thales avionics electrical systems technical publication · pdf file1 2015 taes –...
TRANSCRIPT
1
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
THALES AVIONICS ELECTRICAL SYSTEMS
TECHNICAL PUBLICATION
ATR 42/72
- 2015 –
THALES
- CUSTOMER SUPPORT DEPARTMENT – 41 boulevard de la République – B. P. n° 53 – 78401 CHATOU CEDEX – France
Tel : 33 1 34.80.73.46 Fax : 33 1 34.80.75.95 E-Mail : [email protected]
2
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
APPLICABLE TECHNICAL PUBLICATION
1. General conditions
2. List of LRU’s
3. Details of evolutions
4. Statement of agreement
3
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
1. GENERAL CONDITIONS CMM : Component Maintenance Manual. TCMS : Technical Characteristics Maintenance Sheet. SB : Service Bulletin SIL : Service Information Letter E/R : Electronic/Rotable Technical Publications (CMM/SB/SIL) are available. To obtain the sale conditions, contact your Commercial Contact. Prior to the delivery of a CMM, the customer shall sign a Statement of Agreement.
2. LIST OF LRU’S
THALES vendor code
TAES P/N DESCRIPTION E/R Qty per plane
Applicability
F0296 156 Transformer E 2 All ATR
F0296 102-003-11 DC Generator Control Unit E 2 All ATR
F0296 103-003-2 (-11) Hall Effect Current Sensor (HECS) E 5 All ATR
F0296 105-003-2
105-003-1 DC Bus Power Control Unit E 1 All ATR
F0296 20032-2 Alternator R 2 All ATR
F0296 20732 Transformer (DPCT) E 3 All ATR
F0296 2432-11
2432-30 AC Generator Control Unit E 2 All ATR
F0296 559-012A 559-012B
559-012C 559-012D Static Inverter E 2 All ATR
F0296 680-0040-000 Emergency axe - 1 All ATR
F0296 8260-123
8260-121 DC Starter Generator R 2 All ATR
F0296 945-12
945-11 AC Bus Power Control Unit E 1 All ATR
F0296 F11NA3121 Transformer Rectifier Unit E 1 -500 and
ETOPS only
F0296 F46BC0101
F46BD0101 Control Box E 1 All ATR
F0296 F96GA0102
F96GA0101 Landing Gear Control Lever E 1 All ATR
F0296 B3893-000 DC-STAR GSE – Direct Current
System Tester Analyzer Recorder Ground Support Equipment
E / All ATR
4
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
3. DETAILS OF EVOLUTIONS
STARTER-GENERATOR P/N 8260-121
CMM reference : 24-32-61 Revision 10 : Date of update February, 09th 2012
Evolution Reason Application In
Production since
SB SIL
/ Brush and bearing
replacement
Mandatory during brush and bearing replacement
/ / SIL8260-120-005
Rev. 7 dated 03/09/2009
/ Best practice on Starter Generator
Operation, Maintenance,
storage, transportation,
handling.
/ / SIL8260-12X-24-007
Rev. 2 dated 27/03/2013
/ Recommended scheduled maintenance
/ / / SIL8260-12X-24-009
Rev. 3 dated 06/04/2006
/
Brush check procedure with S/G fitted on engine.
/ / / SIL8260-12X-24-010
Rev. 1 dated 09/09/2009
/ Brush replacement procedure
Mandatory during brush replacement
/ / SIL8260-12X-24-011
Rev. 2 dated 10/07/2009
/ Speed sensor tightening procedure.
During each speed sensor assembling operation
/ / SIL8260-12X-24-012
Rev. 1 dated 13/11/2009
/
Brush and bearing replacement without disassembly of the S/G.
