housing estates with 8 semi-detached houses. 1 … · semi-detached house 2 semi-detached house 8...
TRANSCRIPT
299
HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 EXTERNAL POINT OFENTRY (GATE) WITH AUDIODIGITAL SYSTEM 4+COAXIAL
Standard wiring diagram for digital electronic video door entry installations in housing estates with 8 semi-detached houses, withone entry with video system in each house, and an external point of entry or gate used by all 8 houses.
This gate has an audio system (but not a camera).
RemarksIdentifying the entrance panels of the semi-detached houses
In order for communication to be established with one of the dwellings from the entrance panel at the external point of entry and,at the same time, to establish communication with another dwelling from the entrance panel of this dwelling, one estate identifyingaccessory, model AIB-000, is used per dwelling. Consecutive numbers are assigned to the AIB-000 accessories, beginning with thenumber '1'.
Determining the main entrance panel Both the entrance panel at the external point of entry and the entrance panel of each semi-detached house are configured as main
panels (J1 jumper inserted).
Programming the connection brackets of each semi-detached houseThe connections bracket in each semi-detached house is programmed from the entrance panel of this semi-detached house. See
Chapter 7.Note: The two pushbuttons of each entrance panel are connected to terminals '1' and '2' of the AIB-000 accessory respectively.
Hence, the connection brackets are programmed with the digital code '1' or '2'.
SINGLE-WIRED DIAGRAM
ABR-011(1)
2
2
2 2 2
2
ABR-015(1)
2
2
ALC-041(230 V )
2
MVB-002MVC-002
+SCM-030
SEMI-DETACHED HOUSE 1
MVB-002MVC-002
+SCM-030
KVD-47101KVD-47201
+AIB-000
ABR-015(1)
2
2
ALC-041(230 V )
2
MVB-002MVC-002
+SCM-030
MVB-002MVC-002
+SCM-030
KVD-47101KVD-47201
+AIB-000
ABR-015(1)
2
2
ALC-041(230 V )
2
MVB-002MVC-002
+SCM-030
MVB-002MVC-002
+SCM-030
KVD-47101KVD-47201
+AIB-000
EXTERNAL POINT OF ENTRY
MAN-470+
MPD-008+
COL-000 x 2+
CMO-008
SEMI-DETACHED HOUSE 2 SEMI-DETACHED HOUSE 8
230V~ ++
ALC-070 (230 V )
230V~ 1 2 230V~ 1 2230V~ 1 2
17
SECTION TABLE
Up to 100 metres
1.1 mm
AWG
1 mm2
COAXIAL 75 Ω
Up to 25 metres
1 mm2 1.1 mm 17
0.5 mm2 0.8 mm 20
(1) Max. 15 Vdc, 0.5 A
2 2COAX
2
2
2
2
2 2COAX
2
2
2
2
2 2COAX
2
2
2
2
OBSOLETE
300
ABR-011
COL-000
cod. 9730030
IN
1413
1012
1116
915
76
24
35
81
CO
L-000
230 V
Semi-detached houses
External point of entryM
ain entrance panel
COL-000
cod. 9730030
IN
1413
1012
1116
915
76
24
35
81
ALC
-070
Earth
19
J1
GRF-208
IN
J2
D3D2
D17
18SC1
2211
109
12
J1_+
230V~++
76
24
35
81
12
12
12
12
12
12
12
12
SEMI-D
ETAC
HED
HO
USE 1
SEMI-D
ETAC
HED
HO
USE 2
SEMI-D
ETAC
HED
HO
USE 3
SEMI-D
ETAC
HED
HO
USE 4
SEMI-D
ETAC
HED
HO
USE 5
SEMI-D
ETAC
HED
HO
USE 6
SEMI-D
ETAC
HED
HO
USE 7
SEMI-D
ETAC
HED
HO
USE 8
WIRED DIAGRAM OF THE EXTERNAL POINT OF ENTRY
HOUSING ESTATES WITH 8 SEMI-DETACHED HOUSES. 1 EXTERNAL POINT OFENTRY (GATE) WITH AUDIODIGITAL SYSTEM 4+COAXIAL
OBSOLETE
301
Detail of num
berassigning of the A
IB-000(num
ber 1)
Detail of num
berassigning of the A
IB-000(num
ber 2)
Detail of num
berassigning of the A
IB-000(num
ber 8)
Point of entry
ALC
-041
MVB-002
MVC
-002+
SCM
-030
ABR-015
ALC
-041
230 V
230 V
External point of entryA
BR-015N
ote: Make the sam
e connectionsat all the sem
i-detached houses
SEMI-D
ETAC
HED
HO
USE 1
R1
CC1
J1
SCM
-030
J1A
B
R1
AJ1
V1V1252627 24 MS5 MS2
D1D2
R1
CC1
J1
SCM
-030
J1A
B
R1
AJ1
V1V1252627 24 MS5 MS2
D1D2
MVB-002
MVC
-002+
SCM
-030
ALC
-041
MVB-002
MVC
-002+
SCM
-030
ABR-015
230 V
MVB-002
MVC
-002+
SCM
-030
KVD-47101
KVD-47201+
AIB-000
KVD-47101
KVD-47201+
AIB-000
19
J1J2
GRF-200
230V~1
2230V~
12
Red
TCB-011
White
75 Ohm
+_
19
V2V2
MM
V1V4
MM
12
230 V1
2
12
34
56
78
SW1
4433
2211
12
34
56
78
SW1
4433
2211
910
1222
SC17
D1D2D311
+8
12
34
56
7
J1
J1J1
AIB-000
1
12
34
56
78
SW1
18O
UT
D1D5
D4D3
D2D2
AIB-000
cod. 9730014
OUT
43
21
V
43
21
18D2
D3D4
D5D2
D1V~
12
34
56
78
SW1
4433
2211
SEMI-D
ETAC
HED
HO
USE 2
SEMI-D
ETAC
HED
HO
USE 8
Red
White
19
+19
WIRED DIAGRAM OF THE SEMI-DETACHED HOUSES