gat net.lock 7000 electronic rfid locker lock · gat net.lock 7000 electronic rfid locker lock...

7
GAT NET.Lock 7000 Electronic RFID Locker Lock Application The GAT NET.Lock 7000 is the ideal solution for the convenient electronic locking of lockers in leisure facilities, universities, companies and depots. System users are identified by the lock via contactless RFID data carriers (Radio Frequency Identification) and NFC technology. The GAT NET.Lock 7000 is suitable for a variety of locker types (wood, HPL, solid plastic, glass, and also steel sheet) and can be used with both left and right-hinged doors. A range of operating modes provide flexibility and allow the locks to be configured to suit specific system requirements. Functional description The GAT NET.Lock 7000 electronic locks connect to the GAT NET.Controller S 7000 slave controllers (up to 24 locks per slave controller). In order to use a locker, the user presses the locker door shut and holds their data carrier next to the RFID reading center on the locker door. The locking and usage status of the lock is indicated by an integrated LED. Highlights Up to 24 GAT NET.Lock 7000 per GAT NET.Controller S 7000 Up to 12 GAT NET.Lock 7000 per GAT NET.Controller S 7000 Light • Different operating modes available Reliable data transmission between RFID reader and data carrier Suitable for left and right-hinged doors and all types of locker material • Automatic calibration of the RFID antenna • LED status indicator (multi-colour) • Motor driven locking/unlocking ensures exceptional reliability Different bolt sets available with integrated RFID booster • Simple and secure bolt set installation Label carrier for metallic doors (customized label designs possible) Description Part No. GAT NET.Lock 7000 Electronic RFID locker lock 368534 1 www.gantner.com Order information Accessories Accessories Valid from May 3 rd , 2017 • Technical data subject to modification without notice. DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226 GAT NET.Lock 7000 GAT NET.Lock BoltSet 7100 Description Part No. GAT NET.Lock Basic Set F GAT NET.Lock Basic Set ISO The sets include master cards 369232 369333 GAT NET.Lock Tool 7000 Centre punch gauge for bolt mounting 533831 Description Part No. GAT NET.Lock BoltSet 7100 Door shackle carrier and booster for non-metallic doors 369535 GAT NET.Lock BoltSet 7200 Door shackle carrier and booster for metallic doors 532123 GAT NET.Lock BoltSet 7300 Door shackle carrier and booster for glass doors 774232 GAT NET.Controller M 7000 GAT NET.Controller M 7000 Light Master controller for the GAT NET.Controller S 7000 slave controller. The GAT NET.Controller M 7000 Light can control max. 3 slave controllers. 253224 978541 GAT NET.Controller S 7000 F/ISO GAT NET.Controller S 7000 F/ISO Light GAT NET.Controller S 7000 ICLS Slave controller for the GAT NET.Lock 7000 to suit different RFID technologies: F/ISO: MIFARE ® /ISO 15693, ICLS: iCLASS ® . GAT NET. Controller S 7000 F/ISO Light for up to 12 GAT NET.Lock 7000 locks. 253426 429730 768538 GAT NET.Lock Cable 5m Connection cable for the GAT NET.Lock 7000, 5 m length, 4-pin plug on both ends 734430 GAT NET.Lock Cable Extension 3m Extension cable for the GAT NET.Lock 7000, 3 m length 810021 GAT NET.Lock Label GEA rechts GAT NET.Lock Label GEA NUM rechts Self-adhesive door label in GANTNER design, for right- hinged doors, with or without locker number 679034 679236 GAT NET.Lock Label GEA links GAT NET.Lock Label GEA NUM links Self-adhesive door label in GANTNER design, for left- hinged doors, with or without locker number 370022 679135

Upload: others

Post on 29-Dec-2019

12 views

Category:

Documents


0 download

TRANSCRIPT

  • GAT NET.Lock 7000Electronic RFID Locker Lock

    ApplicationThe GAT NET.Lock 7000 is the ideal solution for the convenient electronic

    locking of lockers in leisure facilities, universities, companies and depots.

    System users are identified by the lock via contactless RFID data carriers

    (Radio Frequency Identification) and NFC technology.

    The GAT NET.Lock 7000 is suitable for a variety of locker types (wood,

    HPL, solid plastic, glass, and also steel sheet) and can be used with both

    left and right-hinged doors. A range of operating modes provide flexibility

    and allow the locks to be configured to suit specific system requirements.

