Advanced Heating & Hot Water Systems
Makes Installation with Most Boilers Easy *
QUICK ZONE MANIFOLD
SYSTEM
Save Time and Money
Reduce Installation
Times By 50-75%
Work Smarter Not Harder
w w w . h t p r o d u c t s . c o m
* UFT Boiler sold separately
A Closer Look!
ExpansionTank
OptionalPrimary– SecondaryLoop Fitting
3 SpeedCirculator
3 SpeedCirculator
3 SpeedCirculator
3 SpeedCirculator
Relay
Air Eliminator Auto Fill Back Flow Preventer
Temperature Pressure Gauge
Temperature Pressure Gauge
Drain
QUICK ZONE MANIFOLD SYSTEM
Streamline Everything from Bidding to Start-Up Work smarter, not harder with HTP’s Quick Zone Manifold System. It helps contractors and distributors save time and money! Speed up every step of the hydronic process, from bidding to start-up with the help of these prefabricated panels.
Fixed Costs Help Make Bidding Fast and Simple
Cut Installation Times By 50-75% Eliminate the time consuming labor of starting from scratch, with the Quick Zone Manifold System. Simply hang the panel and connect the boiler and zones. Before you know it, you are done!.
Versatile System This zero to four zone panel may be used in conjunc-tion with any direct flow boilers, including HTP’s highly efficient Pioneer and UFT. The manifold system may also be used with radiators, baseboards, and radiant heating systems.
Professional Panel Present a professional appearance every time!
Works with Most Hydronic Boilers
QUICK ZONE MANIFOLD SYSTEM
UFT Boiler*
* Special Packages Available With The UFT And The Quick Zone Manifold System Grouped Together
w w w . h t p r o d u c t s . c o m • H T P, N e w B e d f o r d , M AIn accordance with our company policy of ongoing product improvement, HTP Inc. reserves the right to make changes without prior notice. • © HTP • MRKT-90 • 11/2016
Radiant Flooring with
The Quick Zone Manifold
System
8 “8 “
8 “
3 “
5 “
* Replace the * in the Model number with a P, E or Z (This will determine which pumps or zone valves are used in the QZMS model):
P = PumpE = ECM PumpZ = Zone Valves
The dimensions may vary based on the number of zones and pumps selected, as well as the size of the pipes and expansion tanks. Model QZMP140-4 is shown on right.
Boiler Zone Feed
LoopTemperature
Sensor
Circulator
RadiantZone
I Series Valve
Boiler Zone Return
Isolated Radiant Loop
Models Zones / Pumps Max Btuh Pipe Size Expansion Tank Priority DHWQZM*140-2 2
up to140,000 1” #30
NoQZM*140-3 3 YesQZM*140-4 4 YesQZM*220-2 2
up to220,000 1 1/4” #60
NoQZM*220-3 3 YesQZM*220-4 4 Yes
46.5”
46.5”8 “