General program features
Graphical designing of new central heating installations.
Hydronic balancing of already existing central heating installations.
Designing systems of pipes in ice-water installations.
Graphical designing of underfloor heating installations.
-
7/30/2019 Sankom Ch Overview
3/20
Central heating installation criteria
Pump installation .
Two-pipe system . Upper- or bottom division, vertical pipes distribution systems, manifold
systems .
Convection or Underfloor radiators .
Automatic air bleeders (no de-aerating grid present) .
Normal or thermostatic radiator valves .
Initial regulation by valves with initial preset or orifices .
Differential pressure balancing by balancing stabilisers .
Possibility of using flow governors .
-
7/30/2019 Sankom Ch Overview
4/20
Hydraulic calculations
Adjustment of diameters of pipes.
Estimation of hydraulic resistance for individual circuits, taking into account
gravity pressure, resulting from water cooling in pipes and heat receivers.
Reduces overpressure in circuits by adjusting initial presets of valves with
double control, or adjustment of aperture diameters for balancing orifices.
Takes into account necessity of ensuring the relevant hydraulic resistance of
pipe-run with heat receiver (pgmin). Adjustment of presets for differential pressure governors installed in
positions selected by designer (risers base, installations branch, etc.).
Adjustment of presets for differential pressure governors installed in
positions selected by designer (risers base, installations branch, etc.).
Automatically takes into account requirements on authorities for
thermostatic valves (appropriate pressure drop on valves).
-
7/30/2019 Sankom Ch Overview
5/20
Heat calculations
Estimation of heat gains from pipes of installation led in individual rooms.
Calculation of cooling for heating agent in pipes .
Estimation of required radiators dimensions for given heat load demand.
Adjustment appropriate flux of heating agent inflowing heat receivers, taking
into account its cooling in pipes and heat gains from pipes (variant of
regulation of existing installation, e.g. in additionally insulated buildings).
Takes into account influence of water cooling in pipes on value of gravity
pressure in individual circuits, as well as on heat load of heat receivers.
Designs underfloor radiators
-
7/30/2019 Sankom Ch Overview
6/20
Basic data
Watertemperatures
Heat surce
parameters
Available
pipes
Includes basic data for whole installation.
Dedicated for the calculation range selection.
Catalogue data
Calculationvariant selection
-
7/30/2019 Sankom Ch Overview
7/20
Radson OZC
Drawing of the installation diagramData are to be entered in graphic form into installation diagram.
Movable toolbars
Two independently scaledviews of the drawing
Drawingfunctions tool bar
Categories for itemsbeing edited
Tables enabling simultaneous editing of
many components of the installation
Drawings presentin the project
Dynamic link of thetable and the drawing
Pull-downbuttons
Pull-down listconfiguration
-
7/30/2019 Sankom Ch Overview
8/20
Radson OZC
Preparing the installation diagram example
+ 3.00
Constructiontab
Scale selection
Radiatorstab
Plateradiators
Pipes tabAccessories tab
KOMPAKT-**600 m
100 %
1Pokj
+20C 1976 /0 W
2Kuchn ia
+20C 429/0 W
dn A 1/3 dn A 1/4
dn A 1/2
V-EXAKT-DTdnV-EXAKT-DTdn
Roomzones
Labels
CeilingCreation
KOMPAKT-**600 m
100 %
-
7/30/2019 Sankom Ch Overview
9/20
Radson OZC
Use of the ready blocks
Copying and Blockstab
Traditionalinstalations
C**-60
0 m
100 %
C**-60
0 m
100 %
1
Pokj+20C 1976/0 W
2
Kuchnia
+20C 429/0
dn A1/3
dn A1/2
dn A1/4
V-EXAKT-DT
dn
V-EXAKT-DT
dn
+ 3.00
+ 6.00
Copy to theRight
0 m
100 %0 m
100 %
1Pokj
+20C 1976/0 W2
Kuchnia+20C 4 29 /0 W
dn A 1/3dn A
1/2dn A 1/4V-EXAKT-DT
dnV-EXAKT-DTdn
+ 3.00
+ 6.00
0 m
100 % 0 m
100 %
3W.C.
