pureit excella u-manual philippines phii-v04
TRANSCRIPT
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
1/28
Welcome to the Pureit Family
Complete Germ Protection
REACH PUREIT AT
www.pureitwater.com
+632-5620091
+632-9498071
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
2/28
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
3/28
1
Congratulations!
Welcome to the Pureit Family! We thank you for the trust you have shown in ourproduct and we guarantee you that our product will live up to your expectations.
Pureit Excella is trusted by millions of users around the world for providing safedrinking water for their loved ones.
Our product is developed by experts and is designed to give you water that is
completely protected from harmful germs. Pureit adheres to the toughest globalstandards of some leading institutions.
If ever you need to get in touch with us for anything, please call us at
+632-5620091, +632-9498071.
We once again thank you for buying our product and we look forward to a longand fruitful association with you.
Complete Germ Protection
Worlds largest selling water purifiers*
* Based on Unit shipment sales for 2012. Excludes pitchers and faucet mount system sales and includes only in-home point-of-use drinking watertreatment systems.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
4/28
2
CONTENTS
Pureit Excella Advantages ........................................................................3
Getting to Know Your Pureit Excella.......................................................4
How Pureit Excella Works......................................................................5
Setting up Pureit Excella.........................................................................6
Ordering and Changing the Germkill Kit.................................................8
Cleaning & Maintenance of Pureit Excella..............................................16
Dos & Donts.........................................................................................23
FAQs .....................................................................................................24
Technical Specifications for Pureit Excella.............................................25
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
5/28
3
PUREIT EXCELLA ADVANTAGES
No continuous tap water
No harmful bacteria, virus & parasites
No chlorine taste
No boiling
No electricity
Food grade plastic
Auto Shut-off
No undesirable odour
Natural tasting water
Great after sales service
Advanced Alert System
Strong and durable
No expensive bottled water
Programmed Germkill Technology
Easy Maintainence
No plumbing
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
6/28
4
GETTING TO KNOW YOUR PUREIT EXCELLA
Germkill Life Indicator Cover
Sediment Filter
Top Lid
Top Cover
Top Chamber
Carbon Polisher
Microfiber Mesh
Tap
Microcharged Membrane Assembly
Transparent Chamber
Pedestal
Germkill Life Indicator
Cleansing Collection Chamber
Germkill Processor
Batching Chamber
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
7/28
5
HOW PUREIT EXCELLA WORKS
Removes
harmful parasites and
chlorine, making thewater clear, odorless
and natural tasting.
CarbonPolisher
Purifies
the water againand removes harmful
parasites giving the
assurance of double
protection.
Micr
ochar
gedMembrane
Uses
PGT - ProgrammedGermkill Technology
to target and remove
harmful viruses and
bacteria.
Germ
killProcessor
Removes
precipitatedmetallic
impurities.
MicrofiberMesh
Removes
visible dirt
Sedim
entFilte
r
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
8/28
6
SETTING UP PUREIT EXCELLA
Remove the Transparent Chamber with the
pedestal and keep it aside.
Discard the plastic film from it.
Remove the Cleansing Collection Chamber,
Top Chamber and the Top Lid and keep it aside.Discard the thermocol from the Top Chamber.
Wash hands thoroughly. Remove the
Microcharged Membrane Assembly fromtamper proof pouch kept inside the
Cleansing Collection Chamber.
Open the box. Remove the Top Cover and keep it
aside. Remove and discard the thermocol.
There is a bellow pump in the Top Chamber. Keep it in a safe place as you will
need it later for cleaning.
1
3
2
4
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
9/28
7
SETTING UP PUREIT EXCELLA
Place the Top Chamber on the Cleansing Collection
Chamber, then place Sediment Filter in the TopCover and place it on the Top Chamber.
Pour in water till the top of the Top Chamber and drain
out all the water that collects in the Transparent Chamberfor first two cycles. Place the lid on the Top Cover. Pureit
is now ready to use from third cycle onwards.
7 8
After fitting the Microcharged Membrane Assembly to the Cleansing Collection Chamber,do not rest the assembly on a flat surface.
