smartlinc - locksmith reference · • selectable for each lock - time lock 1, time lock 2 or no...

8
SMARTLINC Multiple Lock System logic module & set-up instructions AVAILABLE FEATURES MASTER CODE (Factory set to 1-2-3-4-5-6-7-8) • Change Code • Enroll/Delete Locks • Install/Delete Manager • Set Lock Options • Reprogram Software • Access to Master Menu • Download Audit • Set Time Lock Periods MANAGER CODE (Factory set to 1-1-1-1-1-1) • Manages Users • Change Time Delay Values • Download Audit • Control Temporary Time Lock • Extend Open Period, if enabled USER CODE • Up to nine users per lock, including Manager • Open Lock • Change Code • Set Immediate Lock MULTIPLE LOCKS • Up to Five APB (Auxiliary Power Box) • Must be ordered with every system no matter how many locks are enrolled • Provides constant power to audit information in the event of primary (battery or A/C) power loss eKEY II MODE • Available on each lock, if enabled • Available for Manager and Users only TIME DELAY • Programmable on each lock • Delay Period: 1 - 99 minutes • Open Period: 1 - 19 minutes • Delay Counting mode selectable (up, down or invisible) • Two Time Delays Can Run At Once TIME DELAY OVERRIDE • Ability to override time delay • Assigned to User #9, if enabled SILENT SIGNAL ALARM (Optional Alarm Box Required) • Programmable on each lock • Unavailable on a single lock system using AC Power REMOTE DISABLE (Optional Alarm Box Required) • Programmable on each lock • Unavailable on a single lock system using AC Power AUDIT • Each lock will record the last 500 operations with time, date, user and define the activity DUAL CODE • Programmable on each lock • If set up, automatically installs User #2 (Default User Code 2-2-2-2-2-2) • Two Codes required to open and access Manager Menu WRONG TRY PENALTY • Four (4) consecutive invalid codes initiates five-minute delay period LOW BATTERY WARNING • Repeated audio and visual signal (LCD readout and repeated beeping) during opening indicates battery low AUDIO AND VISUAL SIGNAL • Double signal (LCD readout and unit beeps) indicates entry is valid or accepted • Triple signal indicates invalid or not accepted TIME LOCK • Two Time Lock periods are available for set-up • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20 close periods programmable with day and month - i.e., January 1, July 4) • Immediate Time Lock (until next available open period) • Temporary Time Lock (to required date and time, maximum of four (4) weeks) • Time Lock Open Period Extension (Maximum two (2) hours), if enabled • Daylight Saving Time SYSTEM RECOMMENDATION • It is recommended to run the SMARTLINC software on a PC or laptop running Windows® 2000 or higher. © copyright 2005 (P/N)12-249 v2 • 9/08 Kaba Mas LLC page 1 of 8 Optional eKey II P/N 40169

Upload: others

Post on 17-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

SMARTLINCMultiple Lock System

logic module & set-up instructions

AVAILABLE FEATURESMASTER CODE (Factory set to 1-2-3-4-5-6-7-8)• ChangeCode• Enroll/DeleteLocks• Install/DeleteManager• SetLockOptions• ReprogramSoftware• AccesstoMasterMenu• DownloadAudit• SetTimeLockPeriods

MANAGER CODE(Factory set to 1-1-1-1-1-1)• ManagesUsers• ChangeTimeDelayValues• DownloadAudit• ControlTemporaryTimeLock• ExtendOpenPeriod,ifenabled

USER CODE• Uptonineusersperlock,includingManager• OpenLock• ChangeCode• SetImmediateLock

MULTIPLE LOCKS• UptoFive

APB (Auxiliary Power Box)• Mustbeorderedwitheverysystemnomatterhowmanylocks areenrolled• Providesconstantpowertoauditinformationintheeventofprimary (batteryorA/C)powerloss

eKEYII MODE• Availableoneachlock,ifenabled• AvailableforManagerandUsersonly

TIME DELAY• Programmableoneachlock• DelayPeriod:1-99minutes• OpenPeriod:1-19minutes• DelayCountingmodeselectable(up,downorinvisible)• TwoTimeDelaysCanRunAtOnce

TIME DELAY OVERRIDE• Abilitytooverridetimedelay• AssignedtoUser#9,ifenabled

SILENT SIGNAL ALARM(Optional Alarm Box Required)• Programmableoneachlock• UnavailableonasinglelocksystemusingACPower