Mandatory during brush and bearing replacement
/ / SIL8260-12X-24-013
dated 05/06/2009
/ Packaging for Starter Generator
Recommended for shipment
/ / SIL8260-12X-24-014
dated 09/07/2009
/ Armature information
Recommended / / SIL8260-12X-24-015
dated 09/11/2011
/ Checking of the torque shaft
Recommended / / SIL8260-12X-24-016
dated 10/12/2012
5
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/ Brushes replacement
Recommended / / SIL8260-12X-24-017
dated 10/09/2013
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / / SIL24-99-003
dated 05/09/2012
/ Second source of primer and paint
Recommended / / SIL24-99-004
Rev. 1 dated 19/06/2014
Amendment A, B & C
/ Do not exist for
this unit / / /
Amendment D Improvement of reliability
Recommended under repair
1989 SB8260-120-24-007
dated 03/08/1992 /
Amendment E Improvement of reliability
During repair if component has to be replaced & Recommended during overhaul.
1990 SB8260-120-24-006
dated 10/12/1990 /
Amendment F Improvement of reliability
During repair if component has to be replaced
1991 SB8260-120-24-005
Rev. 1 dated 12/04/1991
/
Amendment G Improvement of reliability
During repair if component has to be replaced
1994 / /
Amendment H Improvement of reliability
During repair if component has to be replaced
1998 SB8260-12X-24-008
Rev. 1 dated 21/12/1998
/
Amendment J Improvement of reliability
During repair if component has to be replaced
1998 SB8260-12X-24-009
Rev. 1 dated 21/12/1998
/
Amendment K Improvement of reliability
During overhaul 1998 SB8260-12X-24-010
dated 28/10/1997 /
8260-123 Improvement of scheduled maintenance
On customer request
2000 SB8260-12X-24-011
dated 21/12/1998 /
Amendment M Conformity Mandatory
during overhaul 2000
SB8260-12X-24-012 Rev. 1
dated 09/08/1999 /
6
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
Amendment N Improvement of reliability
During repair if component has to be replaced
2003 SB8260-12X-24-013
dated 17/12/2002 /
/ Overhaul procedure
Mandatory during overhaul
/ SB8260-12X-24-014
Rev. 1 dated 07/04/2004
/
Amendment P Component obsolescence
During repair if component has to be replaced
Only under repair since 2006
SB8260-12X-24-016 dated 17/12/2004
/
Amendment R Improvement of reliability
During repair if component has to be replaced
2012 SB8260-12X-24-017
dated 12/11/2012
STARTER-GENERATOR P/N 8260-123
CMM reference : 24-32-61 Revision 10 : Date of update February, 09th 2012
Evolution Reason Application In
Production since
SB SIL
/ Brush and bearing replacement
Mandatory during brush and bearing replacement
/ / SIL8260-120-005
Rev. 7 dated 03/09/2009
/ Best practice on Starter Generator
Operation, Maintenance,
storage, transportation,
handling.
/ / SIL8260-12X-24-007
Rev. 2 dated 27/03/2013
/ Recommended scheduled maintenance
/ / / SIL8260-12X-24-009
Rev. 3 dated 06/04/2006
/
Brush check procedure with S/G fitted on engine.
/ / / SIL8260-12X-24-010
Rev.1 dated 09/09/2009
7
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/ Brush replacement procedure
Mandatory during brush replacement
/ / SIL8260-12X-24-011
Rev. 2 dated 10/07/2009
/ Speed sensor tightening procedure.
During each speed sensor assembling operation
/ / SIL8260-12X-24-012
Rev. 1 dated 13/11/2009
/
Brush and bearing replacement without disassembly of the S/G.