Please note that the first cycle will not give full 9L of water in the Transparent Chamber
since some water gets stored in the Cleansing Collection Chamber and the Top Chamber.
Now place the Cleansing Collection Chamber
on the Transparent Chamber.
Insert the Microcharged Membrane Assembly at
the base of the Cleansing Collection Chamber.
Twist in clockwise direction to fit.
5 6
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
10/28
8
ORDERING AND CHANGING THE GERMKILL KIT
When Indicator shows white or partiallyred, the Germkill Kit is working and its safe
to use.
When Indicator shows mostly red, theGermkill Kit is nearing its end of life
and its time to buy a new Germkill Kit.
When Indicator shows fully red, the
Germkill Kit has exhausted and it is timeto replace it.
Safe to use
Time to buy anew Germkill Kit
Time to replace
There is an Auto Shut-off overflow port provided on the Germkill Life Indicator Cover.When the Germkill Life Indicator is red, you might observe overflow from this port. Pleasereplace the Germkill Kit. Do not pour any more water in the Top Chamber to avoid furtherspillage.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
11/28
9
There are multiple Pureit Germkill Kit(s) available. Please buy the one that is recommended
for your Pureit model.
ORDERING AND CHANGING THE GERMKILL KIT
Microcharged Membrane Germkill Processor Carbon Polisher
You can buy a Germkill Kit in any
of the following ways
The Germkill Kit consists of 3 parts
www.pureitwater.comLog on to locate your nearest dealerVisiting your nearest Pureit dealer
+632-5620091+632-9498071Call Pureit helpline to
locate your nearest dealer
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
12/28
10
Slightly pull the Germkill Life Indicator Coverupwards and remove it from the purifier.
Empty water from the Cleansing Collection
Chamber completely.
Remove the Top Cover with the Sediment Filter.
Remove Top Chamber and empty it completely.
Please empty the water from the Top Chamber, Cleansing Collection Chamberand the Transparent Chamber completely before replacing the Germkill Kit.
Always keep Microcharged Membrane on a clean surface.
1 2
3
Remove the Microcharged Membrane Assembly by twisting it in
the anti-clockwise direction and keep the Microcharged Membraneand the Cleansing Collection Chamber on a clean surface.
4
ORDERING AND CHANGING THE GERMKILL KIT
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
13/28
11
Remove it from the purifier.
Remove the Carbon Polisher by rotating it in the
anti-clockwise direction.
Rotate the Microfibre Mesh in the
anti-clockwise direction. The Carbon Polisherwill come out along with it.
ORDERING AND CHANGING THE GERMKILL KIT
Discard the old Carbon Polisher.
5 6
7 8
OLD
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
14/28
12
Wash the Microfiber Mesh
under a jet of clean water.
ORDERING AND CHANGING THE GERMKILL KIT
9
Insert the new Carbon Polisher.
Rotate clockwise to fit.
10
11
NEW
12
Replace the Microfiber Mesh and the Carbon PolisherAssembly in the purifier. Rotate clockwise to fit.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
15/28
13
Hold the base and rotate the Microcharged Membrane inclockwise direction to fit. Ensure tight fitment.
17
Hold the base and rotate the
Microcharged Membrane in theanti-clockwise direction.
Discard the old Microcharged Membraneand insert the new Microcharged Membrane.
Remove the Microcharged
Membrane along with its base,from the holder. Keep the holder
on a clean surface.
ORDERING AND CHANGING THE GERMKILL KIT
14 15
16
Wash hands thoroughly, take the
Microcharged Membrane (removed in
Step 4), rotate the base in anti-clockwise
direction.
13
Please empty the water from the Top Chamber, Cleansing Collection Chamber and the
Transparent Chamber completely before replacing the Germkill Kit.Always keep Microcharged Membrane on a clean surface.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
16/28
14
Replace the Microcharged Membrane along withthe base in the Microcharged Membrane holder
and rotate the base in clockwise direction to fit.
ORDERING AND CHANGING THE GERMKILL KIT
18 19
Insert the Microcharged MembraneAssembly at the base of the Cleansing
Collection Chamber. Rotate clockwise to fit.
