INTERCOM SYSTEM Central Control Unit TOA ELECTRIC CO., LTD. KOBE, JAPAN TOA EXES-1 000 INTERCOM SYSTEM CCU-11B INSTALLATION HAND BOOK 133-21-012-7A

Upload: others

Post on 19-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

INTERCOM SYSTEM

Central Control Unit

TOA ELECTRIC CO., LTD.KOBE, JAPAN

TOA EXES-1000 INTERCOM SYSTEM

CCU-11B

INSTALLATION HAND BOOK

133-21-012-7A

Page 2: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

CONTENTS

Page

1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2. Functions which Require Additional Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3. Precautions for Installation of CCU-11B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

5. DIP Switch for Function Selection on CCU-11 B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

6. Station No. 11 Programming for Each Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

7. Remote Control Relay (RY1 & RY2) on CCU-11B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7-1 Functions and Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

7-2 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

8. Programming List for Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

4. Initial CCU-11B Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

— 1 —— —

.

Page 3: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

1. INTRODUCTION

This manual forms part of the Installation Manual for

TOA INTERCOM SYSTEM EXES-1000.

You may add to the CCU-11B to your TOA INTERCOM

SYSTEM EXES-1000, according to your specific needs,

to obtain various other functions.

Correct operation of these additional functions are not

available by only connection of the additional equip-

ments/devices.

Provision of such additional functions requires the

followings:

(1) Connection of the additional equipment, as required,

(2) Selection of functions which satisfy your needs and

setting up these functions in the respective equipment.

For (1) Connections of Equipment, etc., refer to Manual

of Installation Hand Book of EXES-1000 (EX-110)

Exchange.

This "Installation Hand Book of CCU-11B" deals prin-

cipally with (2) selection of functions and setting up of

respective equipment.

There are certain minimum installation requirements to

be met even though you may not need many additional

functions or additional equipment, it is still necessary to

read "4. Initial CCU-11B Set Up (Page 4.)". When you may

use only some of the additional functions or equipments,

it is not necessary to read instructions on unrequired

functions. Make sure, however, that careful study of the

necessary parts of this booklet should be done before

proceeding further.

EXES-1000 Installation Hand Book

EXES-1000 (EX-110)

Installation Handbook of Exchange.

or

EXES-1000 Installation Handbook

EXES-1000 (CCU-11B)

Installation Handbook

(133-21-012-7A)

2. FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS

Functions of CCU-11B which require either the addition of specific units or processing in existing units are as men-

tioned below.

FunctionAdditional Equip-

ment RequiredUnit Model No. Remarks

Talk-Back frompaging speaker

Talk-Back Unit TKU-11Optional amplifier (10W max.) may berequired depending on application.

— 2 —

Page 4: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

Please read following instructions carefully to ensure

proper operation of the CCU-11B.

1. Be careful about damage by static electricity as the

CCU-11B incorporates CMOS IC's. Do not touch com-

ponents and connectors.

2. Turn off the AC power switch when you take out or

insert the CCU-11B unit or any other unit.

3. Always insert the CCU-11B unit into the "CCU" slot.

Otherwise, there is a danger that the unit will be

damaged.

4. Make sure mini-jumper for battery back-up is always

placed in "ON" position each time it is used.

5. Incorrect setting of function select switches may lead

to incorrect performance.

3. PRECAUTIONS FOR INSTALLATION OF CCU-11B.

6. Even if you do not need programming functions, be

sure to carry out initial programming and registration

at station No. 11 when you install the new unit.

Otherwise, some other functions may not work

properly.

7. The Ni-Cd battery GB50-3FA1 is capable of saving im-

portant memory registration data even at times of

power failure and we suggest you replace i t at least

every 4 years.

8. When shipping the CCU-11B unit independently, place

the mini-jumper for battery back-up in "OFF"

position. Then cover CCU back with cardboard, wrap

connector section in aluminium foil and put it in a con-

ductive bag.

— 3 —

PROGRAM SWITCH for No. 11 Programming

Set this in "ON" position only at time of initial pro-

gramming of the exchange and registration of functions.

In this case, station No. 11 is "programming station" but

becomes a normal station when switch is placed in "OFF"

position.

Remote ControlReplay Output(RY1 and RY2)

SW-B (1 ~ 6)/SW1 These switchesSW-A (1 ~ 6)/SW2 select functions.

Mini-Jumper for Battery Back-up.

Ni-Cd BatteryGB50-3FA1 (3.6V 50mAH)

Page 5: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

4 INITIAL CCU-11B SET UP

Make sure that you have turned off the AC power switch.

Remove the CCU card from the card rack of exchange.

Set mini-jumper on the CCU card to "BATT. ON" position.

Set function selection DIP switches (SW-A & SW-B) on the CCU card forrequired functions.

Insert the CCU card into the card rack of exchange, and make necessaryconnection correctly.

Turn on the AC power switch of exchange.

Turn on PROGRAM switch on the CCU card.

NoFirst installation?

Yes

Initial set

Is all programming data required to be cleared?No

Yes

Dial operation from station #11

Confirmation tone

Touch ten times

Is Continuously Called Station necessary?Yes

To Continuous Calling ToneNo

Is Secretary Transfer necessary? Yes

NoTo Secretary Transfer

Is Master/Sub-station necessary?Yes

To Master/Sub-station

Is Executive Priority necessary?Yes

To Executive Priority

Dial operation from station #11.

Touch Key.

Turn off PROGRAM switch on the CCU card of exchange.

Station #11 returns to an ordinary station.

