO DE AIRE

    Superficies-- calientes. Riesgode superficies calientes. El tube deenchufe, cabeza de la bomba, y laspiezas circundantes son muy eaiientes,no teca. Permita que el compreser serefresque antes del mantenimiento.

    1. AsegOrese de que el interruptorEncendido/Apagado (On/Off) est6 en laposici6n Apagado (Off).

    2. Permita que la unidad se frfo.3. Retire la cubierta del filtro de base.4. Retire el elemento de base del filtro.

    5. Ponga el nuevo elemento detrAs enbase del filtro. Compre las piezas derecambio de su distribuidor local ocentro de servicio autorizado. Utilicesiempre las piezas de recambioid6nticas.

    6. Cubierta rapida del filtro para filtrar labase.

    Riesgo de da_o-- a la propiedad.No opere la unidad sin el filtre de entradade aire.

    1000002920 40- SP

  • . _ = . L_ unidad ciclaautom_ticamente

    en cuanto la energia el_ctricaes conectada. AI efectuar elmantenimiento, usted quedar_ e×puestoa tensi6n viva, aire comprimido opartes en movimiento. Debido a talescircunstancias, podrian ocurrirlelesiones personales.

    Antes de dar servicio:o Desenchufe o desconecte el

    suministro el_ctrico al compresorde aire.

    , Purgue la presi6n del tanque., Deje enfriar al compreser de aire.

    TODO TIPO DE MANTENIMIENTOY OPERAClONES DE REPARAClONNO MENCIONADOS, DEBERAN SEREFECTUADOS POR PERSONALTECNICO ESPEClALIZADO.

    PARA REEMPLAZAR LA VALVULADE RETENCION

    1. Libere toda la presi6n del tanque deaire. Vea "C6mo Drenar el Tanque" enla secci6n Mantenimiento.

    2. Desenchufe el equipo.3. Quite la cubierta en el lateral del tubo

    de salida. NOTA: Quite el tomillo conun destomillador T-20 Torx y, antesde quitar la cubieC_a, afloje todas laslengQetas con un destomillador piano

    Con unaIlaveajustable,afloje latuerca deltubo desalida enel tanquede aire yel cabezalde labomba. Tubo aliviador de presi6n

    Retire cuidadosamente la tuberia desalida de la vAIvula de retenci6n.

    5. Usando una Ilave de tuercas ajustableafloje la tuerca de la tuberia de aliviode presi6n en el tanque de aire. Retirecuidadosamente la tuberia de alivio depresi6n de la vMvula de retenci6n.

    6. Desenrosque la v&lvula de retenci6ngir_ndola hacia la izquierda usandouna Ilave de boca de 7/8 pulg. Tomenota de la orientaci6n para volverla aensamblar.

    7. Usando un destomillador, empuje concuidado el disco de la v_lvula haciaarriba y hacia abajo.

    En posici6n _

    abierta nada esvisible

    En posi_

    el disco es visibie

    NOTA: El disco de la v_lvula debe moverselibremente hacia arriba y hacia abajo sobreun resoC_eque detiene el disco de la vMvulaen la posici6n cerrada. Si no Io hace, lavMvula de retenci6n necesita serreemplazada.8. Vuelva a instalar la vMvula de reten-

    ci6n (gire a la derecha).9. Vuelva a instalar la tuberia de alivio de

    presi6n. Apriete la tuerca.10. Vuelva a instalar la tuberia de salida y

    apriete las tuemas.11. Vuelva a colocar la cubieC(a.

    12. Ejecute el procedimiento de puestaen marcha. Vea "Procedimiento dePuesta en Marcha" en la secci6nOperaci6n.

    PARA REEMPLAZAR EL REGULADOR

    1. Libere toda la presi6n del aire deltanque. Vea "Drenaje del tanque" en lasecci6n Mantenimiento.

    2. Desenchufe el equipo.3. Retire las cubiertas.

    41-SP 1000002920

  • 4, Usando una Ilave de tuercas ajustableretire el medidor de salida de presi6n yla conexi6n rapida del regulador.

    Medidorde salida

    de presiSn

    5. Extraiga el regulador.6. Reaplique sellador de car_erias al

    manOmetro de presiOn externa y a laconexiOn rApida.

    7. Ensamble conector r&pido con elregulador nuevo y aprietan.

    Regulador ,s_,T_,_,, _-,_

    Nipi

    8. Aplique cinta selladora de ca5eriassobre el niple del tubo vedcical.

    9. Ensamble el regulador. NOTA: Laflecha indica el sentido del flujo delaire. AsegOrese que est8 apuntando ala direcci6n en la que fluye el aire.

