sdc electric strikes, magnetic locks, electric door …...1512 electromagnetic door lock psb560 rex...

2
Convenience Store Safety After-Hour Store Front Security Solution 1512 Electromagnetic Door Lock PSB560 REX Pressure Sense Bar 1511 Electromagnetic Door Lock 801N Key Switch UB11 or UB12 Universal Header Brackets 631RF 1.5 Amp Power Supply EA100 Multi-Mode Exit Annunciator Concealed Switch 15-2 WRC Transmitter & Receiver • Employee Lockdown Protection • Customer Safety • Prevent Robbery • Reduce Liability Double Housing- Pair Doors Holding Force- 1650 lbs. UL Listed, 12/24 VDC Clear Anodized Aluminum Optional Monitoring Releasing Device Slim Profile Includes Transfer Loop UL Listed Single Door Holding Force- 1650 lbs. UL Listed, 12/24 VDC Clear Anodized Aluminum Optional Monitoring Vandal Resistance Aluminum Narrow Frame Mount SPDT, ON/OFF Key Cylinder-Optional Mounting Header Bracket Predrilled and Tapped Clear Anodized Aluminum Install Labor Savings For 4” or 4.5” Aluminum Header 12/24 VDC, 1.5 Amp Regulated and Filtered Emergency Release Input UL Listed Batteries Optional Visual Multicolor Signal Wall, Ceiling, Frame Mount 12/24 VDC, Voltage Counter Mount SPDT, Momentary Wireless Fob Transmitter Two Buttons Two Channel Receiver LOCKING SOLUTION OPTIONS ACCESS CONTROL COMPONENTS 1a 3 1b 4 1c 5 2 6a WRC-R2 WRC-2B The lock behind your system (800) 413-8783 WWW.SDCSECURITY.COM

Upload: others

Post on 24-Aug-2020

23 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SDC Electric Strikes, Magnetic Locks, Electric Door …...1512 Electromagnetic Door Lock PSB560 REX Pressure Sense Bar 1511 Electromagnetic Door Lock 801N Key Switch UB11 or UB12 Universal

Convenience Store SafetyAfter-Hour Store Front Security Solution

1512 Electromagnetic Door Lock PSB560 REX Pressure Sense Bar

1511 Electromagnetic Door Lock 801N Key Switch

UB11 or UB12 Universal Header Brackets 631RF 1.5 Amp Power Supply

EA100 Multi-Mode Exit Annunciator Concealed Switch 15-2 WRC Transmitter & Receiver

• Employee Lockdown Protection• Customer Safety • Prevent Robbery• Reduce Liability

• Double Housing- Pair Doors• Holding Force- 1650 lbs.• UL Listed, 12/24 VDC• Clear Anodized Aluminum• Optional Monitoring

• Releasing Device• Slim Profile• Includes Transfer Loop• UL Listed

• Single Door• Holding Force- 1650 lbs.• UL Listed, 12/24 VDC• Clear Anodized Aluminum• Optional Monitoring

• Vandal Resistance• Aluminum Narrow Frame

Mount• SPDT, ON/OFF• Key Cylinder-Optional

• Mounting Header Bracket• Predrilled and Tapped• Clear Anodized Aluminum• Install Labor Savings• For 4” or 4.5” Aluminum Header

• 12/24 VDC, 1.5 Amp• Regulated and Filtered• Emergency Release Input• UL Listed• Batteries Optional

• Visual Multicolor Signal• Wall, Ceiling, Frame Mount• 12/24 VDC, Voltage

• Counter Mount• SPDT, Momentary

• Wireless Fob Transmitter• Two Buttons• Two Channel Receiver

LOCKING SOLUTION OPTIONS ACCESS CONTROL COMPONENTS

1a 3

1b 4

1c 5

2 6a

WRC-R2WRC-2B

The lock behind your system(800) 413-8783 ■ WWW.SDCSECURITY.COM

Page 2: SDC Electric Strikes, Magnetic Locks, Electric Door …...1512 Electromagnetic Door Lock PSB560 REX Pressure Sense Bar 1511 Electromagnetic Door Lock 801N Key Switch UB11 or UB12 Universal

PROJECT NAME:

DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:

SO NO.: REVTITLE:-801 Avenida Acaso

Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com

Convenience Store Safety

--

After-Hour Convenience Store Security Solution Wiring

- [email protected] --10/2016 --

-

© 2016 Security Door Controls Printed in U.S.A

NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.