    Functional descriptionThe GAT NET.Lock 7000 electronic locks connect to the GAT NET.Controller

    S 7000 slave controllers (up to 24 locks per slave controller).

    In order to use a locker, the user presses the locker door shut and holds

    their data carrier next to the RFID reading center on the locker door. The

    locking and usage status of the lock is indicated by an integrated LED.

    Highlights• Up to 24 GAT NET.Lock 7000 per GAT NET.Controller S 7000

    • Up to 12 GAT NET.Lock 7000 per GAT NET.Controller S 7000 Light

    • Different operating modes available

    • Reliable data transmission between RFID reader and data carrier

    • Suitable for left and right-hinged doors and all types of locker material

    • Automatic calibration of the RFID antenna

    • LED status indicator (multi-colour)

    • Motor driven locking/unlocking ensures exceptional reliability

    • Different bolt sets available with integrated RFID booster

    • Simple and secure bolt set installation

    • Label carrier for metallic doors (customized label designs possible)

    Description Part No.

    GAT NET.Lock 7000Electronic RFID locker lock

    368534

    1www.gantner.com

    Order information

    Accessories

    Accessories

    Valid from May 3rd, 2017 • Technical data subject to modification without notice. DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    GAT NET.Lock 7000

    GAT

    NE

    T.Lo

    ck B

    olt

    Set

    71

    00

    Description Part No.

    GAT NET.Lock Basic Set FGAT NET.Lock Basic Set ISOThe sets include master cards

    369232

    369333

    GAT NET.Lock Tool 7000Centre punch gauge for bolt mounting

    533831

    Description Part No.

    GAT NET.Lock BoltSet 7100Door shackle carrier and booster for non-metallic doors

    369535

    GAT NET.Lock BoltSet 7200Door shackle carrier and booster for metallic doors

    532123

    GAT NET.Lock BoltSet 7300Door shackle carrier and booster for glass doors

    774232

    GAT NET.Controller M 7000 GAT NET.Controller M 7000 LightMaster controller for the GAT NET.Controller S 7000 slave

    controller. The GAT NET.Controller M 7000 Light can

    control max. 3 slave controllers.

    253224

    978541

    GAT NET.Controller S 7000 F/ISOGAT NET.Controller S 7000 F/ISO LightGAT NET.Controller S 7000 ICLSSlave controller for the GAT NET.Lock 7000 to suit different

    RFID technologies:

    F/ISO: MIFARE®/ISO 15693, ICLS: iCLASS®. GAT NET.

    Controller S 7000 F/ISO Light for up to 12 GAT NET.Lock

    7000 locks.

    253426

    429730

    768538

    GAT NET.Lock Cable 5mConnection cable for the GAT NET.Lock 7000, 5 m length,

    4-pin plug on both ends

    734430

    GAT NET.Lock Cable Extension 3m Extension cable for the GAT NET.Lock 7000, 3 m length

    810021

    GAT NET.Lock Label GEA rechtsGAT NET.Lock Label GEA NUM rechtsSelf-adhesive door label in GANTNER design, for right-

    hinged doors, with or without locker number

    679034

    679236

    GAT NET.Lock Label GEA linksGAT NET.Lock Label GEA NUM linksSelf-adhesive door label in GANTNER design, for left-

    hinged doors, with or without locker number

    370022

    679135

  • Nominal voltage UDC: 5 V

    Power supply: Via connection cable from the slave controller

    Aver. power consumption: 60 mW

    Reader types: GAT NET.Controller S 7000 - F/ISO: - ICLS:

    MIFARE® + ISO 15693iCLASS®

    Retaining force: Min. 1,500 N (337.2 lb)

    Max. locks per slave controller: 24 (GAT NET.Controller S 7000)12 (GAT NET.Controller S 7000 Light)

    User guidance: Multi-colored status LED

    Connectors: MOLEX, type Micro-Fit 3.0TM

    Interface: One-Wire (special cable for power supply, data and RF signal)

    Housing material: Plastic (PC)

    Door width: min. 230 mm (9.05´´)

    Dimensions: 110 mm x 100 mm x 25 mm(4.33´´ x 3.94´´ x 0.98´´)

    Permitted ambient temperature: 0 °C to 60 °C (32 °F to 140 °F)

    Protection type: IP 52

    Protection class: III

    Weight: Approx. 160 g (5.6 oz)

    Environment classbased on VdS 2110: II (conditions in indoor areas)

