shoptek™ voltage conversion tek/manual... · shoptek™ voltage conversion • follow all lock...

8
ShopTek™ Voltage Conversion Follow all Lock Out Tag Out procedures 5-10 HP 230V to 460V Kit 02250182-189 15-20HP 230V to 460V Kit 02250182-190 Motor connection diagrams are on the motors or inside cover of motor connection box. Main motor and fan motor need to be rewired. Reconnect transformer for proper incoming voltage.

Upload: others

Post on 30-Jan-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

ShopTek™ Voltage Conversion

• Follow all Lock Out Tag Out procedures• 5-10 HP 230V to 460V Kit 02250182-189• 15-20HP 230V to 460V Kit 02250182-190• Motor connection diagrams are on the

motors or inside cover of motor connection box. Main motor and fan motor need to be rewired.

• Reconnect transformer for proper incoming voltage.

• To complete the 460 Volt conversion the distributor must change the wiring configuration in the fan & main motor Junction box.

• Due to the placement of the junction box for fan it is difficult to access the wires properly.

• The following 4 steps are suggested to make this a quick retrofit in the field.

Step 1 – Lock out power to the compressor, close the discharge valve and relieve any pressure to the

compressor. Remove the top panels and disconnect the air intake line to the aftercooler.

Step 2 – lift cooler and place a holder to prop the cooler into position

Step 3 – Remove center bolt on the fan. This is a left handed thread so rotate the bolt

clockwise and remove the fan blade.

Step 4 – Remove the 4 bolts holding the fan motor to the fan guard and rotate the motor 90 degrees so the junction box is facing the center of

the compressor package. Change the wiring based upon the instructions inside the cover of the junction box.

Before

AfterYou may want to rotate the motor connection box so the cabling to the

electrical enclosure fits and is not stretched or kinked.