21
Replace the Cleansing Collection Chamber on the
Transparent Chamber.
20
Turn the Germkill Processor in
anti-clockwise direction to remove anddiscard the old Germkill Processor.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
17/28
15
Place the Germkill Life Indicator Cover in thegrooves provided on the Cleansing Collection
Chamber and push it downwards to fit.
Fill the Top Chamber and drain out
all the water that collects in the Transparent Chamberfor first two cycles. Pureit is now ready to use
from third cycle onwards.
Insert the new Germkill Processor androtate in the clockwise direction to fit.
Ensure tight fitment.
ORDERING AND CHANGING THE GERMKILL KIT
22 23
25
Place the Top Chamber on the
Cleansing Collection Chamber.Place the Top Cover with the Sediment Filter.
24
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
18/28
16
Remove Top Lid and clean it with tap water. Leave it to
drip dry.
Remove the Sediment Filter from the Top Cover and
clean it by tapping it under a stream of clean water to
dislodge dirt and grime.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
1 2
3 4
Do not clean the hole in the Top Chamber with sharp objects.
Rinse the Top Chamber with clean water and leave it todrip dry in a clean place.
Remove Top Cover and clean it with tap water. Leave itto drip dry.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
19/28
17
Wash hands thoroughly. Rotate the Microcharged Mem-brane Assembly in anti-clockwise direction to remove.
Keep it aside in a clean place.
Rotate the Germkill Processor in the
anti-clockwise direction to remove and keep it in a safe
place.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
8
6
Do not remove the Microcharged Membrane Assembly without emptying water from the
Cleansing Collection Chamber.
Empty the water from theCleansing Collection Chamber.
7
Slightly pull the Germkill Life Indicator Cover upwards
and remove it from the purifier.
5
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
20/28
18
Wash the Microfiber Mesh under
a jet of water.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
12
Rotate the Carbon Polisher in the
anti-clockwise direction to remove.
10
Wash the Carbon Polisher in running water
by gently scrubbing it with hands. Do not use
detergent or scrubber.
11
9
Rotate the Microfiber Mesh in the anti-clockwise
direction to remove. The Carbon Polisher will come out
along with it.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
21/28
19
CLEANING & MAINTENANCE OF PUREIT EXCELLA
14
16
Clean the Cleansing Collection Chamber with clean
water and leave to drip dry.
You may observe some amount of water coming back through the below pump which
can be pushed into the Carbon Polisher again. Please clean the Carbon Polisher with thebellow pump multiple times for best results.
15
Close the mouth of the carbon block with one hand
and squeeze the bellow pump with the other hand
to force the water through the carbon block. You
can see dirt coming out of the carbon block.
Repeat procedure 5-6 times.
Fill Pureit water in the bellow pump.
13
Insert the bellow pump into the nozzle at the
bottom of the Carbon Polisher, the area opposite to side
with handles given.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
22/28
20
While cleaning the Microcharged Membrane, please ensure your hands are germ free.
CLEANING & MAINTENANCE OF PUREIT EXCELLA
18
20
In case your water quality is very bad and the flow rate does not improve on cleansing the Microfiber Mesh and the
Carbon Polisher you need to clean the Microcharged Membrane as shown in point 20 and 21.
Fill Pureit water in the bellow pump. Insert the bellow
pump into the nozzle provided at the bottom of theMicrocharged Membrane Assembly.
Wash the Transparent Chamber with clean Pureit water
and drip dry.
19
Replace the Microfiber Mesh assembly in the
Cleansing Collection Chamber by turning it clockwise.
Ensure tightness.
17
Replace the Carbon Polisher in the
Microfiber Mesh assembly by turning
it clockwise. Ensure tightness.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
23/28
21
CLEANING & MAINTENANCE OF PUREIT EXCELLA
23
Replace Cleansing Collection Chamberon the Transparent Chamber.
24
Insert the Germkill Processor and turn in clockwisedirection to fit. Ensure tightness.
