sustainability: process field networks
TRANSCRIPT
S t i bilit Th h PS t i bilit Th h PSustainability Through Process Field Networks
Sustainability Through Process Field Networks
Wil ChinResearch Director
ARC Advisory [email protected]@ARCweb.com
Diverse Communication Technologies Diverse Communication Technologies
Supervisory
Control PROFInetPROFInet
ORK
LEV
EL
HSE
I/ODP, PAN
ETW
O
Device
TYPE OF CONTROL
H1
2© ARC Advisory Group
Machinery ProcessTYPE OF CONTROL
2009 Process Field Network Survival Guide2009 Process Field Network Survival Guide
New and Brownfield: E t d M d i ti & R iExtend –Modernization & Repair Measured Field Investments Invest in Value InitiatesInvest in Value InitiatesMore Productivity with LessUse Existing InfrastructureUse Existing Infrastructure Networks Provide Access to Information
Use Economical Field Networks to Access Intelligence - Reduce Operational and
3© ARC Advisory Group
Maintenance Cost
Plant Asset Management Growth ($Millions)Plant Asset Management Growth ($Millions)
Total Shipments of PAMCAGR=10 8%
24062500
3000
CAGR=10.8%
1443.81571
17231910
2138
1500
2000
500
1000
1500
0
500
2006 2007 2008 2009 2010 2011
4© ARC Advisory Group
Achievable PAM Benefits Achievable PAM Benefits
O&G, Chemical, Petrochemical, Power IndustriesIndustries• Removed 183 of overtime hours • Reduced monthly work orders by 8%
Improved planned work mix to 40%• Improved planned work mix to 40%• Saved $800k in 6 months• Saved $200 device in commissioning and installation
R d d h k t ti b 30%• Reduced checkout time by 30%• Increase production by 4-10%• Reduced unplanned shutdown by 9%
d d l b 20%• Reduced total maintenance cost by 20%• Reduced valve maintenance by 50%
5© ARC Advisory Group
Worldwide Installed Base of Field DevicesField Devices - Press, Temp, Flow, Level, Valve Positioners, AnalyticalWorldwide Installed Base of Field DevicesField Devices - Press, Temp, Flow, Level, Valve Positioners, Analytical
58 Million Installed Devices in 2007
Smart Non - Smart
6© ARC Advisory Group
Process Field CommunicationsProcess Field Communications
N l 24 illi HART d iNearly 24 million HART devices are installed in process plants around the globegHART communication protocol is a low cost solution for 2009 economic h llchallenges
Foundation Fieldbus & Profibus Continues to be the protocol of choiceContinues to be the protocol of choice for “Greenfield” capital projects
7© ARC Advisory Group
Why HART?Why HART?
Low Risk SolutionL C t S l tiLow Cost SolutionAvailability of ProductsAlready Halfway There Use Existing FieldAlready Halfway There- Use Existing Field DevicesProven Value Enables PAM of Field DevicesWireless HART Standard
8© ARC Advisory Group
WirelessHARTWirelessHART
Built on the HART StandardsBackward compatibleBackward compatibleDelivers benefits to users independent of the age of control systemsEnables transition to a predictive maintenance strategy to:• Lower operating and maintenance costLower operating and maintenance cost• Increase plant availability• Help in regulatory compliance
HART certified devices by May 2009HART certified devices by May, 2009
9© ARC Advisory Group
WirelessHART ApplicationsWirelessHART Applications
Capture device and process information via PAM solution Communicate installed base of existing HART device diagnostics using a wireless adapterdevice diagnostics using a wireless adapterDeploy measurement previously not cost-effective Simplify installation and commissioning • Uses the same HART tools
l d• Minimal training required
10© ARC Advisory Group
Wireless Field Device PenetrationWireless Field Device Penetration
15%
5%
10%
11© ARC Advisory Group
Success “HART Plant of The Year”Success “HART Plant of The Year”
PDVSA near Barcelona, Venezuela248 000 b l d fi248,000 barrel per day refinery7.5°API FeedstockProduces Synthetic CrudeProduces Synthetic Crude5,000 Field Devices tied to DCSMultiple Field Device SuppliersMultiple Field Device SuppliersEmerson AMS PAM SystemHoneywell DCSyOther Suppliers: Dresser Masoneilan, Endress +Hauser, General Monitors, Saab, Control logic
12© ARC Advisory Group
Award Presentation PhotosAward Presentation Photos
13© ARC Advisory Group
ResultsResults
Increased Wrench Time by 10%Increased Wrench Time by 10%• Optimized Maintenance • Predictive Maintenance• Predictive Maintenance• Traceable Calibration Records
Allows the Workforce to do More With Less
14© ARC Advisory Group
ResultsResults
60% reduction of Lost Profit Opportunities (LPO) caused by field device faultsReduced “Bad Actors” by 95%Reduced Bad Actors by 95%• Reducing Random Failures
Reduced LPO by $70 m in 2-yearsReduced LPO by $70 m in 2 years
Strong Case for Field Networks in Good and Bad Economies
15© ARC Advisory Group
Good and Bad Economies
FDT Enables Information Access FDT Enables Information Access
Configuration Optimization PAM ReliabilityConfiguration Optimization PAM ReliabilitySupported Protocols
Process IndustryFDT Process IndustryFDT
HART
Foundation Fieldbus
CIP (DeviceNet/IP, CompoNet)
Interbus Process IndustryFDTDiscrete Industry
Hybrid Industry
Process IndustryFDTDiscrete Industry
Hybrid Industry
Interbus
IO-Link
Modbus SL/TCP
Profibus DP/PA
Profinet I/O
ProfibusDevices
SensorBuses
Devices
Foundation FieldbusDevices
HARTDevices
ProfibusDevices
SensorBuses
Devices
Foundation FieldbusDevices
HARTDevices
ProfibusDevices
SensorBuses
Devices
Foundation FieldbusDevices
HARTDevices
Profinet I/O
Pending Protocols
CANopen
FDT Enables Interoperability Regardless of Industry, Protocol, and Application
SERCOS III
AS-I
EtherCAT
16© ARC Advisory Group
Visit FDT in the Innovation Showcase
Thank You.Thank You.For more information, contact the author at
[email protected] or visit our web pages atwww arcweb com
17© ARC Advisory Group
www.arcweb.com