— 4 —

Page 6: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

5 DIP SWITCH FOR FUNCTION SELECTION ON CCU-11B

The DIP switches on the CCU-11B allow selection of the following functions;

Switches Functions DIP-SW "ON "Position DIP-SW "OFF "Position

Mini-Jumper for BatteryBattery "ON"

Position

Battery "OFF"

Position

OFF

OFF

Remote Control (Door)

Continues Calling Tone

OFF

OFF

Priority & Executive Priority

Press to Talk Control

Time Interval Adjustmentbefore All Call Paging Pre-announce Tone

Calling Tone Duration

Call Transfer

All Call Paging & Response

Make/Break Relay Output

Activate

Activate

Activate

1 ~ 2 sec.

Short (0.7 sec)

Activate

Activate

One shot Relay Output(4 sec.)

Not Activate

Not Activate

Not Activate

None

Long (1.3 sec)

Not Activate

Not Activate

Programming SwitchStation No. 11 is"Programming station'

Station No. 11 is anormal station

PROGsw

SW-B (SW1)

SW-A (SW2)

1: BATT. OFF2: BATT. ON

OFF

ON

A. All Call Paging and Response

B. Call Holding/Call Transfer

C. Calling Tone Duration

D. Time Interval Adjustment before All Call Paging

E. PTT Control

F. Priority and Executive Priority

G. Remote Control

H. Continuous Calling Tone

— 5 —

Page 7: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

6. STATION NO. 11 PROGRAMMING FOR EACH FUNCTION

Use station #11 for programming of "Continuous Calling Tone", "Secretary Transfer", "Master/Sub-Relationship" and/or

"Executive Priority" functions.

Remarks: 1. In the event of failure to touch keys for correct dialing, privacy tone will be sound.

Re-start from the beginning.

2. When All Call Paging is used, the registration to the station #10 can not be done.

The following shows how to register the functions:

1. Continuous Calling Tone

New registration ? No

Yes

Ascertain holding tone.

Continuously called station number

No All registration finished ?Yes

NoRelease ?Yes

Ascertain holding tone.

Station number to be released

No Release finished ?Yes

Return

— 6 —

Page 8: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

2. Secretary Transfer

New registration ?

Station Number Station Numberof executive of secretary

Ascertain holding tone

All registration finished ?

Release ?

Station Number Station Numberof executive of executive

Ascertain holding tone

Release finished ?

Return

3. Master/Sub-Relationship

New registration ?

Sub-station Number Master station Number

Ascertain holding tone

All registration finished ?

Release ?

Sub-station Number Sub-station Number

Ascertain holding tone

Release finished ?

Return

4. Executive Priority

New registration ?

Number of station where Executive Priority isregistered.

Ascertain holding tone

All registration finished ?

Release ?

Number of station where registration of ExecutivePriority is release.

Ascertain holding tone

Release finished ?

Return

— 7 —

Page 9: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

7. REMOTE CONTROL RELAYS (RY1 & RY2) ON CCU-11B

Remark: Relay Control Capacity: 30VDC, 2ARelays (RY1 & RY2) on CCU-11B are available for following functions.

RelayNo.

DIP Switch Position Functions and Operations

SW-A-3 "OFF"

A Door Remote Control (One-shot-Make Relay Output)

Every master station can be used as a remote control device for door open-

ing. Touch dial

the door opening.

gives approximately 4 seconds make-contact for

SW-A-3 "ON"

RY1

B Door Remote Control (Make-Break Relay Output)

Every master station can be used as a remote control device for door

opening. Touch dial gives continuous make-contact for door

opening. Then touch dial gives break-contact for door closing.

SW-B-2 "OFF"

RY2

C Power ON/OFF Remote Control

When the system is used in conjunction with PA amplifier for the external

All-Call paging, the power switch of the PA amplifier can be turned on/off

with the relay built in the system. Touch dial gives the make-contact

together with the All-Call function until the function is canceled by dialing

(Remark: Touch dial gives break-contact of the relay.)

SW-B-2 "ON"

D Press To Talk Control

Touch dialing the specific station #17.

One way conversation is activated while the Press-To-Talk bar is continu-

ously depressed, same as the Press-To-Talk (selected simplex) function, and

the relay is activated with continuous make-contact.

One way conversation is reversed when the Press-To-Talk bar is released, and

the relay is activated with break-contact.

— 8 —

Page 10: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

7-2. Connections

A. Connect 4-pin connector from TBM-11 (Terminal module) to P2 connection socket on the CCU-11B.

B. RM1 terminals on TBM-11 are for the door remote control relay contacts and RM2 terminals on TBM-11

are for the power ON/OFF remote control or press to talk remote control relay contacts.

(Please refer to the following diagram.)

YEL

DOOR

ORG

RED

BRN

AC

RM2 AC

In the case of power ON/OFF remote control.

— 9 —

RM1

Page 11: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

8. PROGRAMMING LIST FOR FUNCTIONS

Use these tables to keep a record of those functions assigned to each station.

Function Table for Stations

Functions

Name

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

Con

tinuo

usC

allin

g T

one

Exe

cutiv

e P

riority

Sec

reta

ryS

tatio

n N

o.

Mas

ter

Sta

tion

No.

— 10 —

Page 12: TOA EXES-1000 INTERCOM SYSTEM · B Door Remote Control (Make-Break Relay Output) Every master station can be used as a remote control device for door opening. Touch dialgives continuous

TOA ELECTRIC CO., LTD.KOBE, JAPAN

Printed in Japan