Series V7 Paddle Flow Switch
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc.
©Copyright 2011 Dwyer Instruments, Inc
![Page 2: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/2.jpg)
V7 Flow Switch
Flow switch to meet boiler code pressure and temperature requirementsApproved to UL 353
Safety device ratingV7 web page has link to the file
![Page 3: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/3.jpg)
Where it Fits
The V10 and V8 do not meet boiler code pressure and temperature ratingsThe V6 does meet but is too expensiveSo the V7 fits that gap
![Page 4: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/4.jpg)
Models
![Page 5: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/5.jpg)
Pipe Sizes
It can be used over 4” pipeWe can set up specials in tees and preset for large quantities
![Page 6: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/6.jpg)
Specifications
Wetted Materials: 301 SS, 302 SS, ceramic magnet, body: brass or 316 SSTemperature Limits: -40 to 121 ̊ CPressure Limits: 17.2 barEnclosure Rating: IP66Switch Type: SPDTElectrical Rating: 10A @ 125, 250, 480 VAC
![Page 7: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/7.jpg)
Specifications
Conduit Connection: 1/2” NPSMProcess Connection: 1” male NPTMounting Orientation: Horizontal or vertical No vertical down flowSet Point Adjustment: Vane is trimmableAgency Approvals: CE, UL 353
![Page 8: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/8.jpg)
Selling Points
Key Selling PointsMagnetic Switch Mechanism
Superior to direct drive – no wear or leaks
Stronger VaneVery common to have vanes break on competitor units
![Page 9: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/9.jpg)
Selling Points
Key Selling PointsIntegral weatherproof housing
Competitors are general purpose with weather-proof optionalOften used for pool boilers as installed outside
![Page 10: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/10.jpg)
Other Items
Standard this has the same vane as the V6, but we can put in the V10 vane too
Some customers prefer the reinforced vane
![Page 11: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/11.jpg)
Key Application
All boilers require safety devices according to ASME code
Can be flow, level, pressure, temperature depending on boiler typeVery common to be a flow switch on the water outlet
![Page 12: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/12.jpg)
Applications
Copper fin boilersAlways use a flow switch on the hot water outlet to shut down boiler with loss of flow
Common on commercial hot water heaters
![Page 13: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/13.jpg)
V7 Boiler Example
![Page 14: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/14.jpg)
Applications
General flow provingPump proving
IrrigationBuilding Automation Systems
Leak proving
![Page 15: Series V7](https://reader033.vdocuments.us/reader033/viewer/2022060111/55693468d8b42add468b4ff4/html5/thumbnails/15.jpg)
Questions
To order a free catalog or for more information contact;Dwyer Instruments, Inc., P.O. Box 373,
Michigan City, IN., 46361Telephone: (800) 872-9141 or (219) 879-8000
Fax: (219) 872-9057Internet address: www.dwyer-inst.com
E-mail: [email protected]