Mandatory during brush and bearing replacement
/ / SIL8260-12X-24-013
dated 05/06/2009
/ Packaging for Starter Generator
Recommended for shipment
/ / SIL8260-12X-24-014
dated 09/07/2009
/ Armature information
Recommended / / SIL8260-12X-24-015
dated 09/11/2011
/ Checking of the torque shaft
Recommended / / SIL8260-12X-24-016
dated 10/12/2012
/ Brushes replacement
Recommended / / SIL8260-12X-24-017
dated 10/09/2013
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/ Second source of Anti-flash varnish
Recommended / / SIL24-99-003
dated 05/09/2012
/ Second source of primer and paint
Recommended / / SIL24-99-004
Rev. 1 dated 19/06/2014
Amendment A Improvement of reliability
During repair if component has to be replaced
2000 SB8260-12X-24-008
Rev. 1 dated 21/12/1998
/
Amendment B Improvement of reliability
During repair if component has to be replaced
2000 SB8260-12X-24-009
Rev. 1 dated 21/12/1998
/
Amendment D Conformity Mandatory
during overhaul 2000
SB8260-12X-24-012 Rev. 1
dated 09/08/1999 /
8
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
Amendment E Improvement of reliability
During repair if component has to be replaced
2003 SB8260-12X-24-013
dated 17/12/2002 /
/ Overhaul procedure
Mandatory during overhaul
/ SB8260-12X-24-014
Rev. 1 dated 07/04/2004
/
Amendment F Component obsolescence
During repair if component has to be replaced
2006 SB8260-12X-24-016
dated 17/12/2004 /
Amendment G Improvement of reliability
During repair if component has to be replaced
2012 SB8260-12X-24-017
dated 12/11/2012
AC GENERATOR P/N 20032-2
CMM reference : 24-22-61 Revision 4 : Date of update May, 30th 2008
Evolution Reason Application In
Production since
SB SIL
/ Verification of measurement
Under repair / / SIL20032-X-24-003
dated 06/1993
/ Verification of torque value
On aircraft Under repair
/ / SIL20032-2-24-007 dated 28/09/2004
/ Improvement of reliability
Under repair (overhaul or
bearing replacement)
/ / SIL20032-2-24-008 dated 24/03/2005
/ Best practice on AC Generator
Operation, Maintenance,
storage, transportation,
handling.
/ / SIL20032-2-24-010 dated 27/03/2013
9
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
Amendment A Component obsolescence
During repair if component has to be replaced
1988 SB20032-2-24-002 dated 15/02/1992
/
Amendment B Improvement of reliability
During repair of rotating diodes
bridges. 1988 / /
Amendment C Improvement of repair procedure
Under repair only if rewinding
of stator is necessary
Only under repair since 1997
/ /
Amendment D Improvement of reliability
On customer request
or if component
has to be replaced
(P058137)
1998 / /
Amendment E Improvement of reliability
Recommended / On customer
request or if component
has to be replaced
(P058137 or P058137A)
1999 SB20032-2-24-009
Rev. 1 dated 03/04/2008
/
Amendment F Improvement of reliability
During repair if component has to be replaced
1999 SB20032-2-24-005 dated 21/12/1998
/
Amendment G Improvement of reliability
During repair if component has to be replaced
1999 SB20032-2-24-006 dated 21/12/1998
/
Amendment H
Improvement of reliability & assembly procedure.
During repair if component has to be replaced
2004 SB20032-2-24-007 dated 04/12/2002
/
Amendment J
Improvement of reliability & assembly procedure. Qualification of a new source.
During repair if component has to be replaced (Diode-holder plate assy.)
2007 SB20032-2-24-008
Rev. 1 dated 03/04/2008
SIL20032-2-24-009 Rev. 1
dated 31/03/2008
Amendment K Improvement of reliability
During repair if component has to be replaced
2012 SB20032-2-24-010
Rev. 1 dated 12/11/2014
10
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
AC GCU P/N 2432-11
CMM reference : 24-22-14 Revision 4 : Date of update September, 30th 1999
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability
Mandatory during repair by
OEM only 1988
SB2432-11-24-002 dated 15/02/1992
/
Amendment B Improvement of reliability
Mandatory during repair by
OEM only 1988
SB2432-11-24-003 dated 15/02/1992
/
Amendment C Improvement of reliability
Mandatory during repair
1989 / /
Amendment D Component obsolescence
During repair if PCB or
component has to be replaced
Systematically during repair if
PCB Z500 must be replaced
Only under repair since 1998
SB2432-30-24-001 dated 25/04/2006
/
Amendment E Improvement of reliability
During repair if PCB or
component has to be replaced
Only under repair since 1998
SB2432-30-24-002 Dated 07/12/2009
SIL2432-11-24-001 dated 15/11/2006
2432-30
Modification for ATR72-210 version (new propeller).
On customer request
1994 SB2432-30-24-001
dated 10/1993 /
11
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
AC GCU P/N 2432-30
CMM reference : 24-22-14 Revision 4 : Date of update September, 30th 1999
Evolution Reason Application In
Production since
SB SIL
/ Mechanical check of the rear guide bushing.