+20C 1 10 /0 W4
Sie+16C 2 18 /0 W
dn A 2/3dn A
2/2dn A 2/4V-EXAKT-DT
dnV-EXAKT-DTdn
0 m
100 % 0 m
100 %0 m
100 %0 m
100 %
101Pokj
+20C 1109/0 W102
azienka+25C 507/0 W
103W.C.
+20C 0 /0 W104
Pokj+20C 5 54 /0 W
dn A 1/103 dn A 1/104 dn A 2/103 dn A 2/104
dn A2/102dn A 1/101
V-EXAKT-DTdnV-EXAKT-DTdn V-EXAKT-DTdnV-EXAKT-DTdn
Copy to theUp
Ready blocks
0 m
100 % 0 m
100 %
103W.C.
+20C 0/0 W104Pokj
+20C 554/0 W
dn A 2/103 dn A 2/104
dn A 2/102
V-EXAKT-DTdnV-EXAKT-DTdn
Automaticallyrenumbered rooms Automatically
renumberedpipe-runs
-
7/30/2019 Sankom Ch Overview
10/20
C11-60
0.5 m
500 W
C11-60
0.5 m
500 W
C11-60
0.6 m
700 W
C11-60
0.6 m
700 W
C11-60
0.9 m
1000 W
C11-60
0.9 m
1000 W
3
Pokj+20C 1000 W
PIW
Piwnica
+5C 0 W
4
Kuchnia
+20C 700 W
5
azienka+25C 500 W
103
Pokj+20C 1000 W
104
Kuchnia+20C 700 W105
azienka+25C 500 W
KL
Klatka
+16C 0 W
dn152/3
dn182/1
dn122/6
dn182/4
dn122/9
dn182/7
dn152/10
dn152/103
dn182/101
dn122/106
dn182/104
dn122/109
dn182/107
dn152/110
dn 152/20
dn 20R/1
RTD-K
dn 15 n 3
RTD-K
dn 15 n 3
V2000-D-V
dn 10 n 3
EEM-VM-1
dn15
V2000-D-V
dn 10 n 2.4
V2000-D-V
dn 10 n 3
EEM-VM-1
dn15
V2000-D-V
dn 10 n 2.25
KOMBI-3+ -N
dn 15 n 3.6
KOMBI-3+ -N
dn 15 n 5
Przykad 2
Przykadowy proj
Radson C.O.
The horizontal apartment system
C11-60
0.5 m
500 W
C11-60
0.6 m
700 W
700 W
5
azienka+25C 500 W
dn12
2/9
dn18
2/7
dn15
2/10
RTD-K
dn 15 n 3
V2000-D-V
dn 10 n 2.4
Przykadowy proj
Radson C.O.
Blockvalves
Drawino ofTables
-
7/30/2019 Sankom Ch Overview
11/20
n 2
VKO11-60
0.5 m
500 W
n 2
VKO11-60
0.5 m
500 W
C11-60
0.6 m
C11-60
0.6 m
700 W
C11-60
0.6 m
700 W
C11-60
1 m
C11-60
1 m
1000 W
C11-60
1 m
1000 W
5
Pokj+20C 1000/0 W
4
azienka+25C 500/0 W
3
Kuchnia
+20C 700/0 W
2
PokjC 1000/0 W
105
Pokj+20C 1000/0 W
103
Kuchnia
+20C 700/0 W
102
PokjC 1000/0 W
104
azienka+25C 500/0 W
dn16A
Q1000
1/P005
dn16A
Q500
1/P004
dn16A
Q700
1/P003
dn16A
Q1000
1/P002
dn16A
Q1000
1/P105
dn16A
Q700
1/P103
dn16A
Q1000
1/P102
dn16A
Q1000
dn16A
Q700
dn16A
Q1000
dn16A
Q500
1/P104
dn16A
Q500
RTD-N-P
dn 15 n 4
RTD-N-P
dn 15 n 3.5
P
4
RTD-N-P
dn 15 n 4.5
RTD-N-P
dn 15 n 3.5.5
The manifold apartment system
RadiatorsINTEGRA
-
7/30/2019 Sankom Ch Overview
12/20
Wszystkie przewody izolo
3
C11-60
0.7 m
610 W
GP-MARMUR dn=17 Q=3
Fc=5.7 Lc=28.0 B=0.
