american standard upflow/horizontal right or upflow...

16
Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace American Standard 80 Furnace AUE1A040A9241A, AUE1A060A9241A, AUE1A060A9361A AUE1B060A9361A, AUE1B080A9361A, AUE1B080A9481A AUE1B100A9361A, AUE1C100A9481A, AUE1C100A9601A AUE1D120A9601A, AUE1D140A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 12-1236-04

Upload: others

Post on 17-Jul-2020

26 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

Upflow/Horizontal Right or Upflow/Horizontal Left

Induced Draft Gas Furnace

American Standard 80 FurnaceAUE1A040A9241A, AUE1A060A9241A, AUE1A060A9361AAUE1B060A9361A, AUE1B080A9361A, AUE1B080A9481AAUE1B100A9361A, AUE1C100A9481A, AUE1C100A9601AAUE1D120A9601A, AUE1D140A9601ASingle-Stage Fan Assisted Combustion System

PUB. NO. 12-1236-04

Page 2: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

2 Pub. No. 12-1236-04

GeneralFeatures

© 2012 American Standard Heating & Air Conditioning

NATURAL GAS MODELSCentral Heating furnace designs are certified by the American Gas Associa-tion for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.

SAFE OPERATIONThe Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of opera-tion. Dual solenoid combination gas valve and regulator provide extra safety.

QUICK HEATINGDurable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure.

BURNERSMultiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.

INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.

AIR DELIVERYThe 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.

STYLINGHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchang-er section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera-tion due to the excellent acoustical and insulating qualities of fiberglass. Alter-nate bottom, left or right side return air connection provision capability.

FEATURES AND GENERAL OPERATIONThe American Standard 80 Gas Fur-naces employs an Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.

a. Low energy power venter b. Vent proving pressure switch.

Page 3: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

3Pub. No. 12-1236-04

Contents

Feature Summary

Features and Benefits Standard EquipmentOptional Equipment

General Data AUE1A040A9241AAUE1A060A9241AAUE1A060A9361AAUE1B060A9361AAUE1B080A9361AAUE1B080A9481AAUE1B100A9361AAUE1C100A9481AAUE1C100A9601AAUE1D120A9601AAUE1D140A9601A

Performance Data

Electrical Data

Field Wiring

Dimensions

2

4

5

8

10

12

13

Page 4: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

4 Pub. No. 12-1236-04

• Convertibletohorizontalleftorright

• Powersupply115/1/60

• Singlespeedventer

• Silicon Nitride hot surface igniter with adaptive heat up

• Integratedsystemcontrol

• Attractivecoloraccents

Featuresand Benefits

• Heavygaugealuminizedsteelheatexchanger

• Directdrive4-speedmotor

• Blowerdoorsafetyswitch

• MultiportIn-shotburners

• Completefrontserviceaccess

• Alternatebottom/left/rightreturnairinvertical position

OPTIONAL EQUIPMENT (Check mark [✓] indicates accessories included).For Comfort Controls, See price book pages .............................................................................................................................. [ ]AccuCleanTM Whole House Air Cleaner (14-1/2" Wide, Upflow / Side Return Furnace) ............................... AFD145ALFR000A[ ]AccuCleanTM Whole House Air Cleaner (17-1/2" Wide, Upflow / Side Return Furnace) ............................... AFD175ALFR000A[ ]AccuCleanTM Whole House Air Cleaner (21" Wide, Upflow / Side Return Furnace) ..................................... AFD210ALFR000A [ ]AccuCleanTM Whole House Air Cleaner (24-1/2" Wide, Upflow / Side Return Furnace) ............................... AFD245ALFR000A[ ]AccuCleanTM Whole House Air Cleaner (14-1/2" Wide, Downflow Furnace) ................................................AFD14DALFR000A [ ]AccuCleanTM Whole House Air Cleaner (17-1/2" Wide, Downflow Furnace) ................................................AFD17DALFR000A [ ]AccuCleanTM Whole House Air Cleaner (21" Wide, Downflow Furnace) ......................................................AFD21DALFR000A [ ]AccuCleanTM Whole House Air Cleaner (24-1/2" Wide, Downflow Furnace) ................................................AFD24DALFR000A [ ]Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .................................................................... TFM145A9FR0[ ]Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .................................................................... TFM175A9FR0[ ]Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ........................................................................... TFM210A9FR0 [ ]Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .................................................................... TFM245A9FR0[ ]Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..............................................................TFP145A9FR0[ ]Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..............................................................TFP175A9FR0[ ]Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ....................................................................TFP210A9FR0 [ ]Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..............................................................TFP245A9FR0[ ]Coil Enclosure (14-1/2" Wide Cabinets) ........................................................................................................ BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ........................................................................................................ BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .............................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ........................................................................................................ BAYCLE24A2430A [ ]Filter Rack Kit ......................................................................................................................................................BAYRACK960A [ ]High Altitude Switch ................................................................................................................................................ BAYHALT248 [ ]Downflow Subbase .................................................................................................................................................BAYBASE205[ ]Propane Conversion Kit ........................................................................................................................................BAYLPKT210B [ ]Propane Conversion Kit (With Stainless Steel burners) .......................................................................................BAYLPSS210B [ ]Masonry Chimney Vent Kit (Upflow models only) ................................................................................................ BAYVENT800B [ ]CleanableFilter(14.5"/17.5"wideupflowmodels) ................................................................................................BAYFLTR317 [ ]Cleanable Filter (21" wide upflow models) ..............................................................................................................BAYFLTR321 [ ]CleanableFilter(24.5"wideupflowmodels) ...........................................................................................................BAYFLTR324 [ ]Filter Access Door Kit (Downflow models only) .......................................................................................................BAYFLTR206 [ ]

