Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TUE1A040A9241A, TUE1A060A9241A, TUE1A060A9361A TUE1B060A9361A, TUE1B080A9361A, TUE1B080A9481A TUE1B100A9361A, TUE1C100A9481A, TUE1C100A9601A TUE1D120A9601A, TUE1D140A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1666-08

Upload: buinhan

Post on 16-Mar-2018

229 views

Category:

Documents


5 download

TRANSCRIPT

Upflow/Horizontal Right or Upflow/Horizontal Left

Induced Draft Gas Furnace

XB 80TUE1A040A9241A, TUE1A060A9241A, TUE1A060A9361ATUE1B060A9361A, TUE1B080A9361A, TUE1B080A9481ATUE1B100A9361A, TUE1C100A9481A, TUE1C100A9601ATUE1D120A9601A, TUE1D140A9601ASingle-Stage Fan Assisted Combustion System

PUB. NO. 22-1666-08

2 Pub. No. 22-1666-08

GeneralFeatures

© Trane 2012

NATURAL GAS MODELSCentral Heating furnace designs are certified by the American Gas Associa-tion for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.

SAFE OPERATIONThe Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of opera-tion. Dual solenoid combination gas valve and regulator provide extra safety.

QUICK HEATINGDurable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure.

BURNERSMultiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.

INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.

AIR DELIVERYThe 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.

STYLINGHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchang-er section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera-tion due to the excellent acoustical and insulating qualities of fiberglass. Alter-nate bottom, left or right side return air connection provision capability.

FEATURES AND GENERAL OPERATIONThe XB 80 High Efficiency Gas Fur-naces employs an Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.

a. Low energy power venter b. Vent proving pressure switch.

3Pub. No. 22-1666-08

Contents

Feature Summary

Features and Benefits Standard EquipmentOptional Equipment

General Data TUE1A040A9241ATUE1A060A9241ATUE1A060A9361ATUE1B060A9361ATUE1B080A9361ATUE1B080A9481ATUE1B100A9361ATUE1C100A9481ATUE1C100A9601ATUE1D120A9601ATUE1D140A9601A