Fb=1.1 Lb=3.9 Bb=0.
GP-MARMUR dn=17 Q=1123 W
Fc=15.5 Lc=78.3 B=0.2
Fb=1.1 Lb=8.1 Bb=0.1
MUR dn=17 Q=259 W
3.8 Lc=17.7 B=0.2
-
Fc=2.4 Lc=22.5
-
Fc=0.9 Lc=5.8 B=0.15
O3
Pracown ia
+20C 610 W
1
Pokj
+20C 1728 W
dn17B
1/6
dn17B
1/5
dn 16 AR/7
ZT-PURMO
dn 15
ZT-PURMO
dn 15
Z
V-EXAKT-DT
dn 10 n 3VF-
dn
VF-3-2.5
dn15
ZP-PU
RMO
dn15
n0
ZP-PU
RMO
dn15
n5
The underfloor radiators installation
Underfloorradiator
Mixingmodule
-
7/30/2019 Sankom Ch Overview
13/20
Designing of the underfloor radiators Flexible underfloor radiator construction definition.
Creation of the underfloor radiators catalogue .
Layers above the pipes
Pipe-coilconstruction
Layers below the pipes
-
7/30/2019 Sankom Ch Overview
14/20
Designing of the underfloor radiators Preliminary calculations.
Unitary thermalefficiency
Pipesinformation's
Calculated pipe lengthand floor area
Floortemperature
Calculationstemperatures
Hydrauliccalculations results
-
7/30/2019 Sankom Ch Overview
15/20
Radson C.O.
Drawing on the plan views
KOMPAKT-**-60
GP-MARMUR dn =GP-MARMUR dn =GP-MARMUR dn=GP-MARMUR dn=GP-MARMUR dn =GP-MARMUR dn =GP-MARMUR dn=Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fc=5.7 Lc= B=0.2Fb=1.3 Lb= B b=Fb=1.3 Lb= B b=Fb=1.3 Lb= B b=Fb=1.3 Lb= B b=Fb=1.3 Lb= B b=Fb=1.3 Lb= B b=Fb=1.3 Lb= B b=
5Pokj
+20C 723 W
dn A2/5
Underfloorradiators
Radiators
Pipes
Room labelsGraphic
tabViews tab
Entering then plan viewdrowing form file (wmf,dxf, dwg) or clipboard
Instalation itemlabel
Border
zone
-
7/30/2019 Sankom Ch Overview
16/20
Radson C.O.
The calculation resultsCalculations results may be presented both in table- as in the graphic.
Results in thegraphic form
Results in the
table form
Dynamic link of tableswith the installation
diagram
Valve presetvalue
Radiatorsize
Drawing layersformating
Setting layersvisibility
Layerediting
Line style
Font style selection
-
7/30/2019 Sankom Ch Overview
17/20
Radson C.O.
The calculation results on the plan view
Underfloorradiators Radiators (length scale
is saved)
Describedpipes
-
7/30/2019 Sankom Ch Overview
18/20
The calculation results presentation The contents of all tables can be formatted (choice of rows and columns to
be shown, choice of font size) and sorted according to freely chosen key .
All drawings could be transferred in to another application using WMF,
DXF and DWG format.
In case of the DXF and DWG files the layers and blocks structure a saved.
The contents of all tables can be transferred in to another application via
clipboard.
-
7/30/2019 Sankom Ch Overview
19/20
Plotting of the calculations rusaltsCalculations results can be plotted onto the plotter or printer .Plot preview commandPlot formatting
command
Plottingpagination
Printer or plotter selection
Plotting scale
PlottingMargins
-
7/30/2019 Sankom Ch Overview
20/20
References
Poland
Aquatherm
Comap
Coprax
Herz
Honeywell
IMI
Oventrop
KanRadson
Rettig (PURMO)
UPONOR
Russia
Danfoss
Honeywell
IMI
Kan
Rettig (PURMO)
Vogel & Noot
Czech Republic
Kan