    Compliance: CE, FCC, IC

    2 www.gantner.com

    Technical data

    Dimensions

    Valid from May 3rd, 2017 • Technical data subject to modification without notice. DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    OUT

    To server/host Ethernet

    RS 485 SLAVES

    GAT NET.Power Plug

    RS-485 + Power

    Lockers

    Power

    GAT NET.Lock 7000

    RFID data carrier

    RS-485

    INOUTIN

    Power

    RS 485 SLAVES

    OUT

    RS-485 + Power

    Power

    Power

    IN

    = GAT NET.Controller M 7000(Master controller)

    = GAT NET.Controller S 7000(Slave controller)

    Typical application

    1. GAT NET.Lock 7000

    2. Door shackle

    3. Door contact

    4. Hole for status LED

    5. Metal support (for glass doors)

    6. Label carrier

    1

    1

    Top View

    Side View

    78 (3.07)

    10

    4 (

    4.1

    )

    62.3 (2.45)

    4

    6

    5.8 (0.23)

    10 (0.39)

    8 (0.31)

    5

    8 (0.31)3 (0.12)

    4 4

    5

    40.3 (1.58)31.3 (1.23)

    5

    3

    88

    .1 (

    3.4

    7)

    88

    .1 (

    3.4

    7)

    4 4

    2

    2

    2

    2

    3 3

    2

    2

    4

    Top ViewTop ViewTop View

    Side View Side View Side ViewFront View Front View Front View Front View Label Carrier

    89

    .1 (

    3.5

    1)

    25 (0.98)

    10

    0 (

    3.9

    4)

    50

    (1

    .97

    ) 94

    (3

    .7)

    6 (

    0.2

    4)

    91 (3.58)

    17 (0.67)

    110 (4.33)

    GAT NET.Lock 7000 GAT NET.Lock BoltSet 7100 GAT NET.Lock BoltSet 7300 GAT NET.Lock BoltSet 7200

    Dimensions in mm (inches in brackets)

  • 3www.gantner.comValid from May 3rd, 2017 • Technical data subject to modification without notice.

    DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    Installation instructionsThe GAT NET.Lock 7000 (1) is mounted to the inside of the locker wall

    using 3 screws (3). The bolt set (2) including door shackle is attached to

    the inner side of the locker door. For non-metallic doors, only a drill hole

    through the locker door is required for the status LED. For metallic doors,

    a cut-out must be made in the locker door to accommodate the bolt set

    and label carrier. For glass doors, the bolt set is combined with a metal

    support and attached to the locker door using adhesive.

    NOTE! The GAT NET.Lock 7000 needs min. 10 mm clearance from the

    bottom or top of the locker to allow the hole marking gauge to be used

    for installation. A detailled description of the hole marking gauge can be

    found in the GAT NET.Lock 7000 manual.

    Door status contact

    The GAT NET.Lock 7000 has a contact that is activated or deactivated

    by the door contact (5) on the bolt set when the locker door is closed or

    opened respectively. This function determines the open/close state of the

    door. It is important that this contact remains clean and undamaged to

    ensure the correct functionality of the GAT NET.Lock 7000.

    Installation in lockers with non-metallic doors

    Installation requirements

    Please pay particular attention to the following points:

    - When the locker door is pressed shut, ensure there is no gap between

    the bolt set (2) and the front of the GAT NET.Lock 7000. Ideally the bolt

    set should touch the front of the lock.

    - The front side of the bolt set and the GAT NET.Lock 7000 must be

    aligned parallel to each other.

    Installation procedure

    Before installing all locks in a new locker system, a test installation of at

    least one lock and a final function check must be performed. Only once

    the functional testing is successfully completed may the remaining locks

    be installed in the same way.

    1. Drill three holes (3) for the GAT NET.Lock 7000 into the locker wall.

    2. Plug-in the connection cable and loop cable (for reserve) in the

    underside of the housing (see “Electrical connections” on page 7).

    Door width

    The minimum allowed door width (measured from the door shackle to the

    hinge) is 230 mm (9.05´´). If the door is narrower than this measurement,

    the door shackle will hit the locker when the door is being closed.