Under repair / / SIL2432-30-24-001 dated 21/06/2007
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Component obsolescence
During repair if PCB or
component has to be replaced
Systematically during repair if
PCB Z500 must be replaced
1999 SB2432-30-24-001 dated 25/04/2006
/
Amendment B Improvement of reliability
During repair if PCB or
component has to be replaced
1999 SB2432-30-24-002 dated 07/12/2009
/
DC GCU P/N 102-003-11
CMM reference : 24-32-11 Revision 2 : Date of update July, 5th 2006
Evolution Reason Application In
Production since
SB SIL
/ Mechanical check of the rear guide bushing.
Under repair / / SIL102-003-11-24-
002 dated 21/06/2007
12
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability
Mandatory during repair.
1988 SB102-003-11-24-
001 dated 15/02/1992
/
Amendment B Improvement of reliability
Recommended during repair.
1988 SB102-003-11-24-
002 dated 15/02/1992
/
Amendment C Improvement of reliability
Mandatory during repair.
1988 SB102-003-11-24-
004 dated 15/02/1992
/
Amendment D Improvement of reliability
Mandatory during repair.
2001 SB102-003-11-24-
005 dated 22/12/1999
/
Amendment E Improvement of reliability
Mandatory during repair.
2004
SB102-003-11-24-006
Rev. 2 dated 08/11/2012
/
Amendment F Improvement of reliability
On customer request or if
PCB has to be repaired.
2005 SB102-003-11-24-
007 dated 27/01/2005
/
Amendment G Component obsolescence
During repair if selector switch or PCB has to be replaced
2006 SB102-003-11-24-
008 dated 25/04/2006
/
Amendment H Improvement of reliability
Recommended 2013 SB102-003-11-24-
009 dated 05/07/2013
/
AC BPCU GCU P/N 945-11
CMM reference : 24-41-13 Revision 3 : Date of update June, 15th 1999
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
13
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability
Mandatory during repair.
1989 SB945-11-24-002
ated 02/1992 /
945-12 Improvement of reliability
On customer request.
1997 SB945-11-24-003 dated 30/06/1996
/
AC BPCU GCU P/N 945-12
CMM reference : 24-41-13 Revision 3 : Date of update June, 15th 1999
Evolution Reason Application In
Production since
SB SIL
/ Mechanical check of the rear guide bushing.
/ / / SIL945-12-24-001 dated 21/06/2007
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
14
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
DC BPCU P/N 105-003-1
CMM reference : 24-76-13 Revision 3 : Date of update August, 8th 2006
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability
Mandatory during repair.
1994 SB105-003-24-003
dated 02/1992 /
Amendment B Improvement of reliability
Mandatory during repair.
1994 SB105-003-24-004
dated 02/1992 /
Amendment C Improvement of manufacturing process
During repair if component has to be replaced
1994 SB105-003-24-005
dated 02/1992 /
Amendment D Improvement of reliability
Mandatory during repair.
1994 SB105-003-24-006
dated 02/1992 /
Amendment E Improvement of reliability
Mandatory during repair.
1994 SB105-003-24-007
dated 02/1992 /
Amendment F Improvement of reliability
Mandatory during repair.
1994 SB105-003-24-001
dated 09/1990 /
Amendment G Improvement of reliability
Mandatory during repair.
Only under repair since 1993
/ /
Amendment H Improvement of reliability
During repair if PCB or
component has to be replaced
Only under repair since 1998
SB105-003-24-008 dated 21/12/1998
/
Amendment J Improvement of reliability
During repair if PCB has to be
replaced.
Only under repair since 1998
/ /
Amendment K Improvement of reliability
During repair if PCB or
component has to be replaced
Only under repair since 1999
SB105-003-24-009 dated 21/12/1998
/
15
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
Amendment L Improvement of reliability
During repair if PCB or
component has to be replaced
Only under repair since 1999
/ /
Amendment M Component obsolescence
During repair if PCB or
component has to be replaced
Only under repair since 2001
/ /
Amendment N Improvement of reliability
Mandatory during repair.