80 FURNACE OPTIONAL ACCESSORIES

80 FURNACE STANDARD EQUIPMENT

• Slideoutblowerassembly

• Commonventcapability

• Heavygaugereinforcedwrap-aroundsteel cabinet

• Superquietperformance

• OptionalL.P.conversionkit

• Left/rightgasconnection

Page 5: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

5Pub. No. 12-1236-04

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

GeneralData

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

AUE1A040A9241A

Upflow / Horizontal

40,00031,00080.0

30 - 60

Direct10 x 6

14

See Fan Performance Table1/5

1080115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 16x25 - 1in.

4 Round

Alum. Steel-

20

2 — 452 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot2

115/1/605.415

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

119 / 110

AUE1B060A9361A

Upflow / Horizontal

60,00047,00080.0

30 - 60

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 16x25 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/609.015

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

137 / 127

AUE1A060A9361A

Upflow / Horizontal

60,00047,00080.0

30 - 60

Direct10 x 6

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 16x25 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/609.015

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

127 / 118

AUE1A060A9241A

Upflow / Horizontal

60,00047,00080.0

35 - 65

Direct10 x 6

14

See Fan Performance Table1/5

1080115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

3 — 453 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot3

115/1/605.415

1/2

H x W x D41-3/4 x 16-1/2 x 30-1/2

124 / 115

Page 6: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

6 Pub. No. 12-1236-04

GeneralData

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

AUE1B080A9361A

Upflow / Horizontal

80,00063,00080.0

30 - 60

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot4

115/1/609.015

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

142 / 132

AUE1B080A9481A

Upflow / Horizontal

80,00064,00080.0

30 - 60

Direct10 x 8

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

4 — 454 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot4

115/1/609.815

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

142 / 132

AUE1C100A9481A

Upflow / Horizontal

100,00079,00080.0

35 - 65

Direct10 x 8

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 20x25 - 1in.

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/6011.615

1/2

H x W x D41-3/4 x 23 x 30-1/2

162 / 151

AUE1B100A9361A

Upflow / Horizontal

100,00079,00080.0

40 - 70

Direct10 x 7

14

See Fan Performance Table1/3

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 17x25 - 1in.

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/609.015

1/2

H x W x D41-3/4 x 19-1/2 x 30-1/2

151 / 141

Page 7: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

7Pub. No. 12-1236-04

PRODUCT SPECIFICATIONS 1MODEL

TYPE

RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F.

BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz

COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA

FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

VENT — Size (in.)

HEAT EXCHANGERType -Fired -UnfiredGauge (Fired)

ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size

GAS VALVE

PILOT SAFETY DEVICEType

BURNERS — TypeNumber

POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)

PIPE CONN. SIZE (IN.)

DIMENSIONSCrated (In.)

WEIGHTShipping (Lbs.) / Net (Lbs)

1 Central Furnace heating designs are certified to ANSI Z21.47 and CSA 2.3.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian

applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

AUE1D120A9601A

Upflow / Horizontal

120,00096,00080.0

30 - 60

Direct11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 24x25 - 1in.

4 Round

Alum. Steel

20

6 — 456 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot6

115/1/6013.420

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

186 / 174

AUE1C100A9601A

Upflow / Horizontal

100,00079,00080.0

30 - 60

Direct11 x 10

14

See Fan Performance Table1/2

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 20x25 - 1in.

4 Round

Alum. Steel

20

5 — 455 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot5

115/1/6013.415

1/2

H x W x D41-3/4 x 23 x 30-1/2

162 / 151

AUE1D140A9601A

Upflow / Horizontal

140,000111,000

80.040 - 70

DIRECT11 x 10

14

See Fan Performance Table3/4

1075115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09

NoHigh Velocity

1 - 24x25 - 1in.