    1. GAT NET.Lock 7000

    2. GAT NET.Lock Bolt Set 7100

    3. Mounting screws for GAT NET.Lock 7000

    5. Door contact

    6. Mounting screws for bolt set

    7. LED (hole in locker door)

    Dimensions in mm (inches in brackets)

    3 1

    5

    3

    3

    6

    6

    74 (2.91)17 (0.67)

    17

    .5

    (0.6

    9)

    24

    3.6

    (1

    .72

    )3

    1.4

    (1

    .24

    )

    1 6

    6

    77

    15 (0.59)

    3

    3

    Lock

    er w

    all

    Lock

    er d

    oor

    3

    2

    8 (0.31)

    15.1 (0.59)

    17.6 (0.69)

    50

    (1

    .97

    )

    6 (

    0.2

    4)

    94

    (3

    .7)

    3. Mount the GAT NET.Lock 7000 with three screws (3) on the inside

    locker wall.

    NOTE! Use the correct screws according to the type of locker

    material, max. Ø 4 mm (0.16´´). The maximum allowed tightening

    torque of the screws is 2 Nm (1.47 lb-ft).

    4. Drill three mounting holes (6) for the GAT NET.Lock Bolt Set 7100.

    5. Drill a hole for the status LED in the locker door (7). The recommended

    diameter is 10 mm (0.39´´).

    6. Attach the bolt set to the locker door using three screws.

    NOTE! Use the correct screws according to the type of locker

    material, max. Ø 4 mm (0.16´´). The maximum allowed tightening

    torque of the screws is 2 Nm (1.47 lb-ft).

    7. A label (GANTNER standard design or custom design) can be

    attached to the locker front. If a custom label design is used, ensure

    that a transparent field for the LED light is included in the label design.

    8. Test the locker door to confirm that it can close easily and the door

    shackle inserts correctly into the GAT NET.Lock 7000.

    9. The locker door must spring open after unlocking.

    NOTE! Also observe the instructions in the GAT NET.Lock 7000 manual.

  • 4 www.gantner.comValid from May 3rd, 2017 • Technical data subject to modification without notice. DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    Installation in lockers with metallic doors

    Cutouts in the locker door

    Cutouts must be made in the inside and outside walls of the locker door

    in order to mount the GAT NET.Lock Bolt Set 7200 and label carrier. The

    installation procedure is described on the next page. The measurements

    for the cutouts are shown in the diagram below.

    3

    2

    2

    6

    7

    1

    6

    9

    6

    6

    10

    7

    12311

    7

    3

    5

    1

    Lock

    er w

    all

    50

    (1

    .97

    )

    6 (

    0.2

    4)

    94

    (3

    .7)

    Lock

    er d

    oor

    (out

    side

    wal

    l)

    Lock

    er d

    oor

    (insi

    de w

    all)

    74 (2.91)17 (0.67)

    min

    . 18

    (0.7

    1)m

    ax. 2

    6 (1

    .02)

    5.8 (0.23)2 (0.08)

    Inside of locker

    15.1(0.59)

    32

    .6 (

    1.2

    8)

    Lock

    er w

    all

    Lock

    er w

    all

    3

    3

    17.

    5 (

    0.6

    9)

    Locker door(front view without label carrier)

    Locker door(front view with label carrier)

    Locker door(front view with label carrier + label)

    33

    9

    LED

    67.6 (2.66)

    32.1 (1.26)

    29

    .5 (

    1.1

    6)

    64

    .5 (

    2.5

    4)

    8

    6

    63.4 (2.5)

    29 (1.14)

    40

    .2 (

    1.5

    8)

    28

    (1

    .1)

    32.5

    (1.2

    8)4

    4.5

    (1

    .75

    )

    Lcok

    er d

    oor

    (out

    side

    wal

    l)

    Lcok

    er d

    oor

    (insi

    de w

    all)

    Lock

    er w

    all Locker door (outer wall)

    Cutout area marked in grayLocker door (inner wall)

    Cutout area marked in grayInside of locker

    9

    89

    6

    4 x screw holes,Ø 3.6 (0.14)

    1. GAT NET.Lock 7000

    2. GAT NET.Lock Bolt Set 7200

    3. Mounting screws for GAT NET.Lock 7000

    5. Door contact

    6. Mounting screws for bolt set

    7. LED position

    8. Cutout for GAT NET.Lock BoltSet 7200

    9. Cutout for label carrier

    10. Label carrier

    Dimensions in mm (inches in brackets)

    Dimensions in mm (inches in brackets)

  • 5www.gantner.comValid from May 3rd, 2017 • Technical data subject to modification without notice.

    DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    9. Attach the front label (11) onto the label carrier.

