trane product data upflow/horizontal right or …...2012/06/22 · upflow/horizontal right or...
TRANSCRIPT
Upflow/Horizontal Rightor Upflow/Horizontal LeftCondensing Gas Furnace
XT 90
PUB. NO. 22-1786-06
TDD-D-1
TUX1B040A9H21BTUX1B060A9H31BTUX1B080A9H31BTUX1C100A9H41BTUX1D120A9H51B
TDX1B040A9H21BTDX1B060A9H31BTDX1B080A9H31BTDX1C100A9H41BTDX1D120A9H51B
2 Pub. No. 22-1786-06
GeneralFeatures
© 2009 Trane All Rights Reserved
NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American and CanadianGas Association for both natural and L.P.gas. Limit setting and rating data wereestablished and approved under stan-dard rating conditions using AmericanNational Standards Institute standards.
SAFE OPERATIONThe Integrated System Control has solidstate devices, which continuously monitorfor presence of flame, when the system isin the heating mode of operation. Dualsolenoid combination gas valve andregulator provide extra safety.
QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide a positive dis-charge of gas fumes to the outside.
BURNERSMultiport Inshot burners will give years ofquiet and efficient service. All modelscan be converted to L.P. gas withoutchanging burners.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve, flamecontrol and includes self diagnostics forease of service. Also contains connec-tion points for E.A.C./humidifier.
AIR DELIVERYThe four speed, direct drive blowermotor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speeds ondemand from room thermostat. Theblower door safety switch will prevent orterminate furnace operation when theblower door is removed.
STYLINGHeavy gauge steel and “wrap-around”cabinet construction is used in thecabinet with baked-on enamel finish forstrength and beauty. The heat ex-changer section of the cabinet is com-pletely lined with foil faced fiberglassinsulation. This results in quiet andefficient operation due to the excellentacoustical and insulating qualities offiberglass. Built-in bottom pan andalternate bottom, left or right side returnair connection provision.
FEATURES ANDGENERAL OPERATIONThe XT90 High Efficiency Gas Furnacesemploy a Silicon Carbide Hot SurfaceIgnition system, which eliminates thewaste of a constant burning pilot. Theintegrated system control lights the mainburners upon a demand for heat from theroom thermostat. Complete front serviceaccess.
a. Low energy power venter
b. Vent proving pressure switch.
3Pub. No. 22-1786-06
Contents
General Features 2
Features and Benefits 4Standard Equipment 4Optional Equipment 4
General Data 5TUX1B040A9H21B 5TUX1B060A9H31B 5TUX1B080A9H31B 6TUX1C100A9H41B 6TUX1D120A9H51B 6TDX1B040A9H21B 7TDX1B060A9H31B 7TDX1B080A9H31B 7TDX1C100A9H41B 7TDX1D120A9H51B 8
Performance Data 10
Field Wiring 12
Dimensions 14
Electrical Data 15
4 Pub. No. 22-1786-06
Featuresand Benefits
XT 90 UPFLOW/HORIZONTAL RIGHT or LEFT STANDARD EQUIPMENT
XT90 Optional EquipmentOPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [✓✓✓✓✓] indicates accessories included).For Comfort Controls, See price book pages ................................................................................................................................ [ ]CleanEffectsTM Whole House Air Cleaner (14-1/2" Wide, Upflow / Side Return Furnace) ............................... TFD145ALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (17-1/2" Wide, Upflow / Side Return Furnace) ............................... TFD175ALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (21" Wide, Upflow / Side Return Furnace) ..................................... TFD210ALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (24-1/2" Wide, Upflow / Side Return Furnace) ............................... TFD245ALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (14-1/2" Wide, Downflow Furnace) ............................................... TFD14DALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (17-1/2" Wide, Downflow Furnace) ............................................... TFD17DALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (21" Wide, Downflow Furnace) ..................................................... TFD21DALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (24-1/2" Wide, Downflow Furnace) ............................................... TFD24DALFR000A [ ]Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ....................................................................... TFM145A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ....................................................................... TFM175A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................................. TFM210A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ....................................................................... TFM245A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ................................................................ TFP145A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................................................ TFP175A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ...................................................................... TFP210A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................................................ TFP245A9FR0 [ ]Coil Enclosure (14-1/2" Wide Cabinets) .......................................................................................................... BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) .......................................................................................................... BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) ................................................................................................................ BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) .......................................................................................................... BAYCLE24A2430A [ ]High Altitude Switch ................................................................................................................................................ BAYHALT248 [ ]Downflow Subbase ................................................................................................................................................. BAYBASE205 [ ]Propane Conversion Kit ........................................................................................................................................ BAYLPKT210B [ ]Propane Conversion Kit (With Stainless Steel burners) ......................................................................................... BAYLPSS210B [ ]Masonry Chimney Vent Kit .................................................................................................................................. BAYVENT800B [ ]Filter Access Door Kit (Downflow models) ............................................................................................................... BAYFLTR206 [ ]
• Convertible to horizontal with left orright airflow
• Power supply 115/1/60• Type 29-4CTM stainless steel
secondary heat exchanger
• Silicon Nitride Hot surface igniter withadaptive heat up
• Integrated solid state control with self-diagnostics
• Single wire twinning
• Attractive color accents
• Hinged blower door
• Prefect Fit door latches
• Insulated blower door
• Gasketed blower door
• Internal filter rack
• Standard filter sizes
• Cleanable high velocity filters
• Heavy gauge aluminized steel heatexchanger
• Blower door safety switch
• Multi-port In-shot burners
• Complete front service access
• Alternate bottom/left/right return air
• Slide out blower assembly
• Constant torque ECM blower motor
• Adjustable fan off times
• Common vent capability
• Heavy gauge reinforced wrap-aroundsteel cabinet
• Optional L.P. conversion kit
• Left/right gas connection
• Accessory hook-up capability
• Selectable cooling fan off eliminatesneed for BAY24X045 time delay relay
• 24 volt fuse
• Manual reset flame roll-out switches
5Pub. No. 22-1786-06
MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 55555R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".
PRODUCT SPECIFICATIONS 11111
TUX1B040A9H21BUpflow / Horizontal
40,00038,00092.1
30 - 60DIRECT10 x 7
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/55 - 3000115/1/60
1.0Yes
High Velocity1 - 17x25 - 1in.
2 Round
Aluminized Steel
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
2115/1/60
9.7151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
139 / 129
TUX1B060A9H31BUpflow / Horizontal
60,00056,000
92.130 - 60
DIRECT10 x 7
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/55- 3000115/1/60
1.0Yes
High Velocity1 - 17x25 - 1in.
2 Round
Aluminized Steel
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
3115/1/60
9.7151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
150 / 140
TUX1B080A9H31BUpflow / Horizontal
80,00074,000
92.135 - 65
DIRECT10 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/24 - 3200115/1/60
1.35Yes
High Velocity1 - 17x25 - 1in.
2 Round
Aluminized Steel
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
10.0151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
158 / 148
6 Pub. No. 22-1786-06
TUX1D120A9H51BUpflow / Horizontal
120,000112,000
92.140 - 70
DIRECT11 x 10
14
See Fan Performance Table1
1100115/1/60
CentrifugalDirect - 1
1/20- 3450115/1/60
.71Yes
High Velocity1 - 24x25 - 1in.
2.5 Round
Aluminized Steel
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
6115/1/60
14.5201/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
205 / 193
MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 55555R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
TUX1C100A9H41BUpflow / Horizontal
100,00093,00092.1
35 - 65DIRECT11 x 10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/20- 3450115/1/60
.71Yes
High Velocity1 - 20x25 - 1in.
2.5 Round
Aluminized Steel
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
12.4201/2
H x W x D41-3/4 x 23 x 30-1/2
171 / 162
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".
PRODUCT SPECIFICATIONS 11111
GeneralData
7Pub. No. 22-1786-06
GeneralData
MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 55555R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 11111
TDX1B040A9H21BDownflow / Horizontal
40,00038,000
91.030 - 60
DIRECT10 x 7
14
See Fan Performance Table1/2
1080115/1/60
CentrifugalDirect - 1
1/55- 3000115/1/60
1.14Yes
High Velocity1 - 14x20 - 1in.
2 Round
Aluminized Steel
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
2115/1/60
9.7151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
145 / 135
TDX1B060A9H31BDownflow / Horizontal
60,00056,00091.0
30 - 60DIRECT10 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/55- 3000115/1/60
1.0Yes
High Velocity2 - 14x20 - 1in.