Performance Data

Electrical Data

Field Wiring

Dimensions

2

4

6

9

11

14

17

4 Pub. No. 22-1666-08

XB 80 STANDARD EQUIPMENT• Convertibletohorizontalleftorright

• Powersupply115/1/60

• Singlespeedventer

• Silicon Nitride hot surface igniter with adaptive heat up

• Integratedsystemcontrol

• Attractivecoloraccents

• Heavygaugealuminizedsteelheatexchanger

Featuresand Benefits

• Directdrive4-speedmotor

• Blowerdoorsafetyswitch

• MultiportIn-shotburners

• Completefrontserviceaccess

• Alternatebottom/left/rightreturnairinvertical position

• Slideoutblowerassembly

• Commonventcapability

• Heavygaugereinforcedwrap-aroundsteel cabinet

• Superquietperformance

• OptionalL.P.conversionkit

• Left/rightgasconnection

5Pub. No. 22-1666-08

Featuresand Benefits

ACCESSORIES FOR XB 80

OPTIONAL EQUIPMENT (Check mark [✓] indicates accessories included).For Comfort Controls, See price book pages .............................................................................................................................. [ ]CleanEffectsTM Whole House Air Cleaner (14-1/2" Wide, Upflow / Side Return Furnace) ........................... TFD145ALFR000A[ ]CleanEffectsTM Whole House Air Cleaner (17-1/2" Wide, Upflow / Side Return Furnace) ........................... TFD175ALFR000A[ ]CleanEffectsTM Whole House Air Cleaner (21" Wide, Upflow / Side Return Furnace) .................................. TFD210ALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (24-1/2" Wide, Upflow / Side Return Furnace) ........................... TFD245ALFR000A[ ]CleanEffectsTM Whole House Air Cleaner (14-1/2" Wide, Downflow Furnace) .............................................TFD14DALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (17-1/2" Wide, Downflow Furnace) .............................................TFD17DALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (21" Wide, Downflow Furnace) ...................................................TFD21DALFR000A [ ]CleanEffectsTM Whole House Air Cleaner (24-1/2" Wide, Downflow Furnace) .............................................TFD24DALFR000A [ ]Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .................................................................... TFM145A9FR0[ ]Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .................................................................... TFM175A9FR0[ ]Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ........................................................................... TFM210A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .................................................................... TFM245A9FR0[ ]Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..............................................................TFP145A9FR0[ ]Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..............................................................TFP175A9FR0[ ]Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ....................................................................TFP210A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..............................................................TFP245A9FR0[ ]Coil Enclosure (14-1/2" Wide Cabinets) ........................................................................................................ BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ........................................................................................................ BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ........................................................................................................ BAYCLE24A2430A [ ]Filter Rack Kit ......................................................................................................................................................BAYRACK960A [ ]High Altitude Switch ................................................................................................................................................ BAYHALT248 [ ]Downflow Subbase .................................................................................................................................................BAYBASE205[ ]Propane Conversion Kit ........................................................................................................................................BAYLPKT210B [ ]Propane Conversion Kit (With Stainless Steel burners) .......................................................................................BAYLPSS210B [ ]Masonry Chimney Vent Kit .................................................................................................................................. BAYVENT800B [ ]CleanableFilter(14.5"/17.5"wideupflowmodels) ................................................................................................BAYFLTR317 [ ]Cleanable Filter (21" wide upflow models) ..............................................................................................................BAYFLTR321 [ ]CleanableFilter(24.5"wideupflowmodels) ...........................................................................................................BAYFLTR324 [ ]Filter Access Door Kit (Downflow models only) .......................................................................................................BAYFLTR206 [ ]

6 Pub. No. 22-1666-08

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

GeneralData

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TUE1A040A9241A

Upflow / Horizontal

40,00031,00080.0

30 - 60

Direct10 x 6

14

See Fan Performance Table1/5

1080115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 16x25 - 1in.

4 Round

Alum. Steel-

20

2 — 452 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot2

115/1/605.415

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

119 / 110

TUE1B060A9361A

Upflow / Horizontal

60,00047,00080.0

30 - 60

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 16x25 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/609.015

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

137 / 127

TUE1A060A9361A

Upflow / Horizontal

60,00047,00080.0

30 - 60

Direct10 x 6

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 16x25 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/609.015

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

127 / 118

TUE1A060A9241A

Upflow / Horizontal

60,00047,00080.0

35 - 65

Direct10 x 6

14

See Fan Performance Table1/5

1080115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/605.415

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

124 / 115

7Pub. No. 22-1666-08

GeneralData

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TUE1B080A9361A

Upflow / Horizontal

80,00063,00080.0

30 - 60

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot4

115/1/609.015

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

142 / 132

TUE1B080A9481A

Upflow / Horizontal

80,00064,00080.0

30 - 60

Direct10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot4

115/1/609.815

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

142 / 132

TUE1C100A9481A

Upflow / Horizontal

100,00079,00080.0

35 - 65

Direct10 x 8

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 20x25 - 1in.

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/6011.615

1/2

H x W x D41-3/4 x 23 x 30-1/2

162 / 151

TUE1B100A9361A

Upflow / Horizontal

100,00079,00080.0

40 - 70

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/609.015

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

151 / 141

8 Pub. No. 22-1666-08

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

TUE1D120A9601A

Upflow / Horizontal

120,00096,00080.0

30 - 60

Direct11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 24x25 - 1in.

4 Round

Alum. Steel

20

6 — 456 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot6

115/1/6013.420

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

186 / 174

TUE1C100A9601A

Upflow / Horizontal

100,00079,00080.0

30 - 60

Direct11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 20x25 - 1in.

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/6013.415

1/2

H x W x D41-3/4 x 23 x 30-1/2

162 / 151

TUE1D140A9601A

Upflow / Horizontal

140,000111,000

80.040 - 70

DIRECT11 x 10

14

See Fan Performance Table3/4

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 24x25 - 1in.

