housing estates with 8 semi-detached houses. 1 … · semi-detached house 2 semi-detached house 8...

3
299 HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 EXTERNAL POINT OF ENTRY (GATE) WITH AUDIO DIGITAL SYSTEM 4+COAXIAL Standard wiring diagram for digital electronic video door entry installations in housing estates with 8 semi-detached houses, with one entry with video system in each house, and an external point of entry or gate used by all 8 houses. This gate has an audio system (but not a camera). Remarks Identifying the entrance panels of the semi-detached houses In order for communication to be established with one of the dwellings from the entrance panel at the external point of entry and, at the same time, to establish communication with another dwelling from the entrance panel of this dwelling, one estate identifying accessory, model AIB-000, is used per dwelling. Consecutive numbers are assigned to the AIB-000 accessories, beginning with the number '1'. Determining the main entrance panel Both the entrance panel at the external point of entry and the entrance panel of each semi-detached house are configured as main panels (J1 jumper inserted). Programming the connection brackets of each semi-detached house The connections bracket in each semi-detached house is programmed from the entrance panel of this semi-detached house. See Chapter 7. Note: The two pushbuttons of each entrance panel are connected to terminals '1' and '2' of the AIB-000 accessory respectively. Hence, the connection brackets are programmed with the digital code '1' or '2'. SINGLE-WIRED DIAGRAM ABR-011 (1) 2 2 2 2 2 2 ABR-015 (1) 2 2 ALC-041 (230 V ) 2 MVB-002 MVC-002 + SCM-030 SEMI-DETACHED HOUSE 1 MVB-002 MVC-002 + SCM-030 KVD-47101 KVD-47201 + AIB-000 ABR-015 (1) 2 2 ALC-041 (230 V ) 2 MVB-002 MVC-002 + SCM-030 MVB-002 MVC-002 + SCM-030 KVD-47101 KVD-47201 + AIB-000 ABR-015 (1) 2 2 ALC-041 (230 V ) 2 MVB-002 MVC-002 + SCM-030 MVB-002 MVC-002 + SCM-030 KVD-47101 KVD-47201 + AIB-000 EXTERNAL POINT OF ENTRY MAN-470 + MPD-008 + COL-000 x 2 + CMO-008 SEMI-DETACHED HOUSE 2 SEMI-DETACHED HOUSE 8 230V~ ++ ALC-070 (230 V ) 230V~1 2 230V~1 2 230V~1 2 17 SECTION TABLE Up to 100 metres 1.1 mm AWG 1 mm 2 COAXIAL 75 Ω Up to 25 metres 1 mm 2 1.1 mm 17 0.5 mm 2 0.8 mm 20 (1) Max. 15 Vdc, 0.5 A 2 2 COAX 2 2 2 2 2 2 COAX 2 2 2 2 2 2 COAX 2 2 2 2 OBSOLETE

Upload: others

Post on 08-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 … · semi-detached house 2 semi-detached house 8 230v~ ++ alc-070 (230 v ) 230v~ 1 2 230v~ 1 2 230v~ 1 2 17 section table up to 100

299

HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 EXTERNAL POINT OFENTRY (GATE) WITH AUDIODIGITAL SYSTEM 4+COAXIAL

Standard wiring diagram for digital electronic video door entry installations in housing estates with 8 semi-detached houses, withone entry with video system in each house, and an external point of entry or gate used by all 8 houses.

This gate has an audio system (but not a camera).

RemarksIdentifying the entrance panels of the semi-detached houses

In order for communication to be established with one of the dwellings from the entrance panel at the external point of entry and,at the same time, to establish communication with another dwelling from the entrance panel of this dwelling, one estate identifyingaccessory, model AIB-000, is used per dwelling. Consecutive numbers are assigned to the AIB-000 accessories, beginning with thenumber '1'.

Determining the main entrance panel Both the entrance panel at the external point of entry and the entrance panel of each semi-detached house are configured as main

panels (J1 jumper inserted).

Programming the connection brackets of each semi-detached houseThe connections bracket in each semi-detached house is programmed from the entrance panel of this semi-detached house. See

Chapter 7.Note: The two pushbuttons of each entrance panel are connected to terminals '1' and '2' of the AIB-000 accessory respectively.

Hence, the connection brackets are programmed with the digital code '1' or '2'.