    NOTE! The front label can be ordered with a standard GANTNER

    or customized design. For customized labels, ensure that a transparent

    field for the status LED (7) is included in the label design.

    10. Test the locker door to confirm that it can close easily and the door

    shackle inserts correctly into the GAT NET.Lock 7000.

    NOTE! Also observe the instructions in the GAT NET.Lock 7000 manual.

    3

    2

    2

    6

    7

    1

    6

    9

    6

    6

    10

    7

    12311

    7

    3

    5

    1

    Lock

    er w

    all

    50

    (1

    .97

    )

    6 (

    0.2

    4)

    94

    (3

    .7)

    Lock

    er d

    oor

    (out

    side

    wal

    l)

    Lock

    er d

    oor

    (insi

    de w

    all)

    74 (2.91)17 (0.67)

    min

    . 18

    (0.7

    1)m

    ax. 2

    6 (1

    .02)

    5.8 (0.23)2 (0.08)

    Inside of locker

    15.1(0.59)

    32

    .6 (

    1.2

    8)

    Lock

    er w

    all

    Lock

    er w

    all

    3

    3

    17.

    5 (

    0.6

    9)

    Locker door(front view without label carrier)

    Locker door(front view with label carrier)

    Locker door(front view with label carrier + label)

    33

    Installation requirements

    Please pay particular attention to the following points:

    - The thickness of the locker door must be between 18 mm and 26 mm

    (0.71´´ and 1.02´´).

    - When the locker door is pressed shut, ensure there is no gap between

    the bolt set (2) and the front of the GAT NET.Lock 7000. Ideally the bolt

    set should touch the front of the lock.

    - The front side of the bolt set and the GAT NET.Lock 7000 must be

    aligned parallel to each other.

    Installation procedure

    Before installing all locks in a new locker system, a test installation of at

    least one lock and a final function check must be performed. Only once

    the functional testing is successfully completed may the remaining locks

    be installed in the same way.

    1. Drill 3 holes (3) for the GAT NET.Lock 7000 into the locker wall.

    2. Plug the connection cable in and loop cable (for reserve) in the

    underside of the housing (see “Electrical connections” on page 7).

    3. Mount the GAT NET.Lock 7000 with 3 screws (3) onto the inside

    locker wall.

    NOTE! Use the correct screws according to the type of locker

    material, max. Ø 4 mm (0.16´´). The maximum allowed tightening

    torque of the screws is 2 Nm (1.47 lb-ft).

    4. Cut out a section (8), 63.4 mm x 68.2 mm (2.5´´ x 2.69´´), in the inner

    wall of the locker door for the GAT NET.Lock Bolt Set 7200.

    5. Drill 4 holes (6) in the inner wall of the locker door for mounting the

    GAT NET.Lock Bolt Set 7200.

    6. Cut out a section (9), 67.6 mm x 94 mm (2.66´´ x 3.7´´), in the outer

    wall of the locker door for the label carrier.

    7. Mount the bolt set onto the inside wall of the locker door using 4

    screws.

    NOTE! Use pan-head metal screws, Ø 3.5 mm (0.14´´), screw length

    depends on locker door thickness. The maximum tightening torque of

    the screws is 2 Nm (1.47 lb-ft).

    8. Push the label carrier onto the outside wall of the locker door. The

    label carrier will hold in place with the lashes on the label carrier. To

    protect against manipulation, a screw can be used to fix the bolt set to

    the label carrier.

    NOTE! Use a countersunk metal screw, Ø 2.9 mm (0.11´´). Screw

    length depends on locker door thickness, e.g., a 15 mm (0.59´´) thick

    door requires a 19 mm (0.75´´) long screw.

  • 6 www.gantner.comValid from May 3rd, 2017 • Technical data subject to modification without notice. DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    Installation in lockers with glass doors

    3

    3

    3

    11

    7 5

    3

    Lock

    er d

    oor

    (gla

    ss)

    74 (2.91)17 (0.67)

    49

    .5 (

    1.9

    4)

    38

    .6 (

    1.5

    2)

    212

    12

    7

    2

    17

    .5(0

    .69

    )

    Lock

    er w

    all

    3 3

    11 (0.43)

    50

    (1

    .97

    )

    6 (

    0.2

    4)

    94

    (3

    .7)

    15.1 (0.59)

    17.6 (0.69)

    Installation procedure

    Before installing all locks in a new locker system, a test installation of at

    least one lock and a final function check must be performed. Only once

    the functional testing is successfully completed may the remaining locks

    be installed in the same way.