Now hold the Microcharged Membrane base and
squeeze the bellow pump to force water out of theMicrocharged Membrane Assembly. You can see dirt
coming out of the membrane. Repeat procedure 5-6times.
21 22
Insert the Microcharged Membrane Assembly at the base
of the Cleansing Collection Chamber and turn clockwiseto fit. Ensure tightness.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
24/28
22
CLEANING & MAINTENANCE OF PUREIT EXCELLA
Clean the mouth of the tap with dilute disinfectant likebleach/hypochlorite (50 ppm available chlorine). Pour inwater till the top of the Top Chamber and drain out all
the water that collects in the Transparent Chamberfor first two cycles. Pureit is now ready to use
from third cycle onwards.
28
26
Replace the Top Chamber on the Cleansing CollectionChamber.
Replace the top cover with the Sediment Filterand the Top Lid on the Top Chamber
27
Place the Germkill Life Indicator Cover in the grooves
provided on the Cleansing Collection Chamber and pushit downwards to fit.
25
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
25/28
23
DOs DONTs
Clean the top lid, the Top Chamber, the Cleansing Collection Chamber
and the tap regularly Clean with water and then leave the components to drip dry
Clean the tap with a mild hypochlorite solution
If necessary, use a plastic brush to aid cleaning
Remove the Germkill Processor while cleaning and keep upright in adry place
Empty the water from the Cleansing Collection Chamber before removingthe Microcharged Membrane Assembly
Remove the Germkill Processor before emptying out the water from theCleansing Collection Chamber
The Pureit Excella guarantee of getting water that is completely protectedfrom harmful germs applies only if you ensure that the TransparentChamber of the purier and the tap are hygienically kept, and that germsare not introduced due to contact with hands, drying with a cloth orany other means
You should only store water in Pureit and not use other bottles andcontainers, to avoid re-contamination of the water
During the functioning of the device all the components of the Germkillkit need to be present in the device
You should ensure that the area around and beneath the purier is keptclean at all times
Keep all components of the Pureit Germkill Kit out of reach of childrenat all times
Ensure that the purier is placed on a at surface at all times, andnever tilt the Transparent Chamber to take out water
If you ever want to shift the purier, do so only after both theTop Chamber and Cleansing Collection Chamber are empty. Otherwise the
purier may leak, and the purication process may get affected Always rely only on the red Indicator to replace the Germkill Kit. TheAuto Shut-off is only an additional assurance of safety in some cases,the input water quality may prevent it from functioning
Output water may continue to have ora which are harmless and poseno health hazard to normal healthy adults and children
Always clean the Pureit system only as described in the section oncleaning
Over a period of time you may nd ne oating particles or scaling inTransparent Chamber because of natural minerals in the source water, insuch case just clean the Transparent Chamber with puried water
If you are planning not to use the purier for a period more than 2days, you need to empty out the entire purier including the Transparent
Chamber, the Cleansing Collection Chamber, the Batching Chamber, andthe Top Chamber.
Do not clean the Pureit system with soap or detergent of any abrasive
cleaners or tools like wire mesh Do not twist the Microber Mesh/Sediment Filter while cleaning.The Microber Mesh might change color over a period of time.This does not affect the performance of Microber Mesh
Ensure that you dont inadvertently introduce germs into the TransparentChamber or the tap e.g. through your hands or by using a drying cloth.Always use puried Pureit water for doing the last rinse of the TransparentChamber, and then let it drip-dry
Do not normally wash the Cleansing-Collection Chamber Do not pour boiling or hot water (more than 50C) or freezing cold water
(less than 10C) into, or on the Pureit system. Do not pour hot water directly from an overhead tank or any other source
in your Pureit as hot water uses up the Germkill Kit faster than normal. Ifrequired, allow the water to cool to room temperature before pouring it inthe Top Chamber. For the same reason do not keep your Pureit Excella in hot
surroundings like direct sunlight, near a stove or near a fridgeNever buy the Pureit Excella system, or a Pureit Excella Germkill Kit from anunauthorized source. You can visit a store near you to buy a Germkill Kit or callus at the Pureit helpline to locate our nearest dealer
Dont in any way try to open the Pureit Excella Germkill Kit components Do not use the Pureit system once the Germkill Life Indicator shows fully red Dont expose any of the components to re Dont drop any of the components, or the purier as a whole from a height.
