rfid cam lock product guideclockwise direction, open the door close: present the user card / admin...

4
RFID Cam Lock Product Guide Technical Data Dimensions Material Zinc alloy housing and handle Mechanical override key Fixing screws and cam Input Voltage DC3V Battery 2 X AA alkaline batteries Service life 60,000 locking cycles Static Power 100uA Dynamic Power 170mA Use condition Temperature: -15~65℃; Humidity: 5%~95% Features: Works with most Mifare solutions @ 13.56MHz Three level system for user administration Quick and easy operation No external programming devices needed LED in 2 colors for lock status (green/red) Application for metal, wooden and plastic doors Can be used right/left handed on door thickness up to 20mm Handle Induction Area Emergency opening Item No.: PL730 www.qilocks.com [email protected] +44 (0)20 8906 6881

Upload: others

Post on 20-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • RFID Cam Lock Product Guide

    Technical Data

    Dimensions

    Material Zinc alloy housing and handle

    Mechanical override key

    Fixing screws and cam

    Input Voltage DC3V

    Battery 2 X AA alkaline batteries

    Service life 60,000 locking cycles

    Static Power ≤100uA

    Dynamic Power ≤170mA

    Use condition Temperature: -15℃~65℃;

    Humidity: 5%~95%

    Features:

    Works with most Mifare solutions @ 13.56MHz

    Three level system for user administration

    Quick and easy operation

    No external programming devices needed

    LED in 2 colors for lock status (green/red)

    Application for metal, wooden and plastic doors

    Can be used right/left handed on door thickness up to 20mm

    Handle

    Induction Area

    Emergency opening

    Item No.: PL730

    www.qilocks.com [email protected] +44 (0)20 8906 6881

  • Programming Instructions

    I. Overview

    Three card levels are available for the operation of the lock.

    Main-Admin card

    The Main-Admin card is required only when programming and deprogramming Admin cards.

    The Main-Admin card has no locking function

    Admin card

    The Admin card manages the user cards

    The Admin card has an emergency unlock function

    User card

    The User card is made available to users so that they can open and close the door

    User Mode

    Before programming, select the most appropriate function for the application:

    A) Private Use – each user has their own lock that is synced to their user card that will only work with that

    specific lock.

    Note: this is the default factory setting.

    B) Public Use – used for short term, multi user applications. Any card will work with any available lock.

    Note: when locked in public mode a red light will flash every 5 seconds to indicate the locker is in use

    Change from Private use into Public use:

    Hold Main admin card to lock for 1-2 seconds (green light flashes 3 times), then repeat again for 3 seconds until

    green light flashes, setup successfully.

    Repeat the above process to switch back to Private use.

    How to operate the lock

    Open : Present the User card / Admin card to the lock, green light flashes, rotate the handle 90 degrees in a

    clockwise direction, open the door

    Close: Present the User card / Admin card to the lock or wait for 5 seconds after opening, the lock will lock

    automatically, rotate the handle 90 degrees counter clockwise.

    II. Programming RFID cards with the RFID LOCK

    The RFID cards activate various functions when they are presented to the lock.

    Programming Main-Admin cards:

    - Hold the Main-Admin card in front of the lock for 1~2 seconds (green light flashes 3 times) wait approximately

    5 seconds, setup successfully.

    www.qilocks.com [email protected] +44 (0)20 8906 6881

  • Programming Admin cards:

    - Hold the Main-Admin card in front of the lock for 1~2 seconds (green light flashes 3 times), remove the card

    Then hold the Admin card to be programmed in front of the lock for 1~2 seconds. (green light flashes 3 times),

    hold the Main-Admin card again in front of the lock for 1~2 seconds (green light flashes), remove the card; setup

    successfully.

    - Repeat this procedure for all Admin cards that you’d like to program (max. 10 cards).

    - Programming a User card:

    - Hold an Admin card in front of the lock for1~2 seconds. (green light flashes 3 times), remove the card

    - Then hold the user card to be programmed in front of the lock for 1~2 seconds until green light flashes,

    remove the card

    - Repeat this procedure for all user cards that you’d like to program (max. 10 cards).

    III. Deprogramming RFID cards with the RFID LOCK

    What happens if admin or user cards are lost? The following instructions detail how to deprogramme cards in

    order to maintain the security of the locks.

    Deprogramming a Main-Admin card:

    - Reset the lock - remove the battery cover, press the reset button until the lock flash 4 times, then release the

    button, reset successfully.

    Deprogramming individual Admin cards:

    - Hold the Main-Admin card in front of the lock for about

    5 seconds (green light flashes 3 times), until it flashes red one time, remove the card;

    - After that, the Admin card to be deprogrammed is held for approximately 5 seconds in front of the lock (green

    light flashes) until it flashes red twice.

    - Along with the Admin card, all keycards that were programmed with this Admin card will be deprogrammed

    automatically. Keycards that were programmed by other Admin cards will remain valid.

    - Repeat this procedure with all Admin cards that you would like to deprogramme.

    Deprogramming individual user cards:

    - Hold the Admin card that was used to programme the user card to be deprogrammed in front of the lock for

    about 5 seconds. The lock first displays a green flashing light, then it flashes red one time, remove the card;

    - After that, the user card to be deprogrammed is held for approximately 5 seconds in front of the lock until it

    flashes red twice, remove the card

    - Repeat this procedure with all user cards that you would like to deprogram.

    www.qilocks.com [email protected] +44 (0)20 8906 6881

  • Deprogramming all user cards:

    - To deprogram all user cards, hold the Admin card that was used to program the user cards in front of the lock

    for about 5 seconds until it flashes red one time, remove the card; Then hold the Admin card again about 5

    seconds until it flashes red twice, remove the card.

    - All user cards that were programmed with this Admin card will be deprogrammed at the same time. If several

    Admin cards are used, this procedure will have to be carried out separately for each Admin card.

    - The Admin card remains valid.

    III. Additional instructions

    Timeout:

    - The programming or deprogramming mode is terminated when no action is carried out (i.e. the card is

    neither introduced nor removed) for approximately 10 seconds.

    - The programming or deprogramming mode will be stop when the action is incorrect (flashes red)

    - When the RFID lock is unlocked with a user card, the door has to be opened within 5 seconds. otherwise,

    the RFID lock will relock automatically.

    Visual Indications

    - Green light flashing (3 times) for the below cases:

    - 1) The RFID card was recognised, i.e. this card has already been programmed with this particular LOCK.

    - 2) Confirmation that the action (programming or deprogramming) was successfully completed.

    - Red light blinking for the below cases:

    - 1) The RFID card was not recognised, i.e. this card has not yet been programmed with this particular LOCK.

    2) Presented the wrong card when programming or deprogramming

    Public / Private Mode

    When the lock is in private mode there are no visual indications

    When the lock is in public mode locks that are in use will flash red every 5 seconds to show that they are in use

    Emergency Opening

    - Unlock by Admin key if losing the user card or by the mechanical master key. The master key can be used to

    open the lock at any time. This does not affect the lock programming in any way.

    Low battery alarm

    -The alarm will sound if the battery is low and the LED will flash red 5 times warning users to replace the battery

    soon.

    Changing the Battery

    1. Remove fixing screw

    2. Rotate the lock down over the edge of door

    3. Take out the batteries

    4. Put in the new batteries and screw lock back into place

    www.qilocks.com [email protected] +44 (0)20 8906 6881