REMOTE DISABLE(Optional Alarm Box Required)• Programmableoneachlock• UnavailableonasinglelocksystemusingACPower

AUDIT• Eachlockwillrecordthelast500operationswithtime,date,user anddefinetheactivity

DUAL CODE• Programmableoneachlock• Ifsetup,automaticallyinstallsUser#2(DefaultUser Code2-2-2-2-2-2)• TwoCodesrequiredtoopenandaccessManagerMenu

WRONG TRY PENALTY• Four(4)consecutiveinvalidcodesinitiatesfive-minutedelayperiod

LOW BATTERY WARNING• Repeatedaudioandvisualsignal(LCDreadoutandrepeated beeping)duringopeningindicatesbatterylow

AUDIO AND VISUAL SIGNAL• Doublesignal(LCDreadoutandunitbeeps)indicatesentryisvalid oraccepted• Triplesignalindicatesinvalidornotaccepted

TIME LOCK• TwoTimeLockperiodsareavailableforset-up• Selectableforeachlock-TimeLock1,TimeLock2orNo TimeLock• StandardWeek(4openperiodsperday)• SpecialEvents(upto20closeperiodsprogrammablewithdayand month-i.e.,January1,July4)• ImmediateTimeLock(untilnextavailableopenperiod)• TemporaryTimeLock(torequireddateandtime,maximumoffour (4)weeks)• TimeLockOpenPeriodExtension(Maximumtwo(2)hours), ifenabled• DaylightSavingTime

SYSTEM RECOMMENDATION• ItisrecommendedtoruntheSMARTLINCsoftwareonaPCor laptoprunningWindows®2000orhigher.

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage1of8

OptionaleKeyII

P/N40169

Page 2: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage2of8

Opening SMARTLINC Set-up SoftwareOnceallofthesoftwarehasbeeninstalledonthecomputer,itistimetobeginsettinguptheLogicModuleandlock(s).Opentheset-upsoftware.UsingeitherWindowsExplorerortheSTARTbutton,findtheLAGARDfolderontheharddrive.WithintheLAGARDfolderthereare3folderslabeledDSTUpdate,SMARTLINCandTotalAudit.OpentheSMARTLINCfolderanddoubleclickonthefilenamedSMARTLINCSETUP(seeScreen1).

SMARTLINC Set-up SoftwareTheopeningwindowoftheset-upsoftwareallowsthechoiceofLockSet-up,ControlUnit(LogicModule)Set-up,TimeLockSet-upandExitingtheSet-upsoftware(seeScreen2).

COM Port Set-upTheCOMportmustbeselectedbeforebeginningset-up.SelecttheappropriateCOMportfromthePortMenu.ThedefaultisCOM1(seeScreens3&4).

LOCK SET-UPTosetupthelocks,clickontheLockSet-upbuttonontheopeningscreen(seeScreen2).Awindowwiththedefaultconfigurationwillappear(seeScreen5).Inthiswindow,selectthefeaturestobeenabledonthelocks. • SelectthelockIDforthelocktobeprogrammed.MarkingthelockitselfwithitsIDnumberisrecommended. • Eachlockcanbeassignedaserialnumberinthiswindow.CheckingthisboxallowstheoptionofenteringaFixedField,whichis alphabetical,andaVariableField,whichisalphanumeric.Ifentered,thisinformationwillbeshownontheaudit. • IfDualCodeisinstalled,User#2isautomaticallyinstalled(seescreen6).Ifinstalled,twocodeswillberequirednotonlytoopenthe lock,buttoaccesstheManagerMenuoptionsaswell. • UserscanonlybeconfiguredontheLogicModuleiftheyhavebeensetupasDeletedinthiswindow.ADeletedUserisausernumber readyforinstallation;aBlockedUserisausernumberthatwillbeunavailableforinstallation.Installedisanautomaticfeatureavailable onlyforUser#2whensettingtheunitupinDualCode. • TimeDelayopenwindowanddelaytimesmaybesetupinthiswindoworfromtheLogicModule. • If,wheninstalled,thereisalockthatwilltakelongerthan4secondstoreachandopen,theuseoftheOpenDeviceisrecommended. TheOpenDevicewillholdthesignalgoingtothelockforone(1)minuteoruntiltheouterdoorhasbeenopenedandtheOpen Devicedepressed.NOTE: Open Device and Duress Alarm cannot work at the same time. • Onceallofthefeaturesforthislockhavebeenselected,savetheset-uptoafileforlateruse.Ifafilehasalreadybeensaved,itmaybe openedfromthiswindowaswell.