SINGLE-WIRED DIAGRAM

ABR-011(1)

2

2

2 2 2

2

ABR-015(1)

2

2

ALC-041(230 V )

2

MVB-002MVC-002

+SCM-030

SEMI-DETACHED HOUSE 1

MVB-002MVC-002

+SCM-030

KVD-47101KVD-47201

+AIB-000

ABR-015(1)

2

2

ALC-041(230 V )

2

MVB-002MVC-002

+SCM-030

MVB-002MVC-002

+SCM-030

KVD-47101KVD-47201

+AIB-000

ABR-015(1)

2

2

ALC-041(230 V )

2

MVB-002MVC-002

+SCM-030

MVB-002MVC-002

+SCM-030

KVD-47101KVD-47201

+AIB-000

EXTERNAL POINT OF ENTRY

MAN-470+

MPD-008+

COL-000 x 2+

CMO-008

SEMI-DETACHED HOUSE 2 SEMI-DETACHED HOUSE 8

230V~ ++

ALC-070 (230 V )

230V~ 1 2 230V~ 1 2230V~ 1 2

17

SECTION TABLE

Up to 100 metres

1.1 mm

AWG

1 mm2

COAXIAL 75 Ω

Up to 25 metres

1 mm2 1.1 mm 17

0.5 mm2 0.8 mm 20

(1) Max. 15 Vdc, 0.5 A

2 2COAX

2

2

2

2

2 2COAX

2

2

2

2

2 2COAX

2

2

2

2

OBSOLETE

Page 2: HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 … · semi-detached house 2 semi-detached house 8 230v~ ++ alc-070 (230 v ) 230v~ 1 2 230v~ 1 2 230v~ 1 2 17 section table up to 100

300

ABR-011

COL-000

cod. 9730030

IN

1413

1012

1116

915

76

24

35

81

CO

L-000

230 V

Semi-detached houses

External point of entryM

ain entrance panel

COL-000

cod. 9730030

IN

1413

1012

1116

915

76

24

35

81

ALC

-070

Earth

19

J1

GRF-208

IN

J2

D3D2

D17

18SC1

2211

109

12

J1_+

230V~++

76

24

35

81

12

12

12

12

12

12

12

12

SEMI-D

ETAC

HED

HO

USE 1

SEMI-D

ETAC

HED

HO

USE 2

SEMI-D

ETAC

HED

HO

USE 3

SEMI-D

ETAC

HED

HO

USE 4

SEMI-D

ETAC

HED

HO

USE 5

SEMI-D

ETAC

HED

HO

USE 6

SEMI-D

ETAC

HED

HO

USE 7

SEMI-D

ETAC

HED

HO

USE 8

WIRED DIAGRAM OF THE EXTERNAL POINT OF ENTRY

HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 EXTERNAL POINT OFENTRY (GATE) WITH AUDIODIGITAL SYSTEM 4+COAXIAL

OBSOLETE

Page 3: HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 … · semi-detached house 2 semi-detached house 8 230v~ ++ alc-070 (230 v ) 230v~ 1 2 230v~ 1 2 230v~ 1 2 17 section table up to 100

301

Detail of num

berassigning of the A

IB-000(num

ber 1)

Detail of num

berassigning of the A

IB-000(num

ber 2)

Detail of num

berassigning of the A

IB-000(num

ber 8)

Point of entry

ALC

-041

MVB-002

MVC

-002+

SCM

-030

ABR-015

ALC

-041

230 V

230 V

External point of entryA

BR-015N

ote: Make the sam

e connectionsat all the sem

i-detached houses

SEMI-D

ETAC

HED

HO

USE 1

R1

CC1

J1

SCM

-030

J1A

B

R1

AJ1

V1V1252627 24 MS5 MS2

D1D2

R1

CC1

J1

SCM

-030

J1A

B

R1

AJ1

V1V1252627 24 MS5 MS2

D1D2

MVB-002

MVC

-002+

SCM

-030

ALC

-041

MVB-002

MVC

-002+

SCM

-030

ABR-015

230 V

MVB-002

MVC

-002+

SCM

-030

KVD-47101

KVD-47201+

AIB-000

KVD-47101

KVD-47201+

AIB-000

19

J1J2

GRF-200

230V~1

2230V~

12

Red

TCB-011

White

75 Ohm

+_

19

V2V2

MM

V1V4

MM

12

230 V1

2

12

34

56

78

SW1

4433

2211

12

34

56

78

SW1

4433

2211

910

1222

SC17

D1D2D311

+8

12

34

56

7

J1

J1J1

AIB-000

1

12

34

56

78

SW1

18O

UT

D1D5

D4D3

D2D2

AIB-000

cod. 9730014

OUT

43

21

V

43

21

18D2

D3D4

D5D2

D1V~

12

34

56

78

SW1

4433

2211

SEMI-D

ETAC

HED

HO

USE 2

SEMI-D

ETAC

HED

HO

USE 8

Red

White

19

+19

WIRED DIAGRAM OF THE SEMI-DETACHED HOUSES