    10. Utilice la tuerca hexagonal encendidoconector r_pido con el ajuste delregulador. Ori_ntelo de acuerdo a Iomostrado.

    11. Rearme el manOmetro de presi6n desalida y el conector r_pido. Oriente elman6metro de salida para permitir sulectura correctamente.

    12. Reponga la cubierta.

    Antes de guardar su compresor de aire,aseglJrese de hacer Io siguiente:1. Revise la secci6n "Mantenimiento" de

    las paginas precedentes y ejecute elmantenimiento programado de acu-erdo a la necesidad.

    2. Coloque la palanca Auto/Off en laposici6n "Off".

    3. Gire el regulador en sentido antiho-rario y fije la presi6n de salida en cero.

    4. Extraiga la herramienta neum_tica o elaccesorio.

    5. Tire del anillo de la v_lvula de segu-ridad permitiendo el purgado del airedel tanque hasta que la presi6n delmismo Ilegue aproximadamente a 20PSI. Suelte el anillo de la vAIvula deseguridad.

    6. Drene el agua del tanque de aireabriendo la vAIvula de drenaje ubicadaen el fondo del tanque.

    _EI agua secondensa dentrodel tanque de aire. Si no se drena, ellacorroer_ debilitando la paredes deltanque de aire, originande un rieego deruptura de sus paredes.

    7. Una vez que el agua haya sido dre-nada, cierre la v_lvula de drenaje.

    NOTA: Si la v_lvula de drenaje estuvieseenchufada, libere toda la presi6n de aire.La v_lvula podr_ ser extraida, limpiada yluego reinstalada.8. Para proteger el cord6n electrico

    contra da_os del viento, enr611eloenforma suelta alrededor del asa delcompresor.

    Almacene el compresor de aire en un sitiolimpio y seco.

    1000002920 42-SP

  • Riesgo de Operacibn Insegura. La unidad arrancaautom_ticamente cuando est_ enchufada. AI hacer el

    mantenimiento, el operador puede quedar e×puesto a fuentes de corriente y de airecomprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectarel compresor del tomacorriente, drenar la presi6n de aire del tanque y esperar a queel compresor se enfrie,

    PROBLEMA CAUSEA CORRECCION

    Presi6n excesiva El interrupter de presi6n no Mueva la palanca Auto/Off a ladel tanque interrumpe al motor cuando el 3osici6n "Off", si el equipo no- la v_lvula de compresor alcanza la presi6n corta, contacte a un tScnicoseguridad se "de corte", calificado para el servicio.dispara.

    El interrupter de presi6n "de Contacte a un t6cnico de serviciocorte" esta calibrado demasiado calificado.alto.

    Las conexiones Las conexiones de los tubes no Ajuste las conexiones en las quepierden aire. estAn suficientemente ajustadas el aire puede ser escuchado

    escapandose. Verifique lasconexiones con soluci6njabonosa y agua. NOSOBREAJUSTE.

    Compruebe si el asiento de lavAIvula estA dadado.

    Hay fugas de aireen la v_lvula deretenci6n o dentrode ella.

    P_rdida de pre- Un interrupter de presi6n defec-si6n de aire en el tuoso libera la vAIvula.

    interrupter de lav_lvula aliviadora.

    P6rdida de aire en Tanque de aire defectuoso.el tanque de aire oen las soldadurasdel tanque de aire.

    PSrdida de aire PSrdida en el sellado.entre el cabezal yel plato de v_lvula.

    Una v_lvula de retenci6ndefectuosa causa una fugaconstante de aire en la v_lvula

    de alivio de presi6n cuando hay_resi6n en el tanque y se apagael compresor. Reemplace lav_lvula de retenci6n. Consulte

    "C6mo Reemplazar la V_lvula deRetenci6n" en la secci6n Service

    y adjuste.

    Contacte a un tScnico calificadoen servicio.

    El tanque de aire debe serreemplazado. No repare la_erdida.

    _ Riesgo deE×plosi6n.

    No efect_e per{oraci6n algunasobre la soldadura o cesaseine]ante sobre el tanque deaire, ello Io debilitar_. El tanque_odria romperse o expletar.

    Contacte a un t6cnico calificadoen servicio.

    43-SP 1000002920

  • PR