Screen1

Screen2

Screen3 Screen4

Page 3: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage3of8

SENDING SET-UP TO THE LOCKThis function requires the use of the Lock Programming Cable (P/N 43098) and a Serial Interface Connector.1.ConnectpowertothelockviatheLogicModuleorsmall/largebatteryboxthroughtheportonthelockmarkedBAT.TheuseofDuracellTM

orEvereadyTMbatteriesisrecommended(seeFigure1).2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upSoftware.3.Plugthe43098cableintothelockthroughtheportonthelockmarkedENT.4.SelectthelockIDforthelocktobeprogrammed.ItisagoodideatomarkthelockitselfwithitsIDnumber.5.PresstheSendbuttononthesoftwareandthentheStartbutton(seeScreen7).6.OnthescreenthesoftwarewillscrollthrougheachRecordNumber(1-12)asitdownloadstothelock,thenitwillshowOK.7.Repeatsteps3-6foreachlocktobeprogrammedwiththisconfiguration.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.

ENTBAT

DEPRESSFOR PLUG

INSTALLATION

Screen5 Screen6

Figure1 Screen7

Page 4: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage4of8

CONTROL UNIT (LOGIC MODULE) SET-UPTosetupthelogicmodule,clickontheControlUnitSet-upbuttonontheopeningscreen(seeScreen8).Awindowwiththedefaultconfigurationwillappear(seescreen9).InthiswindowselectthefeaturestobeenabledontheLogicModule. • EncryptioncanbeseteitherONorOFF.ThedefaultissetforOFF.CAUTION: If encryption is set ON, once the locks have been installed to this Logic Module, this will be the only Logic Module able to be used with these locks. • HemisphereissetwithadefaultforNORTH.SelecttheHemispherewheretheunitswillbeactive. • TheDallas®key(eKEYII)optioncanbeselectedonthispage.ChecktheYESbox,thenselectwhichlockstosetupforusewitheKEYII, (seeScreen10). • DelayCountingDisplayissettoadefaultofCountdown.AvailableoptionsaretohaveTimeDelaycountingsequenceCountUp, CountDownorNotDisplayed. • TheTDMINwindowallowstheentryofaminimumTimeDelayvalue.Oncethisnumberisentered,Managershavingaccesstothetime menuwillnotbeabletochangetheTimeDelayvaluebelowthisminimumdelayperiodnumber.ThisfeaturewillprogramALLlockson thesystemthathaveaTimeDelayset-up. • MultipleTimeLockperiodsareavailablebycheckingtheboxmarkedMultiTLActive(seescreen11).IfthereisnocheckintheMultiTL Activebox,anytimelockperiodsprogrammedwillapplytoalllocksenrolledinthesystem.ForadifferentTimeLockperiodtoapplyto aspecificlock,checktheMultiTLActivebox.ThelocksenrolledinthesystemmaybesettoTimeLockperiod1,2orNoTimeLock. • OpenExtensionissettoNObydefault.Withthisoption,noonewillhaveaccesstotheOpenExtensionTimeMenuontheLogic Module.SelectingYESallowstheManagerand/orUsers(asselectedinthenextoption)toaccesstheTimeLockOpenExtensionmenu ontheLogicModule.ThosewhohaveaccesscanthenextendtheTimeLockOpenPeriodin30minuteincrements,butnomorethan twohoursorfour(4)30minuteincrements. • TimeMenuAccessallowsyoutoselectwhetherboththeManagerandtheUsersortheManageronlywillhaveaccesstothe TimeMenu. • TheLockInstallationCode(5-0-5-0-5-0)isusedtoenrollthelockstotheLogicModuleduringSystemSet-upusingtheMasterMenuon theLogicModule.Onceallofthefeaturesforthislockhavebeenselected,savetheset-uptoafileforlateruse.Ifafilehasalreadybeensaved,itmaybeopenedfromthiswindowaswell.

