starmark - star building systems · [email protected] star building systems an nci...

2
Insulated Panel Systems Standing Seam Roof System Roof and Wall Systems Attributes Advantages 1. Semi-concealed fastener panel 1. Attractive architectural application 2. Unique side lap feature 2. Conceals panel side laps for aesthetically pleasing appearance 3. Continuous eave to sill to 32' length 3. Eliminates end laps and improves appearance 4. Fire Rating 4. The panel is classified by UL ® for 1 & 2 hour fire resistance 5. Signature ® 200 Colors 5. 25-year finish warranty 6. Signature ® 300 Colors option 6. 25-year premium paint finish warranty with ultimate resistance to chalking and color changes Gauge 26 gauge (standard) 24 gauge Length Maximum length of 32'-0" Dimensions 36" wide by 1" high Usage Wall panel, liner panel and façade panel Finish Galvalume Plus ® Signature ® 200 Colors Signature ® 300 Colors Fasteners Semi-concealed, self drilling fasteners, long life coated to match wall color Description StarMark is a functional 36" wide wall panel that provides aesthetics and cost efficiency. An architecturally sculptured shadow panel is achieved with 1" deep ribs to help conceal fasteners. Major corrugations on 12" center not only provide panel strength and integrity, they enhance the panel’s aesthetically pleasing sculptured look as well. StarMark Wall System

Upload: others

Post on 01-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: StarMark - Star Building Systems · star.marketing@starbuildings.net  Star Building Systems an NCI Company. Created Date: 8/1/2011 11:36:31 AM

Insu

late

d Pa

nel

Syst

ems

Stan

ding

Sea

m

Roof

Sys

tem

Roof

and

Wal

l Sy

stem

s

Attributes Advantages

1. Semi-concealed fastener panel 1. Attractive architectural application2. Unique side lap feature 2. Conceals panel side laps for aesthetically

pleasing appearance3. Continuous eave to sill to 32' length 3. Eliminates end laps and improves appearance4. Fire Rating 4. The panel is classified by UL® for 1 & 2 hour

fire resistance 5. Signature® 200 Colors 5. 25-year finish warranty6. Signature® 300 Colors option 6. 25-year premium paint finish warranty with

ultimate resistance to chalking and color changes

Gauge 26 gauge (standard) 24 gauge

LengthMaximum length of 32'-0"

Dimensions36" wide by 1" high

Usage Wall panel, liner panel and façade panel

Finish Galvalume Plus® Signature® 200 Colors Signature® 300 Colors

Fasteners Semi-concealed, self drilling fasteners, long life coated to match wall color

DescriptionStarMark is a functional 36" wide wall panel that provides aesthetics and cost efficiency. An architecturally sculptured shadow panel is achieved with 1" deep ribs to help conceal fasteners. Major corrugations on 12" center not only provide panel strength and integrity, they enhance the panel’s aesthetically pleasing sculptured look as well.

StarMark Wall System

Page 2: StarMark - Star Building Systems · star.marketing@starbuildings.net  Star Building Systems an NCI Company. Created Date: 8/1/2011 11:36:31 AM

Roof and Wall

Systems

Standing Seam

Roof Systems

Insulated Panel System

s

The engineering data contained herein is for the expressed use of customers and design professionals.

Along with this data, it is recommended that the design professional have a copy of the most current

version of the North American Specification for the Design of Cold-Formed Steel Structural Members

published by the American Iron and Steel Institute to facilitate design. This specification contains the

design criteria for cold-formed steel components. Along with the specification, the designer should

reference the most current building code applicable to the project jobsite in order to determine

environmental loads. If fur ther information or guidance regarding cold-formed design practices is

desired, please contact the manufacturer.

EFFECTIVE JULY 22, 2010SUBJECT TO CHANGE WITHOUT NOTICE

Galvalume Plus® is a registered trademark of BIEC International, Inc.

Signature® is a registered trademark of the NCI Group.

Properties Notes:1. Section proper ties have been calculated

in accordance with the 1986 AISI Cold-Formed Specification with 1989 addendum.

2. Steel thickness was used in determining section properties. Coated thickness includes galvanized or zinc-aluminum coating.

Allowable Uniform Loads Notes:1. Top values are based on stress.

¹/3 for wind load is included.

2. Bottom values are based on deflection of L/120 for 10 year wind (L/90 for 50 year wind).

3. Standard fastener pullover allowable is 222 lbs. including 1.3 increase for wind (#12 fastener without washer).

Allowable Load (PSF) For Nominal Purlin Spacing

StarMark - Section Properties

StarMarkWall System

NEGATIVE BENDING POSITIVE BENDING

PANEL GAUGE

Ap (IN2/FT.)

G' (#/IN.)

Ix (IN.4/FT.)

Sx (IN.3/FT.)

Ix (IN.4/FT.)

Sx (IN.3/FT.)

Fb (KSI)

26 0.752 0.03748 0.05073 0.03552 0.05763 30

24 0.927 0.04551 0.06160 0.04313 0.06998 30

26 Gauge

SPANTYPE

LOADCONDITION

PURLIN SPACE

5' 6' 7'

SIMPLE

PRESSURE 54.0052.42

37.5030.34

27.5519.10

SUCTION 61.3549.68

42.6028.75

31.3018.10

2-SPAN

PRESSURE 61.35123.09

42.6071.23

31.3044.86

SUCTION 54.00123.09

37.5071.23

27.5544.86

3-SPAN

PRESSURE 76.6996.33

53.2555.75

39.1335.10

SUCTION 67.5096.33

46.8855.75

34.4435.10

24 Gauge

SPANTYPE

LOADCONDITION

PURLIN SPACE

5' 6' 7'

SIMPLE

PRESSURE 65.5863.65

45.5436.83

33.4623.20

SUCTION 74.5060.32

51.7334.91

38.0121.98

2-SPAN

PRESSURE 74.50149.46

51.7386.49

38.0154.47

SUCTION 65.58149.46

45.5486.49

33.4654.47

3-SPAN

PRESSURE 93.12116.97

64.6767.69

47.5142.63

SUCTION 81.97116.97

56.9267.69

41.8242.63

36"

1"

2¼"

8600 South I-35, Oklahoma City, OK 73149

[email protected]

www.StarBuildings.com

Star Building Systemsan NCI Company