This may cause the components to crack or break, and the guarantee ofgetting water that is completely protected from harmful germs will no longerbe valid
Dont put any chemical uids in the Pureit system. This is meant strictly fordrinking water only
If the Transparent Chamber is full, please do not ll water in the
Top Chamber, otherwise water will overow from the Transparent Chamber Do not try to open the Germkill Processor Do not pour water in the purier once the Germkill Life Indicator turns fully
red, thus preventing overow due to Auto Shut-off mechanism. This will ensurethat no one is hurt by slipping or damages to household items kept nearthe purier due to leaked water
Do not use the Germkill Kit after expiry which is post two years fromthe date of packing
Do not keep the Pureit purier in direct sunlight or near the window as itmay trigger growth of algae / appearance of green mass in puried waterDo not use water not intended for drinking in Pureit Excella system e.g., fromabandoned or abused water bodies or water sources in which human, animal orindustrial wastes are disposed, or water that is excessively acidic or alkaline
Water stored for more than two days may trigger growth of algae and
increase number of normal water ora causing turbidity / bad taste ofpuried water and hence should not be consumedDo not remove the Batching Chamber from the Cleansing Collection Chamber.If it gets removed accidentally, then replace the parts in proper location,as was assembled initially for consistent performance
Do not meddle with the Microcharged Membrane else it will get damagedand you might get unsafe water
Dont drink water from the purier if any one of the Germkill Kitcomponents is not tted
Pureit Excella has been specially designed to give you water that is completely protected from
harmful germs as long as the Pureit system is used in the way as prescribed in this manual.
Listed below are the things that you must take care of:
DOs & DONTs
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
26/28
24
FAQs
There is condensation in the Transparent Chamber.Is this a problem?
This normally happens because of temperature differences.
It does not affect the working of your Pureit and you willcontinue to receive water thatis completely protected from harmful germs..
What happens if some part of the Pureit Excellabreaks accidentally?
if some part of Pureit Excella breaks accidently, please visityour nearest Pureit dealer to purchase new one, or call us onour Pureit helpline to locate your nearest dealer.
What should I do if it takes a long time topurify water?
In case the water quality is bad the filtration units of Pureit
Excella may take a longer time to purify water. In such casesyou will need to clean the Carbon Polisher and the MicrofiberMesh. Please refer the Cleaning & Maintenance of PureitExcella section for this. If the flow rate still does not improvethen please clean the Microcharged Membrane as shown inthe Cleaning & Maintenance section.
How do I know that my Pureit Excellaneeds cleaning?
In case the input water quality is bad the filtration units ofPureit Excella may take a longer time to purify water. There willbe a time when the water stops coming into the TransparentChamber. This is an indication that you need to clean yourPureit Excella. Please refer the Cleaning & Maintenance ofPureit Excella sectionfor this.
Pureit Excella didnt fully remove the colour from theinput water. Is the water safe to drink?
Such a situation will normally not happen in Pureit Excella. Allthe colloidal clay, insoluble salts of calcium, magnesium, ironetc will be removed by the Microcharged Membrane. Such asituation if happens, suggests that Microcharged Membranehas been damaged. Please visit your nearest Pureit dealer topurchase new one or call us at the Pureit helpline to locateyour nearest dealer.
Can there be scaling in Pureit Excella?Dissolved chemicals in water can occasionally precipitate outof the water, and deposit inside Pureit Excella. This howeverdoes not in any way affect the Germkill capability of Pureit.To avoid scaling, rinse the Top Chamber & TransparentChamber once in a while. Do not use any abrasive cleaners ortools. Refer to Cleaning & Maintenance of Pureit Excella sectionfor details.
Will Pureit Excella remove salt and oil?
Input water may contain many materials which affect the tasteof water. Of these, Pureit Excella removes materials like oil,sand, soil, clay, dirt, decayed animal and plant waste, and harmful
impurities and is therefore likely to improve the taste of water.