Screen8

Screen10 Screen11

Screen9

Page 5: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage5of8

SENDING SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097) and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery.)DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upSoftware.3.Connectthe43097cabletotheLogicModulethroughtheportonthekeypad.4.PresstheSendbuttononthesoftware(seeScreen12).5.ThesoftwarewillinstructyoutoactivatethePCLinkintheMasterMenuontheLogicModule(seescreen13).NOTE: This reminder screen will display even if PC Link is already activated.6.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”or“SELECTLOCK”whentwoormorelocksareinstalled.7.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”8.EntertheMASTERcode.9.Pressthe“P”buttonfour(4)timestoselectPCLink;thedisplaywillshow“PCLINK”.PresstheOKbuttontostartcommunicationwith thePC.10. OnthescreenthesoftwarewillscrollthrougheachRecordnumberasitdownloads,thenitwillshowOK. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”pressthe“OK”button toexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.

DST (Daylight Savings Tine) SET-UPThis function requires the use of the Logic Module Programming Cable (P/N 43097), PC, DST Update Software and a Serial Interface Connector.1.Toset-upDST,clickontheDSTicononthePCdesktop.Theset-upwindowwillappear(seeScreen14).Inthiswindow,setuptheDST datesorselectfromthepre-setfilesavailable.Apre-setfilehasbeencreatedfortheUSA.2.ClickFilefromthemenubar,thenOpen.3.SelectthefilemarkedUSA.DATandclickOpen(seeScreen15). • Thedateswillautomaticallybefilledinforthenext15years(seeScreen16).NOTE: This program will also allow the DST file to be deleted from a previously programmed Logic Module in the event the Module must operate in a state not having DST.

Screen12

Screen14 Screen16Screen15

Screen13

Page 6: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage6of8

SENDING DST (Daylight Savings Tine) SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097), PC, DST Update Software and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery).DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandthenconnectthe43097cabletotheLogicModulethroughtheportonthekeypad.3.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”orSELECTLOCK”whentwoormorelocksareinstalled.4.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”.EntertheMASTERcode.5.Pressthe“P”buttonfour(4)timestoselectPCLink,thedisplaywillshow“PCLINK”6.PresstheSendbuttononthesoftware. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”,pressthe“OK” buttontoexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.

TIME LOCK SET-UPTosetupTimeLock,clickontheTimeLockbuttonontheopeningscreen(seeScreen8).Awindowwiththedefaultconfigurationwillappear(seeScreen17).Thiswindowallowstheset-upofStandardWeekandSpecialEventsTimeLock.ItispossibletosetuptwodifferentTimeLockperiods.

STANDARD WEEK1.SelectTimeLock1. • Select“Add”,“Delete”or“DeleteAll”byright-clickingthecursorinthefirstlineontheStandardWeekscreen(seeScreen18).2.Select“Add”tosetupthefirstTimeLockperiod.“MONfrom08:00to08:00”willautomaticallybeentered. • ClickingintheDayboxineithertheOpenorClosedareawillproduceascrollmenuforselectingthedayoftheweekfortheTime Lockperiod.3.ToentertheOpenTime,highlighttheTimeboxintheOpenareaandenterthetimeusinga24-hourclock.4.ToentertheClosetime,highlighttheTimeboxintheClosedareaandenterthetimeusinga24-hourclock. • Oncethefirstday’sTimevalueshavebeenentered,youwillbeaskedwhetherornotyouwishtocompletetherestoftheweek(see Screens19and20).NOTE: If the choice is made to not automatically complete the rest of the week, enter the daily Time Lock values in any day order and press the green Step button to sort the records by day.5.SavethisTimeLockconfigurationasTimeLock1andthecompanyname.6.SelectTimeLock2andrepeatsteps2-5.CAUTION: Any day not completed will be considered a day in Time Lock and the units will be unavailable on that day.

Screen17 Screen18

Page 7: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage7of8

TIME LOCK SET-UP EXAMPLES • Lockavailable7daysaweekduringbusinesshours-inthiscasebusinesshoursare8amto8pm7daysaweek.(seeScreen20). • Lockavailable6daysaweekduringbusinesshours-inthiscasebusinesshoursare8amto8pm6daysaweek,closedonSunday(see Screen21). • Locksetformultipletimelockperiodsinoneday.Setfor5days,closedSaturdayandSunday(seeScreen22).