2 Round
Aluminized Steel
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
3115/1/60
9.7151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
155 / 145
TDX1B080A9H31BDownflow / Horizontal
80,00074,000
91.035 - 65
DIRECT10 x8
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/25- 3200115/1/60
1.35Yes
High Velocity2 - 14x20 - 1in.
2 Round
Aluminized Steel
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
12.4151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
168 / 158
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".
8 Pub. No. 22-1786-06
MODELTYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP 55555R.P.M.Volts / Ph / HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)VENT PIPE DIAMETER— Min (in.)67
HEAT EXCHANGERType-Fired
-UnfiredGauge (Fired)ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V / Ph / Hz 44444Ampacity (In Amps)Max Overcurrent Protection (Amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 11111
TDX1C100A9H41BDownflow / Horizontal
100,00094,000
91.035 - 65
DIRECT11 x 10
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/20- 3450115/1/60
.71Yes
High Velocity2 - 16x20 - 1in.
2.5 Round
Aluminized Steel
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
12.4201/2
H x W x D41-3/4 x 23 x 30-1/2
185 / 175
TDX1D120A9H51BDownflow / Horizontal
120,000110,000
91.040 - 70
DIRECT11 x 10
14
See Fan Performance Table1
1075115/1/60
CentrifugalDirect - 1
1/20- 3450115/1/60
.71Yes
High Velocity2 - 16x20 - 1in.
2.5 Round
Aluminized Steel
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
6115/1/60
15.5201/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
206 / 196
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.5 Constant torque ECM blower motor.6 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length labelon the furnace.7 All *UX1 and *DX1 furnace models have a vent outlet diameter that equals 2".
GeneralData
9Pub. No. 22-1786-06
PerformanceData
* May be "A" or "T"
FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins.w.g.)
MODEL SPEED TAP 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
*UX1B040A9H21B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
1159938844772
1131910814732
1102881783691
1077851750656
1052820717621
1022786681581
992751645540
961717604497
930662563454
*UX1B060A9H31B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
135811961025863
132711661000830
12961135975797
1272-1109943762
12481082910726
12151053878687
11821023845648
1122989813601
1061955780554
*UX1B080A9H31B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
1436133412391160
1404130812091131
1371128111791101
1346125011491070
1320121911191039
1289119310901007
125711671060974
121411321030940
11701097999905
*UX1C100A9H41B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
1888175115301245
1852171514911204
1815167914521162
1776164314151115
1737160613781067
1698157113361023
165915361293979
162614931253931
159314501212882
*UX1D120A9H51B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
2153189517771618
2121185617431579
2089181717081540
2056177916731504
2023174116371467
1983170816011430
1943167415641393
1907163415241354
1870159314841315
*DX1B040A9H21B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
1156935835752
1128859803726
1100859771700
1072828736648
1043797701596
1012757652554
981717602511
917679569471
852641536431
*DX1B060A9H31B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
13371159967863
13141127930823
12911094893782
12571065856742
12231036818702
1187997774657
1150957729611
1090920690571
1030883651531
*DX1B080A9H31B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
161413221098970
158512951067934
155512671036898
148912391003868