Only under repair since 2003
SB105-003-24-011 dated 12/01/2004
/
Amendment P Component obsolescence
During repair if PCB or
component has to be replaced
Only under repair since 2004
SB105-003-24-012 dated 25/04/2006
/
105-003-2 Improvement of reliability
On customer request.
1990 SB105-003-24-002
dated 02/1992 /
DC BPCU P/N 105-003-2
CMM reference : 24-76-13 Revision 3 : Date of update August, 8th 2006
Evolution Reason Application In
Production since
SB SIL
/ Mechanical check of the rear guide
bushing. / / /
SIL105-003-2-24-001 dated 26/06/2007
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
16
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
Amendment G Improvement of reliability
On customer request.
1994 / /
Amendment H Improvement of reliability
Mandatory during repair.
1994 / /
Amendment J Improvement of reliability
During repair if PCB or
component has to be replaced
1999 SB105-003-24-008 dated 21/12/1998
/
Amendment K Improvement of reliability
During repair if PCB has to be
replaced. 1999 / /
Amendment L Improvement of reliability
During repair if PCB or
component has to be replaced
2000 SB105-003-24-009 dated 21/12/1998
/
Amendment M Improvement of reliability
During repair if PCB or
component has to be replaced
2000 / /
Amendment N Component obsolescence
During repair if PCB or
component has to be replaced
2002 / /
Amendment P Component obsolescence
During repair if PCB or
component has to be replaced
2003 SB105-003-24-010 dated 12/01/2004
/
Amendment R Improvement of reliability
Mandatory during repair.
2004 SB105-003-24-011 dated 12/01/2004
/
Amendment S Component obsolescence
During repair if PCB or
component has to be replaced
2005 SB105-003-24-012 dated 25/04/2006
/
17
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
STATIC INVERTER P/N 559-012A
CMM reference : 24-21-11 Revision 3 : Date of update January, 15th 2015
Evolution Reason Application In
Production since
SB SIL
/ Checking of over-voltage threshold protection
Under repair / / SIL 559-012B-24-001
dated 15/06/2006
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability
Mandatory during repair
1995 / /
Amendment B
Improvement of the control of "Static Inverter fault" signal
Mandatory during repair
1995 / /
Amendment C
Improvement of reliability of auxiliary power card
Mandatory during repair
Only under repair since 1997
SB559-012A-80-001 dated 15/12/1997
/
Amendment D Component obsolescence
During repair if PCB or
component has to be replaced
Only under repair since 2004
/ /
559-012C
Improvement of reliability in order to avoid double loss of static inverter
Mandatory during repair
Only under repair since 2009
SB559-012AB-24-002
Rev. 1 dated 25/01/2011
/
STATIC INVERTER P/N 559-012B
CMM reference : 24-21-11 Revision 3 : Date of update January, 15th 2015
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
18
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A
Improvement of reliability of auxiliary power card
Mandatory during repair
Only under repair since 1997
SB559-012A-80-001 dated 01/12/1997
Amendment B Component obsolescence
During repair if PCB or
component has to be replaced
2005 / /
559-012D
Improvement of reliability in order to avoid double loss of static inverter
Mandatory during repair
2008
SB559-012AB-24-002
Rev. 1 dated 25/01/2011
/
STATIC INVERTER P/N 559-012C
CMM reference : 24-21-11 Revision 3 : Date of update January, 15th 2015
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
STATIC INVERTER P/N 559-012D
CMM reference : 24-21-11 Revision 3 : Date of update January, 15th 2015
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
19
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
Evolution Reason Application In
Production since
SB SIL
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
TRU P/N F11NA3121
CMM reference : 24-32-13 Revision / : Date of update October, 15th 1996
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
LIGHTING TRANSFORMER P/N 156
Technical Characteristics & Maintenance Sheet reference : 30-31-13 Revision 3 : Date of update April, 2010
Evolution Reason Application In
Production since
SB SIL
/ / / / / /
20
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
CONTROL BOX P/N F46BC0101
CMM reference : 26-15-24 Revision 1 : Date of update December, 01st 1993
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability and functionning.