SENDING TIME LOCK SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097) and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery.)DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upsoftware.3.Connectthe43097cabletotheLogicModulethroughtheportonthekeypad.4.OpenthecorrectfilefortheTimeLockperiod(1or2)thatwillbedownloadedtothislock.5.PresstheSendbuttononthesoftware(seeScreen23). • ThesoftwarewillinstructyoutoactivatethePCLinkintheMasterMenuontheLogicModule(seeScreens23&24).6.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”orSELECTLOCK”whentwoormorelocksareinstalled.7.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”8.EntertheMASTERcode.9.Pressthe“P”buttonfour(4)timestoselectPCLink;thedisplaywillshow“PCLINK”.PressOKtostartcommunicationwiththePC.10. OnthescreenthesoftwarewillscrollthrougheachRecordnumberasitdownloads,thenitwillshowOK. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”,pressthe“OK” buttontoexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.

Screen19

Screen21

Screen20

Screen22

Page 8: SMARTLINC - Locksmith Reference · • Selectable for each lock - Time Lock 1, Time Lock 2 or No Time Lock • Standard Week (4 open periods per day) • Special Events (up to 20

©copyright2005 (P/N)12-249v2•9/08 Kaba Mas LLCpage8of8

SPECIAL EVENTS SET-UPTosetupSpecialEvents,clicktheTimeLockbuttonontheopeningscreen(seeScreen8).Awindowwiththedefaultconfigurationwillappear(seeScreen17).Thiswindowallowstheset-upofStandardWeekandSpecialEventsTimeLock.

SPECIAL EVENTS • Byright-clickingwiththecursorinthefirstlineontheSpecialEventsscreen,select“Add”,“Delete”or“DeleteAll”(seeScreen25). • Selectthefirstboxandselect“Add”tosetupthefirstSpecialEventperiod.SelectthecorrectDayandDate(1,July)fromthedrop- downmenufortheClosedTime.ThenselectthecorrectDayandDatefromthedrop-downmenufortheOpenTime(seeScreen26). • UptotwentySpecialEventsmaybeadded(amaximumoffourweeks)foreachyear.NOTE: Special Events will repeat each year on that Calendar date. Floating Holidays, i.e. Thanksgiving, Labor Day, etc. cannot be programmed.

SENDING SPECIAL SET-UP TO THE LOGIC MODULEThis function requires the use of the Logic Module Programming Cable (P/N 43097) and a Serial Interface Connector.1.ConnectpowertotheLogicModule.(Requirestheuseofa9Vbattery.)DuracellTMorEvereadyTMbatteriesarerecommended.2.PlugInterfaceandcableintoPCandopenSMARTLINCSet-upsoftware.3.Connectthe43097cabletotheLogicModulethroughtheportonthekeypad.4.PresstheSendbuttononthesoftware(seeScreen23).5.ThesoftwarewillinstructyoutoactivatethePCLinkintheMasterMenuontheLogicModule(seeScreens23&24).6.PressanykeytopowerupSMARTLINC. • Displaywillshoweither“ENTERCOMBO”orSELECTLOCK”whentwoormorelocksareinstalled.7.Holddown“zero”untilthedisplayshows“MASTER,X-X-X-X-X-X-X-X”8.EntertheMASTERcode.9.Pressthe“P”buttonfour(4)timestoselectPCLink;thedisplaywillshow“PCLINK”.PressOKtostartcommunicationwiththePC.10. OnthescreenthesoftwarewillscrollthrougheachRecordnumberasitdownloads,thenitwillshowOK. • InordertoexitfromPCLink,pressthe“P”buttonthree(3)times.Whenthescreenreads“DoyouwanttoQUIT?”,pressthe“OK” buttontoexit.NOTE: If the computer does not have a serial port, a serial to USB connector will be required.

TROUBLESHOOTINGTransmission Error• Acommunicationerror(checkcableandbatteryconnectionsand/orre-startSet-upapplication)• Thelockisnotinpre-setupmode(resetthelockwiththeresetbox)LAGARDP/N6066

No Answer• Acommunicationerror(checkcableandbatteryconnectionsand/orre-startSet-upapplication)• CheckCOMportsetting.TryselectingadifferentCOMportandretry.• SMARTLINCisnotinPC-Linkmode(ActivatePCLinkinMastermenu)

Screen23 Screen24