    1. Drill 3 holes (3) for the GAT NET.Lock 7000 into the locker wall.

    2. Plug-in the connection cable and loop cable (for reserve) in the

    underside of the housing (see “Electrical connections” on page 7).

    3. Mount the GAT NET.Lock 7000 with 3 screws (3) on the inside locker

    wall.

    NOTE! Use the correct screws according to the type of locker

    material, max. Ø 4 mm (0.16´´). The maximum allowed tightening

    torque of the screws is 2 Nm (1.47 lb-ft).

    4. Use glass adhesive to attach the GAT NET.Lock BoltSet 7300 in the

    correct position to the inside of the locker door. Ensure the bolt set

    and metal support are screwed together before applying adhesive.

    NOTE! Before installation, test to ensure that the adhesive meets

    the strength requirements. Always follow the adhesive manufacturer’s

    instructions.

    5. A label (GANTNER standard design or custom design) can be

    attached to the locker front. If a custom label design is used, ensure

    that a transparent field for the LED light is included in the label design.

    6. Test the locker door to confirm that it can close easily and the door

    shackle inserts correctly into the GAT NET.Lock 7000.

    1. GAT NET.Lock 7000

    2. GAT NET.Lock Bolt Set 7300

    3. 3 x mounting screws for the GAT NET.

    Lock 7000

    5. Door contact

    7. LED position

    12. Metal support for glass door (included in

    the GAT NET.Lock BoltSet 7300)

    Dimensions in mm (inches in brackets)

    Installation requirements

    Please pay particular attention to the following points:

    - When the locker door is pressed shut, ensure there is no gap between

    the bolt set (2) and the front of the GAT NET.Lock 7000. Ideally the bolt

    set should touch the front of the lock.

    - The front side of the bolt set and the GAT NET.Lock 7000 must be

    aligned parallel to each other.

    NOTE! Also observe the instructions in the GAT NET.Lock 7000 manual.

  • Electrical connections

    Power supply and signal lines

    DC power supply (see technical data) required for the RFID reading field

    and to power locking actions.

    Antenna calibration

    The GAT NET.Lock 7000 automatically calibrates its integrated RFID

    antenna to optimise the reading field. A detailed description of this feature

    is available in the GAT NET.Lock 7000 manual.

    Configuration

    Configuration of the GAT NET.Lock 7000 and other associated components

    is completed using GAT Relaxx PC software. The configuration process is

    described in the GAT NET.Lock 7000 and the GAT Relaxx manuals.

    Connection cable

    To connect the GAT NET.Lock 7000 to a GAT NET.Controller S 7000, use

    the GAT NET.Lock Cable 5m with 4-pin MOLEX plug on both ends. Use

    a GAT NET.Lock Cable Extension 3m (Part No. 810021) to extend the

    cable length to 8 m.

    Alternatively, a 10 m cable can be made by connecting two GAT NET.Lock

    Cable 5 m cables together. Use a GAT NET.Lock Connector (Part No.

    442123) to connect the cables.

    NOTE! Only use original cables from GANTNER Electronic GmbH to

    connect the GAT NET.Lock 7000.

    Connection cable installation

    The connection cable can be installed either concealed in the locker body

    or left unconcealed. For concealed cabling, the cable exits the locker body

    via a hole beneath the lock (1 in diagram below).

    For unconcealed cabling, remove one of the outlets (circled in diagram

    below) in order to direct the cable neatly out of the GAT NET.Lock 7000

    housing.

    NOTE! Always leave sufficient reserve cable at the lock end (e.g., loop

    cable in the lock housing) for future service requirements.

    The WEEE symbol on GANTNER products and their packaging indicates that the corresponding material must not be disposed of with normal household waste. Instead such marked waste equipment must be disposed of by handing it over to a designated electronic waste recycling facility. Separating and recycling this waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. Please contact your local authority for further details of your nearest electronic waste recycling facility.

    7www.gantner.comValid from May 3rd, 2017 • Technical data subject to modification without notice.

    DB_GAT-NET-Lock7000--US_26.indd • Part No.: 930226

    Safety Instructions- The installation and maintenance of this device must be

    performed by trained, qualified personnel.- All applicable safety and accident prevention regulations

    must be observed.- Safety devices must not be removed.- Please observe the technical data of the device specified in

    this datasheet.- The device must be disconnected from the power supply

    prior to installation, assembly or dismantling.

    1

    1