revenue accuracy in an advanced power quality analysis meter

29
Revenue accuracy in an advanced power quality analysis meter PowerLogic ION7550/ION7650

Upload: hasad-grimes

Post on 31-Dec-2015

41 views

Category:

Documents


0 download

DESCRIPTION

Revenue accuracy in an advanced power quality analysis meter. PowerLogic ™ ION7550/ION7650. ION7550/ION7650 meters are part of a complete PowerStruxure solution. Integrate with StruxureWare Power Monitoring software Help engineering and management personnel meet operational goals: - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Revenue accuracy in an advanced power quality analysis meter

Revenue accuracy in an advanced power quality analysis meter

PowerLogic™ ION7550/ION7650

Page 2: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 2- Division - Name – Date

ION7550/ION7650 meters are part of a complete PowerStruxure solution

● Integrate with StruxureWare Power Monitoring software

● Help engineering and management personnel meet operational goals:

● Improve efficiency and cut energy-related costs

● Assure reliability and reduce downtime● Optimize equipment utilization and reduce

the cost of operations

More on PowerStruxure at the end of the presentation….

Page 3: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 3- Division - Name – Date

ION7550/ION7650 meters help enable PowerStruxure solutions with…

● Unmatched functionality

● Advanced power quality analysis

● Revenue accuracy

● Multiple communications options

● Web compatibility

● Control capabilities

● Trending and forecasting

● Disturbance direction detection

● Choice of display options

● Integral, high-visibility backlit LCD with adjustable contrast

● Separately-mounted, color touch screen backlit LCD with wide viewing angle

Integrate with your existing wholesale settlement system, use StruxureWare Power Monitoring software, or share operations data with existing SCADA systems

Customize metering or analysis functions without any hard-wiring

Page 4: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 4- Division - Name – Date

Revenue metering accuracy in a Class A power quality meter!

● Meets IEC and ANSI accuracy measurement standards

● IEC 62053-22 Class 0.2S

● ANSI C12.20 0.2, Class 10 & 20

● Measures according to IEC 61000-4-30 Class A Edition 2 (power quality parameters)

● Measures flicker (IEC 61000-4-15)

● Monitors power quality compliance (EN50160 – ION7650 only)

● Multi-user, multi-level security provides read-access rights to administrative rights for up to 16 designated users

Page 5: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 5- Division - Name – Date

Choice of high-visibility display options

● The ION7550/ION7650 meter’s intuitive, integral display features a high visibility 87 x 112 mm backlit LCD with adjustable contrast

● The 86 x 115 mm color, remote-mounted LCD is touch screen operated and communicates to the meter via serial or Ethernet

● Languages include English, French, and Spanish; User-configurable IEC or IEEE notations; 12/24 hour clock support in multiple date/time formats.

Page 6: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 6- Division - Name – Date

Gateway functionality

● Can act as a gateway when the Ethernet port and/or modem options are present

● Modbus Master allows front panel display of real-time parameters from any downstream Modbus devices.

EtherGate ModemGate

Ethernet Telephone lineSerialSerial

● EtherGate: access via Ethernet port and ModbusTCP to daisy-chained Modbus devices connected to the meter’s serial ports

● ModemGate: access from telephone network to devices connected to the meter’s serial ports

Page 7: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 7- Division - Name – Date

Modular, flexible ION architecture

● Use StruxureWare Power Monitoring software to leverage the meters modular, flexible ION architecture for extensive customization

● Uses simple “building block” approach

● Uniquely addresses advanced monitoring and control applications

● Adapts to changing needs, avoiding obsolescence

Page 8: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 8- Division - Name – Date

Front panel features

Softkeys

ANSI opticalport

Operational LEDs

Navigation buttons

PROG/SELECT buttons

High visibility display screen

Page 9: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 9- Division - Name – Date

Rear connection features

Voltage/Current Inputs

Digital Inputs

Analog Inputs

Analog Outputs

Power Supply

Ground Terminal

Form C Digital Outputs Digital Inputs

Form A Digital Outputs

Page 10: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 10- Division - Name – Date

Communications features

Fiber (100BASE-FX)Modem (if equipped)

Ethernet 10BASE-T/100BASE-TX

RS-485

RS-232

ANSI type 2optical port(front panel)

Page 11: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 11- Division - Name – Date

List of features

Feature ION7550 ION7650

Metering

Power, energy, & demand ■ ■

Power Quality

Sag/swell, harmonics monitoring ■ ■

Harmonics: individual, even, odd, up to 63rd 63rd

Harmonics: magnitude, phase, and inter-harmonics 50th

Symmetrical components: zero, positive, negative ■ ■

Transient detection, microseconds (20 µs for 50 Hz, 17 µs for 60 Hz) 17/20

Sampling rate, maximum samples per cycle 256 1024

IEC61000-4-15 flicker ■

EN50160 compliance checking ■

Recording compliant with IEC 61000-4-30 Class A Edition 2 ■

Disturbance direction detection ■ ■

Logging and Recording

Memory standard/optional 5MB/10MB 5MB/10MB

Min/max, historical, waveform logging ■ ■

Timestamp resolution in seconds 0.001 0.001

Historical trend information via front panel display ■ ■

GPS time synchronization ■ ■

Page 12: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 12- Division - Name – Date

List of features

Feature ION7550 ION7650

Communications and I/O

RS-232/485; RS-485; Ethernet; Optical ■ ■

Internal modem 1 1

3-port DNP 3.0 via serial, modem, Ethernet, I/R ports ■ ■

Modbus RTU slave/master; Modbus TCP ■ ■

IEC 61850 protocol support ■ ■

EtherGate, ModemGate, MeterM@il, WebMeter ■ ■

Analog inputs/outputs (optional) 4/4 4/4

Digital status inputs/outputs 16/4 16/4

Relay outputs (standard) 3 3

Setpoints, alarming and control

Setpoints, number/minimum response time 65/ ½ cycle 65/ ½ cycle

Math, logic, trig, log, linearisation formulas ■ ■

Call-out on single & multi-condition alarms ■ ■

Page 13: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 13- Division - Name – Date