C NO C NO - NO C NC - NO C NC

- +

TRIG A TRIG B RELAY A RELAY B

w

DA

w

DB

12

34

J1

UR-1

Switch No:

off offPosition SW1 SW2

off

SW3

off

SW4

Dip Switches Set For “CR Mode”

OFF

631RF

BatteryChargerIndicator Fuse

AC PowerLED

PrimaryFuse 250V1.5Amp

BatteryInput

12V

SHORT

OPEN

24V

VOLTAGE SELECT

System StatusLED

NOTE:SET TO 24VDC.

Power must be turned off before changing voltage jumper

G W B

TO 120VAC PRIMARYVOLTAGE CONNECTION

(Remove factory installed jumper only when fire alarm interface is used)

+-

DC Voltage Output

Terminals+ - C

+ -RB12V4

5 AMP HOUR BATTERY

+ -RB12V4

5 AMP HOUR BATTERY

SDC P/N: RB12V4-2(Optional Battery Backup)

Key Switch -Alternate-Action

System Activation (ON/OFF) COM

NO

WHT

YEL

SDC P/N: 801NAL

NC

(Mortise cylinder not included)

ORG

Left Door

C-GRNN/C-BLU

RED(+)

SDC P/N: 631RFXUR-1

1.5 Amp Power Supply w/ Enclosure & Universal Relay Module

SDC P/N: PSB560V

Pressure Sense Bar #1

Right Door

C-GRN

N/C-BLU

SDC P/N: PSB560VPressure Sense Bar #2

(for 1512 Emlock)

PWR

SDC P/N: 432KLDURLatching Push Button

w/ Key Reset

jumper

COM

N/C N/O

COM

N/C

N/O

SDC P/N: 15-2

ConcealedDesk Switch

Momentary Door Release

(HardwiredOption)

BLKRED

GRN

BLU

ORG

WHT

Door StatusLED Annunciator

(above door)GRN = Unlocked

RED = Locked

SDC P/N: EA100

BLK(-)

RED(+)BLK(-)

PowerTransfer

PowerTransfer

Lockdown(w/ Key Switch

Override)

(N/C)(N/C)

(N/O)(N/O)

(N/O)(N/O)

(N/C)(N/C)

DPST

SDC P/N: 1511V (Single)OR 1512V (Double)

LeftDoor

Right Door

EMLock®

Note: Single door application will only have (1) PSB and (1) EMLock terminal board.

System Operation:1. Maglocks shall be manually unlocked during normal business hours by activating the ON/OFF key switch.

2. After hours, maglocks may be momentarily de-energized by using the concealed desk switch or wireless push button.

3. Pressure sense exit bars on each door will allow free egress at all times.

4. An LED annunciator located above the door will show the energized/de-energized status of the maglocks.

5. Activation of the Lockdown Button will instantaneously energize the maglocks. The key switch, desk switch & wireless release will be bypassed, and doors will remain locked until the lockdown button is reset by key.

Prog. Status LED

Wiring Pigtail Connector

LearningButton

RED (+24VDC)BLK (GND)

GRN (Relay 1 - NC)ORG (Relay 1 – Com)YEL (Relay 1 – N/O)

Relay 1Relay 2

C B A C B A + (-)

M

L

3S

PwrIn

SDC P/N: WRC-R2

Momentary Door Release

(WirelessOption)

RF Receiver