However, Pureit Excella does not remove some dissolved saltsthat may contribute to taste like sodium chloride salt, calciumand magnesium. In fact, Pureit Excella retains some gooddissolved salts present in drinking water. This may affect the
taste of water.
Can one pour brackish water into Pureit Excella?
Yes, the water will be free of harmful germs, but there maynot always be an improvement in taste. However by pouringbrackish/sea water into the Pureit, there may be a risk ofchoking the system, and the Auto Shut-off mechanism maymalfunction.
Can there sometimes be particles in the water storedin the Transparent Chamber?
No. Particles will not escape into the Transparent Chamberthrough the filtering media. However you have to drain the firsttwo cycles that gets collected in the Transparent Chamber.
Sometimes there is a chlorine like smell near theGermkill Processor. Is this a problem?
No, this is not a problem. You will continue to get absolutelysafe, odour free, great tasting water from theTransparent Chamber.
Water is overflowing from the front of the purifier?
There might be two reasons for this. One, check yourGermkill Life Indicator. If it is red, then please order for a newGermkill Kit and replace it. Do not pour any more water in the
Top Chamber to avoid further spillage.Two, if the Germkill Life Indicator is not red, please clean theCarbon Polisher and the Microfiber Mesh and ensure properplacement of all parts in the Cleansing Collection Chamber. Ifthe problem persists, then please contact Pureit Helpline.
How long does it take for the water to get purified?
It depends on the quality of water that is put into PureitExcella. Typically 9 litres of water gets purified between 1.5-2hrs. Cleaning the Carbon Polisher and the Microfiber Meshregularly can also improve the flow rate.
Do I need to empty the water from Pureit Excellaif I am not using the purifier for a few days.
If there is stagnant water in Pureit Excella for more than 2 days,then discard one cycle of water and start consuming from thefresh cycle of water.
Will the purification capacity for GKK vary or remain1500 Ltrs. all the time?
While the GKK has been designed to purify 1500 Ltrs waterwhen the input water temperature is 25C under moderatehumidity conditions, the actual purification capacity willvary depending upon the input water quality, temperature& humidity conditions. Be assured that the quality of waterex-Pureit tap will always be same in terms of safety againstpathogenic microorganisms.
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
27/28
25
TECHNICAL SPECIFICATIONS FOR PUREIT EXCELLA
Pureit Excella
Height 61 cms
Width 33 cms
Depth 36 cmsWeight 3.7 kgs
Total purifier volume 23 litres
Water storage capacity 9 litres
Material of construction Food safe, non-toxic, engineering plastics
Warranty Details1 year warranty against manufacturing defects from the date of purchase(GKK not covered)
Germkill Kit
Material of construction Food safe, non-toxic, engineering plastics
Purification capacityThe Germkill Kit has been designed to typically give 1500 litres of waterat a temperature of 25C, in moderate humidity conditions
Expiry period Two years from the date of manufacturing
Germkill performance standard
Meets stringent international criteria of the Environmental ProtectionAgency (EPA), USA, for harmful viruses & bacteria removal
The best performance of Pureit will be achieved if the input water to Pureitis from a municipal source, else you may have to regularly clean various
filtering components (except GKP) Top Chamber, Batching Chamber &Transparent Chamber with purified water as per instructions givenu/s - Cleaning and Maintenance
-
7/23/2019 Pureit Excella U-Manual Philippines PhII-V04
28/28
Setting benchmarks in
water purification
MexicanInstituteof Water
Technology[IMTA]
(Mexico)
Scottish
ParasiteDiagnosticLaboratory
(UK)
BioAgriLaboratories
(Brazil)
PT TUV
NORDIndonesia
LaboratoryDivision
(Indonesia)
Nationalinstitute
of Cholera
and EntericDiseases(India)
Certifi
catio
ns
No. 1choice of
families worldwide
- India
- Mexico
- Indonesia
- Brazil
- Bangladesh
- Nigeria
- Srilanka
- Kenya- Ghana
- Philippines
Pureit is the
worlds largest
selling waterpurifier brand*