Mandatory under repair.
1987 / /
Amendment B Improvement of manufacturing & repair processes.
During repair if necessary.
2009 SBF46BC0101-24-
001 dated 29/08/2012
/
/ Inspection of the fan control box
Unit in operation
2012 SBF46BC0101-24-
002 dated 31/08/2012
Amendment C Improvement of reliability
During repair if necessary.
2012 SBF46BC0101-24-
004 dated 25/09/2014
/
Amendment D Improvement of reliability
During repair if necessary.
2012 SBF46BC0101-24-
003 dated 25/02/2014
/
CONTROL BOX P/N F46BD0101
CMM reference : 26-15-25 Revision / : Date of update June, 15th 2001
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/
Electrostatic Discharge Sensitive Components
Recommended / / SIL24-99-002
dated 09/12/2010
Amendment A Improvement of reliability.
Only under production.
1996 / /
21
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
LANDING GEAR CONTROL LEVEL P/N F96GA0101
CMM reference : 32-31-11 Revision 2 : Date of update January, 26th 2009
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
LANDING GEAR CONTROL LEVEL P/N F96GA0102
CMM reference : 32-31-11 Revision 2 : Date of update January, 26th 2009
Evolution Reason Application In
Production since
SB SIL
/ Order consumables products
Recommended / / SIL24-99-001
dated 03/01/2011
/ Screw replacement
Recommended / / SILF96GA0102-32-
001 Rev. 1 dated 21/10/2014
Amendment A Improvement of
functionning Mandatory
during repair. 1987 / /
Amendment B Improvement of
reliability On customer
request. 1989 / /
Amendment C Improvement of
reliability On customer
request. 1998
SBF96GA0102-24-001
dated 21/12/1998 /
Amendment D Improvement of
functionning
During repair if component has to be replaced.
2001 / /
22
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
TRANSFORMER (DPCT) P/N 20732
(DPCT : Differential Protection Current Transformer)
Technical Characteristics & Maintenance Sheet reference : 24-22-11 Revision 2 : Date of update June, 1993
Evolution Reason Application In
Production since
SB SIL
/ / / / / /
HALL EFFECT CAPTOR SENSOR P/N 103-003-2
Technical Characteristics & Maintenance Sheet reference : 24-32-12 Revision 4 : Date of update April, 2006
Evolution Reason Application In
Production since
SB SIL
Amendment A Improvement of reliability
Only under production
1998 / /
Amendment B Improvement of reliability
Only under production
2003 / /
Amendment C Improvement of reliability
Only under production
2005 / /
Amendment D Obsolescence of the potting resin
Only under production
2010 / /
23
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
EMERGENCY AXE P/N 680-0040-000
Technical Characteristics & Maintenance Sheet reference : 25-65-01 Revision 1 : Date of update 1992
Evolution Reason Application In
Production since
SB SIL
/ Packaging for Emergency axe
Recommended for shipment
/ / SIL680-0040-000-25-
001 dated 26/10/2009
DC-STAR GSE P/N B3893-000
USER MANUAL : Y28-0617
Revision a : Date of update October, 17rd 2008
Evolution Reason Application In
Production since
SB SIL
/ / / / / /
24
2015 TAES – TECHNICAL PUBLICATION
Issued: January 2015
ATR
4. STATEMENT OF AGREEMENT
Statement of Agreement to Terms and Conditions of Sale of Thales Technical Publications Thales Component Maintenance Manual 24-XX-XX is intended solely for use by Company Name. Copying, reproducing or redistribution of this or any Thales Component Maintenance Manual (CMM) or Service Bulletin (SB), to any other party or location is strictly prohibited without Thales prior written consent. Thales retains all intellectual property rights, title and interest in the CMMs and/or SBs provided, including all rights under applicable patents, copyrights, trademarks and trade secrets, and all renewals and extensions thereto. Company Name shall not alter or remove any patent, copyright, trademark, or proprietary rights notice. Agreed to and Accepted by: ____________________________ __________________________ (Print Name) (Title) ____________________________ __________________________ (Signature) (Date)