METERING APPLICATIONS

Validate power quality with the energy contract

Verify reliable equipment operation

Improve response to power quality-related issues

Allocate energy costs to departments or processes

Reduce peak demand surcharges, power factor penalties

Participate in load curtailment programs

Identify billing discrepancies

Augment energy rate negotiations

Enhance substation automation

Leverage existing infrastructure

Integrate with other utility metering systems

Page 14: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 14- Division - Name – Date

Validate power quality

● Analyse power quality, including harmonics, disturbances

● Sag/swell monitoring: report on disturbance magnitude and duration

● Analyse disturbances to determine direction relative to meter

● Power quality results comply with EN50160 standard (ION7650 option)

● Certified to IEC61000-4-30 Class A Edition 2 (ION7650)

● Compare monthly results with energy contract to determine compliance

Page 15: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 15- Division - Name – Date

Verify reliable equipment operation

● Optimize configuration of power distribution equipment

● Compare load characteristics to confirm correct connections, proper operation

● Audit real-time and historical data

● Reveal relationships between equipment and other system factors

● Evaluate, document risks

Page 16: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 16- Division - Name – Date

Improve response to power quality-related issues

● Collect data from key points across substations or facilities

● Display power quality-related conditions, alert personnel to issues

● Track disturbances, isolate problem sources

● Confirm the proper operation of equipment such as transient voltage surge suppressors

● Eliminate manual labor involved in tracking UPS capacities and operations

Page 17: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 17- Division - Name – Date

Allocate energy costs to departments or processes

● Track energy costs to cost centers, identify demand control opportunities, check energy consumption patterns, verify bills

● Track system-wide power factor, demand peaks, penalty tariff structures

● Revenue-class certified

● MV-90 support and multi-year scheduling with hourly activity profiles

Page 18: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 18- Division - Name – Date

Reduce peak demand surcharges, power factor penalties

● Avoid penalties with automated:

● Load shedding Peak shaving

● Scheduling Capacitor bank control

● Measure block, rolling block and predicted demand

● Measure on any instantaneous value; records peak and minimum

Page 19: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 19- Division - Name – Date

Participate in load curtailment programs

● Evaluate feasibility of program participation: deliver load profiles, forecast and analyse costs

● Determine where, quantity of load reduction in response to curtailment requests

● Automatically shed loads, start up generators to coordinate curtailment strategies

Page 20: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 20- Division - Name – Date

Identify billing discrepancies

● Use collected energy data to compare and reconcile with supplier energy data

● Validate compliance with energy contract terms

● Identify and reconcile penalty charges (i.e. large peak demand surcharge for increased power draws)

● Capture all event information to validate charges

Page 21: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 21- Division - Name – Date

Augment energy rate negotiations

● Make informed procurement decisions, manage multiple supply agreements

● Collect detailed energy consumption data, energy-relevant information

● Study historical load profile data, forecast energy needs, analyze alternate utility rate structures

● Perform “what-if” analyses to identify the most favorable tariffs

Page 22: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 22- Division - Name – Date

Enhance substation automation

● Improve process yields and extend equipment life

● Analog and digital I/O enables systems monitoring and control

● Set alarms to warn of pending problems

● Base maintenance schedules on operating history

● Log events and alarms for all critical conditions

● IEC 61850 protocol support to ease integration with SCADA

Page 23: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 23- Division - Name – Date

Leverage existing infrastructure

● Assess overall efficiency, reliability of electrical system

● Determine capacity of electric network, run at peak efficiency

● Displays, trends, and continuously updates historical data - up to four parameters simultaneously

● Integrates with on-site generation; use to implement load shedding

Page 24: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 24- Division - Name – Date

Integrate with other utility metering systems

● Collect, scale, and log water, air, gas, electricity, and steam readings from connected meters or transducers

● Deliver this information to head-end systems

Page 25: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 25- Division - Name – Date

POWERSTRUXURE SOLUTIONSMaximize the efficiency and reliability of your power network

Page 26: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 26- Division - Name – Date

PowerStruxure solutions deliver real-time, relevant, and actionable information precisely when and where you need it

Page 27: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 27- Division - Name – Date

PowerStruxure exceeds traditional power management

● PowerStruxure is an extensive, advanced family of electrical distribution solutions that combine:

● Power monitoring and control software

● Systems designed to help you stay on top of real-time conditions, isolate problems, study trends, control loads and generators

● Communication devices and protocols

●At the heart of our PowerStruxure solution, they link the software with your power network hardware

● World-class hardware

●A wide, deep range of products that includes intelligent metering devices, switchgear, circuit breakers, protection relays, power factor correction equipment

Page 28: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 28- Division - Name – Date

A PowerStruxure solution can help you...

● Lower operations costs

● Automated, accurate billing data acquisition lowers administrative costs and eliminates errors while making the data available to regulators, service providers, and end users.

● Improve network reliability

● Sophisticated power quality monitoring and reporting provide the information needed to validate compliance, improve system stability, and minimize unplanned downtime.

● Streamline business planning

● Detailed information on loading, capacity, stress, and more, remove the guesswork so you can more efficiently coordinate demand-side management programs and optimize capacity planning.

Page 29: Revenue accuracy in an advanced power quality analysis meter

Schneider Electric 29- Division - Name – Date

Visit us on the web for more information

www.schneider-electric.com