4 Round

Alum. Steel

20

7 — 457 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot7

115/1/6013.820

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

193 / 181

GeneralData

9Pub. No. 22-1666-08

PerformanceData

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.)MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

TUE1A040A9241A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1018847716617

1004832701599

982809678575

950779648544

910742610507

860697585463

802644512413

763585452357

660517384294

TUE1A060A9241A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1018835712611

997821702596

973800683573

941771655543

901734617505

852689571459

796636516406

731575452345

659506379277

TUE1A060A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

142612431042900

138912251039903

134511971027895

129811601005877

12361113973848

11711057931809

1099991879760

1020916817700

934831745629

TUE1B060A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

142612431042900

138912251039903

134511971027895

129811601005877

12361113973848

11711057931809

1099991879760

1020916817700

934831745629

TUE1B080A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

139312101046900

138412091052903

136411981047895

133511771033888

129611471008869

12471107973842

11891058928808

1120999873766

1042930808717

TUE1B100A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

147612491020873

146412571046887

144112521058890

140812341050883

136312031028864

13071158990834

12411101936794

11631030866742

1074946780680

TUE1B080A9481A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

183913231092788

182113251090783

179613291091780

175613191083768

171013081076758

164112751059737

157312461040719

148012011005674

13921165970630

TUE1C100A9481A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1880166214281208

1846163514211215

1799159814021210

1740155113701193

1669149313261164

1595142412691124

1489134511991073

1381125611171009

126011571022935

TUE1C100A9601A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2181190816211443

2143188816091419

2104186815971395

2053183415821381

2001180015671367

1929174515331335

1856169014981302

1766 1631 1438 1256

1676157213771209

TUE1D120A9601A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2135190616461423

2101188116321415

2066185616171407

2036181715961391

2005177715751375

1923172415351338

1840167114941300

1750160214271246

1659153313601192

TUE1D140A9601A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2462212817551450

2407211217461446

2351209617361442

2284205417191427

2216201117021411

2143194916561383

2069188716091354

1989179715641298

1908170615181241

From D330672 Rev. 17

10 Pub. No. 22-1666-08

PerformanceData

CFM VS. TEMPERATURE RISE

MODEL CFM (CUBIC FEET PER MINUTE)500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

TUE1A040A9241A 54 49 42 37 33 30TUE1A060A9241A 63 56 49 44TUE1A060A9361A 56 49 44 40 37 34 32TUE1B060A9361A 56 49 44 40 37 34 32TUE1B080A9361A 59 54 49 46 42TUE1B100A9361A 58 52 49 46 42 40 37 35 33TUE1B080A9481A 67 62 57 53 49TUE1C100A9481A 67 62 57 53 49 46 44 41 39 37TUE1C100A9601A 62 57 53 49 46 44 41 39 37 35 34 32 31TUE1D120A9601A 59 56 52 49 47 44 42 40TUE1D140A9601A 69 65 61 58 55 52 49 47 45

From C340782 Sh.1 Rev. 8

11Pub. No. 22-1666-08

WIRING DIAGRAM FOR TUE1 GAS FURNACES

Field Wiring

From Dwg. D342779

12 Pub. No. 22-1666-08

SCHEMATIC DIAGRAMS FOR GAS FURNACES

Field Wiring

From Dwg. D342779

13Pub. No. 22-1666-08

Field Wiring

SEE NOTE 5

From drawing B342026 Rv 0

FURNACE

SEE NOTE 6

B/CB/C

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING

USING A 1 STAGE HEATING THERMOSTATNO COOLING

OUTDOOR UNIT (NO TRANSFORMER)

SEE NOTE 5

From drawing B342023 Rv 0

FURNACE

B/CB/C

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING, 1 STAGE COOLING

USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR HEATING ONLY

14 Pub. No. 22-1666-08

Dimensions

TUE1 OUTLINE DRAWING(ALL DIMENSIONS ARE IN INCHES)

From Dwg. 21C340781 Rev. 13

MODEL A BD

TUE1A040A9241ATUE1A060A9241ATUE1A060A9361A

14-1/2" 9-5/8" 13-1/4" 13"

TUE1B060A9361ATUE1B080A9361ATUE1B080A9481ATUE1B100A9361A

17-1/2" 9-5/8" 16-1/4" 16"

TUE1C100A9481ATUE1C100A9601A

21" 13-1/16" 19-3/4" 19-1/2"

TUE1D120A9601ATUE1D140A9601A

24-1/2" 15-5/16" 23-1/4" 23"

15Pub. No. 22-1666-08

Notes

Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.