14231211970837
13631180933794
13031149896750
12021111864712
11011072831674
*DX1C100A9H41B
NOTE: Do NOT use theLOW speed tap for heating
4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
1844174814291203
1808171613921134
1771168313541124
1736164813121077
1700161212691029
166915741235983
163815351200937
159014971154887
154214591108837
*DX1D120A9H51B 4 - HIGH - Black3 - MED-HIGH - Blue2 - MED-LOW - Yellow1 - LOW - Red
2162192817821552
2127188817431520
2091184817031488
2049181116651450
2006177416261412
1964173615821370
1922169815371328
1849165315001295
1775160714621261
10 Pub. No. 22-1786-06
PerformanceData
* May be "A" or "T"
CFM VS. TEMPERATURE RISE
MODELCFM (CUBIC FEET PER MINUTE)
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100
*UX1B040A9H21B 56 48 42 37 33 30
*UX1B060A9H31B 63 56 50 45 42 38 36 33 31 29
*UX1B080A9H31B 67 61 56 51 48 44 42 39 37 35
*UX1C100A9H41B 64 60 56 52 49 46 44 42 40
*UX1D120A9H51B 71 67 63 59 56 53 50 48
CFM VS. TEMPERATURE RISE
MODEL CFM (CUBIC FEET PER MINUTE)
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100
*DX1B040A9H21B 56 48 42 37 33 30
*DX1B060A9H31B 63 56 50 45 42 38 36 33 31 29
*DX1B080A9H31B 67 61 56 51 48 44 42 39 37 35
*DX1C100A9H41B 64 60 56 52 49 46 44 42 40
*DX1D120A9H51B 71 67 63 59 56 53 50 48
* May be "A" or "T"
11Pub. No. 22-1786-06
FieldWiring
OUTDOOR UNIT (NO TRANSFORMER)
SEE NOTE 6
From Dwg. B340388 Rev. 2
SEE NOTE 8
FURNACE
B/CB/C
TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING, 1 STAGE COOLING
USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)
SEE NOTE 6
From Dwg. B341437 Rev. 1
FURNACE
TWIN
SEE NOTE 7
B/CB/C TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES
HUM SEENOTE 5
EAC SEENOTE 5
FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING
USING A 1 STAGE HEATING THERMOSTATNO COOLING
12 Pub. No. 22-1786-06
Twinning
TWIN TWIN
R1 R1
TWINNING CONNECTION DIAGRAMFOR TWINNING 1 STAGE FURNACES WITH
SINGLE WIRE TWINNING FEATURE1 STAGE HEATING ONLY THERMOSTAT1 STAGE HEAT
ONLYTHERMOSTAT
(WITH FAN SWITCH) FURNACE NO. 1 FURNACE NO. 2
BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZEDWITH UNIT NO. 1 VIA SIGNALS
FROM TWIN CONNECTION.
SEE NOTE 4
SEE NOTE 3
ISOLATION RELAY(FIELD SUPPLIED)
SEE NOTE 4
ISOLATION RELAYSEE NOTE 4
B/CB/CB/C
From Dwg. 21B341422 Rev. 3
TWIN TWIN
R1
R1
TWINNING CONNECTION DIAGRAMFOR TWINNING 1 STAGE FURNACES WITH
SINGLE WIRE TWINNING FEATURE1 STAGE HEAT / 1 STAGE COOL THERMOSTAT
1 STAGEHEATING / COOLING
THERMOSTAT FURNACE NO. 1 FURNACE NO. 2
BLOWER OPERATION OF UNIT NO. 2 IS SYNCRONIZEDWITH UNIT NO. 1 VIA SIGNALS
FROM TWIN CONNECTION.
SEE NOTE 4
SEE NOTE 5
ISOLATION RELAY(FIELD SUPPLIED)
SEE NOTE 4
ISOLATION RELAYSEE NOTE 4
OUTDOOR UNIT(NO TRANSFORMER)
OUTDOOR UNIT(WITH TRANSFORMER)
RC
ISOLATION RELAY(FIELD SUPPLIED)
SEE NOTE 3
B/CB/CB/C
From Dwg. 21B341423 Rev. 2
13Pub. No. 22-1786-06
Dimensions
TUX
1-H
OU
TLIN
E D
RA
WIN
G(A
LL
DIM
EN
SIO
NS
AR
E IN
INC
HE
S)
14 Pub. No. 22-1786-06
TDX
1-H
OU
TLIN
E D
RA
WIN
G(A
LL
DIM
EN
SIO
NS
AR
E IN
INC
HE
S)
Dimensions
15
Pub. No. 22-1786-06
TUX1-H Wiring Diagram For Gas Furnaces
16
Pub. No. 22-1786-06
TUX1-H Schematic Diagram For Gas Furnaces
17
Pub. No. 22-1786-06
TDX1-H Wiring Diagram For Gas Furnaces
18
Pub. No. 22-1786-06
TDX1-H Schematic Diagram For Gas Furnaces
19
Pub. No. 22-1786-06
Notes
Since Trane has a policy of continuous product and product data improvement, it reserves the right tochange design and specifications without notice.
Trane6200 Troup HighwayTyler, TX 75707www.trane.com
LibraryProduct SectionProductModelLiterature TypeSequenceDateFile No.Supersedes
UnitaryFurnacesFurnaceTUX1-HProduct Data-06/1022-1786-0622-1786-05