13
Page 1 of 13 Step 1 1.1 1.2 Step 1.1 Install ATA Shield at Bottom of Penetration and extend to the Eave. Step 1.2 Fold sides of the ATA Shield up onto the Penetration. This square penetration method can be used for all vertical seam roof systems with minor modifications.

Upload: others

Post on 24-Feb-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 1 of 13

S

t

e

p

1

1.1

1.2

Step 1.1 Install ATA Shield at

Bottom of Penetration and extend

to the Eave.

Step 1.2 Fold sides of the ATA

Shield up onto the Penetration.

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 2: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 2 of 13

S

t

e

p

2

Step 2.1 Install ATA Shield at

sides of Penetration, overlaping

on top of the bottom ATA Shield.

Step 2.2 Fold sides of the ATA

Shield up onto the Penetration.

2

4

"

M

i

n

.

2.1

2.2

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 3: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 3 of 13

S

t

e

p

3

2

4

"

(

m

i

n

.

)

Step 3.1 Install ATA Shield at

the top of Penetration,

overlaping on top of the side ATA

Shield.

Step 3.2 Fold sides of the ATA

Shield up onto the Penetration.

3.1

3.2

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 4: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 4 of 13

S

t

e

p

4

Step 4.1 Install ATA Guard on

Roof Deck.

4.1

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 5: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 5 of 13

S

t

e

p

5

Step 5.1 Install Roof Panels up

to and around the Penetration.

Step 5.2 Field Trim and Bend

Roof Panel around Penetration to

provide a Water Leg.

5.1

5.2

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 6: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 6 of 13

S

t

e

p

6

Step 6.1 Field Fabricate

Flashing Pan as shown.

Step 6.2 When installing

Flashing Pan, apply two beads

of Sealant between Pan and

Roof Panels.

6.2

6.1

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 7: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 7 of 13

S

t

e

p

7

Step 7.1 Field Notch and Bend

Z Closures to fit around

Penetration.

Step 7.2 Install Z Closures on

Roof Panels and Flashing Pan

with Butyl Sealant Tape and

Appropriate Fasteners

7.1

7.2

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 8: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 8 of 13

S

t

e

p

8

Step 8.1 Field Fabricate Lower

Sidewall Trim.

Step 8.2 Install Lower Sidewall

Trim on Z Closures and secure

with Appropriate Fasteners to

Penetration.

Step 8.3 Field Trim and Bend

Lower Sidewall Trim around sides

of Penetration and secure with

Appropriate Fasteners.

8.1

8.2

8.3

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 9: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 9 of 13

S

t

e

p

9

Step 9.1 Field Fabricate Side

Sidewall Trim.

Step 9.2 Install Side Sidewall

Trim on Z Closures and secure

with Appropriate Fasteners to

Penetration.

Step 9.3 Field Trim and Bend

Side Sidewall Trim around Top of

Penetration and secure with

Appropriate Fasteners.

Step 9.4 Field Bend Side

Sidewall Trim at bottom of

Penetration to have color on

both sides of trim.

9.1

9.2

9.3

9.4

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 10: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 10 of 13

S

t

e

p

1

0

Step 10.1 Field Fabricate

Upper Flashing Trim.

Step 10.2 Install Upper

Flashing Trim on Z Closures and

secure with Appropriate

Fasteners to Penetration.

Step 10.3 Field Bend Upper

Flashing Trim at Sides of

Penetration to have color on

both sides of trim.

10.110.2

10.3

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 11: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 11 of 13

S

t

e

p

1

1

Step 11.1 Install Joggle Cleat

set in Butyl Sealant Tape and

secured with Appropriate

Fasteners.

Step 11.2 Joggle Cleat must

have 4" minimum lap with

Flashing Pan.

Step 11.3 Apply a continuous

bead of Sealant to all

intersection of Flashing Trims to

completely seal the unit.

11.1

11.2

11.3

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 12: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 12 of 13

S

t

e

p

1

2

Step 12.1 Install Painted Pop

Rivets securing Lower Sidewall,

Side Sidewall and Upper

Flashing Trims to the Z Closures.

8" O.C. Max.

Step 12.2 Field Trim and Bend

Roof Panels onto Joggle Cleat.

Step 12.3 Install Panel End

Caps and Pop Rivet into Place.

12.1

12.1

12.2

12.3

This square penetration method can be used for all vertical seam roof systems with minor modifications.

Page 13: Step 1.1 Install ATA Shield at Page 1 of 13...Step 2.1 Install ATA Shield at sides of Penetration, overlaping on top of the bottom ATA Shield. Step 2.2 Fold sides of the ATA Shield

Page 13 of 13

S

t

e

p

1

3

Step 13.1 Continue installing

Roof Panels as Usual.

13.1

This square penetration method can be used for all vertical seam roof systems with minor modifications.