4 Round

Alum. Steel

20

7 — 457 — 56

Redundant - Single Stage

Hot Surface Ignition

Multiport Inshot7

115/1/6013.820

1/2

H x W x D41-3/4 x 26-1/2 x 30-1/2

193 / 181

GeneralData

Page 8: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

8 Pub. No. 12-1236-04

PerformanceData

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.)MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

AUE1A040A9241A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1018847716617

1004832701599

982809678575

950779648544

910742610507

860697585463

802644512413

763585452357

660517384294

AUE1A060A9241A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1018835712611

997821702596

973800683573

941771655543

901734617505

852689571459

796636516406

731575452345

659506379277

AUE1A060A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

142612431042900

138912251039903

134511971027895

129811601005877

12361113973848

11711057931809

1099991879760

1020916817700

934831745629

AUE1B060A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

142612431042900

138912251039903

134511971027895

129811601005877

12361113973848

11711057931809

1099991879760

1020916817700

934831745629

AUE1B080A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

139312101046900

138412091052903

136411981047895

133511771033888

129611471008869

12471107973842

11891058928808

1120999873766

1042930808717

AUE1B100A9361A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

147612491020873

146412571046887

144112521058890

140812341050883

136312031028864

13071158990834

12411101936794

11631030866742

1074946780680

AUE1B080A9481A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

183913231092788

182113251090783

179613291091780

175613191083768

171013081076758

164112751059737

157312461040719

148012011005674

13921165970630

AUE1C100A9481A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1880166214281208

1846163514211215

1799159814021210

1740155113701193

1669149313261164

1595142412691124

1489134511991073

1381125611171009

126011571022935

AUE1C100A9601A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2181190816211443

2143188816091419

2104186815971395

2053183415821381

2001180015671367

1929174515331335

1856169014981302

1766 1631 1438 1256

1676157213771209

AUE1D120A9601A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2135190616461423

2101188116321415

2066185616171407

2036181715961391

2005177715751375

1923172415351338

1840167114941300

1750160214271246

1659153313601192

AUE1D140A9601A

4 - 3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

2462212817551450

2407211217461446

2351209617361442

2284205417191427

2216201117021411

2143194916561383

2069188716091354

1989179715641298

1908170615181241

From D330672 Rev. 17

Page 9: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

9Pub. No. 12-1236-04

PerformanceData

CFM VS. TEMPERATURE RISE

MODEL CFM (CUBIC FEET PER MINUTE)500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400

AUE1A040A9241A 54 49 42 37 33 30AUE1A060A9241A 63 56 49 44AUE1A060A9361A 56 49 44 40 37 34 32AUE1B060A9361A 56 49 44 40 37 34 32AUE1B080A9361A 59 54 49 46 42AUE1B100A9361A 58 52 49 46 42 40 37 35 33AUE1B080A9481A 67 62 57 53 49AUE1C100A9481A 67 62 57 53 49 46 44 41 39 37AUE1C100A9601A 62 57 53 49 46 44 41 39 37 35 34 32 31AUE1D120A9601A 59 56 52 49 47 44 42 40AUE1D140A9601A 69 65 61 58 55 52 49 47 45

From C340782 Sh.1 Rev. 8

Page 10: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

10 Pub. No. 12-1236-04

WIRING DIAGRAM FOR AUE1 GAS FURNACES

Field Wiring

From Dwg. D342779

Page 11: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

11Pub. No. 12-1236-04

SCHEMATIC DIAGRAMS FOR AUE1 GAS FURNACES

Field Wiring

From Dwg. D342779

Page 12: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

12 Pub. No. 12-1236-04

Field Wiring

SEE NOTE 5

From drawing B342026 Rv 0

FURNACE

SEE NOTE 6

B/CB/C

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING

USING A 1 STAGE HEATING THERMOSTATNO COOLING

OUTDOOR UNIT (NO TRANSFORMER)

SEE NOTE 5

From drawing B342023 Rv 0

FURNACE

B/CB/C

TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODES

FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE1 STAGE HEATING, 1 STAGE COOLING

USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT(OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER)

FIELD WIRING DIAGRAM FOR HEATING ONLY

Page 13: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

13Pub. No. 12-1236-04

Dimensions

AUE1 OUTLINE DRAWING(ALL DIMENSIONS ARE IN INCHES)

From Dwg. 21C340781 Rev. 13

MODEL A B C D

AUE1A040A9241AAUE1A060A9241AAUE1A060A9361A

14-1/2" 9-5/8" 13-1/4" 13"

AUE1B060A9361AAUE1B080A9361AAUE1B080A9481AAUE1B100A9361A

17-1/2" 9-5/8" 16-1/4" 16"

AUE1C100A9481AAUE1C100A9601A

21" 13-1/16" 19-3/4" 19-1/2"

AUE1D120A9601AAUE1D140A9601A

24-1/2" 15-5/16" 23-1/4" 23"

Page 14: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

14 Pub. No. 12-1236-04

Notes

Page 15: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

15Pub. No. 12-1236-04

Notes

Page 16: American Standard Upflow/Horizontal Right or Upflow ...hstrial-freedomheating.homestead.com/AUE1.pdf · Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated

Since American Standard Heating & Air Conditioning has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.

American StandardHeating & Air Conditioning6200 Troup HighwayTyler, TX 75707

06/12